Download ATTENTION:
Transcript
31 32 5) Legal warranty does not cover: expenses with installation of product, installation of software, installation of microcomputer, transport of product to the factory or sales point, labor cost, materials, parts and adaptations necessary to the preparation of the premises where the equipment will be used, such as: electric wiring, computer technician expertise, masonry, hydraulic installations, grounding system, as well as its adaptations. The warranty does not cover either parts subjected to wear and tear such as: command switches, control keys, handles and mobile parts, sucker applicators, application pens for microderm abrasion, power cable, connection cables to the patient, transducer cables, conductive silicon rubber applicators, diathermy applicators, batteries, ultra-sonic transducer (when improper use or its fall is proved), equipment cabinet. 6) No sales point of IBRAMED has authorization to alter the conditions here mentioned, or to take any commitment in the name of IBRAMED. STRIAT – Accessories 02 80 x 100 mm aluminum-vegetable sponge electrodes 01 pen with needle electrode cable with connection to the patient (for microgalvanic one) 01 cable with red and black clips for ionization of connection to the patient (galvanic current) 01 elastic belt with velcro 01 detachable power cable Packing with 10 sterilized needles 01 manual of instructions The use of cables, electrodes and other accessories different from those specified above, may result in the increase of emissions and in the decrease of the equipment immunity. STRIAT – Technical Characteristics Aparelho : Número de série : Registro Anvisa (MS) : Data de fabricação : Prazo de validade : 5 anos Engenheiro responsável : Maicon Stringhetta CREA - 5062850975 Striat is a equipment designed for continuous operation mode. It uses microcontrollers which guarantees the precision of the values displayed. This exactitude of the operation data is in accordance with what is prescribed by the particular standard for the safety of neuromuscular stimulation equipment – NBR IEC 60601-2-10, clause 50 / sub-clauses 50.1 and 50.2. The control of the output amplitude continuously controls the intensity of the current from the minimum to the maximum and its minimum value exceeds 2% of the value at the maximum position. Parameters such as output wave shapes, pulse duration, pulse repetition frequency, output current amplitude range do not differ more than +− 30%, mentioned in the following technical description. The values of the Duration of the pulses and pulse repetition Frequencies described here were measured at 50% of the maximum output amplitude. These parameters are valid for a charge impedance of 1000 ohms. The charge impedance effect in the described parameters is very important. If the device is operated out of the band of the specified charge impedance, it could be inexactness in the values