Download Sunny Boy, Sunny Mini Central
Transcript
SMA Technologie AG Operating modes of the inverter 4.4.8 Insulation fault or defective varistor The red LED on the Sunny Boy / Sunny Mini Central is continuously on. With this blink code, it is not relevant if the green or yellow LEDs shine or blink. A grounding fault exists or one of the thermally monitored varistors on the DC input is defective as a result of overvoltage or ageing. In this event, only devices with transformers (without "TL" in the device name) continue to feed electricity. (green) not relevant (red) The red LED is continuously on. (yellow) not relevant Consult trained electrical personnel to correct the fault. Fault removal instructions can be found in the inverter's installation manual. 4.4.9 Defective DC input Sunny Boy Multi-String The red LED blinks. With this blink code, it is not relevant if the green or yellow LEDs are on of off. At least one of the DC inputs is defective. (green) (red) not relevant The red LED blinks. (yellow) not relevant A fault has occurred which can no longer be resolved on-site. Consult SMA (see chapter 10 "Contact" (Page 67)) to discuss further action. Page 24 SB_SMC-BEN073618 Operating Instructions