Download 1. - Omron

Transcript
user.book
67 ページ
2011年5月20日 金曜日 午後2時57分
SECTION 4
Data Exchange with the CPU Unit
DM Area Contents (Same for Run or Test Mode)
The following initial settings are set in the words allocated in the DM Area.
DM Area address
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11, or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12 or
CJ1W-V680C12
Bit No.
Type
UID Addition Setting
Test Mode Disable Setting
0: Enabled
1: Disabled
p. 93
04 to 07
Setting for Write Verification
0: Verification
1: No verification
p. 94
00 to 03
Tag Communications Speed
Setting
0: Normal mode
1: High-speed mode
p. 94
00 to 15
The ID Tag timeout time
when the Communications
Specification is single auto or
repeat auto. An ID Tag
Missing Error will be
returned if this value is
exceeded.
0001 to 9999 (×0.1s)
0000: Infinite
p. 95
m+100
m+102
m+3
m+4
m+103
m+104
Auto Wait Time
Setting
08 to 15
Not used.
Write Protection
00 to 07 Disable Setting
Write Protection Disable
(V680 method/Disabled/
V600 method)
04 to 15
Not used.
Antenna Connection
00 to 03 Setting
Antenna Connection
04 to 15
Not used.
Results Monitor
00 to 03 Output Setting
--p. 95
---
---
0: Standard Antenna
1: V680-H01
p. 96
---
---
Results Monitor Output
0: Communications time
1: Noise level
Test Operation
00: Communications test
A0: Distance level
B0: Read speed level
B1: Write speed level
C0: Noise level
C1: Communications
success rate
00 to 07
Test Antenna
01: Antenna 1
02: Antenna 2
0000 to 0800 hex (bytes)
08 to 15
m+50
--00: V680 method
01: Disabled
02: V600 method
Test Settings
(Both Antennas 1 and
2)
---
Initial Settings Data
m+2
System Settings
SECTION 4
m+101
Reference
p. 93
08 to 11
m+1
Setting
0: Disabled
1: Enabled
12 to 15
m
Description
p. 96
p. 97
m+51
---
00 to 15
Number of Test Bytes
---
04 to 15 Run/Test Switching
Method Setting
00 to 03 (Both Antennas 1 and
2)
Not used.
m+80
---
04 to 15 Tag Memory Setting
(Both Antennas 1 and
00 to 03 2)
Not used.
m+81
Tag Memory Setting
04 to 15
Not used.
m+90
---
Data Transfer Setting
(Both Antennas 1 and
00 to 03 2)
Run/Test Switching Method
Setting
Data Transfer Setting
--0001: CPU Unit
0000: Test switch
--0: Standard Mode
1: CA1D Mode
--0: Use cyclic transfer
1: Use Intelligent I/O
Instructions
p. 98
• First word allocated to Unit in DM Area: m = D20000 + 100 × Unit number
RFID System
User's Manual
67