118 en | Security Escort pager setup 6.5 Security Escort Alarm area setup In the Transponder Database under the File menu, select the transponder where the alarm area is to be programmed in. Click the [Edit Data] button, followed by Show areas radio button and select the desired area. Figure 6.4: Transponder Area Edit Dialog Number Each transponder can have up to 80 areas defined in them (prior to version 2.04 of the software, only 40 areas could be defined). This area number range from 0 to 79. Use the [Locate] button to define the area graphically on the map. Video Switcher Selects a system serial port that is programmed in the Remote Setup dialog. The purpose is to display the area, where the alarm is most likely located, on the CCTV monitors near the Central Console. The string would activate a macro in the video switcher that selects the appropriate camera, and controls any required zoom and tilt actions. Up to 40 characters may be entered. Control characters may be entered as "^A" for control A. 2015.05 | V2.15.0 | DOC Technical Reference Manual Robert Bosch (SEA) Pte Ltd