Download Security Escort 2.15 Technical Reference Manual
Transcript
62 en | System menus and screens Security Escort Figure 4.33: Popup Trouble Filter Dialog Transponder troubles group Communications failure To continually assure that communications between the Central Console and each transponder are functioning properly, each transponder is required to send a message to the Central Console periodically. If there is no response from the transponder, the Central Console displays a communications failure warning and records the condition in the audit file. If a transponder determines it lost communications with the Central Console, it assumes control of the outputs of the devices connected to it and transmits “I’M OK” messages until it is acknowledged by the Central Console. Notice! If during this loss of communications, an alarm transmission is received by one or more of the receivers attached to the transponder, the transponder activates any alert units attached to it as well as the horns and red LED’s on any of its receivers which detected the alarm transmission. Since the transponder does not have access to the Subscriber Database, it must assume that all transmitters are valid, so even unauthorized (not in the Subscriber Database) transmitters produce audible alarm indications (if the system is set for audible alarms in the Set Security Preferences dialog). 2015.05 | V2.15.0 | DOC Technical Reference Manual Robert Bosch (SEA) Pte Ltd