Download SVFlux Tutorial Manual

Transcript
3D Multi Planar Example
51
of
62
between your original geometry and AC UMESH click on the SVSLOPE or AC UMESH icon
which appears below the toolbars on the top left hand side of the screen.
7.2
Results and Discussions
After the model has completed solving the user may view the results in the AC UMESH
software by pressing the AC UMESH icon on the process toolbar. The sliding mass is
displayed in the C AD for the selected calculation method. To switch between the results of
the different calculation methods, click on the drop down menu at the top of the screen and
select the method you would like to view. In order to view the sliding mass area more
clearly the user may edit the Slid ing M a s s Dis p la y Se tting s dialog:
1.
Select Slip s > Slid ing M a s s Dis p la y ... from the menu,
2.
Uncheck the Slid ing M a s s w ith Ex p lo s io n checkbox.
The analysis results in a factor of safety of 1.172 for the Spencer method.
The user may also plot the column information for a particular column chosen either in plan
view or from a vertical cross-section. The column information settings are set in the C o lum n
Info rm a tio n dialog. To access this dialog click the Slip s > C o lum n Info rm a tio n... menu item.
Once the C o lum n Info rm a tio n dialog is closed by clicking O K , the user may select a
particular column by clicking on it in the C AD. The details of the selected column will appear
in the C AD.