Download ATTENTION:

Transcript
31
32
5) Legal warranty does not cover: expenses with installation
of product, installation of software, installation of microcomputer,
transport of product to the factory or sales point, labor cost, materials,
parts and adaptations necessary to the preparation of the premises
where the equipment will be used, such as: electric wiring, computer
technician expertise, masonry, hydraulic installations, grounding
system, as well as its adaptations. The warranty does not cover either
parts subjected to wear and tear such as: command switches, control
keys, handles and mobile parts, sucker applicators, application pens
for microderm abrasion, power cable, connection cables to the patient,
transducer cables, conductive silicon rubber applicators, diathermy
applicators, batteries, ultra-sonic transducer (when improper use or
its fall is proved), equipment cabinet.
6) No sales point of IBRAMED has authorization to alter the
conditions here mentioned, or to take any commitment in the name of
IBRAMED.
STRIAT – Accessories
02 80 x 100 mm aluminum-vegetable sponge electrodes
01 pen with needle electrode cable with connection to the patient
(for microgalvanic one)
01 cable with red and black clips for ionization of connection to the
patient (galvanic current)
01 elastic belt with velcro
01 detachable power cable
Packing with 10 sterilized needles
01 manual of instructions
The use of cables, electrodes and other accessories different from
those specified above, may result in the increase of emissions and in
the decrease of the equipment immunity.
STRIAT – Technical Characteristics
Aparelho :
Número de série :
Registro Anvisa (MS) :
Data de fabricação :
Prazo de validade : 5 anos
Engenheiro responsável : Maicon Stringhetta
CREA - 5062850975
Striat is a equipment designed for continuous operation mode. It uses
microcontrollers which guarantees the precision of the values
displayed. This exactitude of the operation data is in accordance with
what is prescribed by the particular standard for the safety of
neuromuscular stimulation equipment – NBR IEC 60601-2-10,
clause 50 / sub-clauses 50.1 and 50.2. The control of the output
amplitude continuously controls the intensity of the current from the
minimum to the maximum and its minimum value exceeds 2% of the
value at the maximum position. Parameters such as output wave
shapes, pulse duration, pulse repetition frequency, output current
amplitude range do not differ more than +− 30%, mentioned in the
following technical description.
The values of the Duration of the pulses and pulse
repetition Frequencies described here were measured at 50% of
the maximum output amplitude.
These parameters are valid for a charge impedance of 1000
ohms. The charge impedance effect in the described parameters is
very important. If the device is operated out of the band of the
specified charge impedance, it could be inexactness in the values