PCSAU0773D
AIR CONDITIONING SYSTEM
HEAT PUMP [50Hz]
360° airflow!!
HFC R-410A Line Up
for Stores and Offices.
CEILING MOUNTED
CASSETTE TYPE
CEILING SUSPENDED TYPE
WALL MOUNTED TYPE
OUTDOOR UNIT
PRODUCT RANGE
Series
50
60
71
100
125
140
CEILING MOUNTED
CASSETTE TYPE
Page 5
Round Flow
Indoor unit
FCQ50KVEA
FCQ60KVEA
FCQ71KVEA
Outdoor unit
RZQ50KBV4A
RZQ60KBV4A
RZQ71KCV4A
FCQ100KVEA
RZQ100KCV4A
RZQ100HAY4A
FCQ125KVEA
RZQ125KCV4A
FCQ140KVEA
RZQ125HAY4A
RZQ140KCV4A
RZQ140HAY4A
NEW
CEILING SUSPENDED TYPE
Page 9
Indoor unit
FHQ71BVV1B
Outdoor unit
RZQ71KCV4A
NEW
WALL MOUNTED TYPE
FHQ100BVV1B
RZQ100KCV4A
RZQ100HAY4A
FHQ125BVV1B
RZQ125KCV4A
FHQ140CAVEA
RZQ125HAY4A
RZQ140KCV4A
RZQ140HAY4A
NEW
Page 11
Controllers
Page 15-16
Specifications
Page 20-21
Options
Page 22-23
Dimensions
Page 24-28
Indoor unit
FAQ71CVEA
Outdoor unit
RZQ71KCV4A
RZQ100HAY4A
Page 13
RZQ50KBV4A
RZQ60KBV4A
O U T D O O R
1
FAQ100CVEA
RZQ100KCV4A
RZQ71KCV4A
U N I T
RZQ100KCV4A
RZQ100HAY4A
RZQ125KCV4A
RZQ125HAY4A
O U T D O O R
RZQ140KCV4A
RZQ140HAY4A
U N I T
2
HFC R-410A Line Up
for Stores and Offices.
CEILING MOUNTED
CASSETTE TYPE
CEILING SUSPENDED TYPE
WALL MOUNTED TYPE
OUTDOOR UNIT
PRODUCT RANGE
Series
50
60
71
100
125
140
CEILING MOUNTED
CASSETTE TYPE
Page 5
Round Flow
Indoor unit
FCQ50KVEA
FCQ60KVEA
FCQ71KVEA
Outdoor unit
RZQ50KBV4A
RZQ60KBV4A
RZQ71KCV4A
FCQ100KVEA
RZQ100KCV4A
RZQ100HAY4A
FCQ125KVEA
RZQ125KCV4A
FCQ140KVEA
RZQ125HAY4A
RZQ140KCV4A
RZQ140HAY4A
NEW
CEILING SUSPENDED TYPE
Page 9
Indoor unit
FHQ71BVV1B
Outdoor unit
RZQ71KCV4A
NEW
WALL MOUNTED TYPE
FHQ100BVV1B
RZQ100KCV4A
RZQ100HAY4A
FHQ125BVV1B
RZQ125KCV4A
FHQ140CAVEA
RZQ125HAY4A
RZQ140KCV4A
RZQ140HAY4A
NEW
Page 11
Controllers
Page 15-16
Specifications
Page 20-21
Options
Page 22-23
Dimensions
Page 24-28
Indoor unit
FAQ71CVEA
Outdoor unit
RZQ71KCV4A
RZQ100HAY4A
Page 13
RZQ50KBV4A
RZQ60KBV4A
O U T D O O R
1
FAQ100CVEA
RZQ100KCV4A
RZQ71KCV4A
U N I T
RZQ100KCV4A
RZQ100HAY4A
RZQ125KCV4A
RZQ125HAY4A
O U T D O O R
RZQ140KCV4A
RZQ140HAY4A
U N I T
2
Features and Benefits of DAIKIN's
Round Flow cassette
Comfortable airflow
360˚ airflow with improved temperature distribution.
4-way flow type
4-way flow leaves areas
that cannot be covered.
Round Flow type
360° airflow realises uniform
airflow distribution.
Comfortable
Inverter performs variable control of frequency,
which determines air conditioner’s power performance.
At startup, full power is used to achieve the set temperature quickly.
Then, the capacity is adjusted according to the outdoor temperature
changes and subtle indoor load changes to achieve fine capacity control
resulting in a more stable room temperature.
Non-inverter
Running
current
Cooling operation
Temp
Inverter
Starting
current
Time
Current
Non-inverter type air
conditioners must be
switched on and off
repeatedly, causing
large fluctuations of the
room temperature.
Soft starter is
unnecessary, making
electrical installation
work much simpler.
Current
Enhanced comfort with Inverter
Running
current
Set temp
Small temp.
difference
Cools a room
in less time
Time
Inverter power control
Non-inverter type air conditioner
Time
At startup, inverter raises frequency
smoothly, eliminating the starting
current spike.
Compact
Compact and
lightweight
50 / 60KB, 71KC 100 / 125 / 140KC 100 / 125 / 140HA
Height(mm)
1,170
Width(mm)
900
Depth(mm)
320
Weight (kg)
3
770
68
98
1,345
1,170
mm
108
RZQ100KC-140KC
SkyAir Range
"Nav Ease"
Wired Remote Controller
Clear Display
NEW
Simple operation
Dot matrix display
Large buttons and
arrow keys
Backlight display
Guide on display
Energy saving
Convenience
NEW
Setpoint range set
Weekly schedule
NEW
Setpoint auto reset
Multilingual display
Off timer (programmed)
Wired Remote Controller
BRC1E62
Energy Efficient
Complies with MEPS
COP
What is COP
3.70
3.40
3.66
3.11
COP is equal to capacity (kW) divided
by power consumption (kW), and the
larger the COP value, the higher the
energy efficiency, enabling cooling and
heating with less electricity and
increasing
the
energy
saving
performance.
3.33
3.00
Heating
Cooling
1
2
2
Heating
Cooling
1
2
Heating
Cooling
1
2
Heating
1
Cooling
Heating
2
Cooling
1
2
3
(Coefficient of Performance)
1
2
3.57
3.81
Heating
4.02
3.84
1
4.26
3.94
Cooling
4
FCQ50KVEA
FCQ60KVEA
FCQ71KVEA
FCQ100KVEA
FCQ125KVEA
FCQ140KVEA
RZQ50KBV4A
RZQ60KBV4A
RZQ71KCV4A
RZQ100KCV4A
RZQ125KCV4A
RZQ140KCV4A
Note :
1
Rated cooling capacities are based on the
following conditions: Indoor temp., 27°CDB,
19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB.
Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the
following conditions: Indoor temp., 20°CDB,
outdoor temp., 7°CDB, 6°CWB. Equiv.
refrigeration piping, 7.5 m (horizontal)
Quiet operation
Night quiet operation function
The Automatic night quiet mode
will initiate 8 hours after the peak
temperature is reached in the
daytime, and normal operation will
resume 10 hours after that.
Reducing noise will reduce capacity slightly.
3
Sound level (dB(A))
Rated4
Night Quiet Mode
RZQ50/60KB
48
RZQ71KC
48
44
RZQ100KC/100HA
49
45
RZQ125KC/125HA
50
45
RZQ140KC/140HA
50
46
Note : 3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
4
Value when cooling. Value will differ when heating.
4
• • • • • •
5
*1
Hot start (after defrost)
Two selectable
temperature-sensors
High ceiling application
Programme "Dry"
Draft prevention function
(heating)
Switchable fan speed
(2 step)
Swing pattern selection
Auto swing
• •
*1 Applicable when wired remote controller is used
*2 For the outdoor units
Setpoint auto reset
Setpoint range set
Weekly schedule timer
Off timer (programmed)
*2
*1
*1
*1
*1
• • •
*2
Filter sign
• •
*2
Emergency operation
Low gas pressure
detection
Ceiling soiling prevention
• • • • • • • • • • • •
Anti corrosion treated
heat exchangers
Fresh air intake kit
Control features
High-efficiency filter
DIII-NET communication
standard
Interlock control
Central remote control
Work & Servicing
Auto-cooling/heating
change-over
Control by 2 remote
controllers
Group control by 1 remote
controller
External command
control
Auto-restart
Self-diagnosis function
Cleanliness
Pre charged for
up to 30 m
Drain pump mechanism
Remote controller
Silver ion anti-bacterial
drain pan
Comfort
Anti-bacterial air filter
Night quiet operation
Year-round cooling
applicable
CEILING MOUNTED CASSETTE TYPE
Round Flow
Uniform 360° airflow cassette air conditioner
is setting tomorrow's standards.
Heat pump
FCQ50K/60K/71K/100K/125K/140K
Accessory required for indoor unit
Wired LCD remote controller
"Nav Ease"
Note: Remote controller cable not
included. Cables must be
procured locally.
BRC1E62
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
BRC7F632F
Signal receiver unit
(Installed type)
Wireless remote controller and signal
receiver unit are sold as a set.
Features
Options Others
*2
Avoids uneven temperature and discomfort caused by drafts.
Comfort enhanced by Round Flow!
