ASAHI AV VALVES
Installation, Operation and Maintenance Manual
(6) Installation procedure
Caution
- Avoid excessive tightening. (The valve can be damaged.)
- Do not use the pipe wrench. (The valve can be damaged.)
- Make sure that the threaded connections are plastic x plastic. (Metallic thread can. cause damage)
- Wrap the threaded joints on our plastic piping with sealing tape. Using a liquid sealing agent or liquid
gasket may cause stress cracks (Environmental Stress Cracking). Our product warranty shall not
apply in case of said use, even when said use is unavoidable.
Lab Cock has 15 kinds of products, with combinations of male thread, female thread and hose, and different sizes.
There are explanations about each connector as following;
Male Threaded type
Necessary items
● Sealing tape
● Strap wrench
Procedure
1) Wind a sealing tape around the male thread connector, leaving the end (about 3mm) free.
2) Tighten it to the female thread of the joint by hand.
3) Using a strap wrench, screw in the end connector by turning 180°- 360°carefully without damaging it.
Female Threaded type
Necessary items
● Sealing tape
● Strap wrench
Procedure
1) Wind a sealing tape around the male thread of joint, leaving the end (about 3mm) free.
2) Tighten the male thread of the joint and the female thread connector lightly by hand.
3) Using a strap wrench, screw in the end connector by turning 180°- 360°carefully without damaging it.
Hose type
○ Use hoses with the bore size 12-15mm to connect to the valve.
○ Push in by hand, not by any tools. The hose may come off when the working pressure rises over the maximum.
Lab Cock
5