Download User Manual - Oasys Software

Transcript
Flow
4.3.3.6.4 Flow Count
Flow count graphs can be created to measure the number of agents performing specified transitions
during particular time intervals (bins).
Groups in a flow count graph are composed of one or more transitions. Each graph can be
configured to produce multiple series showing the flow counts for each of the selected transitions
independently, or one series showing the flow count treating all selected transitions as a single
combined transition.
If a group of transitions is created under a filter, only agents satisfied by that filter will be included in
the associated counts. Note the distinction between using a filter such as 'holding token' versus 'are
ever holding token'. In the first case, agents will be included in the flow count only if they are holding
the specified token while crossing the specified transition. In the second case, agents will be
included in the flow count as long as they ever held the specified token at some point during the
reporting period.
Flow Count Parameters
Name
The name of the graph.
Simulation
run
The simulation run for which counts should be calculated. To compare flow counts
between different runs, a composite graph can be used.
Reporting
period
The time period over which counts should be calculated.
Title
Graph title (will be included in exported images and CSV files).
X axis
X axis label (will be included in exported images and CSV files).
Y axis
Y axis label (will be included in exported images but not CSV files).
Style
Flow counts can be displayed as either curves, stepped curves, stacked areas,
stepped stacked areas, bars, or stacked bars.
If stepped curves, stepped areas, bars or stacked bars are chosen, a bin size
must be specified. Each stepped portion or bar will then correspond to an interval
of time with the size specified, and the associated value will be the total flow
during that time interval. If sampling period exceeds bin size, zero values will be
present.
If stacked areas, stepped areas or stacked bars are chosen, a 'Normalized' option
is available. If selected, flow counts will be displayed as percentages instead of
absolute values and will always sum to 100.
Curves and stacked areas use a single frame as the interval and are therefore
difficult to read, but may useful when exported to CSV for further analysis.
136
Show
Legend
Display graph legend (will be included in exported images but not CSV files).
Graph must be regenerated to update dataset labels.
Show
Metadata
Display information about the MassMotion version and database file used to
generate the graph (will be included in exported images and CSV files).
Notes
A simple field that can be used to save comments or explanation about the graph.