Download BRC1E62 - Stinson Air
Transcript
WIRED REMOTE CONTROLLER OPERATION MANUAL BRC1E62 Thank you for purchasing this product. This manual describes safety precautions required for the use of the product. Read this manual carefully and be sure you understand the information before using the product. Keep this manual where it is readily accessible after reading it through. If another user operates the product in the future, be sure to hand over this manual to the new user. Refer to the operation manuals attached to the indoor and outdoor units, etc. Contents 1 Notices Safety Precautions – Items to be Strictly Observed – ............................ 2 Button Location and Descriptions............................. 5 Names and Functions............................................... 7 Basic Operation (Use of Direct Buttons) Cool/Heat/Auto/Fan Operation ............................... 11 Dry Operation ......................................................... 15 Setback................................................................... 17 Ventilation Operation .............................................. 18 Setting the Cool/Heat Selection Eligibility............... 19 Key Lock................................................................. 21 Quick Reference Main Menu Main Menu Items .................................................... 23 Menu Manipulation Manipulating the Main Menu Screen ...................... 27 ,QGLYLGXDO$LUÀRZ'LUHFWLRQ...................................... 28 Quick Start (SPLIT system only) ............................ 30 Ventilation ............................................................... 32 Energy Saving Options........................................... 34 Schedule................................................................. 42 Filter Auto Clean ..................................................... 48 Maintenance Information ........................................ 49 &RQ¿JXUDWLRQ .......................................................... 50 Current Settings...................................................... 54 Clock & Calendar.................................................... 55 Language................................................................ 58 Maintenance Reset Filter Indicator .............................................. 59 Cleaning of Remote Controller ............................... 60 Reference Information Malfunction (Error) Code Display ........................... 61 After-sales Service ................................................. 62 Safety Precautions – Items to be Strictly Observed – 7KLVSURGXFWLVQRWLQWHQGHGIRUXVHE\FKLOGUHQRULQ¿UPSHUVRQVZLWKRXWVXSHUYLVLRQ &KLOGUHQVKRXOGEHVXSHUYLVHGWRHQVXUHWKDWWKH\GRQRWSOD\ZLWKWKHSURGXFW Read the safety precautions carefully for the proper use of the product. This manual classifies the precautions into WARNINGS and CAUTIONS. %HVXUHWRIROORZDOOWKHSUHFDXWLRQVEHORZ7KH\DUHDOOLPSRUWDQWIRUHQVXULQJVDIHW\ WARNING ,QGLFDWHVDSRWHQWLDOO\KD]DUGRXVVLWXDWLRQZKLFKLIQRWDYRLGHGFRXOG result in death or serious injury. CAUTION ,QGLFDWHVDSRWHQWLDOO\KD]DUGRXVVLWXDWLRQZKLFKLIQRWDYRLGHGPD\ result in minor or moderate injury. It may also be used to alert against unsafe practices. WARNING Do not install the remote controller by yourself. ,PSURSHULQVWDOODWLRQPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH Consult your local dealer. Do not modify or repair the remote controller. ,WPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH Consult your local dealer. Do not relocate or reinstall the remote controller by yourself. ,PSURSHULQVWDOODWLRQPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH Consult your local dealer. 'RQRWXVHÀDPPDEOHPDWHULDOVVXFKDVKDLUVSUD\RULQVHFWLFLGHQHDUWKH product. ,WPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH Do not wipe the product with benzine, thinner, chemical dustcloth, etc. The product may get discolored or the coating peeled off. 7KHXVHRIRUJDQLFVROYHQWVPD\FDXVHFUDFNLQJRIWKHSURGXFWHOHFWULFVKRFNVRUD¿UH 2 CAUTION Do not allow children to play with the remote controller. Accidental operation by children may result in health impairment. Do not disassemble the product. 7RXFKLQJWKHLQWHULRUSDUWVPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH Consult your local dealer for internal inspections and adjustments. Do not press the button of the remote controller with a hard, pointed object. The remote controller may be damaged. Do not pull or twist the electric wire of the remote controller. It may cause the unit to malfunction. 'RQRWRSHUDWHZLWKZHWKDQGVWRDYRLGHOHFWULFVKRFNVRUD¿UH Do not wash the remote controller. ,WPD\FDXVHHOHFWULFOHDNDJHDQGUHVXOWLQHOHFWULFVKRFNVRUD¿UH Do not locate the remote controller wherever there is a risk of wetting. ,IZDWHUJHWVLQWRWKHUHPRWHFRQWUROOHUWKHUHLVDULVNRIHOHFWULFOHDNDJHDQGGDPDJHWRHOHFWURQLF components. ,WPD\UHVXOWLQHOHFWULFVKRFNVRUD¿UH 3 4 Button Location and Descriptions 1. Mode Selector button 11. LCD (with backlight) 4. Up button 5. Down button 6. Right button 7. Left button 9. Operation lamp (Green) 8. ON/OFF button 3. Menu/Enter button 10. Cancel button $LUÀRZ6HWWLQJEXWWRQ %DVLFRSHUDWLRQLH212))2SHUDWLRQ0RGH$LUÀRZ5DWH$LU 9ROXPH)DQ6SHHG$LUÀRZ'LUHFWLRQDQG6HW7HPSHUDWXUHDUH manipulable directly by the above button. Advanced settings are manipulable from the Menu screen displayed by the Menu/Enter button. NOTE Do not press the buttons on the remote controller with a hard, pointed objects. Otherwise, the remote controller may be damaged or malfunction. 5 1. Mode Selector button Use to select the operation mode of your preference. (Refer to page 11.) * $YDLODEOHPRGHVYDU\ZLWKWKHFRQQHFWLQJ model. 2. $LUÀRZ6HWWLQJEXWWRQ 8VHGWRLQGLFDWHWKH$LUÀRZ5DWH$LU 9ROXPH)DQ6SHHG$LUÀRZ'LUHFWLRQ screen. (Refer to page 12.) * $YDLODEOHIDQVSHHGDQGDLUÀRZGLUHFWLRQ YDU\ZLWKWKHFRQQHFWLQJPRGHO 3. Menu/Enter button Used to indicate the Main Menu. (Refer to page 23 for the menu items.) Used to enter the setting item selected. 7. Left button " " Used to highlight the next items on the left-hand side. Display contents are changed to previous screen per page. * %HVXUHWRSUHVVWKHSDUWZLWKWKHV\PERO " " 8. ON/OFF button 3UHVVWKLVEXWWRQDQGV\VWHPZLOOVWDUW 3UHVVWKLVEXWWRQDJDLQDQGV\VWHPZLOO stop. 9. Operation lamp (Green) This lamp lights up during operation. This lamp blinks if a malfunction occurs. 10.Cancel button 4. Up button " " Used to raise the set temperature. Use to highlight the item above the current selection. 7KHKLJKOLJKWHGLWHPVZLOOEHVFUROOHG FRQWLQXRXVO\ZKHQWKHEXWWRQLVNHSW pressed.) Used to change the item selected. * %HVXUHWRSUHVVWKHSDUWZLWKWKHV\PERO " " Used to return to the previous screen. 11.LCD (with backlight) 7KHEDFNOLJKWZLOOEHOLWIRUDSSUR[LPDWHO\ 30 seconds by pressing any operation EXWWRQ3UHVVWKHEXWWRQZKLOHWKHEDFNOLJKW is lit. (Excluding the ON/OFF button) If 2 remote controllers are used to control a VLQJOHLQGRRUXQLWWKHEDFNOLJKWRIWKH UHPRWHFRQWUROOHUDFFHVVHG¿UVWZLOOEHOLW 5. Down button " " 8VHGWRORZHUWKHVHWWHPSHUDWXUH 8VHWRKLJKOLJKWWKHLWHPEHORZWKHFXUUHQW selection. 7KHKLJKOLJKWHGLWHPVZLOOEHVFUROOHG FRQWLQXRXVO\ZKHQWKHEXWWRQLVNHSWSUHVVHG Used to change the item selected. * %HVXUHWRSUHVVWKHSDUWZLWKWKHV\PERO " " 6. Right button " " Used to highlight the next items on the right-hand side. Display contents are changed to next screen per page. * %HVXUHWRSUHVVWKHSDUWZLWKWKHV\PERO " " 6 Names and Functions Basic Screen %DVLFVFUHHQDUHWZRW\SHVRI6WDQGDUGGLVSOD\VFUHHQDQG'HWDLOHGGLVSOD\VFUHHQ The Standard display screen is set by default. 7RVZLWFKWRWKH'HWDLOHGGLVSOD\VHOHFWWKH'HWDLOHGLQWKH0DLQ0HQX(Refer to page 51.) 7KHFRQWHQWVRQWKHVFUHHQYDU\ZLWKWKHRSHUDWLRQPRGHRIWKHFRQQHFWLQJPRGHO 7KHIROORZLQJGLVSOD\ZLOODSSHDUZKHQWKHDLUFRQGLWLRQHULVLQ$XWRPDWLFRSHUDWLRQ Standard display screen 11.Changeover Under Control 10.Centralized Control 1.Operation mode 3.Airflow Direction uto isplayed only when the air conditioner is in operation. 