Download 1. - Omron
Transcript
user.book 67 ページ 2011年5月20日 金曜日 午後2時57分 SECTION 4 Data Exchange with the CPU Unit DM Area Contents (Same for Run or Test Mode) The following initial settings are set in the words allocated in the DM Area. DM Area address Antenna 1 of CS1W-V680C11, CS1W-V680C12, CJ1W-V680C11, or CJ1W-V680C12 Antenna 2 of CS1W-V680C12 or CJ1W-V680C12 Bit No. Type UID Addition Setting Test Mode Disable Setting 0: Enabled 1: Disabled p. 93 04 to 07 Setting for Write Verification 0: Verification 1: No verification p. 94 00 to 03 Tag Communications Speed Setting 0: Normal mode 1: High-speed mode p. 94 00 to 15 The ID Tag timeout time when the Communications Specification is single auto or repeat auto. An ID Tag Missing Error will be returned if this value is exceeded. 0001 to 9999 (×0.1s) 0000: Infinite p. 95 m+100 m+102 m+3 m+4 m+103 m+104 Auto Wait Time Setting 08 to 15 Not used. Write Protection 00 to 07 Disable Setting Write Protection Disable (V680 method/Disabled/ V600 method) 04 to 15 Not used. Antenna Connection 00 to 03 Setting Antenna Connection 04 to 15 Not used. Results Monitor 00 to 03 Output Setting --p. 95 --- --- 0: Standard Antenna 1: V680-H01 p. 96 --- --- Results Monitor Output 0: Communications time 1: Noise level Test Operation 00: Communications test A0: Distance level B0: Read speed level B1: Write speed level C0: Noise level C1: Communications success rate 00 to 07 Test Antenna 01: Antenna 1 02: Antenna 2 0000 to 0800 hex (bytes) 08 to 15 m+50 --00: V680 method 01: Disabled 02: V600 method Test Settings (Both Antennas 1 and 2) --- Initial Settings Data m+2 System Settings SECTION 4 m+101 Reference p. 93 08 to 11 m+1 Setting 0: Disabled 1: Enabled 12 to 15 m Description p. 96 p. 97 m+51 --- 00 to 15 Number of Test Bytes --- 04 to 15 Run/Test Switching Method Setting 00 to 03 (Both Antennas 1 and 2) Not used. m+80 --- 04 to 15 Tag Memory Setting (Both Antennas 1 and 00 to 03 2) Not used. m+81 Tag Memory Setting 04 to 15 Not used. m+90 --- Data Transfer Setting (Both Antennas 1 and 00 to 03 2) Run/Test Switching Method Setting Data Transfer Setting --0001: CPU Unit 0000: Test switch --0: Standard Mode 1: CA1D Mode --0: Use cyclic transfer 1: Use Intelligent I/O Instructions p. 98 • First word allocated to Unit in DM Area: m = D20000 + 100 × Unit number RFID System User's Manual 67