Download ESIM022
Transcript
Enable temperature sensor and set MIN and MAX temeprature thresholds and name View MIN and MAX thresholds View temperature sensor name and temperature value SMS SMS text message content: TEMPt1mnn:mxx:temp-name Value: mnn – MIN temperature threshold, range [-55... 125] C; mxx – MAX temperature threshold, range - [-55... 125] C; temp-name – up to 8 characters temperature sensor name. Example: TEMP1:-14:32:House Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS Config Tool SMS text message content: STATUS Example: STATUS This operation may be carried out from the PC using the ELDES Configuration Tool software. To stop Temperature Info SMS sending, please disable the temperature sensor. To disable it, please refer to the following configuration methods. Disable temperature sensor SMS Config Tool ESIM022 User manual v1.0 SMS text message content: TEMP1:OFF Example: TEMP1:OFF This operation may be carried out from the PC using the ELDES Configuration Tool software. 21