Download 1. - Omron
Transcript
user.book 161 ページ 2011年5月20日 金曜日 午後2時57分 SECTION 8 Appendices First word allocated to Unit in DM Area: m = D20000 + (100 × 0) = D20000 DM address D20000 Meaning Contents 1 0 D20001 0 15 0 14 13 12 UID Addition Setting 11 10 9 8 7 Test Mode Disable Setting 0000 6 5 4 Setting for Write Verification 3 2 1 0 Tag Communications Speed Setting Auto Wait Time Setting First word allocated to Unit in CIO Area: n = CIO 2000 + (10 × 0) = CIO 2000 Word address CIO 2001 Meaning Contents 0 0 0 15 0 14 13 12 11 10 9 8 7 6 5 4 Communications specification Command code CIO 2002 00 10 First read address CIO 2003 00 0A Number of read bytes CIO 2004 10 00 Read data storage location (rightmost 4 digits) CIO 2005 CIO 2006 0 0 00 00 00 Data storage area Bank specification (Always 0) 3 2 1 0 Data order Read data storage location (leftmost 2 digits) --- ---: Ignored. SECTION 8 Sample Programming RFID System User's Manual 161