Download User Manual for COP8-REF-AME
Transcript
Description Reference design for COP8AME File User Manual COP8-REF-AME Prepared Checked BC MK Status Proposal Rev Project no. Scale Date Page x of x 04-12-01 8.12 Convert_Temp Convert_Temp Convert AD value into voltage Calculate temperature accordingly to equation: é mV ù Vout [V ] = −8ê ú * T [°C ] + 1.625[V ] ë °C û Binary to BCD (Bin_Dec) This routine converts value read from AD converter into value in °C units. It is up to user to write code that will handle appropriate accuracy. At the end temperature value is converted into separate digits displayed on LCD. Location: mathpack.inc Exit a brand new world Page: 25 25 of 26