Download Manual - Fireplace Showcase
Transcript
Stardance® Direct Vent/Natural Vent Gas Heater Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge Maximum Run 18 20 feet 16 20 - 40 feet 14 up to 60 feet 1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors. 2. Connect the thermostat wires to the valve. (Fig. 51) Install the Front Plate Hold the front plate by the window bars and lift it into position, engaging the two steel tabs on the top corners behind the adjacent bosses in the side plates. (Fig. 53) Then seat the Front against the sides so the tabs at the bottom lip engage with the notches in the stove legs. When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it. Engage steel tabs gehind the cast iron bosses Receiver Installation - SDDVTCS Series Once the blower is installed to the back of the SDDVTCS Series stove, install the receiver. 1. Slide receiver into igniter bracket as shown in Figure 52. 2. Attach igniter bracket with receiver to valve with #1032 x 1/4 screws supplied. 3. Connect receiver wiring to valve as shown on Page 43, Figure 91. 4. Plug igniter wire from burner into the back of the igniter bracket. Receiver installation complete. Control Door Bottom tabs engage notch in the leg. ST474 Fig. 53 Install the front plate. ST474 stove. This completes assembly of the Stardance Stardance Front 10/3/00 Receiver Valve ST1121 Igniter Bracket Fig. 52 Install receiver. ST1121 receiver install 30004968 29