360 airflow
Air movement is gentle
with Round Flow
With uniform temperature
distribution
Enhanced Comfort
Airflow
distribution
creates uniform
comfort throughout
the space
360 airflow can
maintain comfort
even if air
discharge speed
is lower.
If you raise the set
temperature by 1 to
1.5°C in cooling (and
lower in heating),
and velocity is decreased
by 25%, you still obtain
the same feeling
temperature and comfort.
Greater comfort
Adapts easily to the installation space.
As air flows out from corner outlets, comfort spreads more evenly.
Typical flow patterns
There are a total of 23 flow patterns.
All-round flow
3-way flow
L-shaped
2-way flow
(E.g., installed in
middle of ceiling)
(E.g., installed
near a wall)
(E.g., installed in
a corner)
Opposite
2-way flow
(E.g., installed in
a long room)
4-way flow also possible.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to
close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.
Grime prevention and bactericidal coating: Makes cleaning easier.
External panels are treated with a coating that helps to
Treated
Untreated
repel dirt.
surface
surface
To help prevent dirt sticking to
the external panels, they have
been coated with a surface
treatment.
Resists
soiling
Grimy
surface
• Condition after exposure
to the smoke of 600
cigarettes in 1 m3
enclosed space.
Silver ion anti-bacterial
drain pan
Non-flocking flaps
Filter has anti-mould and
bactericidal treatment
Mould-proof drain pan includes a silver ion
antibacterial agent that assists in
preventing the growth of slime, bacteria,
and mould that cause smells and clogging.
Condensation does not easily form on
and dirt does not cling to non-flocking
flaps.
It is easy to clean.
Helps prevents mould and
microorganisms growing out of the dust
and moisture
that adheres to the filters.
6
CEILING MOUNTED CASSETTE TYPE
Unified square panels
Compact body and quiet operation
dB(A)
Panel size is the same for all models, FCQ50-140K.
It is easy to maintain a neat appearance when multiple
units are installed in the same room.
950
mm
Indoor unit
High
Low
50K
35
35
35
43
44
44
28
28
28
32
34
36
60K
95
0m
71K
Same for
all models
m
100K
125K
140K
Optimal comfort and convenience
assured by air discharge modes
Note: Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.
Air direction
Desired
situation
Auto-swing
5-levels
air direction
setting
Standard setting
Setting to prevent soiling of ceiling*
Standard setting to
prevent draft.
Recommended for shops with
light coloured ceilings that
must be kept spotless.
Auto-swing between
15° and 60°
Auto-swing between
25° and 60°
Settable to 5 different
levels between 15° and 60°
Settable to 5 different
levels between 25° and 60°
Draft prevention
(In heating mode)
At heating startup and thermo OFF, air discharge is
automatically set to a near horizontal 25˚ or 30˚ to
prevent direct exposure to cool air drafts.
Auto air
direction control
The air direction is set automatically to the
memorised position of the previous air direction.
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During operation
these values are somewhat
higher owing to ambient
conditions.
Quick and easy to install
Just 256 mm high. Installable in tight
ceiling spaces (50K–71K)
256 mm *1
266 mm *2
*1 298 mm high with 100K–140K
*2 308 mm high with 100K–140K
Easy height adjustment
Each corner of the unit has an Adjuster Pocket that
lets you easily adjust the unit's suspended height.
Note: If the wireless remote control option is installed, a light receptor
unit is housed in one of the adjuster pockets.
All models can be installed without
using lifter because of the light weight.
Can be installed in
any direction
*Closing of the corner discharge outlets is recommended.
Suitable for high ceilings
Even in spaces with high ceilings, a comfortable airflow is carried down to
the floor level.
Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value)
Number of air discharge outlets used
Standard
Ceiling
High ceiling
height
High ceiling
Round Flow
50K–71K
100K–140K
All round 4-way 3-way 2-way
flow
flow
flow
flow
All round 4-way 3-way 2-way
flow
flow
flow
flow
2.7 m 3.1 m 3.0 m 3.5 m
3.0 m 3.4 m 3.3 m 3.8 m
3.5 m 4.0 m 3.5 m -
3.2 m 3.4 m 3.6 m 4.2 m
3.6 m 3.9 m 4.0 m 4.2 m
4.2 m 4.5 m 4.2 m -
Since the orientation of
the intake grill can be
adjusted after installing,
the direction of the intake
grill lines can be unified
when multiple units
are installed.
Drain pump is equipped as standard
accessory with 850 mm lift.
Note: Factory settings are for standard ceiling height and all-round flow.
High ceiling settings (1) and (2) are set with the remote controller by field setting.
850 mm
Two selectable temperature-sensors
Both indoor unit and wired remote controller (option (BRC1E62) ) contain
temperature- sensors. Temperature sensing can be set at the unit or, to
further improve comfort level, closer to the target area at the wired remote
control. This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room.
**Wireless remote controller does not have a temperature-sensor.
Hot start (after defrost)
Switchable fan speed: High/Low
175 mm
Transparent drain
socket
Connection to a centralised control
system is available, no need for option
card.
Low gas pressure detection
7
Easier to maintain
The condition of the drain pan and
drain water can be checked by
removing the drain plug and
intake grille.
he
en t e!
p
o
Just ke grill
inta
Drain plug
Options required for specific operating environments
High-efficiency filter
Panel spacer
Available in two types: 65% and 90% colorimetry.
Use when only minimal space is available between drop
ceilings and ceiling slabs.
Fresh air intake kit
Using this kit, a
duct can be fitted to
increase the intake
of outdoor air.
Outside
40mm
Panel spacer
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other
parts should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary.
Optional PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced
through the kit is limited to 10% of the maximum airflow rate of the
indoor unit. Introducing higher quantities will increase the operating
sound and may also influence temperature sending.
Note: Some ceiling constructions may hinder installation.
Contact your Daikin Dealer before installing your unit.
Sealing material of air discharge outlet
Sealing material block air discharge openings not used in 2-way or
3-way blow.
Branch duct (direct-connection round duct)
A round duct can be attached without the need for a chamber.
A flanged port for direct connection of a round duct is
provided. An existing branch duct chamber can also be fitted
(square slit hole).
The units can be installed in the following different ways.
Chamber type
(without T-joint pipe and fan)
Chamber type
(with T-joint pipe and without fan)
KDDP55B160
KDDP55B160K
Flexible duct
(procured locally)
Flexible duct
T-joint pipe
(procured locally)
T-joint pipe
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Suction
chamber
Intake duct
Connection (procured locally)
chamber
(duct length: 4 m max.)
Direct installation type
KDDP55X160
Duct flange
(with insulation
material)
Intake duct
(procured locally)
Note: Use of options will increase operating sound.
8
CEILING SUSPENDED TYPE
Comfortable airflow travels
throughout the room
Heat pump
FHQ71BV / 100BV / 125BV / 140CA
FHQ71BV
NEW FHQ140CA
Accessory required for indoor unit
Wired Remote Controller
"Nav Ease"
BRC1E62
Note: Remote controller cable
not included. Cables must
be procured locally.
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
71/100/125BV
140CA
BRC7EA63W
BRC7GA53
71/100/125BV
140CA
Signal receiver unit (Installed type)
Wireless remote controller and signal
receiver unit are sold as a set.
Features
9
Anti corrosion treated
heat exchangers
• • • • • • • • •
Fresh air intake kit
Interlock control
Central remote control
External command
control
Options Others
DIII-NET communication
standard
*4
Group control by 1 remote
controller
•
Control by 2 remote
controllers
*4
Auto-cooling/heating
change-over
*5
Auto-restart
•
Control features
Self-diagnosis function
*3
Emergency operation
*3
Low gas pressure
detection
Off timer (programmed)
*3
Filter sign
Weekly schedule timer
*3
Pre charged for
up to 30 m
Setpoint range set
*4
* FHQ71-125BV: 2 step, FHQ140CA: 3 step
*2Installable on max. 3.5 m (71-125BV), 4.3 m (140CA) high ceiling
*3Applicable when wired remote controller is used
*4For the outdoor units
*5Option
*6FHQ140CA only
1
Work & Servicing
Drain pump mechanism
Setpoint auto reset
• •
Night quiet operation
*3
Year-round cooling
applicable
*2
Hot start (after defrost)
Two selectable
temperature-sensors
•
High ceiling application
*1
Programme "Dry"
Switchable fan speed
Draft prevention function
(heating)
Auto swing
• •
Anti-bacterial air filter
Remote controller Cleanliness
Comfort
*6
*6
*4
New 140 model
provides greater
capacity for large
spaces
The technology of the DC fan motor,
wide sirocco fan, and large heat
exchanger combine for greater
airflow and quiet operation.
High/Middle/Low : 46/42/38 db(A)
Sophisticated design
Flap neatly closes when not in use.
Fresh white colour.
Installable on
ceilings 4.3 m high
Quiet operation
dB(A)
Indoor unit
High
Middle
Low
71BV
39
42
44
46
------42
35
37
39
38
100BV
125BV
140CA
Uses quiet stream fan and other
quiet technologies.
(FHQ71-125BV)
Turbulent flow
is reduced
The unit fits more snugly
into tight spaces.
30mm
30mm
or more
or more
*Water used in the test-run can now be drained from the
air discharge opening rather than from the side as was
formerly the case.
