Transcript
en Malfunctions Malfunction Possible causes Troubleshooting Main switch switched off t or main switch (key) No power supply t Connect the power plug into the wall socket. Power supply cord fault Machine does not run Motor not turning Main switch fault Machine not in working position Electronical-suction brush is not turning Page 6 t Call for technical service On the first page of these instructions of use t Call for technical service On the first page of these instructions of use t Call for technical service On the first page of these instructions of use t Place machine in working position 7 t Drive mechanism fault Motor runs but not tool t Call for technical service Soiled motor protection filter t Clean / replace the Motorprotection filter Hose or dust nozzle blocked (e.g. pieces of wood, paper, textile) t Remove the blockage Double-filter paper sack full (indication double-filter paper sack full) t replace The lid of the suction aggragate was not attached properly t check Tube was not inserted properly t check 6 accessories not mounted properly t check 8 moisture accumilation t replace double-filter paper sack Moist double-filter paper sack t Store in a dry room On the first page of these instructions of use Poor vacuum performance Odor development 10 9 10 Technical data Machine tapiset 38 tapiset 45 TR4 + TR4.1 TR4 + TR4.2 Rated voltage 120V~/230V~ 120V~/230V~ dc Frequenz 50/60 50/60 Hz Rated power 900 920 W machine weight 7.4 7.8 kg Dimensions (L x W x H) 260x380x1200 260x450x1200 mm Assessed sound level LPA according to EN 60704-1 69 67 dB(A) Electrical protection class II II Typ 15