2.Airflow Rate (Air Volume/Fan Speed) 7.Ventilation/Air purifying 12.Setback 9.Timer Enabled et to ool eat 8.Key Locked 4.Set/Setback Temperature display 5.Defrost/Hot start This function not available tandard display e ample 6.Message Detailed display screen The clock, and selectable display items appear on the detailed display screen in addition to the items appearing on the standard display screen. Auto Fri 11:03 Setback Room Cool 35°C Heat 10°C 20°C 13.Clock (12/24 hours time display) 4.Set/Setback Temperature display 14.Selectable Display tem <Detailed display example 1> 2.Airflow Rate (Air Volume/Fan Speed) is not appear ( o air low rate co trol u ctio ) 3.Airflow Direction is not appear ( o air low directio u ctio ) 7 (with room temperature selected) 13. Clock ( o cloc setti Auto : et to Cool 2 °C Heat 20°C ) 15. Timer Disabled/ Reset Clock 14. Selectable Display tem ( o selecta le display item selected) <Detailed display example 2> 1. Operation Mode 'LVSOD\VWKHSUHVHQWRSHUDWLRQPRGH &RRO+HDW9HQW)DQ'U\RU "Auto". 2. $LUÀRZ5DWH$LU9ROXPH)DQ Speed) 'LVSOD\VWKHDLUÀRZUDWHWKDWLVVHWIRUWKH indoor unit. 7KHDLUÀRZUDWHZLOOQRWEHGLVSOD\HGLIWKH LQGRRUXQLWGRHVQRWKDYHDLUÀRZUDWH control function. 3. $LUÀRZ'LUHFWLRQ " 'LVSOD\HGZKHQWKHDLUÀRZGLUHFWLRQDQG VZLQJDUHVHW(Refer to page 13). This icon is not displayed if the indoor unit GRHVQRWKDYHDIXQFWLRQWRVHWDLUÀRZ directions. 4. Set/Setback Temperature display :KHQWKHDLUFRQGLWLRQHULVWXUQHGRQ"Set to" indicates the set temperatures that are set for the air conditioner. :KHQWKHDLUFRQGLWLRQHULVWXUQHGRII "Setback" indicates the setback temperatures that are set for the air conditioner. 5. Defrost/Hot start " " (Refer to page 14.) Displays if the Defrost/Hot start operation is active. If ventilating operation " " is displayed: 'LVSOD\HGZKHQD+HDW5HFODLP9HQWLODWRU is connected. )RUGHWDLOVUHIHUWRWKH2SHUDWLRQ0DQXDO of the Heat Reclaim Ventilator. ,IDQXPEHURILQGRRUXQLWVDUHLQRSHUDWLRQ WKHPHVVDJHZLOODSSHDURQO\LIQRQHRIWKH LQGRRUXQLWVLVSURYLGHGZLWKWKH FRUUHVSRQGLQJIXQFWLRQLHWKHPHVVDJH ZLOOQRWDSSHDULIDWOHDVWRQHRIWKHLQGRRU XQLWVLVSURYLGHGZLWKWKHFRUUHVSRQGLQJ function. "Error: Push Menu button" "Warning: Push Menu button" 'LVSOD\HGLIDQHUURURUZDUQLQJLVGHWHFWHG (Refer to page 61). "Quick Start" (Split system only) Displayed if the quick cooling/heating function is turned on (Refer to page 30). 7LPHWRFOHDQ¿OWHU "Time to clean element" 7LPHWRFOHDQ¿OWHUDQGHOHPHQW 'LVSOD\HGZKHQWKHWLPHWRFOHDQWKH¿OWHU or element has come (Refer to page 59). 7. Ventilation/Air Purifying 'LVSOD\HGZKHQD+HDW5HFODLP9HQWLODWRU is connected. Ventilation Mode icon." " These icons indicate the current ventilation mode (Heat Reclaim Ventilator only) $8720$7,&(1(5*<5(&/$,0 9(17,/$7,21%<3$66 $LUSXULI\LQJLFRQ " This icon indicates that the Air Purifying unit (optional accessory) is in operation. 8. Key Locked " 'LVSOD\HGZKHQWKHNH\ORFNLVVHW 9. Timer Enabled " 6. Message The following messages are displayed. " (Refer to page 21.) " (Refer to page 40 and 47.) Displayed if the Schedule timer or OFF timer is enabled. "This function not available." 'LVSOD\HGIRUDIHZVHFRQGVZKHQDQ operation button is pressed and the indoor unit does not have the corresponding function. 8 10.Centralized Control " " Displayed if the system is under the management of centralized control equipment (optional accessories) and the operation of the system through the remote controller is prohibited. 11. Changeover Under Control " " (VRV only) Displayed if the remote controller has no cool/heat selection eligibility. (Refer to page 19). 12.Setback " " (Refer to page 17.) 7KHVHWEDFNLFRQEOLQNVZKHQWKHDLU conditioner is turned on under the setback control. 13.Clock (12/24 hours time display) 'LVSOD\HGZKHQWKHFORFNLVVHW(Refer to page 55). ,IWKHFORFNLVQRWVHWZLOOEH displayed. 14.Selectable Display Item 'LVSOD\HGZKHQWKHGHWDLOHGGLVSOD\LV selected (Refer to page 51). No detailed items are selected by default. 15.Timer Disabled/Reset Clock " 'LVSOD\HGZKHQWKHFORFNQHHGVWREH reset. 7KHVFKHGXOHWLPHUIXQFWLRQZLOOQRWZRUN unless the clock is reset. 9 " 10 Basic Operation (Use of Direct Buttons) How to follow the operation manual Operation procedure Explains a button operation procedure. Operation button Describes the positions of buttons to be pressed. Operation 1 Operation screen display Main Menu Setting Return Describes screens that ZLOOEHGLVSOD\HGRQWKH remote controller. 1/2 Quick Start Ventilation Energy Saving Options Schedule Filter Auto Clean Maintenance Information Schedule Clock has not been set. Would you like to set it now? Yes Return ate No Setting Time ear onth ay Tuesday Return etting Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Schedule . Press Menu/Enter button to display the Schedule screen. %HIRUHVHWWLQJWKHVFKHGXOHWKHFORFNPXVW be set. ,IWKHFORFNKDVQRWEHHQVHWDVFUHHQOLNH WKHRQHRQWKHOHIWZLOODSSHDU Press " " buttons to select Yes and press Menu/Enter button. 7KH'DWH7LPHVFUHHQZLOODSSHDU 6HWWKHFXUUHQW\HDUPRQWKGD\DQGWLPH (Refer to "Clock & Calendar" on page 55.) Cool/Heat/Auto/Fan Operation Preparation )RUPHFKDQLFDOSURWHFWLRQSXUSRVHVWXUQRQWKHSRZHUWRWKHDLUFRQGLWLRQHUDWOHDVWKRXUV before starting the operation. Operation 1 Cool Set to Cool 28°C Basic screen Press Mode Selector button several times until the GHVLUHGPRGH&RRO+HDW)DQRU$XWRLVVHOHFWHG. * Unavailable operation modes are not displayed. * Only the Cool or Fan mode can be selected if the air conditioner is a cooling only model. Note The cooling or heating mode cannot be selected if the icon " " (Changeover Under Control) is displayed on the remote " display blinks. controller. Refer to page 19 if the icon " 11 2 3 Press ON/OFF button. 7KH2SHUDWLRQODPSJUHHQZLOOEHOLWDQGWKH V\VWHPZLOOVWDUWRSHUDWLQJ Cool Set to Cool 28°C 7KHVHWWHPSHUDWXUHZLOOLQFUHDVHE\ &ZKHQ " button is pressed and decrease by &ZKHQ " button is pressed. * 1RWHPSHUDWXUHVHWWLQJVDUHSRVVLEOHZKLOHRSHUDWLQJLQ)DQ mode. 4 Cool Set to Cool 28°C 7RVHOHFW$LUYROXPHRU'LUHFWLRQVHWWLQJSUHVV " " buttons. Air volume/direction Air volume Low Return Return 5 Direction Position 0 Setting Low Medium Auto High A $LUÀRZ5DWH$LU9ROXPH)DQ6SHHGRU $LUÀRZ'LUHFWLRQ6HWWLQJ 3UHVV$LUÀRZVHWWLQJEXWWRQ $LUÀRZ5DWH$GMXVWPHQW! :LWK$LUYROXPHVHOHFWHGVHWWKHGHVLUHGDLUÀRZ rate from low Medium High or Auto using the " buttons. " * 'HSHQGLQJRQWKHW\SHRILQGRRUXQLWWKH DGMXVWPHQWOHYHOVPD\EHWZROHYHOVRI low and High or three levels of low MediumDQG High . * )RUHTXLSPHQWSURWHFWLRQSXUSRVHVWKHLQGRRU XQLWPD\FRQWURODLUÀRZUDWHDXWRPDWLFDOO\ * $FFRUGLQJWRWKHURRPWHPSHUDWXUHWKHLQGRRU XQLWPD\FRQWURODLUÀRZUDWHDXWRPDWLFDOO\ 7KHIDQPD\VWRSRSHUDWLQJZKLFKKRZHYHULV not a failure. * ,WPD\WDNHWLPHXQWLODFKDQJHRIWKHDLUÀRZUDWH is completed. * In Auto VHWWLQJWKHDLUÀRZUDWHLVDGMXVWHG automatically according to set temperature and URRPWHPSHUDWXUH,Q)DQPRGHWKHDLUÀRZUDWH VHWWLQJLVDOZD\VDW+LJK 12 Air volume/direction Air volume Low Return Return Direction Position 0 Setting Air volume/direction Air volume Low Return Return Direction Swing Setting $LUÀRZGLUHFWLRQ VHWWLQJXSGRZQ Air volume/direction Air volume Low Return Return Direction Swing Setting $LUÀRZGLUHFWLRQ setting (left/right) <$LUÀRZ'LUHFWLRQ6HWWLQJ! :LWK'LUHFWLRQVHOHFWHGVHWWKHGHVLUHGDLUÀRZ GLUHFWLRQIURP Position 0 Position 1 Position 2 Position 3 Position 4 Swing and Auto using the " " buttons. Note $LUÀRZGLUHFWLRQDSSHDUVRQWKHVFUHHQDVEHORZ 3RVLWLRQ 0 3RVLWLRQ 4 0 1 3RVLWLRQ 2 3 1 3 4 2 3RVLWLRQ 8SGRZQGLUHFWLRQ Left/right direction 3RVLWLRQ :KHQ\RXVHWRQHRISRVLWLRQVWRWKHDLUÀRZ GLUHFWLRQÀDSVWD\LQD¿[HGSRVLWLRQ Selecting Swing ZLOOFDXVHWKHDLUÀRZGLUHFWLRQ ÀDSWRVZLQJSRVLWLRQWR )RUWKHVZLQJVHWWLQJRQO\DOOSRVLWLRQVZLOOEHGLVSOD\HG Setting AutoZLOOYDULHGDLUÀRZGLUHFWLRQE\URRP temperature and the presence or absence of the person. +RZHYHULQ)DQPRGHWKHDLUÀRZGLUHFWLRQÀDS ZLOOEHWRSRVLWLRQ (This function may not be available depending on the type of indoor unit.) 