Download pdf
Transcript
7 - USE 1 - Parameter display. 2 - Display of values adopted by parameters. 3 - Burner status indicator. On = burner on, flashing = burner off. 4 - Domestic water service status indicator. On = domestic water active, Off = domestic water inactive. 5 - Decimal indicator of the displayed value 6 - Heating service status indicator. On = heating active, Off = heating inactive 7 - Start and heating temperature knob. 8 - Button to decrease parameter values. 9 - Button to reset shutdowns and to scroll the parameter list. 10 - Button to increase parameter values. 11 - Domestic hot water temperature and start knob. 12 - Main switch. Figure 31 - Control panel 7.2 - Overview According to the architecture with which it is prepared, the thermal module command and control operations can be performed as follows: - by using the MASTER boiler control panel (see section 7.5 and 7.6); - by using the remote control (see section 7.4) - by using an external thermoregulator via 0-10Vdc analog signal (see section 5.14.7). In all above cases, during normal operation, the MASTER boiler display reads: - “c” followed by the supply temperature (probe U2), when in heating mode; -“d” followed by the water heater temperature (probe U3) when in domestic water mode (water heater loading). In normal operating conditions, the SLAVE thermal element always displays a "c" followed by the boiler temperature (probe U1). The thermal element is preset to standard parameters. It is however possible to change or look at the parameters via the "User menu" (see section 7.14). While functioning, the display "1" shown in figure 31 shows the status of the thermal element, whereas display "2" (see figure 31) shows the parameter value. The different operating statuses are indicated in the table in section 7.14. Within the "User menu" (see section 7.14) it is possible to check the latest locks or errors occurred. In addition to the operating modes, the instrument panel provides important information on the current functioning of the boiler, via the indicators “3”, “4”, “5” and “6” shown in figure 38. In particular: - the indicator “3” displays whether the burner is running (on) or off (flashing); - the indicator “4” displays whether the domestic water service is active or inactive; - the indicator “6” displays whether the thermal element pump is running (on) or nor (off). 36 7.3 - Precautions against freezing If you leave the house and turn the power and gas supplies off, the appliance will not be protected against freezing. Thus, in case of turning off with temperatures that may possibly drop below zero, you should empty the system. Contact a qualified technician. CAUTION!!! It is absolutely forbidden to introduce chemical additives, such as antifreeze or others, into the domestic water circuit.