Download 7i76 manual
Transcript
REFERENCE INFORMATION LBP LOCAL LBP WRITE COMMANDS (HEX), all of these commands except 0xFF expect a single byte of data. 0xE0 Reserved 0xE1 Set LBP status (0 to clear errors) 0xE2 Set CRC check enable (Flag non-zero to enable CRC checking) 0xE3 Set CRC error count 0xE4 .. 0xE9 Reserved 0xEA Set Enable_RPCMEM access flag (non zero to enable access to RPC memory) 0xEB Set Command timeout (in mS for USB and character times for serial) 0xEC .. 0xEF Reserved 0xF0 .. 0xF6 Reserved 0xF7 Write LEDs 0xF8 Set low address 0xF9 Set high address 0xFA Add byte to current address 0xFB .. 0xFC Reserved 0xFD Set unit ID (serial only) 0xFE Reset LBP processor if followed by 0x5A 0xFF Reset LBP parser (no data follows this command) 7I76 45