5. Commissioning 5.5.6 Description of the status bytes SCON, SPOS, SDIR (RSB) Status byte 1 (SCON) Bit EN Description B0 Drive Enabled ENABLED = 0: Drive blocked, controller not active = 1: Drive (controller) enabled B1 OPEN Operation Enabled = 0: STOP active = 1: Operation enabled, positioning possible B2 WARN Warning = 0: Warning not applied = 1: Warning applied Fault number in diagnostic memory B3 FAULT Fault = 0: No error = 1: An error exists or an error reaction is active Fault number in diagnostic memory B4 24VL Voltage Load = 0: No load voltage = 1: Load voltage applied B5 HMI Drive control = 0: Device control by PLC/field bus = 1: Device control by FCT/MMI B6 OPM1 Operating Mode = 00: = 01: = 10: 10 = 11: B7 OPM2 Festo GDCP−SFC−LACI−DN−EN en 0812NH Record select (standard) Direct mode reserved reserved 5−39