Download 1 Features
Transcript
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 1 AQ i E Rny _Uk B S 3r V o a8t o0B i d1- l 4Qt p-Eu •ROS 1 Features Outdoor units for pair application • • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. • The sevice valves are hidden inside the casing. • Outdoor units are fitted with a scroll compressor, renowned for low noise and high energy efficiency. • A special acryl precoated fin for anti-corrosion treatment on the heat exchanger ensures greater resistance against severe weather conditions 1 1 • Split Sky Air • Outdoor Units The piping connections can be accessed from underneath, front, side or rear. • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 2 Specifications 2-1 NOMINAL CAPACITY AND NOMINAL INPUT For combination indoor units + outdoor units Nominal Capacity Nominal input For combination indoor units + outdoor units Nominal Capacity Nominal input For combination indoor units + outdoor units Nominal Capacity Nominal input For combination indoor units + outdoor units Nominal Capacity Nominal input For combination indoor units + outdoor units 2-2 Indoor Units Dimensions Cooling Standard Heating Standard Cooling Standard Heating Standard EER Cooling COP Heating Energy Cooling Labeling Heating Directive Annual energy consumption Indoor Units Cooling Standard Heating Standard Cooling Standard Heating Standard EER Cooling COP Heating Energy Cooling Labeling Heating Directive Annual energy consumption Indoor Units Cooling Standard Heating Standard Cooling Standard Heating Standard EER Cooling COP Heating Energy Cooling Labeling Heating Directive Annual energy consumption Indoor Units Cooling Standard Heating Standard Cooling Standard Heating Standard EER Cooling COP Heating Energy Cooling Labeling Heating Directive Annual energy consumption Colour Material Unit Packing Weight REQ7 1B8W1 B R EQ100B 8V3B REQ1 00B8W1B REQ125B8 W1B FDEQ71B8V3B FDEQ71B8V3B FDEQ100B8V3B FDEQ100B8V3B FDEQ125B8V3B 3 1 kW kW kW kW 7.1 8 2.79 2.49 2.54 3.21 E C 7.1 8 2.68 2.49 2.65 3.21 D C 9.8 11.2 3.98 3.99 2.46 2.86 E C 9.8 11.2 3.94 3.96 2.49 2.89 E D 12.2 14.5 4.67 4.52 2.61 3.21 D C kWh 1395 FCQ71B8V3B 7.1 8 2.72 2.85 2.61 2.81 D 1340 FCQ71B8V3B 7.1 8 2.66 2.80 2.67 2.86 D 1990 FCQ100B8V3B 10 11.2 3.83 3.75 2.61 2.99 D D 1970 FCQ100B8V3B 10 11.2 3.56 3.66 2.81 3.06 C 2335 FCQ 125B8V3B 12.5 14.6 4.66 5.06 2.68 2.89 D 1360 FBQ71B8V3B 7.1 8 2.79 2.49 2.54 3.21 E C 1330 FBQ71B8V3B 7.1 8 2.68 2.49 2.65 3.21 D C 1915 FBQ100B8V3B 10 11.2 3.79 3.91 2.64 2.86 D D 1780 FBQ100B8V3B 10 11.2 3.6 3.87 2.78 2.89 C D 2330 FBQ125B8V3B 12.5 14.5 4.67 4.52 2.61 3.21 D C 1395 FHQ71BVV1B 7.1 8 2.7 2.85 2.63 2.81 1340 FHQ71BVV1B 7.1 8 2.65 2.8 2.68 2.86 1780 FHQ100BVV1B 9.8 11.2 3.68 4.01 2.66 2.79 2335 FHQ125BVV1B 12.2 14.5 4.51 5.16 2.71 2.81 D D 1885 FHQ 100BVV1B 9.8 11.2 3.75 4.13 2.61 2.71 D E E D 1350 1325 1875 1840 2250 R EQ71B8 V3 B REQ7 1B8W1 B R EQ100B 8V3B REQ1 00B8W1B REQ125B8 W1B 770 900 320 900 980 420 83 87 Daikin W hite Painted galvanized steel plate 1170 900 320 1300 980 420 102 107 1170 900 320 1300 980 420 100 105 1170 900 320 1300 980 420 108 113 kW kW kW kW kWh kW kW kW kW kWh kW kW kW kW kWh TECHNICAL SPECIFICATIONS Casing R EQ71B8 V3 B Unit Packed Unit Height Width Depth Height Width Depth mm mm mm mm mm mm kg kg 770 900 320 900 980 420 83 87 • Split Sky Air • Outdoor Units 2 2 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 2 Specifications 2-2 TECHNICAL SPECIFICATIONS Heat Exchanger Dimensions 1 2 Tube type Fin Fan Motor Fan Motor Fan Compressor Operation Range Sound Level (nominal) Refr iger ant Refr iger ant Oil 3 Length mm Nr of Rows Fin Pitch mm Nr of Passes Face m² Area Nr of Stages REQ71B 8V3B REQ71B8W1B REQ100 B8V3B REQ100B8W1B R EQ125B 8W1B 857 2 2.00 6 