Drain pump kit (option) can
be easily incorporated
Drain pump kit (option) includes a
silver ion antibacterial agent that
assists in preventing the growth of
slime, bacteria, and mould that
cause smells and clogging.
Drain pipe connection can be done inside
the unit. refrigerant and drain pipe outlets
are at the same opening.
600
mm
Drain pump kit
(built inside
main unit)
All wiring and internal servicing can be done
from under the unit
Simplified piping installation
Easy maintenance
Louver manually
adjusts for straight
or wide angle airflow
Long-life filter lasts up to 6 months*
Installable on ceilings 3.5 m high (FHQ71-125BV)
Non-flocking flap
Two selectable temperature-sensors
Condensation does not easily form on and
dirt does not cling to non-flocking flap.
Non-flocking flap
It is easy to clean.
Both indoor unit and wired remote controller (option (BRC1E62) ) contain
temperature- sensors. Temperature sensing can be set at the unit or, to
further improve comfort level, closer to the target area at the wired
remote control. This feature requires initial setting by the installer.
*Temperature-sensor on indoor unit must be used when the air conditioner is controlled from
another room.
**Wireless remote controller does not have a temperature-sensor.
Switchable fan speed: High/Low (FHQ71-125BV)
Programme "Dry"
Dehumidification is microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature.
Quiet stream fan
Flexible installation
Connection to a centralised control system
is available, no need for option card.
Auto swing (up and down) and louvers (left
and right by hand) bring comfort to the room
Straightening plate
Installation flexibility for
freedom of design
3 fan speeds: High/Middle/Low
Comfortable
Note : Anechoic chamber
conversion value, measured
according to JIS parameters
and criteria. During operation
these values are somewhat
higher owing to ambient
conditions.
* For dust concentration of 0.15 mg/m3
Two time settings (2500 hrs and 1250 hrs) are available to match the installation
environment. Maintenance time warning is displayed on the remote controller (filter
sign).
Easy-clean, flat surfaces
Oil resistant grille
Oil-resistant plastic is used for the air suction grille. This satisfies
durability in restaurants and other similar environments.
Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification
is not suitable for kitchens or other harsh environments.
10
• • •
11
*1
High fan speed mode
Auto airflow rate
Switchable fan speed
(3 step)
Draft prevention function
(heating)
Auto swing
• •
*1
Hot start (after defrost)
Two selectable
temperature-sensors
Programme "Dry"
• •
*1Applicable when wired remote controller is used
*2For the outdoor units
*3Option
Setpoint auto reset
Setpoint range set
Weekly schedule timer
Off timer (programmed)
*2
*1
*1
*1
*1
•
*3
*2
•
*2
• • • • • • • • • •
Control features
Anti corrosion treated
heat exchangers
DIII-NET communication
standard
Interlock control
Central remote control
External command
control
Group control by 1 remote
controller
Work & Servicing
Control by 2 remote
controllers
Auto-cooling/heating
change-over
Auto-restart
Self-diagnosis function
NEW
Emergency operation
Low gas pressure
detection
Cleanliness
Filter sign
Pre charged for
up to 30 m
Remote controller
Drain pump mechanism
Comfort
Mould-proof air filter
Night quiet operation
Year-round cooling
applicable
WALL MOUNTED TYPE
Compact design and
easy installation
FA Q 71/100C
FAQ71C
FAQ100C
Accessory required for indoor unit
Wired LCD remote controller
"Nav Ease"
Note: Remote controller cable not included.
Cables must be procured locally.
BRC1E62
Option
Wireless LCD remote controller
A signal receiver must be added to the indoor unit.
BRC7EB518
Wireless remote controller and signal
receiver unit are sold as a set.
Signal receiver unit (Installed type)
Features
Others
*2
Easy installing and
servicing
Compact &
Sophisticated design
FAQ100
9kg lighter
340
mm
1,200mm
370mm shorter
FAQ100BV FAQ100C
Height
360mm
340mm
Width
1,570mm
1,200mm
Depth
200mm
240mm
Weight
26kg
17kg
6-direction piping offers
greater installation
flexibility.
Left pipe
Back-left pipe
Bottom-left pipe
Right pipe
Back-right pipe
Bottom-right pipe
Maintenance possible from the front
of the unit
Flaps close fully
when not in use
All maintenance tasks can be carried out via front
access. During service work, attachment and
detachment of parts is easier.
Drain pump kit is available as option.
Installs onto side of unit.
Comfortable
Auto swing
(up and down) and
wide-angle louvers
(left and right by
hand) facilitate
even room
temperature
Air discharge
modes ensure
comfortable air
distribution across
the entire room
Height of drain up
Refrigerant
piping
1,000 mm
Wide-angle
louvers
(adjusted
manually)
Drain pump kit
Drain pump kit can be installed
on either left and right side of
the air conditioner.
Soft material
louver bends
airflow over a
wider area
Auto-swing
Indoor unit
5-level
air direction setting
Gettable to 5
different levels
Comfort even on the far side of the room
Connection to a centralised control
system is available, no need for option
card.
Easy cleaning
Removable and washable grille
To carry air to the far side of long
rooms, extra-high airflow adds 10%
more fan speed the "high" setting.
Air discharge setting is selected from
the remote controller by field setting.
Flat panel, easy to wipe dust off
Two selectable temperature-sensors
Non-flocking flaps
Switchable fan speed: High/Middle/Low
Condensation does not easily form on and dirt does not
cling to non-flocking flaps.
It is easy to clean.
Auto airflow rate (When BRC1E62 is used)
Programme "Dry"
Dehumidification is microprocessor controlled to prevent abrupt and
uncomfortable changes in air temperature.
12
OUTDOOR UNIT
Complies with
Complies
with
MEPS
MEPS
RZQ50KBV4A
RZQ60KBV4A
RZQ71KCV4A
RZQ100KCV4A
RZQ125KCV4A
RZQ140KCV4A
RZQ100HAY4A
RZQ125HAY4A
RZQ140HAY4A
Easy installation and maintenance
Operation range
Pre charged for up to 30 metres
4-direction piping offers greater
layout freedom
Suited for year-round cooling
applications
The outer panel for the piping connection
part of the front, right side and backside can
be removed and is easier for
post-installation
piping work.
Cooling is efficient even in winter when
indoor temperatures are higher than those
outside, such as in underground public
spaces or offices with many computers.
If the refrigerant piping length does not
exceed 30 m, there is no need for on-site
gas charging.
75 m piping length
(Applicable to RZQ100KC–140KC and
RZQ100HA–140HA outdoor units)
Wide operation range
50
50/60KB
Pre
charged1
Max.
length
100-125KC
100-125HA
71KC
30 m
50 m
30 m
(Equivalent
length 70m)
Max. level
difference
40
Separation
available
Allowed refrigerant piping length
and level difference
75 m
(Equivalent
length 90m)
30 m
Facilitates pump down
Note : Additional refrigerant charging is required if the
refrigerant pipe is longer than the length.
Cooling
15.5˚C
-5˚C
0
WB
Heating
DB
-15˚C
-10
-20
WB
Outdoor temp(˚CDB)
Outdoor temp(˚CWB)
*Pump-down function is available for pre-charged
refrigerant amount.
Effective gas monitoring reduces the labor
required for operation, maintenance, and
repairs.
Compact and light weight
Easy centralised installation
with the module oriented design
DB
20
10
(Refrigerant recovery function)
A pump-down switch is provided to make it
easier to collect refrigerant if the unit is to
be moved or layout modified.
Low gas pressure detection function
1
46˚C
30
Height(mm)
Width(mm)
Depth(mm)
Weight(kg)
Durability
As the bottom frame is subject to corrosion,
a corrosion-proof galvarium steel plate is
adopted to enhance the durability.
Heat exchange fins are provided with
anti-corrosion treatment
50/60KB, 71KC 100/125/140KC 100/125/140HA
770
1,170
1,345
900
320
68
98
108
Construction
Non-treated fin
Aluminium
Anti corrosion
treated heat
exchangers
Hydrophilic film
Aluminium
Corrosion resistant
acrylic resin
Night time quiet operation function
The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in
the daytime, and normal operation will resume 10 hours after that.
Reducing noise will reduce capacity slightly.
RZQ71KC
48
44
RZQ100KC/100HA
49
45
RZQ125KC/125HA
50
45
RZQ140KC/140HA
50
46
Note : 1Anechoic chamber conversion value, measured according
to JIS parameters and criteria. During operation these
values are somewhat higher owing to ambient conditions.
2
Value when cooling. Value will differ when heating.
100
8 hours
50
0
50
Limitation
Rated
45 Quiet mode
8:00
12:00 16:00 20:00
Note : 3In case of RZQ125
13
10 hours
Power
consumption
44
Capacity (%)
Night Quiet Mode
48
Load (%)
Operation
Sound (dB(A))
Rated2
RZQ50/60KB
The maximum capacity is maintained within
a set level of power consumption, which
makes it possible to keep a comfortable
and effective demand control.
