Download KOSTAC Safety AZ-C1

Transcript
Programmable Logic Controller
SENSOR
ENCODER
COUNTER
INFORMATION
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
Safety
■Need for Safety
What kinds of measures are effective towards eliminating workplace
accidents? Japanese corporations conventionally aim to achieve "zero
accidents" via "human education." They believe that accidents are caused by
human errors and insufficient experience, and have developed the concept
of preventing the occurrence of errors through strong management, manualbased education, and all kinds of regulations.
However, due to various reasons including a decrease in skilled workers
resulting from aging population and an increase in part-time workers and
foreign workers, ensuring safety dependent only on "humans" cannot be
achieved any more. In the first place, the responsibility for ensuring safety
lies not with employees but with corporations. Not only human errors and
mechanical failures but also risks themselves should be reduced. Such
concepts originating from Europe and the United States are also gradually
spreading among Japanese corporations.
In the world of today, the ISO and IEC are playing central roles in promoting
the international standardization of standards concerning mechanical
equipment. Of course, Japan is no exception. The WTO member countries,
including Japan, are required to make each country's own standards comply
with the international standards of ISO and IEC based on the Agreement on
Technical Barriers to Trade. Preventing risks by actively using safety devices
even if human errors and mechanical failures unfortunately occur, or "zero
risks" … this is the new common sense for ensuring safety.
■Change in the Concept of Safety in
Japan
Conventional concept in Japan → Zero accidents
[Observe correct operations in order not to cause accidents / disasters]
- Operators' responsibility
- Responsibility of education
- Thorough training
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
A
A
Standards
Standards
Basic Safety
Basic
Safety
Standards
Standards
B Standards
B Standards
Group Safety Standard
Group Safety Standard
[Perform risk assessments / take reduction measures and design machines
with safety control]
- Enterprise's responsibility
- Inherently safe design
- Introduction of safe machines
S
S
S
* Establ
* Establi
●Norma
●Norma
C Standards
C Standards
Individual Product Specifications
Individual Product Specifications
■Procedure of ISO14121 Risk
Assessment
IEC6
IEC6
When designing equipment or changing its configuration, it is necessary
to correctly assess the degree of hazard and reduce the estimated risks to
within the allowable range. The intended level of safety can be secured by
ISO14121
リスクアセスメ
トの手順
repeating the process
of identifying hazards,ン
assessing
risks, and taking risk
ISO14121
リ
スクアセスメン
トの手順
reducing measures.
ISO1
ISO1
Start
Start
What is a hazard?
- Mechanical hazard: Crushing, pinching, piercing, cutting, impact, etc.
- Electrical hazard: Contact with a live part, insulation failure, static
electricity, etc.
- Thermal hazard: Fire, explosion, radiation heat, burns, etc.
- Noise hazard: Hearing loss, ringing in the ears
- Vibration hazard: Leading to serious disorder of the hands, arms, waist
and whole body
- Radiation hazard: Low frequency, high frequency, ultraviolet rays, infrared
rays, X-rays, etc.
- Material and material quality hazard: Low toxicity, stimulus, dust,
explosion, etc.
- Hazard generated by ignoring human engineering: Unhealthy attitude,
human errors, etc.
EN9
EN9
Clarification of Use and
Clarification
of Misuse
Use and
Predictable
Predictable Misuse
Identifying Hazards
Identifying Hazards
Estimates of Risk
Estimates of Risk
Risk Evaluation
Risk Evaluation
Is it an Allowable Risk?
Is it an Allowable Risk?
YES
YES
S
S
Risk Reduction
Risk Reduction
(Protective
Measures)
(Protective Measures)
NO
NO
End
End
** Established
Established as
as JIS
JIS B
B 9702.
9702.
* Established as JIS B 9702.
■Specific Protection Policies for Risk
Reduction
Evaluation
Evaluation
Starting
Starting
Point
Point
Evaluation
Starting
Point
Features
The ISO/IEC have developed a hierarchical structure that consists of "A
standards" that determine basic concepts and design technologies with
safety at the top, "B standards" that summarize group safety standards in
the middle, and "C standards" that determine safety standards of individual
machines at the
bottom. Users can ensure the safety of machines by
ISO/IEC
規格の階層化構造とは
ISO/IEC
combining these規格の階層化構造とは
standards.
↓
Concept of Europe and the U.S. → Zero risks
Safety
■Hierarchized Structure of ISO/IEC
Standards
Evaluation
Evaluation
Starting
Starting
Point
Point
Evaluation
Starting
Point
Common
Subject Matter
KOSTAC Safety AZ-C1
Risk
Analysis
Risk
Risk
Analysis
Analysis
HMI
Risk
Assessment
Risk
Risk
Assessment
Assessment
PLC
S
Risks should be reduced through three specific protection policies – a
"review of intrinsic safety design" in order to reduce hazards caused by
the equipment itself as much as possible, "safety protection policy" by the
isolation of hazards and the stopping of machines, and "additional protection
リスク低減のための具体的な保護方策
policy" such as the installation of emergency stop devices.
