Download C-DOT DSS MAX - C

Transcript
EQUIPAGE OF ISTU
•
EQUIP-FRAME with the following parameters.
MOD-NO
=
BM Number
RACK-NO
=
1
FRAME-NO
=
1/2/3
TIC-ID
=
TIC ID of the frame to be equipped e.g.Ti01 or Ti05
or Ti09
FRAME-TYPE
=
ITU
Execute
The command will equip ISTU
•
Check the status of ICC and TIC cards. The status of these controller cards will
be OOS-OPR. Do the diagnostics on ICC cards and bring them in service
ACT/SBY. Then do the diagnostics on TIC cards and bring them in-serviceACT/SBY.
Note:
•
For Diagnostics of ‘TIC’, ICC must be inservice.
Now line cards (BRL,PRL) cards can be equipped using the command
EQUIP-TRML-CARD with the following parameters.
•
HW-TYPE
:
The values are BRI, PRI, PRI-16
Ver-No.
:
1
Card-Slot
:
BM-No.- Rack No.-Frame No.- Slot-No.
Now make the trml equipped inservice by the command.
PUT-TRML-CARD-INS
The card will be brought inservice after diagnosis. You can also use the FRCTRML-ARD-INS command where by dgn of the card will not be done but will
be directly brought in-service.
4.2.
4.2.1
DATA CREATION FOR AN ISDN SUBSCRIBER
A typical example of creation of ISDN subscriber.
Give MMC command ‘cre-sub’.
DIRNO.
:
a free dirno. to be given
TEN
:
a free ten from the slot equipped as BRI
ISDN USER MANUAL
21