ATTACHMENT National Differences Page 62 of 67 Report No. 11019909 001 National Differences Clause Requirement − Test 6.4 Equipment intended for connection to telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC. Continuous ringing signals up to 16 mA only are permitted if the equipment is subjected to special installation and performance restrictions. Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. Document (paper) shredders likely to be used in a home or home office (Pluggable Equipment Type A plug configuration) are required to comply with additional requirements, including markings/instructions, protection against inadvertent reactivation of a safety interlock, disconnection from the mains supply (via provision of an isolating switch), and protection against operator access (accessibility determined via new accessibility probe & probe/wedge). M.2 Annex NAD Annex NAF IECEE CB Bulletin on 2008-07-31 Result – Remark Verdict N/A N/A N/A N/A Canadian National Differences