Download Power, Test and Measurement

Transcript
2105
Technical portal and online community for Design Engineers - www.element14.com
Insulation and Continuity Testers
Insulation / Continuity Tester with Multimeter
functions
MIT400 Series
General features:
Ì Insulation testing to
1000V and to
200GΩ
Ì Continuity testing at 200mA down to 0.01Ω
Ì Analogue and dual digital display
Ì PI/DAR insulation timer / display
Ì Bluetooth data transfer
Ì TRMS voltage measurement and test data
storage
Ì IEC61010-1 CATIV 600V
W=108 H=232 D=55mm. Weight 800g
Industrial Applications: service, maintenance and electrical installations testing.
Ì MIT400: Basic CATIV 600V tester
Ì MIT430: Advanced CATIV 600V tester, results storage and Bluetooth download
Instrument
MIT430
Ì
Ì
Ì
20GΩ
Ì
Ì
Ì
Ì
Ì
Ì
200GΩ
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
380955.381287
Price Each
Ì
Ì
HITESTER 3454-11
Ì
3+
5+
875.00
831.25
809.34
´
´
S
N
Installation Testers
1650B Series
1652B
1651B
1653B
The 1650B series tests continuity, insulation resistance, loop impedance, short-circuit current
(PSC), RCDs and more.
1651B: Performs all basic intallation tests including continuity, loop and line resistance,
PFC/PSC (short-circuit current), RCD tripping time.
1652B: As 1651B plus RCD tripping current level, automatic RCD test sequence, test DC
sensitive RCDs.
1653B: As 1652B but with earth resistance and phase sequence measurement. Has internal
memory and a PC interface for documentation and reporting.
Ì Easy: simply turn knob, press the button and see results
Ì Efficient: measure loop impedancewithout tripping RCDs, eliminating the need to bypass them
Ì Rugged: withstands a one-meter drop for demanding field use
Ì Safe: slim probe with test button keeps your eyes on the panel while probing hard to
reach points
Ì Comfortable: compact and lightweight (less than 1.2kg) for all day testing
Ì Compliant: meets all relevant standards including EN 61557 and BS 7671 16th Edition
IEE wiring regulations
Ì Current: High current loop impedance test
Ì Extra: Includes Zero Adapter for easy test lead compensation.
1651B
Supplied with: red/black silcone lead set with clips, protective rubber boot, remote switch
probe (except MIT400) and batteries.
419195.428557
Mftrs.
1+
842-1439
Price Each
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Order Code
Standard Calibration Charge
General Accuracy (at 20°C)
Insulation
±3% ±2 digits (up to 10MΩ)
±5% (up to 100MΩ)
±30% (up to fullscale)
Continuity
±3% ±2 digits (0.01 to 100Ω)
Resistance
±5% ±2 digits (10Ω to 1MΩ)
Voltage
±1% ±2 digits (max. 600V ac or dc)
Frequency
±2% ±2 digits
mV
±2% ±2 digits
mA
±2% ±2 digits
Capacitance
±5% ±2 digits
General Specifications
Batteries
6 x AA (alkaline or NiMH) gives 3000 consecutive tests of any type.
Protection
IP54
Operating Temperature
-10°C to 55°C
Safety
IEC61010-1 600V CATIII (MIT430 is 600V CATIV)
List No.
3454-11
250V, 500V, 1000V
4 to 4000MΩ
0.2 to 200MΩ
0 to 4000MΩ
1st effective range: ±3 %rdg. ±4 dgt. / 2nd effective range: ±5 %rdg. ±5 dgt.
Not more than 1.2 x rated measurement voltage
1.2 mA max
∞ to center, ∞ to 0 MΩ within 5s
40Ω to 4MΩ short circuit current: 200 mA
±3 %rdg. ±6dgt. (±5 %rdg. ±6dgt. at 400 kΩ range or higher)
0 to 750V
±3 %rdg. ±6dgt. (up to 600V)
Mftrs. List No.
Insulation Voltage Range
50V (10GΩ)
100V (20GΩ)
250V (50GΩ)
500V (100GΩ)
1000V (200GΩ)
Insulation Range
Leakage Current Display
INS test voltage display
Continuity
0.01 to 100Ω
Variable Current Limit (200mA/20mA)
Fast Buzzer - selectable threshold
kΩ range to 999kΩ
Voltage
Live circuit warning at 50V
Default voltmeter
TRMS measurement to 600V
Measurement Ranges
Frequency (40 to 400Hz)
Capacitance (0.1nF to 10μF)
mV / transducer (0.1 to 19.99V)
Features
Backlight
Battery condition display
Insulation timed PI-DAR tests
Test button / Lock button
Limit alarm pass band on INS
Auto power down
Result Storage
Bluetooth Connectivity
Description
H=148, W=175, D=56mm Weight = 530g
Insulation test voltage
Measurement range
1st effective range
2nd effective range
Accuracy
No load voltage
Short circuit current
Response time
Low resistance range
Accuracy
AC voltage range
Accuracy
Price Each
Order Code
1+
2+
5+
Industrial Insulation Tester MIT430-EN
108-6225
1,497.07
1,467.14
Price Each
1,437.78
Standard Calibration Charge
UKAS Calibration Charge
S
N
´
´
Prices are in Australian dollars, GST exclusive and correct as at 1/02/2011.
Measurement functions
Voltage and Frequency
Wiring polarity
Insulation Resistance
Continuity
Loop & Line Resistance
PFC/PSC (short-circuit current)
RCD tripping time
RCD tripping current level
Automatic RCD test sequence
Test DC-sensitive RCDs
Earth Resistance
Phase Sequence Indicator
Other features
Self-test
EN61557*/VDE0413 compliant
Illuminated display
Line voltage indicator
Battery indicator and battery test
Memory, Interface
Memory (500 measurements)
Computer interface
Time stamp (with FlukeView Forms)
Software
1652B
Ì
Ì
Ì
Ì
500, 1000V 250, 500, 1000V
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
ramp test
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
35
Test & Measurement
MIT400
These multimeters not only offers voltage,
resitance and continuity measurements for
basic fault finding but also perform insulation tests over a range of voltage levels.
Ì Easy-to-read digital display
Ì Auto-discharge
Ì Live-wire warning
Ì Safety system for high voltage measurement
Ì Sliding cover
Ì 3454-11 has insulalation volage range
of 250V, 500V and 1000V
Power, Test and Measurement
Combining the latest range of measurement
techniques with new instrument design to provide a state-of-the-art tester that is compact and
comfortable to hold. All primary results are displayed in the larger digital display and repeated
on the analogue arc. Additionally, auxiliary test
information such as frequency, leakage current,
Insulation or circuit voltage is displayed in the
smaller secondary digital display. Rubber over
moulding combines the tough shock absorbing
outer protection with excellent grip, on a strong
modified ABS housing, providing an almost indestructible case.
3454
1653B
Ì
Ì
50, 100, 250, 500, 1000V
Ì
Ì
Ì
Ì
Ì
ramp test
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Option
Email: [email protected]
2105