5.3.2 Dump and Communication

Dump : Allows to dump all the Camera info/settings in a text file. This command is available in the CommCam View
Menu :

BaudRate (ComBaudRate): Set the Camera BaudRate. This command is available in the CommCam “Com” section :
 Read function : “r baud”;
Returned by the camera : Value of the Baud Rate
 Write function : “w baud” <index> with the index as follows :
 1 : 9600 Bauds (default value at power up)
 2 : 19200Bds
 6 : 57600Bds
 12 : 115200Bds
After changing the communication rate, the communication with the Camera could be interrupted
with the application (CommCam or whatever) it has made this change. The application has to
reconnect.with the appropriate baudrate. The baudrate will automatically switch to 9600 bds at the next
power down/up.