0.641 857 2 2.00 6 0.641 857 2 2.00 10 0.980 857 2 2.00 10 0.980 857 2 2.00 10 0.980 34 34 52 52 1 48.0 43.0 1 48.0 43.0 52 Hi-XSS cooling tube Non-symmetric waffle louvr e Anti-corrosion treatment (PE) Direct Dr ive Propeller Horizontal 1 55.0 50.0 1 55.0 50.0 2 89.0 80.0 1 1 1 P47L11S 1 1 3 3 3 3 Lower 3 65 65 90 90 Type Tr eatment Type Dischar ge direction Quantity Air Flow Rate Cooling (nominal at Heating 230V) Motor Quantity Model Position Speed Steps (nominal) Motor Output Position Speed Steps (nominal) Motor Output Quantity Motor Model Type Motor Output Crankcas e Heater Cooling Min Max Heating Min Max Cooling Sound Power Sound Pressure Type Char ge Control Nr of Circuits Type Char ged Volume m³/min m³/min W W 1 JT90G-P4V1N@S 1 1 1 JT90G-YE JT125G-P4V1@S JT125G- YE Hermetically sealed scroll compressor 2200 3000 3000 85 Upper 3 65 1 JT160G-YE W 2200 W 33 33 33 33 33 °CDB °CDB °CWB °CWB dBA 10.0 46.0 -10 15 65.0 10.0 46.0 -10 15 65.0 10.0 46.0 -10 15 70.0 10.0 46.0 - 10 15 70.0 10.0 46.0 -10 15 70.0 dBA 53.0 53.0 57.0 57.0 57.0 kg 2.5 2.5 3.6 3.6 1 1 1 1 1.5 1.5 1.5 1.5 l • Split Sky Air • Outdoor Units R-410A 3.6 Expansion valve ( electr onic type) 1 Daphne FVC68D 1.5 3750 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 2 2-2 Specifications TECHNICAL SPECIFICATIONS Piping connections Liquid ( OD) Gas Drain Piping Length Quantity Type Diameter (OD) Quantity Type Diameter (OD) Quantity Type Diameter (OD) Minimum Maximum Equivalen t Chargele ss Maximum Installation height difference Max. internunit level difference Heat Insulation R EQ71B8 V3 B REQ7 1B8W1 B R EQ100B 8V3B REQ1 00B8W1B REQ125B8 W1B 1 1 1 1 9.52 9.52 1 Flare connection 9.52 9.52 9.52 1 1 1 1 15.9 15.9 15.9 15.9 3 3 mm 26 m m m mm mm 3 3 26 3 Hole 26 26 26 5 50 70 5 50 70 5 50 70 5 50 70 5 50 70 m 7.5 7.5 7.5 7.5 7.5 m 30.0 30.0 30.0 30.0 30.0 m 0.5 0.5 0.5 0.5 0.5 Item Quantity Item Quantity Notes 2-3 ELECTRICAL SPECIFICATIONS Power Supply Current Name Phase Frequency Voltage Voltage range 1 2 Both liquid and gas pipes Reversed cycle Sensor for outdoor heat exchanger temperature None Reverse phase pr otector PC board fuse Overcurr ent relay (compressor) Low pressure switch High pressure switch Fan motor thermal protector Declaration of conformity 1 1 1 1 1 Installation manual 1 1 1 1 1 Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound level drawings of this chapter. The sound power level is an absolute value indicating the power which a sound source generates. Sound values ar e measured in a semi-anechoic r oom. In case of drain piping for outdoor unit, drain piping kit ( option) is needed. Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35° CDB, equivalent refriger ant piping : 7.5m, level differ ence : 0m. Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB, equivalent refr iger ant piping : 7.5m, level differ ence : 0m Defrost Method Defrost Control Capacity Control Method Safety Devices Standard Accessories 1 Flare connection 15.9 3 Hz V Minimum V Maximum V Recomended fuses A R EQ71B8 V3 B REQ7 1B8W1 B R EQ100B 8V3B REQ1 00B8W1B REQ125B8 W1B V3 1 50 230 W1 3N 50 400 W1 3N 50 400 W1 3N 50 400 32 16 V3 1 50 230 -10% +10% 40 16 20 • Split Sky Air • Outdoor Units 4 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 2 Specifications 2-3 ELECTRICAL SPECIFICATIONS Wiring connections 1 2 5 For Power Supply Quantity Remark For connection Quantity with indoor Remark Power Supply Intake REQ71B 8V3B REQ71B8W1B 1 3 wires (earth wire included) 1 1 5 wir es ( earth wire included) 1 • Split Sky Air • Outdoor Units REQ100 B8V3B REQ100B8W1B 1 1 3 wires (earth wire 5 wires (ear th wire included) included) 1 1 4 wires ( earth wire included) Outdoor unit only R EQ125B 8W1B 1 5 wir es ( earth wir e included) 1 