Peak in outdoor temperature
1
Sound level (dB(A))
Demand Control
Quiet mode
8:00
0:00
4:00
8:00
12:00
16:00
* Required for KRP58M51 (Option)
20:00Time
Technology for energy efficiency
The high efficiency compressor
to achieve a high COP
1
Compressor equiped with Reluctance DC motor
Motor efficiency (%)
Daikin DC Inverter models are equipped with the Reluctance DC
motor for compressor.
The Reluctance DC motor uses 2 different types of torque,
neodymium magnet*1 and reluctance torque*2.
This motor can save energy because it generates more power
with a smaller electric power than an AC or conventional DC motor.
3
2
Reluctance DC Motor
90
1
Reluctance
DC motor
80
Conventional
DC motor
More than 20%
70
AC motor
60
50
0
30
60
90
120
Rotational speed (rps)
Small load
Low capacity
Large load
High capacity
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory.
>> Smooth sine
wave DC inverter
*1. A neodymium magnet is approximately 10 times stronger
than a standard ferrite magnet.
*2. The torque created by the change in power between the iron
and magnet parts.
Use of an optimised sine
wave smoothes motor
rotation, further improving
operating efficiency.
RZQ50/60KB, RZQ71KC
RZQ100/125/140KC, RZQ100/125/140HA
>> Swing compressor
Energy savings is
realised, eliminating
the friction and the
leakage of
refrigerant gas.
2
Sine wave DC inverter
Swing bushing
Refrigerant gas
Piston by incorporated
blade and roller.
Suction
>> The structural scroll
Sucked gas is compressed in
the scrolling part before the
heated motor, so that the
Discharge
machine compress the
non-expanded gas, resulting in
high efficiency compression.
Smooth Air Inlet Bell Mouth and Aero Spiral Fan
With the bent
blade edge
Scroll section
Motor section
Without the bent
blade edge
These two features work to reduce noise. Guides
are added to the bell mouth intake to reduce
turbulence in the airflow generated by fan suction.
The Aero Spiral Fan features fan blades with the
bent blade edges, further reducing turbulence.
Escaping eddies are sucked in by
the bent blade edges, reducing
overall turbulence.
3
DC fan motor
DC fan motor structure
Efficiency improved in all areas compared to AC
motors, especially at low speeds.
14
LCD REMOTE CONTROLLER
Easy-to-read LCD remote controller allows various system
Remote controller options are shown on the page introducing each indoor unit model.
Wired Remote Controller
NEW
"Nav Ease"
This simple, contemporary remote controller with
fresh white colour matches your interior design.
The clear, backlight display with large
easy-to-read text makes navigation easy and
provides one-touch control over your in-home
comfort.
BRC1E62
Clear Display
Dot matrix display
Backlight
display
A combination of fine dots
enables various icons.
Large text display is easy to
see.
Energy saving
Auto operation mode
NEW
Until now only the temperature for one point could be
set, but now the new remote controller (BRC1E62)
allows the setting of both Cooling and Heating, and with
the fan operation, mid-range temperatures are
comfortable andoperation is more energy efficient.
Setpoint auto reset
- Even if the set temperature is changed, it returns to
the preset temperature after a preset period of time.
- Period selectable from
30min/60min/90min/120min.
Restaurant sample
Restaurant opened
NEW
27°C
Temperature is set to 27ºC
2 setpoints
Cooling / Heating
Full tables at lunchtime
20ºC
Heating
operation
NEW
- Saves energy by limiting the min.
and max. set temperature.
- Avoids excessive
heating or cooling.
- This function is convenient when
the remote controller is installed
at a place where any number of
people may operate it.
15
26ºC
Fan operation
Setpoint range set
Then is lowered to 24ºC
for crowded room
24°C
Cooling
operation
After 30 minutes*
Returns to
Automatically returns to
preset temperature (27ºC)
automatically
27°C
*Setting possible for after 30, 60, 90,
and 120 minutes.
Off timer (programmed)
- Sets and saves setting for an increment of time that
automatically turns off air conditioner after a preset period
of time for each time operation starts.
- Period can be preset from 30 to 180 minutes in 10-minute increments.
control configurations and control of multiple indoor units.
Convenience
Weekly schedule
NEW
- 5 actions per day can be scheduled for each day of the week.
- The holiday function will disable schedule timer for the days that have been set as
holiday.
- 3 independent schedules can be set. (e.g. summer, winter, mid-season)
College classroom sample (a summer Monday case)
1) 8:30
ON
2) 10:00
The first period starts and the
air conditioner starts the cooling
operation.
OFF
3) 13:00
In the second period, the classroom
is unoccupied and the air conditioner
stops.
ON
ON
4) 15:00
When the third period starts,
operation starts again.
OFF
OFF
After the third period, the classroom
becomes vacant again and the
air conditioner stops.
ON
OFF
Multilingual display
Display is available in 11 languages.
(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).
LCD wireless remote controller
The wireless remote controller is supplied in a set with a signal receiver.
Signal receiver unit is contained inside decoration panel or indoor unit.
Shape of signal receiver unit differs according to the indoor unit.
Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the
ceiling mounted cassette type.
Signal receiver unit
(For ceiling mounted
cassette type)
Wireless remote controller for each indoor unit type
Heat pump
CEILING SUSPENDED TYPE
71-125BV
WALL MOUNTED TYPE
SkyAir shares common control with the Heat
Reclaim Ventilator and other Daikin
air-conditioning units, thus simplifying interlocking
operations.
LCD remote controller
for SkyAir indoor unit
BRC7EA63W
BRC7GA53
100CA
BRC7F632F
Wireless remote controller
BRC7F632F
CEILING MOUNTED CASSETTE TYPE
BRC7EB518
SkyAir
Indoor unit
Interlocking
Interlocking
Heat Reclaim
Ventilator
16
Simple system provides a diverse assortment of control modes.
Control pattern
Control by 1
remote controller
(Basic system)
Control by 2
remote controllers
For control from 2
locations such as in
room and control room,
exits, etc.
Group control
Control by
external command
Wired remote controller
Wireless remote controller
Non-polar, double-core
(max. wiring length 500 m)
For simultaneous
control of up to 16
indoor units.
Operation and
surveillance is carried out
using the contact signal
from the operation control
box in the building
surveillance (security)
room.
Signal receiver unit installed
on indoor unit
Not possible
(See note 2, 3)
Connects 2 wired remote
controllers (See note 1)
Automatic address setting function
Automatic address setting function
Signal receiver unit installed
on 1 indoor unit
Optional wiring adaptor for
electrical appendices is necessary
Optional wiring adaptor for
electrical appendices is necessary
Central remote controller (option)
Centralised remote
control
Central remote controller (option)
Centralised control of
up to 64 indoor groups
from remote location
up to 1 kilometer away.
Optional SkyAir series interface
adaptor required (See note 4)
Link by remote
controller group control.
Interlock control
with Heat Reclaim
Ventilator
Optional SkyAir series interface
adaptor required (See note 4)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Can be operated simultaneously
or independently by remote controller
(set by ventilation mode)
Can be operated simultaneously
by remote controller
(set by ventilation mode)
Central remote controller (option)
Zone link control by
centralised control.
Central remote controller (option)
Heat Reclaim
Ventilator
Heat Reclaim
Ventilator
Heat Reclaim Ventilator for indoor units within a zone are operated by
interlocking. Can also be operated independently by remote controller.
Heat Reclaim Ventilator for indoor units within
a zone are operated by interlocking
Note:1.BRC1E62 can connect to BRC1E62 only.
2
.It is not possible to use two wireless remote controllers.
3
.BRC1E62 cannot connect to wireless remote controller.
4
.The ceiling mounted cassette type <Round Flow>, ceiling suspended type(140CA only), and wall mounted type come standard with an interface adaptor for SkyAir series.
Easily adaptable to large-scale, high-function, centralised remote control system.
Central remote controller
DCS302CA61 (Option)
Centralised control, with a setting as
simple as it is with a standard
remote controller, of up to 64 groups
(1,024 indoor units) is possible.
Interface adaptor for SkyAir series
DTA112BA51 (Option)
17
Unified on/off controller
DCS301BA61 (Option)
Centralised control of on/off by
group or all at once for up to 256
indoor units.
Schedule timer
DST301BA61 (Option)
Unified control of weekly schedule
for up to 1,024 indoor units.
Schedule timer sets on/off time in 1 minute units
to be executed twice a day for a week at a time.
Enables centralised control via connection to a high-speed,
DIII-NET communication system, adopted for the Daikin
VRV system.
Necessary for interface adaptor for SkyAir series with the central remote
control units shown at above.
DCS601C51 (Option)
With its high functionality, the full
colour “all-in-one” graphic controller
facilitates management of SkyAir
System in a variety of ways.
The interface adaptor for the SkyAir series is
optional except for the ceiling mounted cassette
type <Round Flow>, ceiling suspended type
(140CA only), and wall mounted type.
Abundance of features that provide comfortable
air-conditioning in stores and offices.
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Comfort
High-ceiling application
Auto-swing
Delivers comfortable
air-conditioning to all areas, near
to and far from the air-conditioner.
The air flow direction can be
fixed at your desited angle by
the remote controller.
Applicable for ceiling mounted cassette type and ceiling suspended type.
You can freely set 2 air discharge settings by remote controller.
Delivers
air-conditioning
comfort all the way
down to the floor in
air-conditioning zones
with high ceilings.
