Download Fastech Sect 1.qxd
Transcript
FASTECH Allow the extinguishant to soak for 15 minutes after it discharges. With a portable fire extinguisher in your hand, cautiously inspect for damage. Avoid breathing fire vapors or fumes. CAUTION Overboard discharge of waste water should only be used in approved areas. It is your responsibility to comply with local regulations regarding the discharge of waste. You could be fined if your boat has an operable overboard discharge system. Removing the handle of the seacock while in the closed position or disabling the system by other means may be required to avoid a fine. RAW WATER SYSTEM Your Formula boat may have as many as two accessory components (generator and air conditioning) - in addition to the engines - with complete raw water systems. Each raw water system will have its own thru-hull water intake, seacock and strainer. The seacock is very important. It protects the boat from sinking if a hose or fitting should fail. It is important to close any seacock not in use. Waste water from the generator is routed with the generator’s exhaust system. Waste water from the air conditioning unit is directed overboard through a drain port in the hull. Your engines have their own raw water system for cooling. Refer to the propulsion unit operator’s manual for engine cooling information. FOR021 AUTOMATIC FIRE EXTINGUISHER SYSTEM Automatic Fire Extinguisher Figure 5-16 A fixed automatic fire extinguisher that uses FE-241 (FM-200 for European requirements) as an extinguishing agent is mounted on the engine compartment forward bulkhead. The extinguisher is activated when the heat sensitive head reaches a predetermined temperature. The extinguisher discharges and saturates the engine compartment, smothering the fire. When the fire extinguisher discharge occurs, turn OFF all engines, bilge blowers and electrical system components. Refrain from opening the engine compartment hatch, as the introduction of oxygen could accelerate any fire present there. 5-12 Refer to Automatic Fire Extinguisher Indicator, in Section 4, for information on the automatic fire extinguisher monitoring indicator. EQUIPMENT Boarding Ladder—The boarding ladder is mounted on the swim platform at the stern of the boat. In most applications, a fiberglass lid covers the stowed ladder. Lift this lid to access the ladder. FASTECH FORMULA