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 3 Electrical data 3 REQ71B Unit combination Indoor unit Outdoor unit Hz-Volts Power supply Voltage range MCA TOCA MFA Compressor LRA RLA OFM IFM kW FLA kW FLA FCQ71 REQ71BV3 50-230 16.6 23.3 32 75.5 12.2 0.065 0.6 0.045 0.7 FHQ71 REQ71BV3 50-230 16.8 23.2 32 75.5 12.5 0.065 0.6 0.062 0.6 FBQ71 REQ71BV3 50-230 17.4 23.5 32 75.5 12.7 0.065 0.6 0.125 0.9 FDEQ71 REQ71BV3 50-230 15.4 23.5 32 75.5 11.1 0.065 0.6 0.125 0.9 FCQ71 REQ71BW1 50-400/230 7.3 11.3 16 41.1 4.8 0.065 0.6 0.045 0.7 FHQ71 REQ71BW1 50-400/230 7.5 11.2 16 41.1 5.0 0.065 0.6 0.062 0.6 FBQ71 REQ71BW1 50-400/230 8.1 11.5 16 41.1 5.3 0.065 0.6 0.125 0.9 FDEQ71 REQ71BW1 50-400/230 6.8 11.5 16 41.1 4.2 0.065 0.6 0.125 0.9 Max. 50Hz-253V Min. 50Hz-207V Max. 50Hz-440/253V Min. 50Hz-360/207V 1 3 3TW26599-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below orabove listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://eu.extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on the document title of your choice. 6 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 3 Electrical data REQ100B Unit combination Indoor unit Outdoor unit 1 3 Hz-Volts Power supply Voltage range Compressor LRA RLA MCA TOCA MFA 23.8 34.8 40 98.5 25.3 34.5 40 23.2 34.8 OFM IFM kW FLA kW FLA 17.6 0.090 0.8 0.090 1.0 98.5 19.0 0.090 0.8 0.130 0.7 40 98.5 17.1 0.090 0.8 0.135 1.0 FCQ100 REQ100BV3 50-230 FHQ100 REQ100BV3 50-230 FBQ100 REQ100BV3 50-230 FDEQ100 REQ100BV3 50-230 24.2 34.8 40 98.5 17.9 0.090 0.8 0.135 1.0 FCQ100 REQ100BW1 50-400/230 9.2 11.8 16 48.2 5.9 0.090 0.8 0.090 1.0 FHQ100 REQ100BW1 50-400/230 9.4 11.5 16 48.2 6.3 0.090 0.8 0.130 0.7 FBQ100 REQ100BW1 50-400/230 8.9 11.8 16 48.2 5.7 0.090 0.8 0.135 1.0 FDEQ100 REQ100BW1 50-400/230 9.6 11.8 16 48.2 6.2 0.090 0.8 0.135 1.0 Max. 50Hz-253V Min. 50Hz-207V Max. 50Hz-440/253V Min. 50Hz-360/207V 3TW26619-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW 7 : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below orabove listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://eu.extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on the document title of your choice. • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 3 Electrical data 3 REQ125B Unit combination Indoor unit Outdoor unit FCQ125 FHQ125 Hz-Volts REQ125BW1 Power supply Voltage range 50-400/230 REQ125BW1 50-400/230 MCA TOCA MFA 12.4 15.3 20 Compressor LRA RLA 63 OFM IFM kW FLA kW FLA 8.1 0.065 + 0.085 0.6 + 0.7 0.09 1.0 0.6 + 0.7 0.13 0.7 12.3 15.0 20 63 8.2 0.065 + 0.085 Max. 50Hz-440/253V Min. 50Hz-360/207V 1 3 FBQ125 REQ125BW1 50-400/230 12.2 15.7 20 63 7.6 0.065 + 0.085 0.6 + 0.7 0.225 1.4 FDEQ125 REQ125BW1 50-400/230 12.6 15.7 20 63 7.9 0.065 + 0.085 0.6 + 0.7 0.225 1.4 3TW26639-9 MCA TOCA MFA LRA RLA OFM IFM FLA kW : : : : : : : : : SYMBOLS Min. Circuit Amps Total Over Current Amps Max. Fuse Amps (see note 7) Locked Rotor Amps Rated Load Amps Outdoor Fan Motor Indoor Fan Motor Full Load Amps Rated motor output • Split Sky Air • Outdoor Units NOTES 1. RLA is based on the following conditions: Indoor temp.: 27°CDB/19.5°CWB Outdoor temp. : 35°CDB 2. TOCA means the total value of each OC set 3. Voltage range Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below orabove listed operation range limits 4. Maximum allowable voltage unbalance between phases is 2%. 5. MCA/MFA MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA (next lower standard fuse rating Min. 16A) 6. Select wire size based on the larger value of MCA or TOCA 7. Instead of fuse, use circuit breaker 8. For more details concerning conditional connections, see http://eu.extranet.daikineurope.com, select ’’E-Data Books’’. Finally, click on the document title of your choice. 