(1) Air direction in standard
setting
Note:When units are installed on high ceilings, depending on the model, various
restrictions concerning maximum height, air discharge direction, and choice
of options may apply.
Swing pattern selection
(standard, ceiling soiling prevention)
(2) Air direction in ceiling soiling
prevention
setting
Two selectable temperature-sensors
Draft prevention function
(heating)
To prevent cold air drafts, automatically adjusts airflow to near
horizontal position when heating initially starts or when the
thermostat turns off.
Switchable fan speed
High setting provides maximum reach while low setting
minimises drafts.
Auto airflow rate
Airflow rate is automatically controlled in accordance with the
difference between room temperature and set temperature.
High fan speed mode
Applicable for wall mounted type.
You can increase fan speed approximately 10% higher than the
"high" setting.
Programme "Dry"
Dehumidification is a microprocessor controlled to prevent abrupt
and uncomfortable changes in air temperature. Useful for
reducing uncomfortable humidity without uncomfortable cooling
of the room.
Temperature-sensors are included in the indoor unit and optional
wired remote controller. Temperature sensing closer to the
target area is possible to further
increase the comfort level.
Use the temperature-sensor in the
indoor unit when controlling air
conditioning from another room.
Note: Wireless remote controllers have no
temperature-sensor.
Hot start
(after defrost)
Cold air flow is avoided when heating operation starts or when
switching to heat after defrosting.
Year-round cooling applicable
Efficient cooling even in winter when the indoor temperatures are
higher than those outside, such as in underground public spaces
or offices with many computers.
Night quiet operation
The Automatic night quiet mode will initiate 8 hours after the
peak temperature is reached in the daytime, and normal
operation will resume 10 hours after that.
Remote Controller
Setpoint auto reset
Even if the set temperature is changed, it returns to the preset
temperature after a preset period of time.
Setpoint range set
Saves energy by limiting the minimum and maximum set
temperatures. Avoids excessive heating and cooling.
Weekly schedule timer
Up to five operation ON/OFF settings can be programmed per
day for each day of the week. Not only can the time be set for the
operation ON setting, but also the temperature.
Off timer (programmed)
Sets and saves setting for an increment of time that
automatically turns off air conditioner after a preset period of time
for each time operation starts.
Cleanliness
Anti-bacterial air filter
The Air filter has a anti-bacterial treatment to help prevent the
growth of bacteria and mould on it.
Silver ion anti-bacterial drain pan
Mould-proof drain pan includes a silver ion antibacterial agent
that assists in preventing the growth of slime, bacteria, and
mould that cause smells and clogging.
Mould-proof air filter
Sanitary filter has mould-resistant treatment.
18
Note: Some features only available on selected models. See model pages for full list of features applicable to each unit.
Work and Servicing
Drain pump mechanism
Applicable for ceiling mounted cassette type and ceiling suspended type.
Steeper gradient realises more
efficient condensate drainage.
High-lift is especially useful for long
lengths of drain piping.
Pre charged for up to 30 metres
If the refrigerant piping length does not exceed 30 m, there is no
need for on-site gas charging.
Filter sign
The filter sign warns you when it is time to clean the filter.
*When using a wired remote controller the sign is displayed in the LCD. When
using a wireless remote controller the filter sign lamp illuminates on the signal
receiver unit.
Ceiling soiling prevention function
Low gas pressure detection
Insufficient gas charging is normally hard to detect. During
post-installation trials and regular inspection procedures, the
refrigerant level is monitored by a microprocessor to maintain
proper gas pressure. Reliability is assured and maintenance and
inspection can be carried out more quickly.
Emergency operation
If there is a malfunction elsewhere in the system, the fan or
compressor can still be operated.
Self diagnosis function
The operating parameters of indoor and outdoor units, and
sensor data at critical locations throughout the system, are
constantly monitored using a microcomputer. To facilitate a quick
response in the event of a malfunction, a message appears on
the LCD of the remote controller and an LED on the unit
illuminates.
Applicable for ceiling mounted cassette type.
Daikin's innovative air discharge mechanism keeps airflow away
from the ceiling. Ceiling cleaning is less frequently required.
Control features
Auto-restart
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the power cut
when electricity is restored.
Auto cool/heat change-over (Heat pump only)
Detects difference in preset temperature and actual room
temperature and automatically switches to cooling or heating
accordingly.
Control by 2 remote controllers
Using 2 remote controllers you can operate the equipment locally
or from a remote location.
Note: When a wireless remote controller is used, remote control by two remote controllers is
not possible.
Group control by 1 remote controller
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings
must all be the same and on/off will be simultaneous.)
External command control
Operation and surveillance is carried out using the contact signal
from the operation control box in the building surveillance
(security) room.
*Required for KRP58M51 (Option)
Central remote control
An optional central remote controller enables centralised control
of up to 1024 indoor units (64 groups) from up to 1 kilometer
away.
Interlock control
Enables interlocking control with external equipment such as
Heat Reclaim Ventilator.
DIII-NET communication standard
Standardly equipped interface enables connection to centralised
control system without need of an adaptor.
Options
High-efficiency filter unit
Applicable for ceiling mounted cassette type.
Two types are available: 65% and 90% colorimetry.
Fresh-air intake kit
Applicable for ceiling mounted cassette type.
You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as
required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional
PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit is limited
to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities
will increase the operating noise and may also influence temperature sending.
Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat
exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.
In high corrosive areas, regular maintenance needs to be carried out.
19
SPECIFICATIONS
CEILING MOUNTED CASSETTE TYPE
50
Model
Name
100
125
140
100
125
140
Outdoor unit
RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
kW
kW
Cooling1
Heating2
Unit
Colour
Decoration panel
Airflow rate (H/L)
(H/L)3
Outdoor
unit
71
FCQ50KVEA FCQ60KVEA FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
Indoor
unit
60
Indoor unit
Sound pressure level
Sound power level (H/L)4
Dimensions Unit
(HXWXD)
Decoration panel
Machine
Unit
weight
Decoration panel
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating3
level
Night quiet mode
Sound power level 4
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
5.0
(3.2-5.6)
6.0
(3.5-7.0)
1.27
1.41
3 Phase, 415 V, 50 Hz
12.5
13.6
10.0
12.5
13.6
(5.7-14.0)
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
(6.2-15.4)
14.0
16.0
11.2
14.0
16.0
(6.0-16.2)
(6.2-18.0)
(5.1-12.8)
(6.0-16.2)
(6.2-18.0)
4.02
4.54
2.94
3.77
4.39
3.83
4.80
3.03
3.83
4.80
---------White
533/333
550/375
550/375
533/333
550/375
550/375
32/20
33/22.5
33/22.5
32/20
33/22.5
33/22.5
43/32
44/34
44/36
43/32
44/34
44/36
60/50
61/52
61/54
60/50
61/52
61/54
298X840X840 298X840X840 298X840X840 298X840X840 298X840X840 298X840X840
50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950
24
24
24
24
24
24
5.5
5.5
5.5
5.5
5.5
5.5
14 to 25
15 to 27
White
Hermetically sealed scroll type
1.9
2.4
3.1
1.7
2.2
2.9
3.7
3.7
3.7
4.3
4.3
4.3
(Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
49/51
50/52
50/52
49/51
50/52
50/52
45
45
46
45
45
46
65
----------65
----------1,170X900X320 1,170X900X320 1,170X900X320 1,345X900X320 1,345X900X320 1,345X900X320
98
98
98
108
108
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 9.5
o/ 9.5
o/ 9.5
o/ 9.5
o/ 9.5
o/ 15.9
o/ 15.9
o/ 15.9
o/ 15.9
o/ 15.9
o/ 15.9
I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
