Z01E-EN-01+ZFX+SettingGuide.book Seite 61 Mittwoch, 13. Februar 2008 2:38 14
5-2 BANK and BANK-Group
Appendices
Which BANK/BANK-Group should be set, just after start-up?
They can be set in the following menu.
MENU mode - [System] - [Startup]
Setup Item
Startup Bank Group
Startup Bank
Description
Sets the bank group No. to be displayed when the Controller is
started up. (default value: 0)
When bank groups 1 to 31 are selected, start up the Controller
with the SD card containing the corresponding bank data
attached.
Sets the bank No. to be displayed when the Controller is
started up.
Range: 0 to 31 (default value: 0)
How to switch BANK/BANK-Group
1. Manu Operation
BANK
Menu-mode - [Bank] - [Bank] - [Switch]
BANK-Group Menu-mode - [Bank] - [Bank Group] - [Switch]
2. Serial Command via RS-232C/422, USB, Ethernet (*1)
3. Parallel Command
It’s needed to send the command from external device (e.g. PLC)
Please see the detail in “User’s manual”
How to upload BANK/BANK-Group
1. Upload BANK 0-31 (BANK-Group 0-31) to ZFX from SD card
a) Manu Operation
BANK
Menu-mode - [Tool] - [Backup] - [Bank data] - [Load]
BANK-Group Menu-mode - [Tool] - [Backup] - [Bank Group data] - [Load]
b) Serial Command via RS-232C/422, USB, Ethernet (*1)
2. Upload BANK 0-31 (BANK-Group 0-31) to ZFX from External device (e.g. PC, PLC)
a) Serial Command via RS-232C/422, USB, Ethernet (*1)
How to back up BANK/BANK-Group
1. Back up BANK 0-31 (BANK-Group 0-31) to SD card from ZFX
a) Manu Operation
BANK
Menu-mode - [Tool] - [Backup] - [Bank data] - [Save]
BANK-Group Menu-mode - [Tool] - [Backup] - [Bank Group data] - [Save]
b) Serial Command via RS-232C/422, USB, Ethernet (*1)
2. Back up BANK 0-31 (BANK-Group 0-31) to External device (e.g. PC, PLC) from ZFX
a) Serial Command via RS-232C/422, USB, Ethernet (*1)
Note (*1) It’s needed to send the command from external device (e.g. PC, PLC)
Please see the detail in “Serial Communication Command Reference”