リスク低減のための具体的な保護方策
Inherently Safe
Inherently
Safe
Design Measures
Design Measures
Protection
Protection
Policy
Policy
Protection
Policy
Safety Protection
Safety
Policy Protection
Policy
Additional Protection
Additional
Protection
Policy
Policy
Information on Use
Information
on Use
(Measures Against
(Measures
Against
Residual Risk)
Residual Risk)
Safety Protection
Safety
Protection
by Isolation
by Isolation
Safety Fences
Safety Fences
Safety Protection
Safety
Protection
by Stopping
by Stopping
Safeguards
Safeguards
Safeguards
-- Interlock
Interlock Device
Device
--Interlock
Device
- Light
Light Curtains
Curtains
--Light
Curtains
Detection
- Detection Protective
Protective
- Detection
Devices, Protective
etc.
Devices,
etc.
Devices, etc.
Ensuring Stops
Ensuring Stops
Emergency
Emergency
Stop Device
Stop Device
Emergency
Emergency Stop
Stop Unit
Unit
Emergency Stop Unit
Preparation of Text Accompanies with
Preparation
of Hazardous
Text Accompanies
with
Indications of
Situations
Indications of Hazardous Situations
PL
PL
a
a
b
b
c
c
d
d
e
e
Cate
Cate
DC
avg
Categ
DC avg
DC avg
34
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
Safety
Evaluation
Starting
Point
Evaluation
Evaluation
Starting
Starting
Point
Point
S
F
P
EN954-1
安全カテゴリ
とは
S
F
P
p Unit
h
Possibility
Possibility
○
○ ●
● ●
◎ ◎
◎ ◎
◎
○ ● ● ◎ ◎
Possibility
Difficulty
Difficulty
○ ○
● ●
● ●
◎ ◎
◎
○ ● ● ◎
Possibility
Difficulty
Possibility
○
○ ○
● ●
● ◎
◎
○ ○ ● ◎
P1
P1
S2
S2
Serious Injury
Serious Injury
S2
P1
P2
P2
P2
P1
P1
F2
Common
Subject Matter
KOSTAC Safety
AZ-C1
Serious Injury
SJ
DL05/06
DL205
Among "functional safety" to be secured using computers and software,
regulations that define the requirements of functional safety such as reliability
IEC61508
安全インテグリテ
ィレベルとは
レベルとは
against deterioration安全インテグリテ
and life of component
parts, and self-diagnosis
IEC61508
ィ
functions for failures are of "safety integrity level (SIL)." The necessary
IEC61508 安全インテグリティレベルとは
level (SIL1 to 4) is decided according to the frequency of functional safety
requirements (low demand / high demand or continuous).
D4
D3
Programmer
DirectSOFT
■ISO13849-1 Performance Levels
Terminator I/O
Standards that are higher than the safety category are called "performance
levels." Since they incorporate stochastic elements such as the aged
deterioration of parts and further equalize the assessment procedures of the
ISO13849-1
パフォーマンスレベルとは
required level (PLr), the five
levels of assessment are easily understood and
ISO13849-1
パフォーマンスレベルとは
reliable.
Process Control
ZIP LINK
S
F
P
ISO13849-1
パフォーマンスレベルとは
S
F
P
Exposure
Seriousness of
Seriousness of
Damage
S
Damage
Seriousness of
Damage
Evaluation
Starting
Evaluation
Starting
PointPoint
Evaluation
Starting
Point
ective
Unit
Unit
F1
F1
■IEC61508 Safety Integrity Levels
es)
ctive
ce
ctive
Possibility of
Possibility of
Prevention
P
Prevention
Possibility of
Prevention
Rare and
Rare and
ShortF1Time
Short Time
Rare and
Short
F2Time
INFORMATION
Selection of
Selection
of
Safety
Category
Safety Category
B Selection
1 2 3of 4
B 1 2 3 4
Safety Category
○
B ●
1 ◎
2 ◎
3 ◎
4
○
●
◎
◎
◎
Exposure
Exposure
Frequency
F
Frequency
Exposure
Frequency
S1
COUNTER
Frequent and
P1
P2
Frequent and
P2
LongF2Time
○
○ ○
○ ○
● ●
◎
Possibility
Long Time
Difficulty
○ ○ ○ ●
Difficulty
* Established as JIS B9705-1.
Frequent and
P2
* Established as JIS B9705-1.
Long
Time ○Selectable If Additional Measures are Used.
●Normal Selection ◎Reasonable
Selection
○ ○are○
●
●Normal Selection ◎Reasonable Selection ○Selectable
If Additional Measures
Used.
Difficulty
* Established as JIS B9705-1.
●Normal Selection ◎Reasonable Selection ○Selectable If Additional Measures are Used.
es)
es)
e
e
ENCODER
In a machine control system, the safety maintenance capability of safetyrelated parts is classified into five "safety categories." It is required to
consider the seriousness of failures, frequency of exposure, time to be
exposed to risk, possibility of preventing risk, etc. and take measures to
EN954-1
とは
EN954-1
安全カテゴリ
とは
place machines in an安全カテゴリ
appropriate safety category.