75
(Equivalent length 90)
30
Both liquid and gas piping
1 Phase, 240 V, 50 Hz
7.1
10.0
(3.2-8.0)
(5.0-11.2)
8.0
11.2
(3.5-9.0)
(5.1-12.8)
1.99
2.94
2.10
3.03
5.8
(3.2-6.0)
7.0
(3.5-8.0)
1.51
1.74
350/225
350/225
350/225
/s
m3/min
21/13.5
21/13.5
21/13.5
dB(A)
35/28
35/28
35/28
dB(A)
53/46
53/46
53/46
mm 256X840X840 256X840X840 256X840X840
mm
50X950X950 50X950X950 50X950X950
kg
21
21
21
kg
5.5
5.5
5.5
°CWB
°CDB
Hermetically sealed swing type
1.7
1.3
1.6
2.75
2.75
2.75
kg
(Charged for 30 m) (Charged for 30 m) (Charged for 30 m)
dB(A)
48/50
48/50
48/50
44
44
44
dB(A)
dB(A)
66
66
66
mm 770X900X320 770X900X320 770X900X320
kg
68
68
68
°CDB
°CWB
mm
o/ 9.5
o/ 9.5
o/ 9.5
mm
o/ 15.9
o/ 15.9
o/ 15.9
mm
I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32
mm
o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole)
50
m
30
(Equivalent length 70)
m
kW
CEILING SUSPENDED TYPE
Model
Name
71
100
125
140
100
125
140
Indoor unit
FHQ71BVV1B
FHQ100BVV1B
FHQ125BVV1B
FHQ140CAVEA
FHQ100BVV1B
FHQ125BVV1B
FHQ140CAVEA
Outdoor unit
RZQ71KCV4A
RZQ100KCV4A
RZQ125KCV4A
RZQ140KCV4A
RZQ100HAY4A
RZQ125HAY4A
RZQ140HAY4A
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
Indoor
unit
kW
kW
Cooling1
Heating2
kW
kW
Colour
Airflow rate (H/M/L)
(H/M/L)3
Outdoor
unit
Sound pressure level
Sound power level (H/M/L)4
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Type
Compressor
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating3
level
Night quiet mode
Sound power level Cooling/Heating4
X
Dimensions (H WXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
/s
m3/min
dB(A)
dB(A)
mm
kg
°CWB
°CDB
5.8
(3.2-8.0)
7.5
(3.5-9.0)
1.77
2.32
283/-/233
17/-/14
39/-/35
55/-/51
195X1,160X680
27
Hermetically
sealed swing type
1.7
2.75
kg
(Charged for 30 m)
dB(A)
48/50
dB(A)
44
dB(A)
66
mm
770X900X320
kg
68
°CDB
°CWB
mm
mm
mm
mm
50
m
(equivalent length 70)
m
kW
1 Phase, 240 V, 50 Hz
9.2
11.2
(5.0-11.2)
(5.7-14.0)
10.5
13.5
(5.1-12.8)
(6.0-16.2)
2.93
3.70
3.33
4.35
White
400/-/333
500/-/417
24/-/20
30/-/25
42/-/37
44/-/39
58/-/53
60/-/55
195X1,400X680 195X1,590X680
32
35
13.2
(6.2-15.4)
16.0
(6.2-18.0)
4.40
5.00
Fresh white
567/483/400
34/29/24
46/42/38
64/60/56
235X1,590X690
38
14 to 25
15 to 27
White
3 Phase, 415 V, 50 Hz
13.2
9.2
11.2
(6.2-15.4)
(5.0-11.2)
(5.7-14.0)
10.5
13.5
16.0
(5.1-12.8)
(6.0-16.2)
(6.2-18.0)
2.85
3.55
4.33
3.26
4.35
4.93
White
Fresh white
567/483/400
400/-/333
500/-/417
34/29/24
24/-/20
30/-/25
42/-/37
44/-/39
46/42/38
58/-/53
60/-/55
64/60/56
195X1,400X680 195X1,590X680 235X1,590X690
38
32
35
Hermetically sealed scroll type
1.9
49/51
65
2.4
3.7
(Charged for 30 m)
50/52
45
67
1,170X900X320
98
3.1
2.3
49/51
46
------
65
2.7
4.3
(Charged for 30 m)
50/52
45
67
1,345X900X320
108
2.9
46
------
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP20 (External Dia, 26/Internal Dia. 20)
o/ 26.0 (Hole)
75
(equivalent length 90)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
4
Numerical values are according to ISO 3741:1999.
20
SPECIFICATIONS
WALL MOUNTED TYPE
Indoor unit
Model
Name
Outdoor unit
Power supply
Cooling capacity1
Rated (Min. - Max.)
Heating capacity2
Rated (Min. - Max.)
Power consumption
Indoor
unit
71
100
100
FAQ71CVEA
FAQ100CVEA
FAQ100CVEA
RZQ71KCV4A
RZQ100KCV4A
RZQ100HAY4A
1 Phase, 240 V, 50 Hz
kW
kW
Cooling1
Heating2
Colour
Airflow rate (H/M/L)
Sound pressure level (H/M/L)3
Sound power level (H/M/L)4
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Colour
Outdoor
Type
Compressor
unit
Motor output
Refrigerant charge (R-410A)
Sound pressure Cooling/Heating3
level
Night quiet mode
Sound power level Cooling/Heating4
Dimensions (HXWXD)
Machine weight
Cooling
Certified
Operation range Heating
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
kW
kW
/s
m3/min
dB(A)
dB(A)
mm
kg
°CWB
°CDB
kW
kg
dB(A)
dB(A)
dB(A)
mm
kg
°CDB
°CWB
mm
mm
mm
mm
m
m
7.1
(3.2-8.0)
8.0
(3.5-9.0)
2.20
2.33
300/267/233
18/16/14
45/42/40
61/58/56
290X1,050X238
13
Hermetically sealed swing type
1.7
2.75 (Charged for 30 m)
48/50
44
66
770X900X320
68
50 (Equivalent length 70 m)
3 Phase, 415 V, 50 Hz
10.0
(5.0-11.2)
11.2
(5.1-12.8)
3.19
3.45
White
14 to 25
15 to 27
Ivory white
3.44
433/383/317
26/23/19
49/45/41
65/62/58
340X1,200X240
17
Hermetically sealed scroll type
1.9
1.7
3.7 (Charged for 30 m)
4.3 (Charged for 30 m)
49/51
45
65
1,170X900X320
1,345X900X320
98
108
-5 to 46
-15 to 15.5
o/ 9.5
o/ 15.9
VP13(External Dia, 18/Internal Dia. 13)
o/ 26.0 (Hole)
75 (Equivalent length 90 m)
30
Both liquid and gas piping
Note :
1
Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)
3
Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
4
Numerical values are according to ISO 3741:1999.
21
OPTIONS
Indoor unit
CEILING MOUNTED CASSETTE TYPE
Name of option
Remark
FCQ50KVEA
FCQ60KVEA
Decoration panel
Sealing material of air discharge outlet
Panel spacer
Fresh air
Chamber
type
intake kit1
Without the T-joint pipe and fan
With the T-joint pipe, without fan
Direct installation type
2
Chamber connection kit
Insulation kit for high humidity
(Colorimetric method 65%)
High-efficiency filter
(including chamber)
(Colorimetric method 90%)
Replacement
(Colorimetric method 65%)
high-efficiency filter
(Colorimetric method 90%)
Filter chamber
Branch duct chamber
Wireless type
Heat pump
Remote controller
Wired type3 "Nav Ease"
Central remote controller4
Unified ON/OFF controller4
Schedule timer4
Touch Controller4
Adaptor for wiring5
Group control adaptor5
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
KDTP55K80
KAFP556B80
KAFP557B80
KAFP552B80
KAFP553B80
KDJP55B80
Kit name
FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA
BYCP125K-W1
KDBH55K160F
KDBP55H160FA
KDDP55B160
KDDP55B160K
KDDP55X160
KKSJ55KA160
KDTP55K160
KAFP556B160
KAFP557B160
KAFP552B160
KAFP553B160
KDDFP55B160
KDJP55B160
BRC7F632F
BRC1E62
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP1C63
KRP4AA53
KRP1H98
KRCS01-4B
Note: 1Refer to page 8 for the details.
2
Required for installing high-efficiency filter or ultra long-life filter.
3
Wiring for wired remote controller to be procured locally.
4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
5
Installation box for adaptor PCB (KRP1H98) is necessary.
Round flow type: List of optional parts required to achieve different flow patterns
For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.
All-round flow
4-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Filter related
High-efficiency filter2
3-way flow
Panel spacer1
o
o
o
x
o
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o
x
x
o
o
o
x
o
o
High-humidity
operation kit
x
o
x
o
x
High-efficiency
filter2
o
o
o
o
x
2-way flow
Optional accessory parts
Independently installable optional parts
Panel/grille related
Panel spacer1
Operation control related
Wireless remote controller
Auxillary function related
Fresh air intake kit (Chamber type)1,2
Fresh air intake kit (direct mount)
High-humidity operation kit
Panel spacer1
o3
o3
o3
x
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o3
o
o
o
o3
o
x
x
o3
o
x
o
High-humidity
operation kit
High-efficiency
filter2
High-humidity
operation kit
High-efficiency
filter2
x
o
x
o
x
x
x
x
x
Branch duct connection
Optional accessory parts
Independently installable optional parts
Branch duct1
1-way branch / unit 3-way flow
(Chamber type)
2-way branch / unit 2-way flow
(Round duct type)
1-way branch / unit 2-way flow
Panel spacer1
o
x
x
Wireless
Fresh air intake kit Fresh air intake kit
remote controller (Chamber type)1,2
(direct mount)
o
o
o
o
o
o
o
o4
o4
4
x
x
x
x
x
x
1
In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check
whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.
2
22
OPTIONS
Indoor unit
CEILING SUSPENDED TYPE
Name of option
Remark
Fresh air intake kit
Drain pump kit
L-type piping kit (for upward direction)
Remote controller
FHQ71BVV1B
Wireless type
Heat pump
Wired type1 "Nav Ease"
Central remote controller
Unified ON/OFF controller
Schedule timer
Touch Controller
Adaptor for wiring
Wiring adaptor for electrical appendices4
Interface adaptor for SkyAir series
Installation box for adaptor PCB
Remote sensor (for indoor temperature)
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
Kit name
FHQ100BVV1B
FHQ125BVV1B
---------KDU50N125VE
KHFP5MA160
BRC7EA63W
BRC1E62
DCS302CA61 2
DCS301BA61 2
DST301BA61 2
DCS601C51 2
KRP1BA54
KRP4AA52
DTA112BA51
KRP1CA93
KRCS01-1B
KJB311AA
KJB212AA
FHQ140CAVEA
KDDQ50A140
KDU50P140VE
KHFP5N160
BRC7GA53
DCS302CA61 3
DCS301BA61 3
DST301BA61 3
DCS601C51 3
---------KRP1D93A
KRCS01-4B
Note: 1Wiring for wired remote controller to be procured locally.
