Setup software (version PROFIBUS)
Version 04/08
2.4.3 Screen page «Next motion task»
No. Motion task
Displays the current motion task number.
No. Next motion task
Displays the number of the next motion task. On completion of the present
task, the next motion task is automatically started, meeting the following
conditions:
Start condition
Immediately:
reached.
The next task is started as soon as the target position is
I/O:
The next task is started by a signal at a digital input
«Start_MT Next» (terminal X3).
Condition:
Target position must have been reached.
You can preselect the logic with the “Start with” parameter.
Time:
The next task is started with a specified delay after the target
position has been reached. You can enter the delay time via
the “Delay time” parameter.
I/O or time
The next task is started by a signal at a digital input
«Start_MT Next» (terminal X3) or by a specified delay. The
event that occurs first (the start signal or the end of the delay
time) provides the trigger.
Condition: The target position must have been reached.
You can preselect the logic with the “Start with” parameter,
and enter the delay time with the “Delay time” parameter.
Start with
Logic for the digital input (terminal X3) that has the function «Start_MT Next»
Low level:
0...7V
High level:
12...30V / 7mA