MD320/MD320N User Manual
Parameter Description
Input phase failure
Factory default
protection selection
value
1
Select whether to provide protection for
input phase failure. Only the MD series
F9-12
Setup range
0:Inactive
1:Active
inverter of G model with over 18.5kW can
have input phase loss protection function,
and the P model with 18.5kW has not
such function no matter whether F9-10 is
set to 0 or 1.
F9-13
Output phase failure
Factory default
protection selection
value
Setup range
1
0:Inactive
Select whether to provide protection for
1:Active
output phase failure.
F9-14
First fault type
F9-15
Second fault type
F9-16
Most recent fault type
0~24
It is used to record the fault types of inverter for the most recent three times: 0 indicates no
fault, while 1 to 24 indicates ERR01 to ERR24. Refer to Chapter 7 for details.
Frequency upon
F9-17 fault
F9-18
F9-19
Current upon
fault
Display the frequency upon fault for the most recent one time.
Display the current upon fault for the most recent one time.
Bus voltage
upon fault
Display the bus voltage upon fault for the most recent one time.
141