2
This optional accessory requires DTA112BA51.
3
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
4
Installation box for adaptor PCB is necessary.
WALL MOUNTED TYPE
Name of option
Kit name
Remark
Drain-up kit
Remote controller
FAQ71CVEA
FAQ100CVEA
K-KDU572EVE
BRC7EB518
BRC1E62
KRCS01-4B
DCS302CA61
DCS301BA61
DST301BA61
DCS601C51
KRP4AA51
KRP4AA93
KJB311AA
KJB212AA
KEK26-1A
Heat pump
Wireless type
Wired type1 "Nav Ease"
Remote sensor (for Indoor temperature)
Central remote controller2
Unified ON/OFF controller2
Schedule timer2
Touch Controller2
Wiring adaptor for electrical appendices3
Installation box for adaptor PCB
Electrical box with earth terminal (3 blocks)
Electrical box with earth terminal (2 blocks)
Noise filter ( For electromagnetic interface use only)
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
3
Installation box for adaptor PCB (KRP4AA93) is necessary.
Outdoor unit
Name of option
Central drain plug
Wire fixture for preventing overturning
Fixture for preventing overturning
Demand adaptor
23
Kit name
Heat pump
RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A
RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A
RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A
KKPJ5F180
K-KYZP15C
KPT-60B160
KRP58M51
DIMENSIONS
(Unit: mm)
CEILING MOUNTED CASSE TTE TYPE
[FCQ50-140KVEA]
[FCQ50-140KVEA]
[FCQ50-71KVEA]
[FCQ100-140KVEA]
B
167
160
67
29
95
160
67
95
29
80
C/L
Connection position
of branch duct
(round shape type)
Connection position
of fresh air intake kit
(direct installation type)
90
90
167
93
157
350
2 100=200 80
213
25
160
157
350
2x100=200 80
25
124
80
160
213
95
110
124
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
C/L
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
ø1
Connection position
(kn 00
of branch duct
ock
hole
(round shape type)
)
90
Connection position
183
of fresh air intake kit
C
arrow
view
(direct installation type)
4
1
2
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
55
85
27-M4 Prepared hole
5
256
157
350
A
67
160
64
50
840
2 100=200
160
60
105
81
35 or less
(Note 4)
Connection position
of branch duct
(square-shaped type)
1500 or more
(required space)
From the floor side 2500 or more
For height installation
157
280
330
A
42
125
165
20 C/L
350
157
350
3 55
150
160
298
95
167
850
Adjustable(0~675)
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
Connection position
of branch duct
(square-shaped type)
B arrow view
ø1
(kn 00
holock
e)
90
196
C arrow view
[FCQ100-140KVEA]
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
175
29
50
40
160
288
10
840
340
80 2 100=200 80
160
256
1500 or more
(required space)
From the floor side 2500 or more
For height installation
2
27-M4 Prepared hole
55
5
130
60
840
81 2x100=200 85
64
124
50
42
105
55
[FCQ100-140KVEA]
55
157
350
[FCQ100-140KVEA]
160
124
109
95
Connection position
of branch duct
(square-shaped type)
20-M4
Prepared hole
95
167
93
29
280
330
1
150
124
256
850
Adjustable(0~675)
95
110
125
165
4
3
35 or less
(Note 4)
Connection position
of branch duct
(round shape type)
157
350
Connection position
of branch duct
(square-shaped type)
[FCQ50-71KVEA]
7
[FCQ50-71KVEA]
175
29
160
246
10
50
40
20 C/L
Hanging bolt
4-M8~M10
Connection position
of branch duct
(round shape type)
16-M4 Hole
6
16-M4 Prepared hole
55 Connection position
of branch duct
(square-shaped type)
80
Connection position
85 of branch duct
(round shape type)
2 100=200
160
C/L
Drain Connection
Side
[FCQ50-71KVEA]
340
80 2 100=200
124
157
350
B arrow view
A arrow view
840
81
93
160
124
950
C
85 Connection position
of branch duct
(round shape type)
16-M4 Hole
95
110
Note 2
8
Piping Connection
Side
420
55
2x100=200
124
C/L
81
950
780(Hanging bolt pitch)
860~910(Ceiling opening space) (Note 4)
9
860~910(Ceiling opening space) (Note 4)
710(Hanging bolt pitch)
420
130
300
or less
Notes:
1
Sticking location for manufacture's label
manufacture's label for indoor unit:
Suction grille inner side's electric components box's lid surface
manufacture's label for decoration panel :
Decoration panel's corner decoration cover inner surface
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller
in detail.
3
When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit
continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.
4
Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less
between the indoor unit and the ceiling opening so that
the panel overlap allowance can be ensured.
5
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
Required space
200mm or more
1500mm or more
1500mm
or more
1500mm
or more
200mm
or more
1500mm or more
The necessary space is 500mm or more when the
air-outlet is blocked with the accessory.
Moreover when the corner areas are blocked
(both right and left of the blocked air outlet),
the necessary space is 200mm or more.
1
2
3
4
5
6
7
8
9
Liquid piping connection
Gas piping connection
Drain piping connection
Transmission wiring connection
Remote controller wiring
connection
Air-outlet
Suction grille
Corner decoration cover
Drain hose (accessory)
24
DIMENSIONS
(Unit: mm)
CEILING SUSPENDED TYPE
5
(Required space)
6
115 60
11
5
B
30 or more
(Service space)
30 or more
(Service space)
4 o/ 45
Brand name plate
(Note.2)
The Front
Obstacle
Floor side
225
275
300
275
80
2
65
Position : Hole of wall for taking out in piping back
(View from the front)
80
105
170
5
7
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
55
14
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas piping connection
5 Liquid piping connection
6 Drain piping connection
7 Earth terminal (inside the electric components box) (M4)
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side piping connection
12 Left back drain piping connection
13 Left side drain piping connection
14 Right side drain piping connection
15 Hole of wall for taking out in piping back
16 Upward drain piping connection
17 Upward gas piping connection
18 Upward liquid piping connection
6
3
80
90
155
300 or more
55
(Required space)
For height installation
13
105
15
1
Drain piping connection VP20
(For left piping)
3
135
8
195
From the floor side 2500 or more 155
10
Hanging bolt
4-M8~M10
65
60
Position slit hole for taking out in piping back
(View from the front)
127
A
(Hanging position)
680
50
5
135 (Required space)
1550 1590
145 60
40
1360 1400
FHQ125BVV1B
210
FHQ100BVV1B
260
1120 1160
9
12
85
102
160
185
192 36
B
FHQ71BVV1B
(Hanging
position)
A
170
105
90
18 17 16 142 58
40
[FHQ71-125BVV1B]
4
(Applies to FHQ71BV only)
The remote control code is the standard <about 3 m outside the machine> attached.
(0.5 mm2 2 wicks O.D. 5.4)
(It is not attached to heat reclaim ventilator.)
CEILING SUSPENDED TYPE
12
Position slit hole for taking out in piping back
(View from the front)
1550
(Hanging bolt pitch)
690
Hanging bolt
4-M8~M10
4
5
11
Obstacle
Floor side
220
103
30 or more
(Service space)
1590
30 or more
(Service space)
The Front
Brand name plate
(Note.2)
214
221
268
268
6
76
3
2
7
5
83
105
156
4
Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit.
When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.
6
o/ 45
57
14
63
134 59
175
235
300 or more
(Required space)
57 13
19 15
91
131
197
1
157 63
115
90
175
92
51 60
8
5
(Required space)
From the floor side 2500 or more 197
For height installation
10
Drain piping connection VP20
(For left piping)
25
9
5
(Required space)
260
116
Connection position of fresh air intake kit
φ100(Knock out hole)
120
90
40
(Hanging
bolt pitch)
210
18 17 20 16
210
156
105
102
131 57
30
87
100
163
189
195 35
[FHQ140CAVEA]
Position : Hole of wall for taking out in piping back
(View from the front)
1 Air discharge grille
2 Air suction grille
3 Air filter
4 Gas piping connection
5 Liquid piping connection
6 Drain piping connection
7 Earth terminal (inside the control box) (M4)
8 Hanger
9 Rear piping penetration cover
10 Top panel penetration cover
11 Right side piping connection
12 Left back drain piping connection
13 Left side drain piping connection
14 Right side drain piping connection
15 Hole of wall for taking out in piping back
16 Upward drain piping connection
17 Upward gas piping connection
18 Upward liquid piping connection
WALL MOUNTED TYPE
[FAQ71CVEA]
50 or more
(Required space)
Piping direction
Approx.400
240
238
30 or more
(Required space)
7
290
Dimensions
for full open
front panel
9
3
Piping direction
1
Name plate Note)2
50 or more
(Requred space)
Piping direction
1050
14.5
2
8
104
50 or more
(Requred space)
894
2500 or more
For installation
in high spaces
120 or less
52
φ80 hole
Piping and
Wiring intake
Outside line
60
Mounting location
6
5
4
Approx.345
98
Approx.390
44
44
105
φ80 hole
1
2
3
4
5
6
7
8
9
Approx.475
Notes:
1
Location of unit's of Name Plate:Right side surface of casing
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more,
and the drain outlet are choked up and the air filter are dirty, dew may fall.
