Download TIMS Advanced Modules User Manual
Transcript
UWB MODULE (ULTRA WIDEBAND PULSE GENERATOR) Digital, TTL-level data presented at the two data inputs is output as distinct shaped pulses. Each channel can output one of eight switch selectable pulse shapes, including three Gaussian Pulses, four Modified Hermite Pulses and a predefined pulse (Sync Pulse). The two input channels share the same digital clock. Four switch selectable operating modes are available: PPM: Pulse Position Modulation, BPM: Bi-Phase Modulation, OOK: On-Off-Keying, and OPM: Orthogonal Pulse Modulation. A fixed half bit width delay is also available. User defined pulse shapes can also be implemented with data pre-programmed in EPROM. INPUT DIGITAL SIGNAL DELAY INPUT DIGITAL DELAY OUTPUT DELAY OUTPUT MODE SELECT DUAL OUTPUT PULSE GENERATOR DIGITAL DATA 2 INPUT PULSE OUTPUT 2 DIGITAL DATA 1 INPUT PULSE OUTPUT 1 PULSE OUTPUT 2 PULSE OUTPUT 1 BLOCK DIAGRAM CLOCK INPUT FRONT PANEL USE DATA INPUTS DATA 1 and DATA 2 accept digital, TTL-level digital data where transitions must occur at the positive edge of the CLK input. CLOCK INPUT The CLK input must be synchronised and in-phase with the data at DATA 1 and DATA 2 inputs. DELAY INPUT and OUTPUT The DELAY input accepts a digital, TTL-level data signal and outputs the digital, TTL-level signal delayed by half a bit. TIMS AMS1 User Manual 140