The following screen is displayed:
DOSIS mL/L/MONTH
0000.0
0000.0
[OK]
[A] <
>[B]
There are two lines in the display: the one at the top expresses the memory value (by default, this is
zero) and the one at the bottom is the programming line where the desired value should be
entered.
 The value is set by moving from one figure to the other with A (left) and B (right) and increasing
or decreasing each flashing figure using the + and - buttons.
DOSIS mL/L/MONTH
0000.0
0020.0
[OK]
[A]
[B]
Example for 20mL/L/month:
Press 2 times on A and 2 times
on +
 Once the desired value has been set, press
to submit.
The chosen value is memorised and is copied into the line at the top:
DOSIS mL/L/MONTH
0020.0
0020.0
[OK]
[A]
[B]
N.B.: unless you submit, the value entered will not register.
 Once the dose has been programmed, press
to access tank setting:
15