Minor Injury
S1
S1
Minor Injury
Minor Injury
S1
Minor Injury
S2
S2
Serious Injury
Serious Injury
S2
Serious Injury
Exposure
Frequency
F
Frequency
Exposure
F1
F1
Frequency
Rare and
Rare and
ShortF1Time
Short Time
Rare and
F2 Time
Short
F2
Frequent and
Frequent and
LongF2
Time
Long Time
Frequent and
F1
F1Time
Long
Rare and
Rare and
ShortF1Time
Short Time
Rare and
F2
Short
F2 Time
Frequent and
Frequent and
LongF2
Time
Long Time
Frequent and
Long Time
Possibility of
Possibility of
Prevention
P
Prevention
Possibility
of
P1
P1
Prevention
Possibility
Low Risk
Low Risk
Possibility
Low Risk
P2
P1
P2
P1
P2
P1
P2
P1
P2
Difficulty
Possibility
Difficulty
P1
P2
P1
Possibility
Difficulty
Possibility
P1
P2
P1
Possibility
Difficulty
Possibility
P2
P1
P2
Difficulty
a
PLr
a
Safety
Features
c
d
d
P2
P1
P2
Difficulty
Possibility
Difficulty
P2
PLr
PLr
a
b
b
b
c
c
Difficulty
Possibility
Difficulty
Possibility
Difficulty
Possibility
Difficulty
Possibility
Difficulty
HMI
SENSOR
■EN954-1 Safety Category
Seriousness of
Seriousness of
Damage
S
Damage
Seriousness
of
S1
S1
Damage
Minor Injury
Minor Injury
PLC
High Risk
High Risk
Dedicated
Programming Tool
d
e
e
e
Specifications
Dimensions
Risk
required
to assess
In contrast to those mentioned above, four parameters are High
the performance level (PL) of a safety system.
- Category: Category (B,1,2,3,4)
- MTTFd: Mean Time To Dangerous Failur (High, Medium, Low)
- DCavg: Average Diagnostic Coverage (High, Medium, Low, None)
- CCF: Common Cause Failure (Not lower than 65 points, below 65 points)
When these complex elements are determined, the performance level (PL) of
aPL
safety system can be judged using the graph below.
PL
Precautions
MTTFd=Low
MTTFd=Low
MTTFd=Medium
MTTFd=Medium
MTTFd=Low
MTTFd=High
MTTFd=High
MTTFd=Medium
a
PL
a
ba
b
MTTFd=High
cb
c
dc
d
ed
e
Category B Category 1 Category 2 Category 2 Category 3 Category 3 Category 4
e DC
Category
B Category 1 Category
DC avg low 2 Category
DC avg med2 Category
DC avg low 3 Category
DC avg med3 Category
DC avg high4
avg none DC avg none
DC avg none DC avg none
DC avg low
DC avg med
DC avg low
DC avg med DC avg high
Category B Category 1 Category 2 Category 2 Category 3 Category 3 Category 4
DC avg none DC avg none
DC avg low
DC avg med
DC avg low
DC avg med DC avg high
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
35
Programmable Logic Controller
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
KOSTAC Safety AZ-C1
Features
Safety PLCs
- The KOSTAC Safety AZ-C1 is a safe PLC that meets
international safety standards aimed at achieving "zero
hazard" via risk assessment.
- The AZ-C1 contains safety relays and safety controllers,
and accurately performs supervisory control and
monitoring of several devices, while contributing to the
simplification of systems.
- As the flexible, low-cost and easy-to-understand
"standard of the new age," the AZ-C1 extensively covers
from single devices to miniature complex equipment.
■Features
Acquired advanced safety certification
Compact design, most suitable for small systems
The AZ-C1 can be used for applications that meet EN954-1 (category 4),
IEC61508 (SIL 3), and ISO13849-1: 2006 (Performance Level e). Users can
easily and surely create a safe environment that conforms to international
standards.
The compact design of each module allows it to be placed even in the palm
of your hand. Even if many modules are connected, the control panel only
requires minimal space. Maintenance is easy as any module can be attached
and removed without moving other modules in the case of replacement
following the occurrence of failure.
Highly reliable operation based on good selfdiagnosis functions
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
One-touch installation, one-push wiring
Each module can be attached to the DIN rail, which is widely used as a
control panel, with one touch. The use of removable terminal blocks makes
wiring operations when replacing devices greatly efficient and reduces the
risk of malfunctions by wiring errors. You will not need to be troubled with a
flood of wiring anymore.
The CPU module and input/output module are equipped with self-monitoring
functions. These functions constantly monitor for undervoltage and
overvoltage, grasp connection and operation status using test pulses, and
run crosschecks of switching using channel monitors.
Unrestricted system expansion via an abundant
array of expansion modules
Many extension modules such as safety control modules and general control
modules are available. Their unrestricted mixing and matching makes various
system architectures possible, thus meeting a wide range of requirements
from easy program-less control to complicated program control.
Displaying status and errors on the CPU
The surface of the CPU module is equipped with LEDs for status monitoring,
4-digit 7-segment LEDs, 4 series of push-button switches, etc. With support
that guarantees quick response, you can grasp important statuses and error
messages without connecting to external monitors and computers.