8 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 4 Safety device settings REQ71∼ 125B 1 4 Model Safety device REQ71BV3 REQ100BV3 REQ71BW1 REQ100BW1 Off 135 ±5°C Fan motor thermal protector HPS LPS Max discharge temperature Overcurrent relay REQ125BW1 On 95 ±15°C +0 0,10 Mpa +0,15 - 0,15 Mpa Off 4,15 On 3.2 +0,02 0,02 Off -0.03 - Mpa On 0.05 +0,03 - 0,03 Mpa By thermistor and software control By overcurrent sensor and software control 4TW26321-2B 9 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 5 Options 3 REQ71∼125B Name of option Central drain plug Kit name REQ71B REQ100B REQ125B KKPJ5F180 4TW26599-1 • Split Sky Air • Outdoor Units 1 5 10 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-1 Cooling capacity tables FHQ71-125B + REQ71-100BV3 REQ71-125BW1 1 6 Cooling capacity table Indoor Outdoor EWB (°C) Outdoor temp. (°CDB) EDB (°C) TC 20 SHC PI TC 25 SHC PI TC 32 SHC PI TC 35 SHC PI TC 40 SHC PI TC 46 SHC PI 3TW26592-3 SYMBOLS AFR: BF: EWB: EDB: DB*: TC: SHC: PI: NOTES Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Dry bulb temp. Total cooling/heating capacity Sensible heating capacity Power input (comp.+indoor+outdoor fan motor) 3 (m /min) (°CWB) (°CDB) (°CDB) (kW) (kW) (kW) Caution: TC and SHC are shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference :0m 6. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FHQ 17 0.1 24 0.14 30 0.13 7. Add the following corrections to power input of each model. Model 71 100 125 11 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FHQ 0.05 0 0.07 0 0 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-1 Cooling capacity tables 3 FCQ71-125B + REQ71-100BV3 REQ71-125BW1 Cooling capacity table Indoor Outdoor EWB (°C) 1 Outdoor temp. (°CDB) EDB (°C) TC 20 SHC PI TC 25 SHC PI 32 SHC TC PI TC 35 SHC PI TC 40 SHC PI TC 46 SHC PI 6 3TW26592-1 SYMBOLS AFR: BF: EWB: EDB: DB*: TC: SHC: PI: NOTES Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Dry bulb temp. Total cooling/heating capacity Sensible heating capacity Power input (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 3 (m /min) (°CWB) (°CDB) (°CDB) (kW) (kW) (kW) 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference :0m 6. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FCQ 18 0.1 28 0.16 31 0.07 7. Add the following corrections to power input of each model. Model 71 100 125 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FCQ 0.06 0 0.27 0 0 12 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-1 Cooling capacity tables FBQ71-125B + REQ71-100BV3 REQ71-125BW1 1 6 Cooling capacity table Indoor Outdoor EWB (°C) Outdoor temp. (°CDB) EDB (°C) TC 20 SHC PI TC 25 SHC PI TC 32 SHC PI TC 35 SHC PI TC 40 SHC PI TC 46 SHC PI 3TW26592-2 SYMBOLS AFR: BF: EWB: EDB: DB*: TC: SHC: PI: NOTES Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Dry bulb temp. Total cooling/heating capacity Sensible heating capacity Power input (comp.+indoor+outdoor fan motor) 3 (m /min) (°CWB) (°CDB) (°CDB) (kW) (kW) (kW) Caution: TC and SHC are shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference :0m 6. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FBQ 19 0.11 27 0.2 35 0.14 7. Add the following corrections to power input of each model. Model 71 100 125 13 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FBQ 0.11 0 0.19 0 0 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-1 Cooling capacity tables 3 FDEQ71-125B + REQ71-100BV3 REQ71-125BW1 Cooling capacity table Indoor Outdoor EWB (°C) 1 Outdoor temp. (°CDB) EDB (°C) TC 20 SHC PI TC 25 SHC PI 32 SHC TC PI TC 35 SHC PI TC 40 SHC PI TC 46 SHC PI 6 3TW26592-4 SYMBOLS AFR: BF: EWB: EDB: DB*: TC: SHC: PI: NOTES Air flow rate Bypass factor Entering wet bulb temp. Entering dry bulb temp. Dry bulb temp. Total cooling/heating capacity Sensible heating capacity Power input (comp.