Transcript
4.4 Replacing the colour filters and gobos DANGER! Install the colour filters or gobos with the device switched off only. Unplug from mains before! Colour filters 1. Disconnect the fixture from mains and allow it to cool. 2. Remove the top plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover. 3. Turn the colour wheel to the desired position.The dichroic filters are fixed on the colour wheel by the magnets. 4. Release the dichroic filter from the colour wheel by inclining it from its position to break the power of the magnet. Protect the glass filter with a piece of paper or clout. 5. Insert a new dichroic filter into the colour wheel. 6. Place the top cover back before applying power. Static gobos 1. Disconnect the fixture from mains and allow it to cool. 2. Remove the top plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover. 3. Gently skew the gobo module to release it from the hole in the static gobo wheel and pull it up. 4. Insert the new gobo module spring holder under the distance stop and push the gobo module into hole in the static gobo wheel. 5. Replace the top cover before applying power.