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. 0RYHPHQWRIDLUÀRZGLUHFWLRQÀDSEODGH 8QGHUWKHRSHUDWLRQFRQGLWLRQVVKRZQEHORZDLUÀRZGLUHFWLRQLVFRQWUROOHGDXWRPDWLFDOO\$FWXDO RSHUDWLRQPD\WKXVEHGLIIHUHQWIURPZKDWLVGLVSOD\HGRQWKHUHPRWHFRQWUROOHU Operation condition 13 Room temperature is higher than the set temperature (in Heat/Auto mode). 'LVFKDUJHKRUL]RQWDOO\VRWKDWLWGRHVQRWGLVFKDUJHGLUHFWO\WRZDUG\RXUERG\ When the air conditioner goes into Heating Operation or Defrost Operation (in Heat/Auto mode). (Discharges horizontally to avoid a cold draft for the room occupants.) 8QGHUFRQWLQXRXVRSHUDWLRQZLWKWKHDLUÀRZGLVFKDUJHVKRUL]RQWDOO\LQ&RRO$XWRPRGH (Discharges in the automatic set direction for a period of time to prevent FRQGHQVDWLRQRQWKHKRUL]RQWDOÀDS 8QGHUFRQWLQXRXVRSHUDWLRQZLWKWKHDLUÀRZGLVFKDUJHVGRZQZDUGLQ&RRO$XWRPRGH (Discharges in the automatic set direction for a period of time to prevent FRQGHQVDWLRQRQWKHKRUL]RQWDOÀDS 6 :KHQWKH212))EXWWRQLVSUHVVHGDJDLQWKHDLU FRQGLWLRQHUZLOOVWRSRSHUDWLQJDQGWKH2SHUDWLRQ ODPSZLOOWXUQRII * :KHQWKHDLUFRQGLWLRQHULVVWRSSHGZKLOHLQWKH +HDWLQJ2SHUDWLRQWKHIDQZLOOFRQWLQXHWR operate for approximately 1 minute to remove residual heat from the indoor unit. Note 7RSUHYHQWZDWHUOHDNDJHRUV\VWHPIDLOXUHGRQRWWXUQRIIWKH SRZHULPPHGLDWHO\:DLWDWOHDVWPLQXWHVIRUWKHGUDLQSXPSWR ¿QLVKGUDLQLQJUHVLGXDOZDWHUIURPWKHLQGRRUXQLW Characteristic of Cooling Operation (in Cool/Auto mode) :KHQRSHUDWLQJFRQWLQXRXVO\DWKRUL]RQWDOO\RUGRZQZDUGDLUÀRZ GLUHFWLRQDLUEORZVLQWKHDXWRPDWLFDOO\VHWGLUHFWLRQIRUDSHULRGRI WLPHWRSUHYHQWFRQGHQVDWLRQRQWKHKRUL]RQWDOÀDS 7KHUHPRWHFRQWUROOHUGLVSOD\VWKHDLUÀRZGLUHFWLRQWKDWLVVHW ,IWKH&RROLQJ2SHUDWLRQLVXVHGZKHQWKHURRPWHPSHUDWXUHLVORZ frost forms on the heat exchanger of the indoor unit. 7KLVFDQGHFUHDVHWKHFRROLQJFDSDFLW\,QWKLVFDVHWKHDLUFRQGLWLRQHU DXWRPDWLFDOO\VZLWFKHVWRWKH'HIURVW2SHUDWLRQIRUDZKLOH 'XULQJWKH'HIURVW2SHUDWLRQWKHORZDLUÀRZUDWHRUDJHQWOHZLQGLV XVHGWRSUHYHQWWKHGLVFKDUJHRIPHOWZDWHU 7KHUHPRWHFRQWUROOHUGLVSOD\VWKHDLUÀRZUDWHWKDWLVVHW :KHQWKHRXWGRRUDLUWHPSHUDWXUHLVKLJKLWWDNHVVRPHWLPHXQWLOWKH room temperature reaches the set temperature. Characteristics of Heating Operation (in Heat/Auto mode) Starting Operation Heating Operation generally requires a longer time to reach the set WHPSHUDWXUHFRPSDUHGZLWK&RROLQJ2SHUDWLRQ It is recommended to start operating in advance by utilizing the timer. The air conditioner automatically controls the following operation to prevent the reduction of heating capacity and space comfort. Defrost Operation (Frost removal operation for the outdoor unit) 7KHDLUFRQGLWLRQHUZLOODXWRPDWLFDOO\JRLQWR'HIURVW2SHUDWLRQWRSUHYHQW frost accumulation at the outdoor unit and loss of heating capacity. 7KHLQGRRUXQLWIDQZLOOVWRSDQG 'HIURVW+RWVWDUWZLOOEH displayed on the remote controller. 7KHDLUFRQGLWLRQHUZLOOUHWXUQWRQRUPDORSHUDWLRQDIWHUDSSUR[LPDWHO\ to 8 minutes (Max 10 minutes). Hot start When the air conditioner goes into Heating Operation or Defrost 2SHUDWLRQWKHLQGRRUXQLWIDQZLOOVWRSLQRUGHUWRSUHYHQWDFROGGUDIW ,QWKDWFDVH 'HIURVW+RWVWDUWZLOOEHGLVSOD\HGRQWKH remote controller.) 14 Regarding outdoor air temperature and heating capacity 7KHKHDWLQJFDSDFLW\ZLOOGURSZLWKDGHFUHDVHLQRXWGRRUDLU temperature. ,IWKHKHDWLQJHIIHFWLVLQVXI¿FLHQWLWLVUHFRPPHQGHGWRXVHDQRWKHU KHDWLQJDSSOLDQFHLQFRPELQDWLRQZLWKWKHDLUFRQGLWLRQHU :KHQDFRPEXVWLRQDSSOLDQFHLVXVHGYHQWLODWHWKHURRPUHJXODUO\ 'RQRWXVHWKHFRPEXVWLRQDSSOLDQFHLQSODFHVZKHUHWKHFRPEXVWLRQ DSSOLDQFHLVH[SRVHGWRWKHZLQGIURPWKHDLUFRQGLWLRQHU 7KLVDLUFRQGLWLRQHULVDKRWDLUFLUFXODWLRQW\SHWRZDUPWKHZKROH URRP7KHUHIRUHLWWDNHVVRPHWLPHIRUWKHURRPWREHFRPHZDUP after the system starts operating. :KHQWKHURRPWHPSHUDWXUHH[FHHGVWKHVHWWHPSHUDWXUHWKHLQGRRU XQLWGLVFKDUJHVDJHQWOHEUHH]HVZLWFKHVWRJHQWOHZLQG7KHDLUÀRZ direction becomes horizontal. 7KHUHPRWHFRQWUROOHUGLVSOD\VWKHDLUÀRZUDWHDQGDLUÀRZGLUHFWLRQ that are set.) ,IWKHKRWDLUVWD\VDURXQGWKHFHLOLQJDQG\RXUIHHWIHHOFROGWKHXVHRI a circulator is recommended. )RUGHWDLOVFRQVXOW\RXUORFDOGHDOHU Dry Operation Preparation )RUPHFKDQLFDOSURWHFWLRQSXUSRVHVWXUQRQWKHSRZHUWRWKHDLUFRQGLWLRQHUDWOHDVWKRXUV before starting the operation. Dry mode may not be selected if the remote controller has no eligibility to select cooling/ heating mode (Refer to page 20 for details). Operation 1 Dry Press Mode Selector button several times until Dry mode is selected. * Dry mode may not be available depending on the type of indoor unit. 2 Press ON/OFF button. 7KH2SHUDWLRQODPSJUHHQZLOOEHOLWDQGWKHDLU FRQGLWLRQHUZLOOVWDUWRSHUDWLQJ * 7KHDLUFRQGLWLRQHUFRQWUROVWHPSHUDWXUHDQGDLUÀRZUDWH DXWRPDWLFDOO\7KHUHIRUHVHWWHPSHUDWXUHRUDLUÀRZUDWHVHWWLQJV DUHQRWDYDLODEOHZKLOHWKHDLUFRQGLWLRQHULVLQRSHUDWLRQ 15 3 7RVHWDLUÀRZGLUHFWLRQUHIHUWRSDJH 4 :KHQ212))EXWWRQLVSUHVVHGDJDLQWKHDLU FRQGLWLRQHUZLOOVWRSRSHUDWLQJDQGWKH2SHUDWLRQ ODPSZLOOEHWXUQHGRII Note 7RSUHYHQWZDWHUOHDNDJHRUV\VWHPIDLOXUHGRQRWWXUQRIIWKH SRZHULPPHGLDWHO\:DLWDWOHDVWPLQXWHVIRUWKHGUDLQSXPSWR ¿QLVKGUDLQLQJUHVLGXDOZDWHUIURPWKHLQGRRUXQLW 16 Characteristics of Dry Operation 'U\PRGHUHSHDWVWKHZHDNFRROLQJRSHUDWLRQLQWHUPLWWHQWO\WRGHKXPLGLI\WKHURRPZLWKRXWGURSSLQJ the room temperature as much as possible for the prevention of excessive cooling. Setback 7KH6HWEDFNIXQFWLRQZLOOPDLQWDLQWKHURRPWHPSHUDWXUHLQDVSHFL¿FUDQJHGXULQJXQRFFXSLHG periods. Note 7KLVIXQFWLRQZLOOWHPSRUDULO\VWDUWDQDLUFRQGLWLRQHUWKDWZDVSUHYLRXVO\WXUQHGRIIE\WKHXVHURU turned off from a schedule setting/off timer. This function is disabled by default. This function can be changed enable/disable by Main Menu. (Refer to page 34) )RUH[DPSOH 6HWEDFNWHPSHUDWXUHFRRO&+HDW& 5HFRYHU\'LIIHUHQWLDOFRRO &+HDW& ,IWKHURRPWHPSHUDWXUHGURSVEHORZ&WKHDLUFRQGLWLRQHUVWDUWVRSHUDWLQJLQ+HDWLQJ DXWRPDWLFDOO\$VVRRQDVLWUHDFKHV&WKHDLUFRQGLWLRQHUUHWXUQVWRLWVRULJLQDOVWDWXV ,IWKHURRPWHPSHUDWXUHJRHVDERYH&WKHDLUFRQGLWLRQHUVWDUWVRSHUDWLQJLQ&RROLQJ DXWRPDWLFDOO\$VVRRQDVLWUHDFKHV&WKHDLUFRQGLWLRQHUUHWXUQVWRLWVRULJLQDOVWDWXV The differential can be adjusted in the Setback condition menu (Refer to page 36). The setback temperature can be set on Basic screen during the air conditioner is turned off. Or the setback temprature can be set in the schedule (Refer to page 45). Operation 7KHVHWEDFNFDQQRWEHHQDEOHGZKHQDFHQWUDOL]HGFRQWUROHTXLSPHQWLVFRQQHFWHG 1 17 Cool et ac Cool 35°C The Setback icon " EOLQNVZKHQWKHDLU conditioner is turned on under the Setback control. Ventilation Operation When Air Conditioner Interlocked with Heat Reclaim Ventilator Preparation )RUHTXLSPHQWSURWHFWLRQSXUSRVHVWXUQRQWKHSRZHUWRWKHDLUFRQGLWLRQHUDWOHDVWKRXUV before starting the operation. Operation 1 Vent Press Mode Selector button several times until Vent mode is selected. * Vent mode is for single operation of Heat Reclaim 9HQWLODWRUIRUWKHVHDVRQZKHQFRROLQJKHDWLQJLV unnecessary. 2 The Ventilation mode can be changed from the Main Menu. (Refer to page 33). * 9HQWLODWLRQPRGH$XWR(QHUJ\5HFODLP9HQWLODWLRQDQG%\SDVV 3 The Ventilation rate can be changed from the Main Menu. (Refer to page 32). * 9HQWLODWLRQUDWH/RZRU+LJK 4 Press ON/OFF button. 7KH2SHUDWLRQODPSJUHHQZLOOEHOLWDQGWKH+HDW 5HFODLP9HQWLODWRUZLOOVWDUWRSHUDWLQJ 5 :KHQ212))EXWWRQLVSUHVVHGDJDLQWKH+HDW 5HFODLP9HQWLODWRUZLOOVWRSRSHUDWLQJDQGWKH 2SHUDWLRQODPSZLOOEHWXUQHGRII 18 Setting the Cool/Heat Selection Eligibility (VRV only) Setting Changes 1 Cool Return Cool Set to Cool 28°C Setting Refer to "Cool/Heat Selection Eligibility" on page 20 for an explanation of the cool/heat selection eglibility. Press Mode Selector button on the remote controller that has cool/heat selection eligibility for at least 4 seconds. (During backlight lit) $UHPRWHFRQWUROOHUZLOOQRWGLVSOD\ " " (Changeover Under Control) if a cool/heat selection eligibility is granted to the remote controller. The icon " " on each remote controller of indoor units FRQQHFWHGWRWKHVDPHRXWGRRUXQLWRU%6XQLWZLOOVWDUWEOLQNLQJ Set to Cool 28°C * Vent mode setting changes are possible regardless of the cool/ heat selection eligibility. * If a cool/heat selection eligibility is set in the "Cool/Heat selector" ( DOOWKHUHPRWHFRQWUROOHUVZLOOGLVSOD\WKHLFRQ " . In WKLVFDVHQRFRROKHDWVHOHFWLRQHOLJLELOLW\FDQEHVHWLQWKH remote controllers. Refer to the Operation Manual attached to the outdoor unit for the details of the "Cool/Heat selector". 