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
■ Model Number List
Name
Precautions
CPU Module
Model Number
AZ-C1-CPU (MON)
AZ-C1-CPUOP (MON)
SUB MON Module
AZ-C1-SUBMON
AZ-C1-S-STP (E)
Safety Input/Output Module AZ-C1-S-STP (LC)
AZ-C1-S-STP (E/LC)
AZ-C1-S-IN (E)
Safety Input module
AZ-C1-S-IN (LC)
AZ-C1-S-OUT
Safety Output Module
AZ-C1-RELAY
General Input Module
AZ-C1-NS-IN
General Output Module
AZ-C1-NS-OUT (COM+)
AZ-C1-POWER
Power Supply Module
AZ-C1-BOOSTER
Between Modules Based
AZ-C1-BASE
Programming Tool
AZC-Director
User's Manual
AZ-C1-USER-J-M
36
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Input (Points)
Remarks
Can be extended only for safety
input/output.
Loaded with battery
For partial stop (Program-less time)
Safety Control
Output (Points)
General
Control
Safety Control
General
Control
Floating
Non-floating
DC
Transistor
Relay
Transistor
4
4
ー
6
ー
ー
4
4
ー
2
16
ー
ー
ー
ー
ー
4
2
6
4
ー
16
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
16
ー
6
4
4
4
ー
ー
16
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
2×2
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
ー
16
Required for 10 modules (CPU included).
For maintenance
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
Features
PLC
HMI
SENSOR
■Program-less Mode
The use of a built-in authorization circuit in the CPU supports functional
performance required by the system. Just by appropriately combining the
modules, safety systems that conform to international standards can be
created easily, simply, and compactly.
Ensures security without individual authorization in
the system
The built-in circuit of the AZ-C1 is certified for safety. With the addition of
various safe modules, a safety system can be created and the trouble of
independently verifying the safety of the entire system and acquisition costs
can be largely reduced.
ENCODER
COUNTER
INFORMATION
■Programming Mode
No need for programming operations from a
computer
Ladders and function blocks can be programmed with the use of dedicated
programming software. The best safety system can be created with the
smallest module configuration, contributing to compactification and cost
reduction of the control panel. The AZ-C1 can quickly and flexibly respond to
system changes.
S1 installed, and one unit can perform the same
Several relay units are
operations as a system
with complicatedly
wired connection cables, thus
Status Display
LM
reducing the burden of maintenance checks.
E-STOP Input 1
S2
E-STOP Input 2
S1
E-STOP Input 1
S/R
Start
Reset
LM
Status Display
RB
Readback Input
S2
E-STOP Input 2
M1
Semiconductor
Output
S/R
M2
Reset
Semiconductor
Output
RB
Readback Input
O-P
Power
Source
M1
Semiconductor
Output
M2
Semiconductor
Output
O-P
Power
Source
Start
1
Input
Output
2
D4
Software "AZC-director" allows free design
A combination of modules lets users freely run control programs and realize
the system architecture that is most suitable for the scale of devices and
work content. It is the best way to ensure safety while remarkably enhancing
productivity by thoroughly eliminating wasted motions.
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
One CPU unit makes the coexistence of safety
control and general control possible.
If the AZ-C1 is connected to an "AZ-C1 SUBMON," a partial shut-down
circuit can be installed in the system. It ensures safety without reducing the
operation efficiency of the system more than required.
《Example of the installation of two AZ-C1 SUBMON units that control only
specific slots, under the CPU that controls all slots》
0
DL205
The security functions that ensure safety realize reliable operation. If an
abnormality or failure occurs, individual modules can be easily replaced,
and programs can be safely and quickly corrected, which makes for flexible
maintenance and less risk.
A combination of modules for creating a partial shutdown circuit
Slot
DL05/06
Making maintenance easy and quick if abnormalities
or failures occur
Input
Output
KOSTAC Safety
AZ-C1
SJ
The CPU of the AZ-C1 is equipped with a stationary circuit suitable for
creating a safety system. It needs no operation programming design
by computer. It is not necessary to newly acquire safety certification of
applications. Safety systems can be easily created simply by selecting
modules in accordance with the required system configuration.
Relay units for eliminating wiring troubles
Common
Subject Matter
3
4
5
6
A system that performs both safety control and general control can be
controlled by one CPU unit. Because each control can be edited as a separate
ladder program, both gang control and independent control are smooth. The
data of both programs can be also shared.
Safety
Flexibly dealing with changes in work content and
scale expansion
Dedicated
Programming Tool
The AZ-C1 can flexibly deal with the environment where work content
changes every day as seen with production floors doing limited production
of diversified products. Operations are easily changed over by simply
transferring a program created in advance via USB. The A Z-C1 can
accurately meet the requirements for complicated programs caused by an
increased number of devices.