+indoor+outdoor fan motor) Caution: TC and SHC are shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 3 (m /min) (°CWB) (°CDB) (°CDB) (kW) (kW) (kW) 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. SHC is based on each EWB and EDB SHC* = SHC correction for other dry bulb SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860 Add SHC* to SHC if SHC > TC, then TC equal SHC 4. Direct interpolation is permissible. Do not extrapolate. 5. Capacities are based on following conditions: Corresponding refrigerant piping length : 7.5 m Level difference :0m 6. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FDEQ 19 0.11 27 0.2 35 0.14 7. Add the following corrections to power input of each model. Model 71 100 125 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FDEQ 0.11 0 0.04 0 0 14 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-2 Heating capacity tables FHQ71-125B + REQ71-100BV3 REQ71-125BW1 1 6 Heating capacity table Outdoor Indoor EDB (°C) outdoor temperature (°CWB) -10 TC -5 PI TC 0 PI TC 6 PI 10 TC PI TC 15 PI TC PI 3TW26592-7 SYMBOLS AFR: EDB: WB: TC: PI: NOTES Air flow rate Entering dry bulb temp. Wet bulb temperature Total cooling/heating capacity Power input (comp.+indoor+outdoor fan motor) (m3/min) (°CDB) (°CWB) (kW) (kW) Caution: TC is shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: * outdoor air : 85 % RH. however, the condition on nominal capacity is 7° CDB/6° CWB * Corresponding refrigerant piping length : 7.5 m Level difference :0m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FHQ 17 0.1 24 0.14 30 0.13 6. Add the following corrections to power input of each model. Model 71 100 125 15 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FHQ 0.05 0 0.12 0 0 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-2 Heating capacity tables 3 FCQ71-125B + REQ71-100BV3 REQ71-125BW1 Heating capacity table Outdoor Indoor EDB (°C) 1 outdoor temperature (°CWB) -10 TC -5 PI TC 0 PI TC 6 PI 10 TC PI TC 15 PI TC PI 6 3TW26592-5 SYMBOLS AFR: EDB: WB: TC: PI: NOTES Air flow rate Entering dry bulb temp. Wet bulb temperature Total cooling/heating capacity Power input (comp.+indoor+outdoor fan motor) (m3/min) (°CDB) (°CWB) (kW) (kW) Caution: TC is shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: * outdoor air : 85 % RH. however, the condition on nominal capacity is 7° CDB/6° CWB * Corresponding refrigerant piping length : 7.5 m Level difference :0m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FCQ 18 0.1 28 0.16 31 0.07 6. Add the following corrections to power input of each model. Model 71 100 125 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FCQ 0.06 0 0.09 0 0 16 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-2 Heating capacity tables FBQ71-125B + REQ71-100BV3 REQ71-125BW1 1 6 Heating capacity table Outdoor Indoor EDB (°C) outdoor temperature (°CWB) -10 TC -5 PI TC 0 PI TC 6 PI 10 TC PI TC 15 PI TC PI 3TW26592-6 SYMBOLS AFR: EDB: WB: TC: PI: NOTES Air flow rate Entering dry bulb temp. Wet bulb temperature Total cooling/heating capacity Power input (comp.+indoor+outdoor fan motor) (m3/min) (°CDB) (°CWB) (kW) (kW) Caution: TC is shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: * outdoor air : 85 % RH. however, the condition on nominal capacity is 7° CDB/6° CWB * Corresponding refrigerant piping length : 7.5 m Level difference :0m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FBQ 19 0.11 27 0.2 35 0.14 6. Add the following corrections to power input of each model. Model 71 100 125 17 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FBQ 0 0 0.04 0 0 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-2 Heating capacity tables 3 FDEQ71-125B + REQ71-100BV3 REQ71-125BW1 Heating capacity table Outdoor Indoor EDB (°C) 1 outdoor temperature (°CWB) -10 TC -5 PI TC 0 PI TC 6 PI 10 TC PI TC 15 PI TC PI 6 3TW26592-8 SYMBOLS AFR: EDB: WB: TC: PI: NOTES Air flow rate Entering dry bulb temp. Wet bulb temperature Total cooling/heating capacity Power input (comp.