Download Question

Transcript
practices occurring in the region to use in my SWAT project. Is there a
specific website/online source to find information about these data?
Answer:
If you want to incorporate WWTP information within SWAT you will need
to obtain the monitoring data collected at the WWTP outfall. I am not sure
how it works in North Carolina, but in Wisconsin the Dept. of Natural
Resources has each permittee's monitoring data (average daily flow and
concentration data collected during a given interval). From the monitoring
data we can calculate a monthly or annual load and incorporate it as a point
source within SWAT. Obtaining monthly loads is best, but if the information
is course you can extrapolate monthly loads from the annual information.
Reference the SWAT user manual in regards to the specifics for setting up a
point source input file. In SWAT 2009 the type of input file you setup is
dependent on the time step of the point source (rechour, recday,recmon,
recyear). Basically the SWAT input file will include the station
coordinates and load information.
68-"Record is deleted"
Question : When entering precipitation and temperature files into SWAT,
I get the following error: "Error-2147217071-record is deleted
DAO. Table Defs." At this point, the only option was to hit "OK," which I
did. Now, it seems that the daily precipitation data dbf is properly created
from the original text file. Then, I got another error: "Error in precipitation
gage data. Monitoring point features for not coincide [sic] with precipitation
station table." I am doing this on a backup copy of my project; otherwise all
looks great. I'm pretty sure the formatting of the precipitation and
temperature .dbf files (attached) is correct based on my past-experience with
SWAT and my review of the documentation. The text files containing the
daily values are definitely formatted correctly. I have ensured that
the files are in the appropriate folders and that the names of the
station files are identical to those in the listed in the table. Yes,
there should only be one precipitation station, which is the same
location for the temperature station, for the exercise I'm conducting.
Answer:
59