Workbench www.snellgroup.com Controllers Reference Polltime=1000 The frequency (in milliseconds) SC12 polls the router for status. Default value is every 1000 milliseconds. Increasing this value reduces the load on SC12 and the router by polling it less frequently. However, it does in crease the time before an error is reported. It may be necessary to do this on a heavily loaded SC12 or router. Reducing this value reduces the time before an error is reported but increases the load on the SC12 and the router. The value should not be set lower than the TIMEOUT value. Timeout=50 This is the timeout in milliseconds for a response from the router. The default is 50 milliseconds. This should be sufficient for most routers when single commands are sent in a TCP/IP packet. If multiple connect messages are sent in a single TCP/IP packet the timeout should be increased to 200 milliseconds. Also if the router is heavily loaded this value may need to be increased. The number of TCP/IP connections to the SC12 should not effect the timeout, since this is the timeout on the serial port to the router. The clients connecting to the SC12 may need to adjust their timeout for the response on the network due to messages on multiple TCP/IP connections being serialized to the router. Return_Status_5=true This determines whether status request 1 messages return the status response 5 message, or whatever response is returned from the router. The default is YES. Setting this to NO means that status response 1 to 4 are returned depending on what router the SC12 is connected to (See SW-P-02 for which routers return which responses). This is intended for use with existing equipment that does not support the status response 5 message. TCP_Connecteds=true Used to switch on or off unsolicited connects on the TCP connection. When set to false a connected messages are only sent on a TCP port in response to a connect on that TCP port. When set to true it behaves more like the serial ports in that whenever a crosspoint is set a connected is sent on all open TCP connections, even if not set by a command on that port, for example, a panel. The default =true. Connect_MC_ENA=true Enables the multi-cast address used for connecteds. Default=true. Stat6_MC_ENA=true Enables the multi-cast address used for status 5 changes. Default=true. [PyxisVideoInputMonitoring] Issue 1 Rev 4 Output=17 This entry specifies which output on the router is used for checking the signal lock on the inputs. Each input is routed to this output in turn and if the output obtains a signal lock then the input is deemed to have a valid input signal. This feature enables input signal presence monitoring without dedicated hardware. This value must be a valid (and unused) output port on the router. To disable the Video Input monitoring feature completely set this value to 0. FirstInput=1 This entry specifies the first input port on the router that input signal monitoring is enabled for. This is the first input that is routed to the output port listed above for monitoring purposes. This value must be a valid input port on the router. Page 198 © 2013 Snell Limited