+indoor+outdoor fan motor) (m3/min) (°CDB) (°CWB) (kW) (kW) Caution: TC is shown by kW V3: 230 V [50 Hz] W1: 400 V [50 Hz] 1. Ratings shown are net capacities. Influence of fan motor heat is included. 2. Shows nominal capacities 3. Capacities are based on following conditions: * outdoor air : 85 % RH. however, the condition on nominal capacity is 7° CDB/6° CWB * Corresponding refrigerant piping length : 7.5 m Level difference :0m 4. Direct interpolation is permissible. Do not extrapolate. 5. Air flow rate and BF are tabulated below. Model 71 100 125 AFR BF AFR BF AFR BF FDEQ 19 0.11 27 0.2 35 0.14 6. Add the following corrections to power input of each model. Model 71 100 125 • Split Sky Air • Outdoor Units Supply V3 W1 V3 W1 W1 FDEQ 0 0 0.04 0 0 18 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 6 Capacity tables 6-2 Heating capacity tables RR/RQ/REQ71∼ 125B Capacity in function of field piping length for non-inverter 1 6 Capacity (%) Field piping length (m) Cooling Heating 19 • Split Sky Air • Outdoor Units 3TW26322-15 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 7 Dimensional drawing & centre of gravity 7-1 Dimensional drawing unit (mm) REQ71B Hole for anchor bolt 4-M12 1 2 3 4 5 6 7 8 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 3 1 7 3TW26324-1 unit (mm) REQ100B Hole for anchor bolt 4-M12 1 2 3 4 5 6 7 8 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 3TW26344-1 • Split Sky Air • Outdoor Units 20 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 7 Dimensional drawing & centre of gravity 7-1 Dimensional drawing unit (mm) REQ125B 1 2 3 4 5 6 7 8 Hole for anchor bolt 4-M12 1 7 Gas pipe connection J15.9 flare Liquid pipe connection - J9.5 flare Service port (in the unit) Grounding terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake (knock hole J34) Control wiring intake (knock hole J27) Drain outlet 3TW26364-1 21 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 7 Dimensional drawing & centre of gravity 7-2 Centre of gravity 3 REQ71B 1 7 Model REQ71B A 267 3TW26329-5C REQ100B Model REQ100B A 390 3TW26349-5C • Split Sky Air • Outdoor Units 22 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 7 Dimensional drawing & centre of gravity 7-2 Centre of gravity REQ125B 1 7 Model REQ125B A 390 3TW26369-5C 23 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 8 Piping diagram 3 REQ71∼125B (Pair) Solenoid valve Electronic expansion valve One way valve One way valve 1 Filter 8 Heat exchanger Filter One way valve One way valve Service port 5/16″ Strainer Receiver Capillary tube Heat exchanger One way valve 4-way valve Filter Low pressure switch High pressure switch Muffler Field piping J9.5 C122OT-O Service port 5/16″ Filter Field piping J15.9 C122OT-O Compressor Indoor unit Stop valve (with service port 1/4 ″ flare) Outdoor unit O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe • Split Sky Air • Outdoor Units Heating Cooling 3TW26325-1 24 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 9 Wiring diagram 9-1 Wiring diagram REQ71-100BV3 Power supply 1∼50Hz 230V 1 9 A1P BS1 C1R C3R DS1 E1HC F1U HAP K1M K1R K2R K3R K4R K5R,K6R,K7R M1C M1F PC Q1DI Q1M R1T R2T R3T RC S1PH S1LP SD T1A TC X1M,X2M Y1E Y1S Y2S CT Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) Capacitor (M1C) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Motor compressor Motor fan Power circuit Earth leakage breaker (30mA) Thermo switch (M1F) Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer Indoor Outdoor ON OFF Switch box (Outdoor) Position of compressor terminal