Download AMPView - AMPS Technologies
Transcript
AMPView The Model>Condition>UserDefinedLoad >New Type+Value This will create a new Type Name and save the current data entered this page into the condition new Type Name condition set. This is a quick way of creating a new Type Name if the user has not created a new Type Name in the previous Type page. The Model>Condition>UserDefinedLoad >Update This will save the entered data and updates the database of the current active Type Name as shown in the Name field. The OverSet Condition The OverSet boundary condition is an advanced condition set that is mainly used for large deformation motion such as bullet penetrating through air or bubble rising in a pond type application. In such cases, a finite element group (OverSet Entity) is moving across another finite element group (OverSet Domain). The user must specify the OverSet type and select the proper geometry association. It can also be used as the traditional VOF (volume of the fluid) method specification for applications such as bubbling in water. In such case, the air bubble is the OverSet Entity, and the water is the OverSet Domain. The problem is extremely nonlinear due to the geometric constraint and fluid-solid interaction on the interface. To use this feature, please contact technical support for further assistance. The Model>Condition>OverSet/VOF>Name This name is the same as the one have been created in the condition Type page. It is displayed here for information purpose. The Model>Condition>OverSet/VOF>New Type+Value 63