Download Communication/CompoWay/F
Transcript
Appendix − Move to advanced function setting level 0C20 Sensor induction noise reduction Common 0010 − 0C1E PV decimal point display 000F Common CH CH CH CH CH CH CH CH Common Common 0C1C Remote SP lower limit 0C0C Input 4 type 0C0E Input 4 temperature units 0006 0007 Common Common Common Common 000E 0C08 Input 3 type 0C0A Input 3 temperature units 0004 0005 Scaling input value 1 Scaling display value 1 Scaling input value 2 Scaling display value 2 Decimal point position Remote SP upper limit 0C04 Input 2 type 0C06 Input 2 temperature units 0002 0003 Common 0C10 0C12 0C14 0C16 0C18 0C1A 0C02 Input 1 temperature units 0001 Common Setting (monitor) value amo snc p dp rspl inp.1 dsp.1 inp.2 dsp.2 dp rsph i4-t i4du i3-t i3du i2-t i2du i1du H'00000001:Pt100 (1) H'00000002:K (2) H'00000003:K (3) H'00000004:J (4) H'00000005:J (5) H'00000006:T (6) H'00000007:E (7) H'00000008:L (8) H'00000009:U (9) H'0000000A:N (10) H'0000000B:R (11) H'0000000C:S (12) H'0000000D:B (13) H'0000000E:W (14) H'0000000F:4 to 20 mA (15) H'00000010:0 to 20 mA (16) H'00000011:1 to 5 V (17) H'00000012:0 to 5 V (18) H'00000013:0 to 10 V (19) H'00000000: °C (0) H'00000001: F (1) Input 1: Same as input type H'00000000:°C (0) H'00000001: F (1) Input 1: Same as input type H'00000000: °C (0) H'00000001: F (1) Input 1: Same as input type H'00000000: °C (0) H'00000001: F (1) Input lower-limit to input upper-limit H'FFFFB1E1 (-19999) to scalling display value 2-1 Input lower-limit to input upper-limit Scaling display value 1+1 to H'0000270F (99999) H'00000000 to H'00000004 (0 to 4) Temperature: Lower limit of sensor setting range to upper limit of sensor setting range Analog: Larger of -19999 and "display value equivalent to input lower limit" to smaller of 99999 and "display value equivalent to upper input limit" Temperature: Sensor setting range to upper limit of sensor setting range Analog: Larger of -19999 and "display value equivalent to input lower limit" to smaller of 99999 and "display value equivalent to input upper limit" H'00000000: OFF (0) H'00000001: ON (1) H'00000000:50 Hz (0) H'00000001:60 Hz (1) H'FFFFF831 to H'0000270F (-1999 to 9999) 2 *4 °C 2 *4 °C 0 to 19 c, f 0 to 19 c, f -1999 to 9999 0 50 Hz ON off, on 50hz, 60hz -200 Same as at left Same as at left 0 to 4 4 *3 0 20 *3 100 0 1300 2 *4 °C 0 to 19 c, f Same as at left Same as at left Same as at left Same as at left °C 2 *4 Default value c, f 0 to 19 Character − − − − − − − − − − − − − − EU According to input type *2 EU *2 EU − EU − − − − 0 − 0 − − According to input type − − − − Units Decimal point position "H' -" indicated in set values (monitor values) are values set by communication (monitor). i1-t H'00000000:Pt100 (0) Attributes Character 0008 0009 000A 000B 000C 000D 0C00 Input 1 type 0000 Setting data *1 .... Input type settings are 0 to 14 for temperature input and 15 to 19 for analog input as determined by the input type switch (under the unit). *2 .... Determined by input type setting. *3 .... Initializes to upper-and lower-limits of input when the input type is changed. *4 .... The default value for the input type is "2" regardless of the setting of the input type switch. CC CompoWay/F Modbus Variable type Address Address Input initial setting level Set value Setting list A-17