10. Appendix C: Standard Configuration The configuration described below is the standard configuration used when implementing the LUFP1 gateway. This chapter mainly gives the user information about the performances obtained on the downstream Modbus network. It allows users to decide whether, for example, they should change the timing of periodic exchanges with one or more of the TeSys U motor starters (see Chapter 7 Using ABC-LUFP Configurator, page 61). 10.1. Configuring Modbus Exchanges The LUFP1 gateway carries out four types of exchanges with each of the 8 TeSys U motor starters. The first two exchanges are periodic and allow you to control and monitor the motor starter. The last two exchanges are aperiodic (triggered by a change in the values of the data to be transmitted to the motor starter) and allow you to read and change the value of any motor starter parameter. Function 16#03 16#10 Modbus function Read Holding Register Preset Multiple Registers Number of bytes (1) 11.5 + 10.5 14.5 + 11.5 (16#03) (Read Holding Register) 011.5 + 10.5 (16#06) (Preset Single Register) 11.5 + 11.5 Exchange between the LUFP1 gateway and the TeSys U motor starter Periodic reading (300 ms period) of the TeSys U motor starter’s status register (address 455 = 16#01C7) only Periodic writing (300 ms period) of the TeSys U motor starter’s status register (address 704 = 16#02C0) only Aperiodic reading of the value of a single parameter, for a single TeSys U motor starter at a time (function and address defined by the user) Aperiodic writing of the value of a single parameter, for a single TeSys U motor starter at a time (function and address and value defined by the user) (1) Number of bytes in the Query + number of bytes in the Response, plus a silence time of 3.5 characters for each of these two frames (see description of the “Message delimiter (10ms)” parameter in Section 7.12.3 “Sub-Network” Element, page 93). Each byte will be transmitted in the form of a group of 10 bits (8 data bits, 1 start bit and 1 stop bit). These values allow you to calculate the approximate amount of traffic on the downstream Modbus network as follows: Volume of periodic traffic (300 ms period) ..................... [ (11.5 + 10.5) + (14.5 + 11.5) ] * (8 + 1 + 1) = 480 bits For 1 TeSys U motor starter ................................................................ 1 * 480 * (1 000 ÷ 300) = 01,600 bits/s For 8 TeSys U motor starters............................................................... 8 * 480 * (1 000 ÷ 300) = 12,800 bits/s As a result, on a network operating at 9,600 bits/s, you will need to considerably increase the cycle time for all or some of the periodic Modbus commands. On the other hand, at a speed of 19,200 bits/s (the default speed), the available bandwidth is sufficient to support acceptable communications, even with the occasional degraded mode (retransmission of frames), and to allow the use of aperiodic parameter exchanges. 111