Extension of the clamping system The AGIE Universal Clamping Frame allows the workpiece to be fastened directly to its clamping plates. The hole pattern is compatible for all current clamping devices from the following manufacturers: • Mecatool • EROWA • 3R • Hirschmann The clamping devices must be mounted in accordance with the manufacturer’s instructions. Caution: When using the clamping devices, great attention must be paid to the risk of collision (ö “Collision-free zones”). Also take the size of the moving parts (arms, heads, cables, ...) into consideration during positioning, this being particularly important when clamping several pieces in the working area. Collision-free zones The collision-free zones in the following drawings may be occupied by the workpiece, clamping devices or anything else without the risk of collision. This is the case as long as nothing is clamped on the guide heads or the arms. These collision-free zones can be enlarged if the distance between the flushing nozzles and the workpiece surface is increased. Agiecut Cla, Cha, Evo, Exc ©AGIE 06.2002 C2.1 34 Technical data, Place of installation, Connections, Transport