6 - START UP 6.5 - Start up open the gas cock; power to the boiler; if the display shows E 21, it means that the phase/neutral polarity has not been observed; Exchange them; at start up, the display shows a F for 2 minutes during which the system is bleeded. If you want to bypass this phase, just press the + and buttons together until the F begins to flash. Then press the RESET button; rotate knobs "8" and "9" shown in figure 1 to the desired temperature; the heating service starts only when the room thermostat calls for heating. If the external temperature sensor is connected, check that the calculated temperature is greater than the minimum heating temperature (see figure 32); if the pump operation indicator (see section 7.16) is on and the pump (see figure 1 detail “44” is not running, it is necessary to unlock it; if the pump warning light (see section 7.16) is on and the radiators do not heat up, repeat air bleeding operations on both the boiler and the radiators. 6.5.1 - Self drainage 6.6 - Checking the gas supply pressure and adjusting it if necessary The gas supply pressure must match that given in the table in chapter 9 at the end of this manual. To check it, proceed as follows: close the gas cock; access the boiler internal components by following the procedure in section 8.3; loosen the pressure connection “D” (see figure 26); connect a pressure gauge with a definition of at least 0.1 mbar (1 mmH2O); open the gas cock; check that the pressure does not exceed the value given in the table in chapter 6 under the heading “Maximum gas supply pressure”; turn on the boiler and generate a request for heating (rotate knob “9” shown in figure 1 to the maximum) and make sure the room thermostat is in heating call status; Every time the appliance is powered, press buttons and a 2 minute self drainage procedure is together for more than 10 seconds started to bleed air from the system. The is displayed; until procedure starts and stops the pump to better remove air. press button until you display . Now the boiler is forced to maximum power for 10 minutes; Repeat the procedure for the “SLAVE” thermal element; check that the pressure does not drop below the “Minimum gas supply pressure" indicated in the table in chapter 9 at the end of the manual. If the supply pressure does not fall within the above values, operate upstream of the appliance to bring the pressure back within the maximum and minimum range. Once checked, close the pressure connection "D" (see figure 26) and verify whether there is any gas leakage. C- Service pressure connection D- Supply gas pressure inlet E - CO2 adjusting screws Maximum power F - CO2 adjusting screws to maximum power Figure 26 - Gas valve 31