Note: Wire entrance Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow 2TW26326-1B REQ71-100BW1 Switch box (Outdoor) Indoor Outdoor Power supply 3N∼50Hz 400V ON Note: OFF Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Position of compressor terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow A1P BS1 C1 DS1 E1HC F1U, F2U HAP K1M K1R 25 Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Magnetic relay (K1M) Wire entrance K2R K3R K4R K5R,K6R,K7R M1C M1F PC Q1DI Q1M Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Motor compressor Motor fan Power circuit Earth leakage breaker (30mA) Thermo switch (M1F) Q1RP R1T R2T R3T RC S1HP S1LP SD T1A Phase reverse circuit Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) Pressure switch (low) Safety devices input Current transformer • Split Sky Air • Outdoor Units TC X1M,X2M Y1E Y1S Y2S CT Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer 2TW26336-1B • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 9 Wiring diagram 9-1 Wiring diagram 3 REQ125BW1 Switch box (Outdoor) Indoor 1 9 Outdoor Power supply 3N∼50Hz 400V ON OFF Note: Confirm the method of setting the DIP switch (DS1) by service manual when the unit is shipped by factory all switches are set to be off. g Field wiring D : Terminal F : Connector b : Protective earth (screw) L : Live N : Neutral : Terminal Colours BLK: Black/ BLU: Blue/ WHT: White/ RED: Red/ ORG: Orange/ YLW:Yellow A1P BS1 C1 C2 DS1 E1HC F1U, F2U HAP K1M Printed circuit board Push button (forced defrost-pump down) Capacitor (M1F) Capacitor (M2F) DIP switch Crankcase heater Fuse (T6.3/250V) Light emitting diode (service monitor green) Magnetic contactor (M1C) Position of compressor terminal Wire entrance K1R K2R K3R K4R K5R,K6R,K7R K8R,K9R,K10R M1C M1F, M2F PC Magnetic relay (K1M) Magnetic relay (Y2S) Magnetic relay (E1HC) Magnetic relay (Y1S) Magnetic relay (M1F) Magnetic relay (M2F) Motor compressor Motor fan Power circuit Q1D Q1M Q2M Q1RP R1T R2T R3T RC S1PH Earth leakage breaker (30mA) Thermo switch (M1F) Thermo switch (M2F) Phase reverse circuit Thermistor (air) Thermistor (coil) Thermistor (discharge pipe) Signal receiver circuit Pressure switch (high) • Split Sky Air • Outdoor Units S1LP SD T1A TC X1M,X2M Y1E Y1S Y2S CT Pressure switch (low) Safety devices input Current transformer Signal transmission circuit Terminal strip Expansion valve (electronic type) 4-way valve Solenoid valve Current transformer 2TW26366-1B 26 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 9 Wiring diagram 9-2 External connection diagram REQ71∼125B 1 Field wire 9 Symbol explication I II III M S 1 2 3 = = = = = = = = Pair Twin Triple Master Slave Earth leak detector Fuse Remote control 4TW26329-7 27 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 10 Sound data 10 - 1 Sound pressure spectrum Sound pressure level (dB) 1 10 3TW26597-2 Octave band center frequency (Hz) 3TW26597-1 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ71B in cooling mode 1 2 3 Measuring location (discharge side) 4 5 3TW26617-2 Octave band center frequency (Hz) Octave band center frequency (Hz) NOTES NOTES 4 5 Measuring location (discharge side) Sound pressure level [dB(A)] 3TW26617-1 1 2 3 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ71B in heating mode REQ100B - Heating REQ100B - Cooling Sound pressure level [dB(A)] 4 5 Octave band center frequency (Hz) NOTES NOTES 1 2 3 3 REQ71B - Heating Sound pressure level (dB) REQ71B - Cooling Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ100B in cooling mode 1 2 3 Measuring location (discharge side) • Split Sky Air • Outdoor Units 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ100B in heating mode Measuring location (discharge side) 28 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 