Download Specifications for Atkinson
Transcript
Heating Upgrade for Atkinson Hall Georgia College & State University Milledgeville, Georgia D. Application Equipment: Brushes, rollers, spray apparatus and similar application equipment are not required to be new, but they shall be capable of producing the required results specified hereinafter. E. Thinners: Only those recommended for that purpose by the manufacturer of the material being installed. PART 3 - EXECUTION 3.1 INSTALLATION A. Surface Preparation: 1. 2. 3. 4. 5. B. General: Do not begin painting on any surface until it has been inspected and is in condition to receive the paint as specified herein. Should any surface be found unsuitable to produce a proper paint finish, the Engineer shall be notified in writing and no material shall be applied until the unsuitable surfaces have been made satisfactory. Absence of such notification shall be construed as acceptable of such surface to receive paint. Later claims of defects in surfaces prior to painting shall not relieve the Contractor from his responsibility for compliance with the requirements of the Specifications. Steel and Iron: Remove grease, dirt, mud, rust and scale. Touch up any chipped or abraded places on items that have been shop coated. Where steel and iron have a heavy coating of scale, it shall be removed by de-scaling or wire brushing to produce a smooth surface for painting. Masonry: Masonry surfaces to be painted shall be prepared by removing all dirt, dust, oil and grease stains, mortar droppings, and efflorescence. Exposed pipes and conduit shall be cleaned using mechanical cleaning and/or solvents, mineral spirits or other paraffin-free solvents having a flash point no higher than 100 degrees F. and shall be painted in accordance with the Painting Systems Schedule. Hardware, hardware accessories, lighting fixtures, switch and outlet plates, in place and not to be painted shall be removed prior to surface preparation and painting operations or protected. Following completion of painting of each space, removed items shall be reinstalled. Application and Instructions: 1. 2. 3. 4. The proportions of all ingredients in all paints and stains mixed on the site shall be in accordance with the recommendations of the paint manufacturer printed on the container applicable to the particular use for which the specific mixture is intended. No thinner or flattening oil will be used in the last coat. Screen out all lumps and impurities during mixing using clean containers, and protect against dirt or trash entering the mix. Stir until uniform consistency is procured. During the actual application and drying of the paint, and until normal occupancy of the building occurs, a minimum temperature of 65 degrees F. shall be maintained. This temperature shall be held as constant as possible to prevent condensation. Do not apply exterior paint in damp rainy weather or until the surface has dried thoroughly from the effects of such weather. Surface to be stained or painted shall be clean, dry and smooth. Each coat of paint shall be smoothly applied, worked out evenly and allowed to dry before the subsequent coat is applied. 09900 - 2