6HWDFRROKHDWVHOHFWLRQHOLJLELOLW\DVIROORZV Selection Settings 2 Cool Cool 19 Set to Cool 28°C Set to Cool 28°C The icon " &KDQJHRYHU8QGHU&RQWUROZLOOEOLQNRQDOOUHPRWH FRQWUROOHUVZKHQWKHSRZHULVWXUQHGRQIRUWKH¿UVWWLPH Press Mode Selector button on the remote FRQWUROOHUIRUZKLFKWKHVHOHFWLRQHOLJLELOLW\WREH set. 7KHQWKHFRROKHDWVHOHFWLRQHOLJLELOLW\ZLOOEHVHW and the icon " ZLOOGLVDSSHDU ZLOODSSHDURQWKHRWKHUUHPRWH The icon " controllers. 3 Cool Set to Cool 28°C Press Mode Selector button on the remote controller that has the cool/heat selection HOLJLELOLW\WKHUHPRWHFRQWUROOHUZLWKRXWWKHLFRQ ") several times until the desired mode is " selected. 7KHGLVSOD\ZLOOFKDQJHWR)DQ'U\$XWR &RRO+HDWHDFKWLPHWKHEXWWRQLVSUHVVHG 7KHGLVSOD\$XWRZLOODSSHDUIRUWKH+HDW Recovery system only. 6LPXOWDQHRXVO\WKHRWKHUUHPRWHFRQWUROOHUVZLOO IROORZVXLWDQGFKDQJHWKHGLVSOD\DXWRPDWLFDOO\ Cool/Heat Selection Eligibility 7KH&RRO+HDW$XWRFDQEHVHWE\RQO\WKHUHPRWHFRQWUROOHUWKDWKDVWKHFRROKHDWVHOHFWLRQ eligibility. 7KHGLVSOD\$XWRZLOODSSHDUIRUWKH+HDW5HFRYHU\6\VWHPRQO\ 1. 7KHUHPRWHFRQWUROOHUZLWK the selection eligibility (Icon " " (Changeover Under Control) is not displayed) 6HWWR&RRO+HDW 'U\$XWRPRGH Other remote controllers (Icon " " (Changeover Under Control) is displayed) 7KHV\VWHPZLOOJRLQWRWKHPRGHVHWLQ WKHUHPRWHFRQWUROOHUZLWKWKHVHOHFWLRQ eligibility. Other modes are not available. +RZHYHUWKHV\VWHPFDQEHVZLWFKHG to “Fan” mode. ,QFDVHRI³&RRO´RU³'U\´PRGHWKH V\VWHPFDQEHVZLWFKHGWR³'U\´PRGH from “Cool” mode and to vice-versa. 2. 7KHUHPRWHFRQWUROOHUZLWK the selection eligibility (Icon " " (Changeover Under Control) is not displayed) Other remote controllers Set to "Fan" mode. (Icon " " (Changeover Under Control) is displayed) The system cannot be set to other modes except fan mode. 20 Precautions for Setting Cool/Heat Selection Eligibility 7KHFRROKHDWVHOHFWLRQHOLJLELOLW\QHHGVWREHVHWIRUDVLQJOHUHPRWHFRQWUROOHULQWKHIROORZLQJ case. (Heat Pump System) (Heat Recovery System) BS (Branch Selector) unit: The BS unit is used for cool or heat mode selection. Indoor unit Indoor unit A number of indoor units are connected to a single outdoor unit. A number of indoor units are connected to a single BS unit. Set the Cool/Heat/Fan mode selection eligibility in one of the remote controllers. Set the Cool/Heat/Auto/Fan mode selection eligibility in one of the remote controllers. Key Lock Operation Make settings and cancel settings in the Basic screen. 1 Cool Set to Cool 28°C Continue pressing Menu/Enter button for at least 4 seconds. (During backlight lit) Basic screen 2 21 Cool Set to Cool 28°C " ZLOODSSHDU $OOEXWWRQVDUHGLVDEOHGZKHQWKHNH\VDUHORFNHG 7RFDQFHOWKH.H\ORFNFRQWLQXHSUHVVLQJ Menu/Enter button for at least 4 seconds. (During backlight lit) 22 Quick Reference of Main Menu Main Menu Items Setting and display items Air Flow Direction Description Reference page Individual setting 8VHGWRVHWDQ$LUÀRZGLUHFWLRQIRUPD[LPXP ÀDSVLQGLYLGXDOO\ ,QFDVHRI6SULWV\VWHPPD[LPXPXQLWV XQLW$%&' ,QFDVHRI959PD[LPXPXQLWVXQLWWR 15) 28 Individual setting list Used to see the table for setting for maximum ÀDSV 29 Individual set all reset Used to clear all of the individual settings. 30 Used to set the room to a comfortable temperature quickly (unless the system is not in Dry or Fan operation). The maximum quick cooling/heating operation period is 30 minutes. 30 Ventilation Rate Used to set to Low or High 32 Ventilation Mode Used to set AutomaticEnergy Reclaim VentilationDQGBypass. 33 Energy Saving list Enable or Disable can be set up about the IROORZLQJPHQXV 34 Setpoint range set The set temperature range can be restricted. It is possible to restrict the temperature range based on a model and the mode of operation. 35 Set back condition 'HWHUPLQHWKHSRLQWZKHQDLUFRQGLWLRQHULV turned off again from the setback control. (recovery differential). 36 Sensing Sensor (low) (only if the sensing sensor is installed) 1RWH When no people are detected during a FRQWLQXRXVO\¿[HGWLPHWKHIXQFWLRQZLOO automatically change the air conditioning target temperature. ,ISHRSOHDUHGHWHFWHGLWZLOOUHWXUQWRWKH normal set temperature. 37 Sensing Sensor (stop) (only if the sensing sensor is installed) 1RWH When no people are detected during a FRQWLQXRXVO\¿[HGWLPHWKHIXQFWLRQZLOO automatically stop the air conditioner. 38 Setpoint Auto Reset (YHQLIWKHVHWWHPSHUDWXUHLVFKDQJHGLW returns to the preset temperature after SURJUHVVRIDGH¿QHGSHULRGRIWLPH 39 (only if the LQGLYLGXDODLUÀRZ function is installed) Quick Start (SPLIT system only) Ventilation Ventilation operation settings for Heat Reclaim Ventilator Energy Saving Options 23 Setting and display items Energy Saving Options Off Timer Description $IWHU\RXWXUQRQWKHDLUFRQGLWLRQHULWZLOO DXWRPDWLFDOO\WXUQRIILQDGH¿QHGSHULRGRI time. Reference page 40 Possible to set in 10 minutes increments from 30 to 180 minutes. Electricity consumption $QHOHFWULFLW\FRQVXPSWLRQXQWLOQRZLV displayed. This enables you to evaluate the trend of the electricity consumption. Note: This function availability is depending on type of indoor unit. Note: This function is not available in case more than 1 indoor unit are connected in group to the remote controller. Note: Displayed electricity consumption is not UHVXOWRIDN:KPHDVXUHPHQWEXWUHVXOWVIURP DFDOFXODWLRQZLWKUXQQLQJGDWDRIWKHDLU conditioner. Some factors in this calculation are absolute YDOXHVEXWRWKHUIDFWRUVPHUHO\UHVXOWIURP LQWHUSRODWLRQVZLWKWROHUDQFH7KLVH[SODLQV ZK\WKHUHDGRXWPD\GHYLDWHIURPWKHDFWXDO electricity consumption. 41 Enable/Disable Enable or Disable of a schedule function can be changed. 47 Schedule nr set The schedule number that must be active can EHVHOHFWHGVFKHGXOHQURU 43 Holidays Convenient holiday settings and temporary closure settings are possible. 44 Settings Set the startup time and operation stop time. 216WDUWXSWLPHFRROLQJDQGKHDWLQJ VHWWLQJWHPSHUDWXUHFDQEHFRQ¿JXUHG 2))2SHUDWLRQVWRSWLPHFRROLQJDQG heating setback setting temperature can be FRQ¿JXUHG ,QGLFDWHVWKDWWKHVHWEDFNIXQFWLRQLV disabled for this time period.) B,QGLFDWHVWKDWWKHVHWWLQJWHPSHUDWXUH and setback setting temperature for this WLPHSHULRGLVQRWVSHFL¿HG7KHODVWDFWLYH VHWWLQJWHPSHUDWXUHZLOOEHXWLOL]HG Up to 5 actions can be set for each day. 45 Filter Auto Clean This function is available only on the model ZKRVHSDQHOKDV¿OWHUDXWRFOHDQIXQFWLRQ For detailed operation refer to the operation manual of these models. 48 Maintenance Information Used to display the service contact and model information. 49 Schedule 24 Setting and display items Description Reference page &RQ¿JXUDWLRQ Draft prevention (only The draft prevention function can be enif the sensing sensor is installed) Display Used to set to standard or detailed display mode. Display Standard or detailed display Detailed display settings Selectable from the display room temperaWXUHRXWGRRUDLUWHPSHUDWXUHV\VWHPRU None. 51 Contrast Adjustment Used to make LCD contrast adjustment. 53 Used to display a list of current settings for available items. 54 8VHGWRFRQ¿JXUHGDWHDQGWLPHVHWWLQJV and corrections. 55 Current Settings Clock & Calendar 50 abled or disabled. Date & Time The default time display is 24H. 7KHFORFNZLOOPDLQWDLQDFFXUDF\WRZLWKLQ ±30 seconds per month. ,IWKHUHLVDSRZHUIDLOXUHIRUDSHULRGQRW H[FHHGLQJKRXUVWKHFORFNZLOOFRQWLQXH ZRUNLQJZLWKWKHEXLOWLQEDFNXSSRZHUVXSSO\ 12H/24H Clock Language The time can be displayed in either a 12 hour or 24 hour time format. 