Download 90 SingleStage
Transcript
Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipes from freezing. Instruct them on a service agency to call to provide service, if required. FrozenWater Pipe Hazard WATER DAMAGE TO PROPERTY HAZARD -or- Failure to protect against the risk of freezing result in property damage. may Do not leave your home unattended for long periods during freezing weather without turning off water supply and draining water pipes or otherwise protecting against the risk of frozen pipes and resultant damage. Your furnace is designed solely to provide a safe and comfortable living environment. The furnace is NOT designed to ensure that 3. Winter Shutdown If you go away during the winter months and do not leave the heat on in your home, the plastic transition box and the condensate trap on the furnace must be protected from freeze damage.(See Figure 10 trough Figure 19) 1. water pipes will not freeze. It is equipped with several safety devices that are designed to turn the furnace off and prevent it from restarting in the event of various potentially unsafe conditions. If your furnace remains off for an extended time, the pipes in your home could freeze and burst, resulting in serious water damage. If the structure will be unattended take these precautions. 1. during cold weather Turn off the water supply to the structure you should and drain the water lines if possible and add an antifreeze for potable water to drain traps and toilet tanks. Open faucets in appropriate areas. -or- Install a reliable remote sensing device that will notify somebody of freezing conditions within the home. Disconnect the 5/8" OD rubber hose from the vent drain fitting that is located downstream of the combustion blower. Insert a funnel into the hose and pour four(4) ounces of sanitary type (RV) antifreeze into the condensate trap. Reconnect the 5/8" OD rubber hose to the stub on the vent drain fitting. 2. Secure Disconnect with the hose clamp. the 3/4" OD rubber hose from the condensate trap. Insert a funnel into the hose and and pour four(4) ounces of sanitary type (RV) antifreeze into the plastic Transition box. Squeeze the hose together near the end and quickly reconnect the 3/4" OD rubber hose to the stub on the condensate trap. Secure with the hose clamp. When you return home, your furnace not necessary to drain the antifreeze will be ready to start, as it is from the furnace. 2. Installation Typical Upflow Installation CARBON MONOXIDE POISONING HAZARD Aluminum Failure to properly vent this furnace or other appliances could result in death or personal injury. This furnace can NOT be common vented or connected to any type B, BW or L vent or vent connector, nor to any portion of a factory-built or masonry chimney. If this furnace is replacing a 3reviously common-vented furnace, it may be necessary to resize the existing vent and chimney to 3revent oversizing problems for the other remaining appliance(s). See Venting and Combustion Air Check in Gas Vent Installation section. This furnace MUST be vented to the outside. or non-rusting Vent Termination 8" Min. _1 _[_nlet 20Max in same atmospheric _ _ Shielding Pipe(not used on Single shield recommended. (See for dimensions). Couplingon ends of exhaust pipe.Total _pipe & coupling out- Pipe model) zone Vent PipesMUST be ' in. supportedHorizonta]l and Vertically _atmosphedc' ax. Location and Clearances 1, E_I Refer to Figure 1 or Figure 2 for typical installation and basic connecting parts required. Refer to Figure 5 for typical horizontal direct vent installation and basic connecting parts required. Supply and return air plenums and duct are also required. * Increase minimum from 8" to 18" for cold climates (sustained temperatures below 0 ° F). 25-23-33 44001 102102