Download 90 SingleStage

Transcript
Downflow
Right Side Vent and Trap
Plastic Cap
Yellow or black
Trap Connection
"Clamp ears"
ointed OUT
_otate
downward
& Clamps
Relief
Black
Elbow Tube BlackRubber
1/2" ID & Clamps
(Loose Parts
Vent Drain
Barbed Coupling
1/2" OD
(Loose Parts Bag)
NOTE_. Built-in channel will
Pressure
Switch
Detail
Dual
Pressure
3/16" ID
DrainTube
Black Rubber
112"ID
Cut to Fit &
be angled 5° to 10° also.
Single
Preassemble &
insert into furnace
Tube
Rubber
Coupling & Clamps
Switch
On Some
Models ONLY
2" PVCCoupling
Either:The PVC
supplied 2" PVC Tee
TeeTrap White PVC
Drain TubeCorrugateds/8"ID & Clamps
WARNING
Move Caps to top of trap
/
/
DrainConnector Black _-
©
PVC3/4"PVC X 112"CPVC
(Looseparts bag)
DrainTube Black Rubber,
5/8" ID Cut to fit & Clamps
(loose parts bag)
25-24-83a
Downflow
Remove
Right
the Drain
Disconnect
Side
Vent and
Trap
(See Figure 14)
Tee if installed.
the hoses
Install
from the Trap assembly,
and remove
Trap
and Trap mounting bracket from the blower compartment.
Using
cover plate and gasket provided in the loose parts bag, cover the
hole from the burner compartment
secure with screws.
to the blower
compartment
and
Move the caps to the top of the Trap and mount the Trap externally
to the right side of the unit using the 2 screws provided.
Connect
the corrugated
Drain
Tube from the transition
Connect
the drain
Secure
all connections
with clamps.
hose from the Vent Drain to the Trap.
into the casing
Cut an appropriate
length of 2" PVC pipe long,
cabinet and connect the vent drain to either:
•
A standard
•
A 2" PVC coupling
models)
Install
field
supplied
Tee Trap into bottom
enough
2" PVC tee (N9MP1
fastened
section
onto
the Drain
to exit the
models),
or
Tee (*9MPD
of Tee.
box to the
Trap as shown. If an extension is required, use the black PVC tube
connector and the black 5/8" ID Drain Tube in the loose parts bag.
Cut tube to length.
the vent pipe grommet
If an ex-
Connect the Tee trap and the main drain line exiting
shown in Figure
19.
the casing
as
Note:
It is recommended
that all PVC piping and fitting connections be fit up and inspected
before final cementing.
Both the ex-
tension is required, use the black 1/2" OD barbed coupling, connect a black 1/2" ID elbow tube and a suitable section of a 1/2" ID
ternal Trap and the external
Tee Trap must be primed
before
operation.
Verify all condensate
drain connections
are securely
drain tube to make connection
from the vent drain
cure all connections
with clamps.
clamped.
installed
44001 102102
to the trap. Se-
A coupling
and clamps
(in loose part bag) may
as shown for future servicing
of the vent system.
[_
be