57 The displayed language can be selected from WKHIROORZLQJODQJXDJH(QJOLVK'HXWVFK Français/Italiano/Español/Português/ 1HGHUODQGV3\FFƸɢɣ(ȜȜȘȞȚțȐɌUNoH3ROVNL 58 1RWH$YDLODEOHVHWWLQJLWHPVYDU\ZLWKWKHPRGHOFRQQHFWHG Only the available setting items appear in the menu. 2. This function cannot be used at the time of group control. ,QFDVHRIWKHVLPXOWDQHRXVRSHUDWLRQV\VWHPWKHV\VWHPLVFRQWUROOHGE\WKHVHQVLQJ sensor mounted in the master indoor unit. Menu Items of Sub Remote Controller Indoor unit ,IUHPRWHFRQWUROOHUVDUHLQFRQWURORIDVLQJOHLQGRRUXQLW WKHIROORZLQJPHQXLWHPVDUHQRWVHWLQWKHVXEUHPRWH controller. Set them in the main remote controller. 25 $LU)ORZ'LUHFWLRQ Energy Saving Options Schedule Setback Filter Auto Clean Outdoor unit 2 remote controllers in control 26 Menu Manipulation Manipulating the Main Menu Screen Display Method for Main Menu Operation 1 Press Menu/Enter button. Cool Set to Cool 28°C Basic screen 2 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Retur etti Main Menu screen 3 7KH0DLQ0HQXVFUHHQZLOODSSHDU ,QVWUXFWLRQVIRUPDQLSXODWLQJWKHEXWWRQVZLOO appear. Select items from the Main Menu. 1. Press " " buttons to select the desired item to be set. 2. Press Menu/Enter button to display the selected settings screen. 4 To go back to the Basic screen from the Main 0HQXVFUHHQSUHVVWKH&DQFHOEXWWRQ Caution :KLOHVHWWLQJLWHPVLIDEXWWRQLVQRWSUHVVHGIRUPLQXWHVWKHVFUHHQZLOODXWRPDWLFDOO\JR back to the Basic screen. 27 ,QGLYLGXDO$LUÀRZ'LUHFWLRQ Individual Setting Operation 1 ai e u 12 Air Flow Directio uic tart Retur etti Display the Main Menu screen (Refer to page 27). Select Air Flow Direction in the Main Menu. 3UHVV0HQX(QWHUEXWWRQWRGLVSOD\WKH$LU)ORZ Direction settings screen. Main Menu screen 2 Individual setting Individual setting list Individual set all reset Return 3 Select Individual setting . Press Menu/Enter button. Air Flow Direction Setting Individual setting Outlet it A Direction No ind. set Outletmark Retur Return 4 etti Setting Individual setting Outlet UnitA Direction o i d set Outletmark Retur Return etti Setting Press " " buttons to select the unit and outlet mark. ,QFDVHRIIRXURXWOHWV\RXFDQFRQWUROHDFKRQHRI ÀDSVH[WKHIROORZLQJPDUNVDUHEHVLGHHDFKDLU outlet. ) individually. ,QFDVHRI63/,7V\VWHPPD[LPXPXQLWVXQLW $%&'FDQEHVHW ,QFDVHRI959V\VWHPPD[LPXPXQLWVIRU each group (unit 0 to 15) can be set. Press " EXWWRQWRVHOHFWDLUÀRZGLUHFWLRQVHWWLQJ Press " EXWWRQVWRFKDQJHWKHIROORZLQJ VHWWLQJV o ind. set Position 0 Position 1 Position 2 Position 3 Position 4 Swing blocked . o ind. set 1R,QGLYLGXDO6HWWLQJ blocked ,QGLYLGXDODLUÀRZLVEORFNHG 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. 28 5 Cool Set to Cool 28°C ,ILQGLYLGXDODLUÀRZGLUHFWLRQLVVHWWKH,QGLYLGXDO $LUÀRZ'LUHFWLRQLFRQ " is displayed in the Basic screen. Basic screen Individual Setting List Operation 1 Return 2 Setting di idual setti itA utletmar Retur 29 'LVSOD\WKH$LU)ORZ'LUHFWLRQVFUHHQ5HIHUWR page 28). Press " " buttons to select Individual setting list . Press Menu/Enter button. Air Flow Direction Individual setting Individual setting list Individual set all reset list Air direc di Auto Auto Auto Auto FF FF FF FF $WDEOHVKRZVWKHFXUUHQWVHWWLQJV Press " " buttons to go to the next unit. Press Cancel button to return to the Main Menu screen. Individual Set All Reset Operation 1 di idual setti di idual setti ist di idual set all reset Retur 2 'LVSOD\WKH$LU)ORZ'LUHFWLRQVFUHHQ5HIHUWR page 28). Press " " buttons to select Individual set all reset . Press Menu/Enter button. Air Flow Directio etti Press " " buttons to select Yes . Press Menu/Enter buttonWRFRQ¿UPWKHUHVHWDQG return to the Main Menu screen. Individual set all reset Clear individual air flow setting? Yes Return No Setting Quick Start (SPLIT system only) Quick Start On Operation 1 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Retur Cool etti Set to Cool 28°C :KLOHRSHUDWLQJLQ&RROLQJ+HDWLQJRU$XWRPRGH display the Main Menu screen (Refer to page 27). Press " " buttons to select Quick Start on the Main Menu screen. Press Menu/Enter button to return to the Basic screen. 4XLFN6WDUWZLOODSSHDURQWKH%DVLFVFUHHQ 4XLFN6WDUWLVQRZRQ Quick Start 30 Quick Start Off Operation 2 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Retur Cool etti Set to Cool 28°C While Quick Start is displayed on the Basic VFUHHQGLVSOD\WKH0DLQ0HQXVFUHHQ5HIHUWR page 27). Press " " buttons to select Quick Start . Press Menu/Enter button to return to the Basic screen. 4XLFN6WDUWZLOOQRORQJHUDSSHDURQWKH%DVLF screen. 4XLFN6WDUWLVQRZRII Quick Start Quick Start 7KHDLUÀRZUDWHRILQGRRUXQLWLVDXWRPDWLFDOO\FRQWUROOHGLQFUHDVLQJWKH capacity of the outdoor unit and quickly bringing the room to a comfortable temperature. $LUÀRZUDWHGLVSOD\GLVDSSHDUDQGDLUÀRZUDWHFDQQRORQJHUEHVZLWFKHG &DQQRWEHVHWZKHQLQIDQDQGGU\PRGHV 4XLFN6WDUWZLOORSHUDWHIRUDPD[LPXPRIPLQXWHVEHIRUHWKHDLUFRQGLWLRQHUDXWRPDWLFDOO\ returns to normal operation. $FWLYDWLQJPRGHVHOHFWRUZLOOUHWXUQWKHDLUFRQGLWLRQHUWRQRUPDORSHUDWLRQ ,QKHDWLQJPRGHDLUÀRZUDWHZLOOLQFUHDVHDQGWKHDLURXWOHWWHPSHUDWXUHPD\GHFUHDVH Adjust the operation as desired. 31 Ventilation Display Method for Ventilation Screen Operation 1 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Retur etti e tilatio 22 Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Ventilation . )RUPRGHOVZLWKQRYHQWLODWLRQIXQFWLRQ Ventilation ZLOOQRWEHGLVSOD\HG Press Menu/Enter button to display the Ventilation screen. e tilatio Rate e tilatio ode Retur etti Changing the Ventilation Rate Operation 1 e tilatio 22 e tilatio Rate e tilatio ode Retur 2 etti Display the Ventilation settings screen (Refer to above). Press " " buttons to select Ventilation Rate . Press Menu/Enter button to display the Ventilation rate screen. Press " or High . e tilatio e tilatio Rate " buttons to change the setting to Low Hi h * Only modes that can be set are displayed. Retur Low 3 Cool etti High Set to Cool 28°C Select the desired ventilation rate. Press Menu/ (QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJVDQGUHWXUQWR the Basic screen. (Press Cancel button to return to the previous VFUHHQZLWKRXWFKDQJLQJWKHYHQWLODWLRQUDWH 32 Changing the Ventilation Mode Operation 1 e tilatio 22 e tilatio Rate e tilatio ode Retur 2 etti e tilatio e tilatio 22 ode ypass Retur Display the ventilation screen. (Refer to page 32.) Press " " buttons to select Ventilation Mode . Press Menu/Enter button to display the Ventilation mode screen. Press " " buttons to change the settings in RUGHUDVVKRZQEHORZ ypass Energy Reclaim Vent. Auto etti * Only modes that can be set are displayed. 3 Cool Set to Cool 28°C Select the desired ventilation mode. Press Menu/ (QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJVDQGUHWXUQWR the Basic screen. (Press the Cancel button to return to the previous VFUHHQZLWKRXWFKDQJLQJWKHYHQWLODWLRQPRGH Ventilation Mode Automatic mode 8VLQJLQIRUPDWLRQIURPWKHDLUFRQGLWLRQHUFRROLQJKHDWLQJIDQ and set temperature) and the Heat Reclaim Ventilator unit (indoor DQGRXWGRRUDLUWHPSHUDWXUHVPRGHLVDXWRPDWLFDOO\FKDQJHG EHWZHHQ(QHUJ\UHFODLPYHQWLODWLRQDQG%\SDVV Energy reclaim ventilation mode 2XWGRRUDLULVVXSSOLHGWRWKHURRPZLWKXQGHUJRLQJKHDWH[FKDQJH Bypass mode 2XWGRRUDLULVVXSSOLHGWRWKHURRPZLWKRXWXQGHUJRLQJKHDW exchange. 33 Energy Saving Options Display Method for Energy Saving Options Screen Operation 1 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Retur er y etti a i ptio s Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Energy Saving Options . Press Menu/Enter button to display the Energy Saving Options screen. 