Specifications
Features
Dimensions
Precautions
Module
Slot
Module
0
1
2
3
4
CPU
5
6
SUBMON#1
SUBMON#2
[Entire shutdown]
Group controlled by the CPU (Slot 0 to slot 6)
[Partial shutdown]
Group controlled by SUBMON#1 (Slot 3 to slot 4)
SUBMON#1
SUBMON#2
GroupCPU
controlled
by SUBMON#2
(Slot 5 to slot 6)
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
37
Programmable Logic Controller
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
KOSTAC Safety AZ-C1
Dedicated Programming Tool
■Dedicated Programming Tool "AZCDirector"
Koyo Electronics' software has the advantage of good performance and a
high degree of completion. The dedicated programming software "AZCDirector" is a sophisticated tool that can be used in Windows computers. It
allows free design of ladders and function blocks, whereby helping users to
deploy ideal safety systems.
Safety considerations for system designers
AZC-Director allows you to set various parameters concerning individual
input/output status and safety functions on an easy-to-see visual screen. You
can set passwords and PIN codes for project editing operations and transfers
to the main body to prevent persons except the system designer from making
changes.
Easy-to-see, easy-to-understand ladder
programming
AZC-Director enables you to select intended operations from iconized
instructions and design ladder programs with just a mouse. The contents of
the ladder are displayed on the screen in an easy-to-see manner, and you
can surely build and debug complex programs.
SJ
DL05/06
DL205
D4
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
Creating safety function blocks
AZC-Director allows you to create safety function blocks on you own. You
can easily design lean programs that are the most suitable for work content
and flexibly adapt to complicated changes in specifications. Moreover,
created function blocks can be classified and stored in folders. It is also easy
to convert to other safety systems and optimize existing system by partially
editing programs.
ZIP LINK
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
38
Confirming if a program is a safety circuit or general
circuit at a glance
The display can be switched between a safety circuit and a general circuit
(non-safety circuit) on the programming screen. You can check the operating
state of each circuit from the marks on the screen, and flexibly edit programs
and easily find careless mistakes.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
Specifications
ESD
RFI
Specifications
24 V DC±10%
21.6 to 26.4 V DC
Up to 48 W
0 to 55˚C
30 to 85% RH (No condensation)
No corrosive gases
Metal control box Protection class: IP54
2 or less DIN EN 50178 (VDE 0160)
20 years
Frequency
Acceleration
Amplitude
IEC 60068-2-6
10 to 57 Hz
̶
0.35 mm
57 to 150 Hz
49 m/s2
̶
IEC 60068-2-27
147 m/s2 ±X,Y,Z 3 times in each direction
IEC 61000-4-2
Aerial discharge: ±8 kV Contact discharge: ±6 kV
IEC 61000-4-3
Indoor: 80 to 2,000 MHz (10 V/m 80%)
FTB
IEC 61000-4-4
Signal line : ±1 kV
DC power source line: ±1 kV Functional ground line: ±1 kV
IEC 61000-4-5
To ground: ±1 kV
Vibration Resistance
Impact Resistance
Noise Resistance
Surge
Instantaneous Power Failure
Maximum System Reaction Rate
Program Memory
Memory Type
Backup Battery
Display
Basic Command
Timer Command
Function Command
External I/O Points
Internal I/O Points
Hold Flag
Link Flag
Edge Detection Flag
Data Register
Current Value Register
Special Register
Comment Memory
ENCODER
COUNTER
INFORMATION
Number of Sweeps
20
(1 octave per minute)
The instantaneous power failure allowed time is not longer than 10 ms and the instantaneous power failure interval is not
shorter than 1 s.
■ CPU Specifications
Items
Program System
Program Control System
Input-Output Control System
Execution Tme
HMI
SENSOR
■ General Specifications
Items
Supply Voltage
Allowable Supply Voltage
Power Consumption
Use Ambient Temperature
Use Ambient Humidity
Surrounding Atmosphere in Place of Use
Installation Site
Pollution Degree
Proof Test Interval
PLC
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
D3
Specifications
Programmer
Stored program system
Cyclic computing system
Image register system
15 ms / Scan
Only DC output is used.
Program-less mode
Relay output is used.
Only DC output is used.
Programming mode
Relay output is used.