10 Sound data 10 - 1 Sound pressure spectrum REQ125B - Heating 10 Sound pressure level [dB(A)] 1 Sound pressure level [dB(A)] REQ125B - Cooling 3TW26637-1 3TW26637-2 Octave band center frequency (Hz) NOTES 1 2 3 4 5 29 Octave band center frequency (Hz) NOTES Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ125B in cooling mode 1 2 3 Measuring location (discharge side) • Split Sky Air • Outdoor Units 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ125B in heating mode Measuring location (discharge side) • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 10 Sound data 10 - 2 Sound power spectrum Sound pressure level [dB(A)] 3TW26597-3 1 10 3TW26617-3 Octave band center frequency (Hz) NOTES 1 2 3 4 5 3 REQ100B - Cooling Sound pressure level [dB(A)] REQ71B - Cooling Octave band center frequency (Hz) NOTES Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ71B in cooling mode 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ100B in cooling mode Sound pressure level [dB(A)] REQ125B - Cooling 3TW26637-3 Octave band center frequency (Hz) NOTES 1 2 3 4 5 Data is valid at free field condition Data is valid at nominal operation condition dB(A) = A-weighted sound pressure level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa Curve for REQ125B in cooling mode • Split Sky Air • Outdoor Units 30 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 11 Installation 11 - 1 Installation method REQ71∼ 125B 1 Oil trap Indoor unit 11 Oil trap Outdoor unit Liquid piping Install trap at each difference in eight of 15m Gas piping NOTE: Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and causing liquid compression phenomenon, or cases of deterioration of oil return, it well be necessary to provide a trap at an appropriate place in the riser gas piping. A trap is not necessary when the outdoor unit is installed in a higher position than the indoor unit. 4TW25149-8 31 • Split Sky Air • Outdoor Units • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 11 Installation 11 - 2 Service space 3 REQ71∼ 125B A. Non stacked installation Legend Suction side obstacle 1 Discharge side obstacle 11 Left side obstacle Right side obstacle Top side obstacle Obstacle is present In these cases, close the bottom of the installation frame to prevent discharged air from being bypassed. In these cases, only 2 units can be installed. This situation is not allowed. Figures between ( ) indicate the dimensions only for the 100-125 class models. B. Stacked installation 1. Obstacles exist in front of the outlet side 2. Obstacles exist in front of the air inlet Do not stack more than one unit. About 100mm is required as the dimension for laying the upper outdoor unit’s drain pipe. Get the portion A sealed so that air from the outlet does not bypass. C. Multiple-row installation 1. Installation of one unit per row 2. Installing multiple units (2 units or more) in lateral connection per row Relation of dimensions of H, A, and L are shown in the table below. L≤H H<L L A 0 < L ≤ 1/2 H 150 (250) 1/2 H < L 200 (300) Installation impossible 3TW25149-4A • Split Sky Air • Outdoor Units 32 • Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B 12 Operation range REQ71∼125B Model name Cooling 1 REQ71BV3 REQ100BV3 REQ71BW1 REQ100BW1 12 Notes: - Depending on operation and installation conditions, the indoor unit can change over to freeze-up operation (indoor de-icing). - To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the outdoor unit in a location not exposed to wind. • Split Sky Air • Outdoor Units Operation range Allowable range of operation (warming-up) Outdoor temp. (°CWB) Allowable range of operation (pull-down) Operation range Outdoor temp. (°CDB) Heating Indoor temp. (°CWB) 33 REQ125BW1 Indoor temperature (°CDB) 3TW26593-1