12 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset Retur etti Energy Saving List Operation 1 er y a i ptio s Retur 2 er y etti a i list 22 etpoi t ra e set: et ac co ditio : e si e sor (low): e si e sor (stop): etpoi t Auto Reset: imer: Retur 3 12 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset er y etti a i list a e the setti s es Retur o FF FF FF FF FF FF Display the Energy Saving Options screen (Refer to above). Press " " buttons to select Energy Saving list . Press Menu/Enter button to display the Energy Saving List screen. Press " " buttons to change the setting to ON or OFF . ( ON (QDEOH OFF 'LVDEOH " buttons to move the cursor. Press " Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes on the FRQ¿UPDWLRQVFUHHQ 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. etti 34 Setpoint Range Setting Operation 1 er y a i ptio s Retur 2 etti etpoi t ra e set 22 Cool 20°C 32°C 1 °C 31°C Heat Retur 3 etti etpoi t ra e set a e the setti s es Retur 35 21 22 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset etti o Display the Energy Saving Options screen (Refer to page 34). Press “ ” buttons to select Setpoint range set . Press Menu/Enter button to display the Setpoint Range set screen. Press “ ” buttons to change the temperature setting range of cooling and heating. Press “ ” buttons to move the cursor. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. Setback Condition Operation 1 er y a i ptio s er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset Retur 2 etti Set back condition Recovery Differential Cool -2°C Heat +2°C Return 3 Setting et ac co ditio a e the setti s es Retur o 12 Display the Energy Saving Options screen (Refer to page 34). Press " " buttons to select Set back condition . Press Menu/Enter button to display the Set back condition screen. Press " " buttons to change the temperature differential of the Setback. Press " " buttons to move the cursor. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. etti 36 Sensing Sensor (low) This function cannot be used at the time of group control. ,QFDVHRIWKHVLPXOWDQHRXVRSHUDWLRQV\VWHPWKHV\VWHPLVFRQWUROOHGE\WKHVHQVLQJVHQVRU Operation mounted in the master indoor unit. 1 er y a i ptio s Retur 2 21 2 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset etti Sensing Sensor (low) Adjust temp. cool: 1.0°C Adjust time cool: 30 min Limit cool temp.: 30°C Adjust temp. heat: 1.0°C Adjust time heat: 60 min Limit heat temp.: 15°C Return Setting Display the Energy Saving Options screen (Refer to page 34). Press " " buttons to select Sensing Sensor (low) . Press Menu/Enter button to display the Sensing 6HQVRUORZVFUHHQ Press " " buttons to change the setting value RIVDYLQJHQHUJ\RSHUDWLRQZKHQWKHVHQVRU detects the absence. Press " " buttons to move the cursor. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU (Example) $GMXVWWHPSFRRO& $GMXVWWLPHFRRO PLQ /LPLWFRROWHPS & If it is determined that there is no person in the URRPE\VHQVRUGXULQJ&RROLQJ2SHUDWLRQWKHVHW WHPSHUDWXUHZLOODXWRPDWLFDOO\VKLIWE\&HYHU\ 30 minutes until the set temperature is 30°C. 2Q%DVLFVFUHHQVHWWHPSHUDWXUHGRHVQRW change.) 3 Sensing Sensor (low) Save the settings? Yes Return 37 No Setting Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. Sensing Sensor (stop) This function cannot be used at the time of group control. ,QFDVHRIWKHVLPXOWDQHRXVRSHUDWLRQV\VWHPWKHV\VWHPLVFRQWUROOHGE\WKHVHQVLQJVHQVRU Operation mounted in the master indoor unit. 1 er y a i ptio s Retur 2 e si etti e sor ( top) 22 A se t stop o o : FF A se t stop set time: 1 hours Retur 3 21 2 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset etti Sensing Sensor (stop) Save the settings? Yes Return No Display the Energy Saving Options screen (Refer to page 34). Press " " buttons to select Sensing Sensor (stop) . Press Menu/Enter button to display the Sensing Sensor (stop) screen. Press " " buttons to set the saving energy RSHUDWLRQZKHQWKHVHQVRUGHWHFWVWKHDEVHQFH Press " " buttons to move the cursor. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. Setting 38 Setpoint Auto Reset Operation 1 er y a i ptio s Retur 2 21 2 er y a i list etpoi t ra e set et ac co ditio e si e sor (low) e si e sor (stop) etpoi t Auto Reset etti Setpoint Auto Reset 2/2 Cool Set temp.: 28 °C Set time: 60 min Heat Set temp.: 20°C Set time: 90 min Return 3 Setting Setpoint Auto Reset Save the settings? Yes Return 39 No Setting Display the Energy Saving Options screen (Refer to page 34). Press " " buttons to select Setpoint Auto Reset . Press Menu/Enter button to display the Setpoint Auto Reset screen. Press " " buttons to set preset temperature and timing for the auto reset of the setpoint. Press " " buttons to move the cursor. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHVHWWLQJV and return to the Basic screen. Off Timer Operation 1 Energy Saving Options Off Timer Electricity consumption Return 2 Setting Off Timer After you turn on the unit, it will automatically turn off in 60 minutes. Return 3 Setting Off Timer Save the settings? Yes Return No 2/2 Display the Energy Saving Options screen. (Refer to page 34.) Press " " buttons to select the Off Timer . Press Menu/Enter button to display the Off Timer screen. Press " " buttons to set the time from operation start until the unit automatically stops. Selections can be made in increments of 10 minutes from 30 to 180 minutes. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. Select the desired time and press Menu/Enter button. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " button to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKH2II7LPHU settings and return to the Basic screen. Setting 40 Electricity Consumption Operation This item may not be available depend on the connecting model. 1 Energy Saving Options Setting Return 2 2/2 2/2 Off Timer Electricity consumption Electricity consumption Today 1 kWh 0 6 Total 10.5 kWh 12 18 24 Return Display the Energy Saving Options screen (Refer to page 34). Press " " buttons to select Electricity consumption . Press Menu/Enter button to display the Electricity consumption screen. Press " " buttons to move the indicating screen. 7RGD\!<HVWHUGD\!7KLVZHHNZHHN!/DVW ZHHNZHHN!7KLV\HDU\HDU!/DVW\HDU Change the items and values located in the upper right of the indication area using " " buttons. Electricity consumption This week 10 kWh Total 60.2 kWh S M T W T F S Return Electricity consumption This year 1 kWh 0 Return 41 3 6 Total 150 kWh 9 12 Press Cancel button to return to the previous screen. Schedule Display Method for Schedule Screen Operation 7KH6FKHGXOHFDQQRWEHHQDEOHGZKHQDFHQWUDOL]HGFRQWUROHTXLSPHQWLVFRQQHFWHG 1 ai e u 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea etti Retur Schedule Clock has not been set. Would you like to set it now? Yes Return ate No Setting Time ear onth ay Tuesday Return 2 %HIRUHVHWWLQJWKHVFKHGXOHWKHFORFNPXVWEHVHW ,IWKHFORFNKDVQRWEHHQVHWDVFUHHQOLNHWKHRQH RQWKHOHIWZLOODSSHDU Press " " buttons to select Yes and press Menu/Enter button. 7KH'DWH7LPHVFUHHQZLOODSSHDU 6HWWKHFXUUHQW\HDUPRQWKGD\DQGWLPH (Refer to "Clock & Calendar" on page 55.) etting Schedule Enable/Disable Schedule nr set Holidays Settings Return Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Schedule . Press Menu/Enter button to display the Schedule screen. Press " " buttons to select the desired item on the Schedule screen and press Menu/Enter button. Setting 42 Schedule Nr Set Operation This function can be stored in the schedule of 3 patterns. 1 Schedule Return 2 2/2 Enable/Disable Schedule nr set Holidays Settings Setting Press " Schedule Schedule nr set " buttons to select Schedule nr 1 Schedule nr 2 Schedule nr 1 Return Display the Schedule screen. (Refer to page 42.) Press " " buttons to select Schedule nr set . Press Menu/Enter button to display the Schedule nr set screen. Setting or Schedule nr 3 . Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU 3 Save the settings? Yes Return 43 Press " Schedule No Setting " buttons to select Yes . Press the Menu/EnterEXWWRQWRFRQ¿UPWKHGDLO\ patterns in the schedule and return to the Basic screen. Holidays 7KHVFKHGXOHWLPHUZLOOEHGLVDEOHGIRUGD\VWKDWKDYHEHHQVHWDVKROLGD\ Operation 1 Enable/Disable Schedule nr set Holidays Settings Return 2 Display the Schedule screen. (Refer to page 42.) Press " " buttons to select Holidays . Press Menu/Enter button to display the Holiday setting screen. Schedule Setting Schedule Holidays Multiple selection Sun Mon Tue Wed Thu Fri Sat Return 3 Setting Schedule Holidays Multiple selection Sun Mon Tue Wed Thu Fri Sat Return 4 Press " " button to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHKROLGD\ settings and return to the Basic screen. Save the settings? Yes Return No Setting chedule r 1 Hol ime Act :00 : : : : Retur 7RFRPSOHWHWKHKROLGD\VHWWLQJVSUHVV0HQX Enter button. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Setting Schedule at Press " " buttons to select the desired day. Press " " buttons to display " " to make the holiday settings. EXWWRQVWRVZLWFKWKHVHWWLQJEHWZHHQ Press " set and release. Multiple days can be selected as holidays. 1RWH7RHQDEOHWKHVFKHGXOHWLPHUIRUWKHGD\ VHOHFWHGDVDKROLGD\WKHKROLGD\VHWWLQJ must be released. Cool 2 °C Heat 20°C Note: +ROLGD\VWKDWDUHVHWZLOOEHGLVSOD\HGRQWKH Schedule screen. etti 44 Schedule Settings Operation 1 Schedule 2/2 Enable/Disable Schedule nr set Holidays Settings Return Setting Display the Schedule screen. (Refer to page 42.) Press " " buttons to select Settings . Press Menu/Enter button to display the Schedule screen. 127(7KH6FKHGXOH6HWWLQJVRIWKHVHOHFWHG schedule number can be changed. To change the schedule number refer to "Schedule Nr Set" on page 43. 2 o ime : : : : : Act Retur 3 Press " chedule r 1 Cool Heat Cool Heat Cool Heat Cool Heat Cool 2 °C Heat 21°C etti chedule r 1 o ime Act :00 : : : : Retur " EXWWRQVWRVHOHFWWKHGD\RIWKHZHHN to be set. etti Set the time for the selected day. Press " " buttons to move the highlighted item and press " " buttons to set the desired time. Each press of " " buttons moves the numbers by 1 hour or 1 minute. chedule r 1 o ime Act :00 : : : : Retur 4 etti chedule r 1 o ime Act :00 : : : : Retur etti chedule r 1 o ime Act :00 : : : : Retur 45 etti Press the " " buttons to move the highlighted item and press " EXWWRQVWRFRQ¿JXUH21 OFF/-- settings. 21RU2))FKDQJHVLQVHTXHQFHZKHQ " buttons are pressed. "Act" column: 21 7KHVHWWHPSHUDWXUHFDQEHFRQ¿JXUHG 2))7KHVHWEDFNWHPSHUDWXUHFDQEHFRQ¿JXUHG ±±7KHVHWWHPSHUDWXUHDQGVHWEDFN temperature become disabled. chedule r 1 ime Act :00 :00 FF : : : o Cool Heat 2 °C 21°C °C Retur 5 etti chedule r 1 ime Act :00 :00 FF 1 :30 2 2 :00 : o Retur Cool 2 °C 35°C 2 °C Heat 21°C 10°C 21°C Cool 2 °C 35°C 2 °C 35°C Heat 21°C 10°C 21°C 10°C Cool Heat Cool 2 °C 35°C 2 °C 35°C Heat 21°C 10°C 21°C 10°C etti The cooling and heating set temperature for both 21DQG2))6HWEDFNDUHFRQ¿JXUHG "Cool" and "Heat" column: "_ ,QGLFDWHVWKDWWKHVHWWHPSHUDWXUHDQG setback temperature for this time period is QRWVSHFL¿HG7KHODVWDFWLYHVHWWHPSHUDWXUH ZLOOEHXWLOL]HG "--,QGLFDWHVWKDWWKHVHWEDFNIXQFWLRQLV disabled for this time period. A maximum of 5 actions per day can be set. 3UHVVWKH0HQX(QWHUEXWWRQZKHQVHWWLQJVIRU HDFKGD\DUHFRPSOHWHG7KHFRQ¿UPDWLRQVFUHHQ ZLOODSSHDU chedule r 1 ime Act :00 :00 FF 1 :30 2 2 :00 FF : o Retur etti chedule r 1 ue ime : : : : : Act Retur etti Note: 7RFRS\WKHVHWWLQJVIRUWKHSUHYLRXVGD\SUHVVWKH Mode Selector button so that the existing settings ZLOOEHFRSLHG ([DPSOH7KHFRQWHQWVIRU0RQGD\DUHFRSLHGE\ pressing the Mode Selector button after selecting Tuesday. chedule r 1 ue ime Act :00 :00 FF 1 :30 2 2 :00 FF : Retur 6 etti Schedule Save the settings? Yes Return No Press " " buttons to select Yes . 3UHVVWKH0HQX(QWHUEXWWRQWRFRQ¿UPWKH settings for each day and return to the Main Menu screen. Setting 46 Enabling or disabling the schedule Operation 1 Schedule Return 2 2/2 Enable/Disable Schedule nr set Holidays Settings Setting Schedule Enable/Disable Disable Return Display the Schedule screen. (Refer to page 42.) Press " " buttons to select Enable/Disable . Press Menu/Enter button to display the Enable/ Disable screen. Press " " buttons to select Enable or Disable on the Enable/Disable screen. Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Setting 127(7KH6FKHGXOHQXPEHUVHOHFWHGLVHQDEOHG To change the schedule number see "Schedule Nr Set" on page 43. 3 Schedule Save the settings? Yes Return 47 No Setting Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHHQDEOH disable setting for the schedule and return to the Basic screen. Filter Auto Clean Operation 1 ai e u Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Filter Auto Clean and press Menu/Enter button. etti Retur 2 12 Air Flow Directio uic tart e tilatio er y a i ptio s chedule Filter Auto Clea Filter Auto Clean Filter Auto Clean 0:00 - 3:00 Return Setting Filter Auto Clean time zone setting can be set. 7KLVIXQFWLRQLVDYDLODEOHRQO\RQWKHPRGHOZKRVH panel has Filter Auto Clean function. )RUGHWDLOHGRSHUDWLRQUHIHUWRWKHRSHUDWLRQ manual of these models. 48 Maintenance Information Display Method for Maintenance Information Operation 1 ai e u 22 ai te a ce ormatio Co i uratio Curre t etti s Cloc Cale der a ua e Retur 2 etti ai te a ce Co tact 0123 5 door odel utdoor odel Retur ormatio o 0 000 000 Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Maintenance Information and press Menu/Enter button. The phone number for the contact is displayed at the top of the screen. ,ILWKDVQRW\HWUHJLVWHUHGE\LQVWDOOHULWZLOOQRW displayed.) The model name of the indoor and outdoor units of \RXUSURGXFWZLOOEHGLVSOD\HGRQWKHERWWRPRIWKH screen. (For some models the product code may be displayed instead of model name.) * 7KHPRGHOQDPHZLOOQRWGLVSOD\HGLIWKH3ULQWHG Circuit Board of the air conditioner has been replaced. * The Malfunction (Error) code history may also be displayed. ,ILWLVQRWEOLQNLQJWKHXQLWLVZRUNLQJSURSHUO\ The Malfunction (Error) code history is no longer displayed if you press ON/OFF button for more than 4 seconds. 49 &RQ¿JXUDWLRQ 'LVSOD\0HWKRGIRU&RQ¿JXUDWLRQ6FUHHQ Operation 1 ai e u 22 ai te a ce ormatio Co i uratio Curre t etti s Cloc Cale dar a ua e Retur etti Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select &RQ¿JXUDWLRQ . Press Menu/Enter button to display the &RQ¿JXUDWLRQVFUHHQ Draft prevention Operation 1 Draft prevention Display Contrast Adjustment Return 2 'LVSOD\WKH&RQ¿JXUDWLRQVFUHHQ5HIHUWRDERYH Press " " buttons to select Draft prevention . Press Menu/Enter button to display the Draft prevention screen. Configuration Setting Draft prevention Enable/Disable Disable Return 3 Setting Draft prevention Save the settings? Yes Return Press " " buttons to select Enable or Disable . Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU No Press " " buttons to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHHQDEOH disable setting for the draft prevention and return to the Basic screen. Setting 50 Display Display Mode Operation 1 Draft prevention Display Contrast Adjustment Return 2 Setting Display Display Mode Display Item Return 3 Standard None Press " " buttons to select Display Mode . Press Menu/Enter button to display the Display Mode screen. Setting Display Display Mode Standard Return 51 'LVSOD\WKH&RQ¿JXUDWLRQVFUHHQ5HIHUWRSDJH 50.) Press " " buttons to select Display . Press Menu/Enter button to display the Display screen. Configuration Setting Press " " buttons to select Standard or Detailed . 7KHQSUHVV0HQX(QWHUEXWWRQWRFRQ¿UPVHWWLQJV and return to the Basic screen. Setting the detailed display item selection Operation 1 Display Display Mode Display Item Return 2 Standard None Setting Press " Display Display Item None Return Display the Display screen. (Refer to page 51.) Press " " buttons to select Display Item . Press Menu/Enter button to display the Display Item screen. Setting EXWWRQVWRGLVSOD\WKHIROORZLQJ one System Outdoor Air Temp Room Temp * Some models may not display these items even if they are selected. %HVXUHWRUHDGWKHIROORZLQJQRWHVUHJDUGLQJGLVSOD\RIURRP temperature and outdoor air temperature. Room Temp .............. The temperature detected near the remote controller. The temperature may be affected by the location of the remote controller. Outdoor Air Temp .............. The temperature defected near the outdoor unit. The temperature may be affected by factors such as the location of the outdoor unit (in GLUHFWVXQOLJKWHJDQGXQLWRSHUDWLRQGXULQJ defrosting. $IWHUVHWWLQJSUHVV0HQX(QWHUEXWWRQWRFRQ¿UP settings and return to the Basic screen. 