12 K WORD (Internal memory: 64 KB)
CMOS-RAM, FLASH-ROM
Charge type (Lithium battery: Life is up to 5 years )
7 segments LED×4
Safety Control Program
16
4
7
256
1,024
768
2,048
512
512 bytes
512 bytes
2,048 bytes
64 K bytes
DirectSOFT
Terminator I/O
52.6 ms
67.6 ms
22.6 ms
37.9 ms
Process Control
ZIP LINK
General Control Program
16
4
54
256
1,024
768
2,048
512
1,024 bytes
2,048 bytes
2,048 bytes
64 K bytes
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
39
Programmable Logic Controller
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
KOSTAC Safety AZ-C1
Specifications
■ Power Source / Booster module
Items
Model Number
Supply Voltage
Output Current
Power Consumption
Backplane Bus
Fuse
Weight
Accessories
AZ-C1-POWER
24 V DC±10%
1.0 A: When the maximum module is mounted
Up to 24 W
3.3 V DC±10%, up to 15 W
External fuse 1.0 A
160 g
̶
Items
Model Number
Operation Voltage/Current
Fuse
Safety Input Number
Input Resistance
Input Voltage/Current
ON/OFF Level
Detectable Minimum Pulse Duration
Safely-detectable Minimum Pulse Duration
Safety Output Number
Output Voltage/Current
Input
Program-less Mode
Output
Weight
Terminal Type
Accessories
Specifications
Items
Model Number
Operation Voltage/Current
Fuse
Input Resistance
Input Voltage/Current
ON/OFF Level
Detectable Minimum Pulse Duration
Safely-detectable Minimum Pulse Duration
Safety Output Number
Output Voltage/Current
Program-less Mode
Input
Output
Weight
Terminal Type
Accessories
40
Specifications
AZ-C1-S-STP (LC)
AZ-C1-S-STP (E)
24 V DC ±10% /68 mA
Internal fuse 3.2 A, 4.0 A
DC 6 points
Dimensions
Precautions
Specifications
AZ-C1-CPU (MON)
AZ-C1-CPUOP (MON)
AZ-C1-SUBMON
24 V DC ±10% / 70 mA
Internal fuse 3.2 A
Internal fuse 3.2 A, 4.0 A
DC 8 points Floating (4) Non-floating (4)/2 points (+common) 6 points (-common)
Approx. 4.7 kΩ
24 V DC, 5 mA/point
ON: Minimum 18 V DC /3.5 mA OFF: Up to 4.7 V DC /0.5 mA
1.4 ms (Input filter 0.7 ms)
15 ms
DC 6 points (Source)
24 V DC, 0.5 A/point
Safety signal 2 systems (Contact point x 2), readback x 2, Start x 1, Reset x 1
Safety output 2 systems, action indication use x 2
230 g
200 g
Removable 36P terminal block
Between modules based (AZ-C1-BASE)
■ Safety Control Module for Input/Output Specifications
Safety
Dedicated
Programming Tool
155 g
Between modules based (AZ-C1-BASE)
■ CPU Module / SUBMON Module Input/Output Specification
Safety Input Number
Features
Specifications
AZ-C1-BOOSTER
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
AZ-C1-S-STP (E/LC)
Internal fuse 3.2 A
Floating (4)
Non-floating (2)
Non-floating (6)
Floating (2)
Non-floating (4)
2 points (+common),
4 points (-common)
6 points (-common)
1 point (+common),
5 points (-common)
Approx. 4.7 kΩ
24 V DC, 0.5 A/point
ON: Minimum 18 V DC /3.5 mA OFF: Up to 4.7 V DC /0.5 mA
1.4 ms (Input filter 0.7 ms)
15 ms
DC 4 points (Source)
24 V DC, 5 mA/point
Safety signal 2 systems
(Contact point x 2)
Safety signal 2 systems
(Light curtain x 2)
Safety signal 2 systems
(Contact point x 1, light curtain x 1)
Readback x 2
Safety output 2 systems
185 g
Removable 28P terminal block
Between modules based (AZ-C1-BASE)
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
Specifications
Safety Input Number
Input Resistance
Input Voltage/Current
ON/OFF Level
Detectable Minimum Pulse Duration
Safely-detectable Minimum Pulse Duration
Input
Program-less Mode
Output
Weight
Terminal Type
Accessories
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
Readback x 2
190 g
Removable 36P terminal block
Between modules based (AZ-C1-BASE)
Items
Model Number
Operation Voltage/Current
Safety Output Number
AZ-C1-S-OUT
24 V DC ±10%/74 mA
DC 16 points (Source)
Output Voltage/Current
24 V DC, 0.3 A/point
Output
COUNTER
Safety signal 2 systems
(Light curtain x 8)
■ Safety Output Module Specifications
Program-less Mode
Weight
Terminal Type
Accessories
ENCODER
Specifications
AZ-C1-S-IN (E)
AZ-C1-S-IN (LC)
24 V DC ±10%/62 mA
Internal fuse 3.2 A
DC 16 points
Floating (16)
Non-floating (16)
8 points (+common), 8 points (-common)
16 points (-common)
Approx. 4.7 kΩ
24 V DC, 5 mA/point
ON: Minimum 18 V DC/3.5 mA OFF: Up to 4.7 V DC/0.5 mA
1.4 ms (Input filter 0.7 ms)
15 ms
Safety signal 2 systems
(Contact point x 8)
SJ
DL05/06
DL205
D4
Specifications
AZ-C1-RELAY
24 V DC ±10%/107 mA
2 x 2 Relay output
D3
Up to 4 A resistance load / point
External fuse : Up to 4A
Safety output 8 systems
250 g
Removable 36P terminal block
Between modules based (AZ-C1-BASE)
Safety output 2 systems
265 g
Removable 8P terminal block
ON/OFF level
Detectable Minimum Pulse Duration
Number of Outputs Points
Output Voltage/Current
Weight
Terminal Type
Accessories
Programmer
DirectSOFT
Terminator I/O
Process Control
■ General Control Module Input/Output Specification
Items
Model Number
Operation Voltage/Current
Fuse
Number of Input Points
Input Resistance
Input Voltage/Current
HMI
SENSOR
■ Safety Input/Output Module Specifications
Items
Model Number
Operation Voltage/Current