Front panel
Front grill
Air outlet
Gas piping
Liquid piping
Drain hose
Earth terminal
Right side piping connection hole
Left side piping connection hole
WALL MOUNTED TYPE
[FAQ100CVEA]
242
50 or more
(Required space)
Piping direction
Approx.440
240
Dimensions for
full open
front panel
1
50 or more
(Requred space)
Piping direction
1200
79.5
3
Name plate Note)2
Piping direction
1085
2500 or more
For installation
in high spaces
50 or more
(Requred space)
8
120 or less
35.5
φ80 hole
Outside line
Piping and
Wiring intake
45
45
φ80 hole
6
65
Mounting location
5
4
Approx.400
Approx.460
89
Approx.465
Notes:
1
Location of unit's of Name Plate:Right side surface of casing
2
In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail.
3
Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more,
and the drain outlet are choked up and the air filter are dirty, dew may fall.
114
2
14.5
9
30 or more
(Required space)
340
7
1
2
3
4
5
6
7
8
9
Front panel
Front grill
Air outlet
Gas piping
Liquid piping
Drain hose
Earth terminal
Right side piping connection hole
Left side piping connection hole
26
DIMENSIONS
(Unit: mm)
OUTDOOR UNIT // RZQ50KBV4A, 60KBV4A, 71KCV4A
43
61
320
350
(345~355)
30
Hole for anchor
bolt 4-M12
140
30
41
3
4
2
1
7
6
5
7
6
5
89
28
89
142
71
19
223
53 95
19
80
52
145
16
13
67
70 102 117
58
16
8
54 95
84 55
54 95
60
339
341
55
770
30
94
140
620
900
5
45
376
1
2
3
4
5
6
7
8
191
Gas piping connection
Liquid piping connection
Service port
Earth terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake
Transmission wiring intake
Drain piping connection
OUTDOOR UNIT // RZQ100KCV4A, 125KCV4A, 140KCV4A
320
30
22
44
43
350
(345~355)
30
Hole for anchor
bolt 4-M12
94
620
140
140
900
30
3
4
2
1
7
7
7
6
6
5
161
52
145
9
48
12
11
58
3 Service port
4 Earth terminal
42
70 102 117
1 Gas piping connection
2 Liquid piping connection
45
27
71
38.16
19
142
8
40
68
54
19
60
68
64
54
89
60
422
423
5
39.4
5
68.4
1170
6
376
191
5
5 Refrigerant piping intake
6 Power supply wiring intake
7 Transmission wiring intake
8 Drain piping connection
OUTDOOR UNIT // RZQ100HAY4A, 125HAY4A, 140HAY4A
320
55
36
350
(345~355)
(Pitch of foundation bolt holes)
30
Hole for anchor
bolt 4-M12
30
38
91
140
30
620
140
(Pitch of foundation bolt holes)
900
3
4
2
1
6
7
5
6
8
58
71 102 117
376
191
95
80
52
145
13
67
16
5
45
53
19
16
71
84
95
54
19
5
55
435
95
54
416
60
89
24
89
142
6
55
5
7
223
1345
7
1
2
3
4
5
6
7
8
Gas piping connection
Liquid piping connection
Service port
Earth terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake
Transmission wiring intake
Drain piping connection
28
DIMENSIONS
(Unit: mm)
REMOTE CONTROLLER
Wireless type
CEILING MOUNTED CASSETTE TYPE <Round Flow>
Receiver installation procedure
Remote controller holder
installation procedure
<installation to wall
surface>
Remote controller dimensions
•
Transmitting part
Receiver
Refrigerant
piping side
Receiver detail
157
Liquid crystal
remote controller
(wireless)
Remote
controller
holder
62
Drain piping
side
17.5
Decoration panel
WALL MOUNTED TYPE
• Receiver installation procedure
CEILING SUSPENDED TYPE
• Receiver installation procedure
FHQ71-125BVV1B
Receiver
FHQ140CAVEA
The Front
The Front
Receiver
Receiver
• Receiver detail
• Receiver detail
• Receiver
detail
BRC1E62
• Remote controller dimensions
Upper case
• Installation method
Lower case
A Exposed cord
Top left
outlet
42
B Embedded cord
Staple
19
Condit
C Embedded cord
(use switch box)
19
40
84
40
84
Operation
lamp
(Green)
120
Top center
outlet
84
Wired type
120
19
5X7 oblong hole
28
23
48.5
46
Code outlet hole
5X15 oblong hole
48.5
Left outlet
19
Lower case portion
Note)2
28
Through hole
Switch box for one switch
( 8- 10)
ex.) KJB111A
(optional accessory)
Lower case
Note)
1. Remote controller cord and staple are not attached. They are field
supplied parts.
Specifications of cord
29
Type
Vinyl cord with sheath or cable (insulated thickness: 1mm or more)
Size
0.75~1.25 mm2
Total length
500 m
46
0~5
Switch box for two switch (Between remote
ex.) KJB211A
controller and
(optional accessory)
control box)
Switch box
portion
[field supplied part]
2.If the hole size is too large or the location
is not proper, the hole may come out from
the remote controller.
Installation service space for outdoor unit
For RZQ50/60KBV4A, RZQ71KC-140KCV4A, RZQ100-140HAY4A
The values represent the case for the RZQ100-140KCV4A and RZQ100-140HAY4A.
The dimensions in ( ) are for the RZQ50/60KBV4A and RZQ71KCV4A (The unit values is mm. )
1 When there is an obstruction on the inlet side
2 When there is an obstruction on the outlet side
1) When the overhead space is open
1) When the overhead space is open
1. For single unit installation
1. For single unit installation
re
0
0(5
10
100
or m
ore
100
r
0o
or m
100 or more
re
ore
rm
0o
0
10
10
ore
2) When there is an obstruction
in the overhead space
0
50
s
les
or
1. For single unit installation
100 or more
100 or more
00
or
An obstruction
in the overhead space
mo
re
0o
rm
)
00
re
mo
or
0(2
ore
30
2. For series installation
(more than two units)
2) When there is an obstruction
in the overhead space
ss
An obstruction
in the overhead
space
e
or
3 When there are obstructions on both
the inlet and outlet sides
1000 or more
1
ess
rl
0o
ore
rm
0o
0
10
rm
o
00
50
100 or more
1000 or more
r le
0o
50
An obstruction
in the overhead
space
100 or more
ss
r le
0o
50
An obstruction
in the overhead space
1. For single unit installation
When there are obstructions
on the inlet side and
both lateral sides
ore
rm
0o
50
1000 or more
10
20
When there is an
obstruction on the
inlet side
100 or more
mo
2. For series installation
(more than two units)
When there are
obstructions on
both sides
50
2. For series installation
(more than two units)
When there are obstructions
on both sides
ore
rm
0o
mo
r
)o
1000 or more
When there is an
obstruction only
on the inlet side
(When the obstruction on the outlet side is higher
than the unit itself)
1) When the overhead space is open
150
or m
ore
150
e
or
or m
0
ore
15
m
or
(There is no limit to the height of the obstruction on the
outlet side.)
H
1. For single unit installation
An obstruction
in the overhead
space
or
2. For series installation
(more than two units)
100 or more
0
50 ore
m
or
100 or more
100 or more
mo
re
20
0o
rm
ore
)
00
0(2 re
30 r mo
o
L
H
0)
0(5 e
10 mor
or
H
00
H
L
10
r
0o
50
s
les
L
1000 or more
When there are obstructions
on the inlet side and
both lateral sides
100 or more
L
2. For series installation (more than two units)
00
10 ore
m
or
)
00
0(2 re
30 r mo
o
Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.
30
Warning
Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING
MANUFACTURING DIVISION
JMI-0107
Scope of Registration:
The design/development and
manufacture of commercial air
conditioning, heating, cooling,
refrigerating equipment, heating
equipment, residential air conditioning
equipment, heat reclaim ventilation, air
cleaning equipment, compressors and
valves.
DEALER:
Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.
JQA-1452
Scope of Registration:
The design / development
and manufacture of air
conditioners and the
components including
compressors used for them
Quality
ISO 9001
Daikin Australia
Pty Limited (ISO9001)
QEC23256 May 12, 2006
Sydney, Brisbane,
Adelaide,
Melbourne, Newcastle,
Townsville, Perth,
Auckland
All of the Daikin
Group’s business
facilities and
subsidiaries in Japan
are certified under the
ISO 14001
international standard
for environment
management.
Environment
ISO 14001
Daikin Australia
Pty Limited
(ISO14001)
CEM20437
October 27, 2006
Sydney, Brisbane,
Melbourne,
Adelaide, Perth
Daikin Australia Pty Limited
ABN 62 000 172 967
Email: [email protected]
Phone: 1300 368 300 (AU)
Phone: 0800 324 546 (NZ)
commercial.daikin.com.au
Specifications, designs and other content appearing in this brochure are current as of September 2013 but subject to change without notice.
c All rights reserved
09/13 SS