52 Contrast Adjustment Operation 1 Configuration Draft prevention Display Contrast Adjustment Return 2 Setting Contrast Adjustment Dark Light Return 53 Setting 'LVSOD\WKH&RQ¿JXUDWLRQVFUHHQ5HIHUWR page 50.) Press " " buttons to select Contrast Adjustment . Press Menu/Enter button to display the Contrast Adjustment screen. 2QWKH&RQWUDVW$GMXVWPHQWVFUHHQSUHVV " buttons until you reach the desired contrast. $IWHUVHWWLQJSUHVV0HQX(QWHUEXWWRQDQGUHWXUQ to the Basic screen. Current Settings Manipulating the Current Settings Operation 1 ai e u 22 ai te a ce ormatio Co i uratio Curre t etti s Cloc Cale dar a ua e Retur 2 Curre t Display the Main Menu screen. (See page 27.) Press " " buttons to select Current Settings and press Menu/Enter button. etti etti e tilatio Rate e tilatio ode chedule Display ode Display tem Filter Auto Clea s ow Auto Disa le ta dard utside 00 03 $OLVWRIWKHFXUUHQWVHWWLQJVWDWXVZLOODSSHDU Press " " buttons to go to the next item. Press Cancel button to return to the Main Menu screen. Retur Display items Ventilation Rate Ventilation Mode Schedule Quick Start Display Mode Display Item Filter Auto Clean * Display items may differ depending on the model. Only the items that can be set are displayed. 54 Clock & Calendar Display Method for Clock & Calendar Screen Operation 1 ai e u 22 ai te a ce ormatio Co i uratio Curre t etti s Cloc Cale dar a ua e Retur etti Display the Main Menu screen. (Refer to page 27.) Press " " buttons to select Clock & Calendar . Press Menu/Enter button to display the Clock & Calendar screen. Date & time Operation 1 Clock & Calendar Date & Time 12H/24H Clock Return 2 ate 6HOHFW<HDUZLWK " buttons. &KDQJHWKH\HDUZLWK " buttons. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. Time ear onth ay Tuesday Return 3 Setting Date etting 6HOHFW0RQWKZLWK " buttons. &KDQJHWKHPRQWKZLWK " buttons. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. ime ear 2013 o th 0 Day 01 o day 0:00 Retur 55 Display the Clock & Calendar screen. (Refer to above.) Press " " buttons to select Date & Time . Press Menu/Enter button to display the Date & Time screen. etti 4 Date ime ear 2013 o th 0 0 Day hursday 0:00 Retur 5 Date etti 6HOHFW+RXUZLWK " buttons. &KDQJHWKHKRXUZLWK " buttons. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. ime ear 2013 o th 0 Day 0 hursday 12:00 Retur 6 Date etti ime ear 2013 o th 0 Day 0 hursday 12:21 Retur 7 6HOHFW'D\ZLWK " buttons. &KDQJHWKHGD\ZLWK " buttons. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. 'D\VRIWKHZHHNFKDQJHDXWRPDWLFDOO\ etti Date & Time Save the settings? Yes Return No Setting 6HOHFW0LQXWHZLWK " buttons. &KDQJHWKHPLQXWHZLWK " buttons. +ROGLQJGRZQWKHEXWWRQFDXVHVWKHQXPEHUWR change continuously. Press Menu/Enter button. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " button to select Yes . 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPWKHFORFNDQG return to the Basic screen. * :KHQVHWWLQJWKHVFKHGXOHWKHGLVSOD\UHWXUQVWR the Schedule screen. 56 12H/24H Clock Operation 1 Clock & Calendar Date & Time 12H/24H Clock Return 2 Setting 12H/24H Clock 24H Return 3 Setting 12H/24H Clock Save the settings? Yes Return 57 No Setting Display the Clock & Calendar screen. (Refer to page 55.) Press " " buttons to select 12H/24H Clock . Press Menu/Enter button to display the 12H/24H Clock screen. %\GHIDXOWWKHWLPHGLVSOD\LVVHWWRWKH 24H format. Press " " buttons to select 12H or 24H . Press Menu/Enter button after selecting the item. 7KHFRQ¿UPDWLRQVFUHHQZLOODSSHDU Press " " buttons to select Yes . 3UHVVWKH0HQX(QWHUEXWWRQWRFRQ¿UPWKH+RU 24H and return to the Main Menu screen. Language Selectable Languages Operation 1 ai e u Retur 2 22 ai te a ce ormatio Co i uratio Curre t etti s Cloc Cale dar a ua e Press " " buttons to select Language and press the Menu/Enter button. etti Language English Return Display the Main Menu screen. (Refer to page 27.) Setting Press " " buttons to select the preferred ODQJXDJHIURPIROORZLQJ English/Deutsch/Français/Italiano/Español/ 3RUWXJXrV1HGHUODQGVS\FFƸɢɣ(ȜȜȘȞȚțȐɌUNoH Polski 3UHVV0HQX(QWHUEXWWRQWRFRQ¿UPVHWWLQJVDQG return to the Basic screen. 58 Maintenance Reset Filter Indicator Operation 1 :KHQWKHWLPHWRFOHDQWKH¿OWHURUHOHPHQWKDVFRPHRQHRIWKH Cool Retur ime to clea et to Cool 2 °C ilter IROORZLQJPHVVDJHVZLOODSSHDURQWKHERWWRPRIWKH%DVLFVFUHHQ 7LPHWRFOHDQ¿OWHU 7LPHWRFOHDQ¿OWHUHOHPHQW "Time to clean element" :DVKFOHDQRUUHSODFHWKH¿OWHURUHOHPHQW )RUGHWDLOVUHIHUWRWKHRSHUDWLRQPDQXDODWWDFKHG to the indoor unit. 2 3 5HVHWWKH¿OWHULQGLFDWRUZKHQWKH¿OWHURUHOHPHQW LVZDVKHGFOHDQHGRUUHSODFHG Press Menu/Enter button. 7KH0DLQ0HQXVFUHHQZLOODSSHDU ai e u 12 Reset Filter dicator Air Flow Directio uic tart e tilatio er y a i ptio s chedule Retur Cool Press " " buttons to select Reset Filter Indicator and press Menu/Enter button. etti Set to Cool 28°C 7KHPHVVDJHVKRZQLQ6WHS1ZLOOGLVDSSHDUIURP the Basic screen. 59 Caution Do not wash the remote controller. Doing so may cause electric leakage and result in electric shocks RUD¿UH Be sure to stop the operation of the air conditioner and turn off the power at the time of maintenance. Failure to do so may result in electric shocks or injury. Cleaning of Remote Controller :LSHWKHVXUIDFHSDUWRIWKHUHPRWHFRQWUROOHUZLWKDGU\FORWKZKHQLWEHFRPHGLUW\ ,IWKHGLUWRQWKHVXUIDFHFDQQRWEHUHPRYHGVRDNWKHFORWKLQQHXWUDOGHWHUJHQWGLOXWHGZLWK ZDWHUVTXHH]HWKHFORWKWLJKWO\DQGFOHDQWKHVXUIDFH:LSHWKHVXUIDFHZLWKDGU\FORWKWKHQ Note 'RQRWXVHDQ\SDLQWWKLQQHURUJDQLFVROYHQWRUVWURQJDFLG Warning 'RQRWXVHÀDPPDEOHPDWHULDOVHJKDLUVSUD\RULQVHFWLFLGHQHDUWKHDLU conditioner. Do not clean remote controller with organic solvents such as benzine or paint thinner. 7KHXVHRIRUJDQLFVROYHQWVPD\FDXVHFUDFNGDPDJHWRWKHSURGXFWHOHFWULFVKRFNV RUD¿UH 60 Reference Information Malfunction (Error) code Display Contact Your Dealer in the Following Cases Warning When the air conditioner is malfunctioning (e.g., giving off a burning odor), stop the air conditioner and turn off the power. &RQWLQXHGRSHUDWLRQXQGHUVXFKFLUFXPVWDQFHVPD\UHVXOWLQIDLOXUHHOHFWULFVKRFNVRUD¿UH Contact your local dealer. Operation 1 Cool Set to Cool 28°C Return Setting Error: Push Menu button ,IDPDOIXQFWLRQRFFXUVHLWKHURQHRIWKHIROORZLQJ PHVVDJHVZLOODSSHDURQWKH%DVLFVFUHHQGXULQJ operation. (UURU3XVK0HQXEXWWRQ * 7KH2SHUDWLRQODPSZLOOEOLQN :DUQLQJ3XVK0HQXEXWWRQ * 7KH2SHUDWLRQODPSZLOOQRWEOLQN Press Menu/Enter button. 2 Error code:A1 Contact Info 0123–4567–8900 Indoor unit Outdoor unit Return 61 –––/000 –––/000 The Error code blinks and the contact address and PRGHOQDPHZLOODSSHDU Notify your local dealer of the Error code and Model name. Operation lamp After-sales Service Warning Do not disassemble, modify, or repair the remote controller. ,WPD\FDXVHHOHFWULFVKRFNVRUD¿UH Consult your local dealer. Do not relocate or reinstall the remote controller by yourself. Improper installation may cause electric VKRFNVRUD¿UH Consult your local dealer. Advise the Repairer of the Following Items Model name Date of installation )DLOXUHFRQGLWLRQV$VSUHFLVHDVSRVVLEOH <RXUDGGUHVVQDPHDQGWHOHSKRQHQXPEHU Relocation The relocation of the remote controller requires special technology. Consult your local dealer. $FWXDOH[SHQVHVUHTXLUHGIRUWKHUHORFDWLRQRIWKHUHPRWHFRQWUROOHUZLOOEHFKDUJHG Inquiry about After-sales Service Contact your local dealer. 62 3P243520-4F EM12A039 (1303) AK