Fuse
PLC
ZIP LINK
Specifications
AZ-C1-NS-OUT (COM+)
24 V DC ±10%/48 mA
Internal fuse 3.2 A
AZ-C1-NS-IN
24 V DC ±10%/25 mA
̶
DC16 points (-common)
Approx. 4.7 kΩ
24 V DC, 5 mA/point
̶
̶
̶
ON: Minimum 18 V DC/3.5 mA
OFF: Up to 4.7 V DC/0.5 mA
̶
1.4 ms (Input filter 0.7 ms)
̶
̶
̶
170 g
Removable 24P terminal block
Between modules based (AZ-C1-BASE)
DC 16 points (Source)
24 V DC, 0.3 A/point
175 g
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
41
Programmable Logic Controller
KOSTAC Safety AZ-C1
PLC
HMI
Dimensions
SENSOR
■Dimensions (Unit: mm)
ENCODER
COUNTER
10
INFORMATION
Common
Subject Matter
100
KOSTAC Safety
AZ-C1
CPU module: AZ-C1-CPU (MON), AZ-C1-CPUOP (MON)
Safety output module: AZ-C1-S-OUT, AZ-C1-RELAY
10
10
10
9
9
100
100
100
100
100
10
10
10
9
9
SJ
DL05/06
DL205
10
D4
45
45
30
Up to 2830
Up
80 to 28
8
80
8
D3
Power supply module: AZ-C1-POWER, AZ-C1-BOOSTER
Safety input module: AZ-C1-S-IN (E), AZ-C1-S-IN (LC)
Safety input/output module: AZ-C1-SUBMON, AZ-C1-S-STP (E), AZ-C1-S-STP (LC), AZ-C1-S-STP (E/LC)
General control module: AZ-C1-NS-IN, AZ-C1-NS-OUT (COM+)
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
10
10
10
9
9
100Safety
100
100
100
100
10
10
9
9
Features
Dedicated
Programming Tool
Specifications
10Dimensions
45
Precautions
42
45
30
30
Up to 28
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Up to 28
80
80
8
8
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
43
Programmable Logic Controller
PLC
HMI
SENSOR
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
KOSTAC Safety AZ-C1
Precautions
■Precautions in Use
■Safety Precautions
Installation site
When installing the KOSTAC Safety AZ-C1, avoid the environments shown
below to prevent failure and malfunction.
(1) Places where the ambient temperature is outside the range from 0 to
55˚C
(2) Places where the ambient humidity is outside the range from 30 to 85%
RH
(3) Places where condensation occurs due to rapid temperature changes
(4) Places that are exposed to corrosive gas and combustible gas
(5) Places where there are large quantities of conductive powder like iron
powder, oil mist, salt, and organic solvents
(6) Places that are exposed to direct sunlight
(7) Places where intense electric fields and ferromagnetic fields are
generated
(8) Places where vibrations and impacts are directly applied to the main
body
Installation
When installing the KOSTAC Safety AZ-C1, secure enough space around it
for ventilation and maintenance checks.
Space of at least 50 mm from both sides, top and bottom of the main body
D3
50 mm
Terminator I/O
50 mm
- Do not disassemble, repair, and remodel this product. Doing so may
damage the intrinsic safety functions and is dangerous.
- A "safety manager" must confirm that software design, installation,
and maintenance of this product are correctly performed. The "safety
manager" refers to a person who has the authority and responsibility
to ensure the safety at each stage of design, installation, operation,
maintenance, and disposal of mechanical equipment. Protective measures
are required so that persons other than the "safety manager" do not
change the programs, wiring or settings.
50 mm
- Do not use modules for general control for safety input or safety output.
Doing so may damage the safety of the system if a failure occurs in this
product or associated equipment, and is dangerous.
Process Control
ZIP LINK
- The power supply must meet at least one of the following requirements.
Safety main transformer:
EN 61588/VDE 0570 Part 2 to 6 "Special requirements of safety
transformers for general application (IEC 61588-2-6: 1997)"
Switch mode power supply:
EN 60950-1 "Information equipment - Safety - Part 1" and EN 50178
"Electronic equipment for power source". Moreover, the power supply
must be applicable to SELV circuits defined by EN 60950-1.
- Regarding devices concerning safety functions to be connected to this
product, use those that meet safety standards according to the safety level
and category determined in risk assessments. Moreover, the conformance
of safety level and category of the entire system needs to be assessed by
an authorized third party accreditation organization.
50 mm
Programmer
DirectSOFT
- This product cannot be installed outside the control panel. Use this
product by installing it in an enclosure of IP54 or higher standard.
mm
Installation on DIN50 rails
This product can be installed using commercial DIN rails of 35 mm in width
50 mm to JIS C 21812). Anchor the50product
mm
(conforms
using commercial fasters
for DIN rails on both ends of the main body so that the main body does not
move.
50 mm
Module terminal block
Safety
Features
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
44
* When you use rod terminals except
The
terminal block of each module is a screwless
10 mm terminal.
those made by recommended
The
rod terminals
shownthe
below
conform to the terminal blocks.
manufacturers,
consider
following
dimensions.
Recommended
rod terminal models:
AI0.75 to 10 GY (Made by Phoenix Contact K.K.)
Applicable cable: AWG18
AI1
to 10 RD (Made by Phoenix Contact K.K.)
Cross-section of cable: 0.75 to 1 mm 2
When
making
rod terminals,
Length
of rod terminal:
10 mmensure the rod terminals conform
to cables and
crimp tools.
* When you use rod terminals except
those made by recommended
manufacturers, consider the following
dimensions.
10 mm
Applicable cable: AWG18
Cross-section of cable: 0.75 to 1 mm 2
Length of rod terminal: 10 mm
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
Latest catalog (free) is available online.
Visit our website ▼
http://www.koyoele.co.jp/english/
Programmable Logic Controller
KOSTAC Safety AZ-C1
Precautions
■Warranty Conditions:
Points to be Checked When
Ordering This Product
When estimating or ordering our control products, the warranty conditions
shall be as follows unless there are special instructions or considerations in
the estimate, contract document, catalog, or specifications.
〔Warranty period〕
The warranty period of the delivered product shall be one (1) year from the
date that it is delivered to the designated place.
〔Warranty scope〕
If a failure occurs due to our responsibility during the warranty period
mentioned above, we shall be responsible for replacing or repairing the failed
parts of the device.
However, in any of the following conditions, it shall be excluded from the
scope of warranty.
(1) If customers improperly handled or used the product
(2) If the failure was caused by reasons other than the delivered product
(3) If the product was remodeled or repaired by companies other than Koyo
Electronics Industries
(4) If the failure was caused by reasons not attributable to Koyo Electronics
Industries, such as natural disasters
(5) If the failure was caused by reasons that could not be scientifically or
technologically predicted at the time when the device of Koyo Electronics
Industries was designed
The warranty shall cover the delivered product itself. Koyo Electronics
Industries shall be exempted from compensation for damage caused by the
failure of the delivered product.
〔Scope of responsibility〕
Koyo Electronics Industries accepts no liability whatsoever for direct or
indirect damages or secondary damages resulting from the use of our
products.
Koyo Electronics Industries accepts no liability whatsoever for damages
resulting from programs created using our products or their results.
〔Conditions for applications〕
(1) When using our products, customers are requested to check their
conformance to per tinent standards, laws and regulations by
themselves.
Customers are also requested to check their conformance to their
machines, devices, and systems by themselves.
If customers use our products without checking conformance, Koyo
Electronics Industries accepts no liability for the conformance of
products.
(2) Our products have acquired certification under international standards
concerning the protection against mechanical hazards, but this does not
guarantee that the products will not incur failures or problems.
PLC
HMI
SENSOR
(3) It is prohibited to use our products for applications that pose grave
danger to human life or property including the applications mentioned
below.
Koyo Electronics Industries accepts no liability for damages resulting
from the use of our products in such applications.
◇ Thermal, hydraulic, and nuclear power plants
◇ Train and railway systems
◇ Aircrafts and air traffic control
◇ Other transportation systems
◇ Medical machines
◇ Entertainment machines
◇ Incineration and fuel systems
◇ Gas, water, and electricity supply systems
◇ Around-the-clock continuous operation systems
◇ Facilities that handle nuclear, hazardous, or chemical materials
◇ Mining and drilling
◇ Applications that pose high risks to human life, health or property
(4) If customers use our products for applications that pose a risk to
human life or property, they are requested to sufficiently consider
calling attention to dangers and redundant design across the entire
system, secure safety and reduce hazards at the source. In such case,
customers are requested to confirm that our products are appropriately
used and installed for intended applications in the design phase.
Moreover, customers are requested to clearly notify users of predictable
precautions and prohibited matter sin use so that our products do not
incur failures because of incorrect use or improper handling by third
parties
〔Change in specifications〕
The specifications of products described in this catalog are subject to change
due to improvement or other circumstances.
Regarding actual specifications when you purchase the product, consult with
our sales persons.
ENCODER
COUNTER
INFORMATION
Common
Subject Matter
KOSTAC Safety
AZ-C1
SJ
DL05/06
DL205
D4
D3
Programmer
DirectSOFT
Terminator I/O
Process Control
ZIP LINK
〔Scope of services〕
The prices of delivered products do not include service costs such as
dispatching engineers. Therefore, separate expenses will be charged in the
following cases.
(1) Guidance on installation and adjustment, and witnessing of test-runs
(2) Maintenance checks, adjustments, and repairs
(3) Technical guidance and technical education
Safety
Features
The product is packaged according to our packaging specifications.
The warranty provided with this product assumes that it is traded and used in
Japan.
Regarding trade and use of this product outside Japan, consult our sales
persons.
The specifications and prices described in this catalog were valid when the catalog was issued.
For the latest information, contact our sales persons or see our website.
Dedicated
Programming Tool
Specifications
Dimensions
Precautions
KOYO ELECTRONICS INDUSTRIES CO., LTD.
GENERAL CATALOG 2016
45