Download 1 Features

Transcript
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
1
AQ i E Rny _Uk B S 3r V o a8t o0B i d1- l 4Qt p-Eu •ROS
1
Features
Outdoor units for pair application
•
•
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
•
The sevice valves are hidden inside the casing.
•
Outdoor units are fitted with a scroll compressor, renowned for low
noise and high energy efficiency.
•
A special acryl precoated fin for anti-corrosion treatment on the heat
exchanger ensures greater resistance against severe weather
conditions
1
1
• Split Sky Air • Outdoor Units
The piping connections can be accessed from underneath, front, side
or rear.
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
2
Specifications
2-1 NOMINAL CAPACITY AND
NOMINAL INPUT
For
combination
indoor units +
outdoor units
Nominal
Capacity
Nominal input
For
combination
indoor units +
outdoor units
Nominal
Capacity
Nominal input
For
combination
indoor units +
outdoor units
Nominal
Capacity
Nominal input
For
combination
indoor units +
outdoor units
Nominal
Capacity
Nominal input
For
combination
indoor units +
outdoor units
2-2
Indoor Units
Dimensions
Cooling
Standard
Heating
Standard
Cooling
Standard
Heating
Standard
EER
Cooling
COP
Heating
Energy
Cooling
Labeling
Heating
Directive
Annual energy consumption
Indoor Units
Cooling
Standard
Heating
Standard
Cooling
Standard
Heating
Standard
EER
Cooling
COP
Heating
Energy
Cooling
Labeling
Heating
Directive
Annual energy consumption
Indoor Units
Cooling
Standard
Heating
Standard
Cooling
Standard
Heating
Standard
EER
Cooling
COP
Heating
Energy
Cooling
Labeling
Heating
Directive
Annual energy consumption
Indoor Units
Cooling
Standard
Heating
Standard
Cooling
Standard
Heating
Standard
EER
Cooling
COP
Heating
Energy
Cooling
Labeling
Heating
Directive
Annual energy consumption
Colour
Material
Unit
Packing
Weight
REQ7 1B8W1 B
R EQ100B 8V3B
REQ1 00B8W1B
REQ125B8 W1B
FDEQ71B8V3B
FDEQ71B8V3B
FDEQ100B8V3B
FDEQ100B8V3B
FDEQ125B8V3B
3
1
kW
kW
kW
kW
7.1
8
2.79
2.49
2.54
3.21
E
C
7.1
8
2.68
2.49
2.65
3.21
D
C
9.8
11.2
3.98
3.99
2.46
2.86
E
C
9.8
11.2
3.94
3.96
2.49
2.89
E
D
12.2
14.5
4.67
4.52
2.61
3.21
D
C
kWh
1395
FCQ71B8V3B
7.1
8
2.72
2.85
2.61
2.81
D
1340
FCQ71B8V3B
7.1
8
2.66
2.80
2.67
2.86
D
1990
FCQ100B8V3B
10
11.2
3.83
3.75
2.61
2.99
D
D
1970
FCQ100B8V3B
10
11.2
3.56
3.66
2.81
3.06
C
2335
FCQ 125B8V3B
12.5
14.6
4.66
5.06
2.68
2.89
D
1360
FBQ71B8V3B
7.1
8
2.79
2.49
2.54
3.21
E
C
1330
FBQ71B8V3B
7.1
8
2.68
2.49
2.65
3.21
D
C
1915
FBQ100B8V3B
10
11.2
3.79
3.91
2.64
2.86
D
D
1780
FBQ100B8V3B
10
11.2
3.6
3.87
2.78
2.89
C
D
2330
FBQ125B8V3B
12.5
14.5
4.67
4.52
2.61
3.21
D
C
1395
FHQ71BVV1B
7.1
8
2.7
2.85
2.63
2.81
1340
FHQ71BVV1B
7.1
8
2.65
2.8
2.68
2.86
1780
FHQ100BVV1B
9.8
11.2
3.68
4.01
2.66
2.79
2335
FHQ125BVV1B
12.2
14.5
4.51
5.16
2.71
2.81
D
D
1885
FHQ 100BVV1B
9.8
11.2
3.75
4.13
2.61
2.71
D
E
E
D
1350
1325
1875
1840
2250
R EQ71B8 V3 B
REQ7 1B8W1 B
R EQ100B 8V3B
REQ1 00B8W1B
REQ125B8 W1B
770
900
320
900
980
420
83
87
Daikin W hite
Painted galvanized steel plate
1170
900
320
1300
980
420
102
107
1170
900
320
1300
980
420
100
105
1170
900
320
1300
980
420
108
113
kW
kW
kW
kW
kWh
kW
kW
kW
kW
kWh
kW
kW
kW
kW
kWh
TECHNICAL SPECIFICATIONS
Casing
R EQ71B8 V3 B
Unit
Packed Unit
Height
Width
Depth
Height
Width
Depth
mm
mm
mm
mm
mm
mm
kg
kg
770
900
320
900
980
420
83
87
• Split Sky Air • Outdoor Units
2
2
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
2
Specifications
2-2 TECHNICAL SPECIFICATIONS
Heat
Exchanger
Dimensions
1
2
Tube type
Fin
Fan
Motor
Fan
Motor
Fan
Compressor
Operation
Range
Sound Level
(nominal)
Refr iger ant
Refr iger ant Oil
3
Length
mm
Nr of Rows
Fin Pitch mm
Nr of Passes
Face
m²
Area
Nr of Stages
REQ71B 8V3B
REQ71B8W1B
REQ100 B8V3B
REQ100B8W1B
R EQ125B 8W1B
857
2
2.00
6
0.641
857
2
2.00
6
0.641
857
2
2.00
10
0.980
857
2
2.00
10
0.980
857
2
2.00
10
0.980
34
34
52
52
1
48.0
43.0
1
48.0
43.0
52
Hi-XSS cooling tube
Non-symmetric waffle louvr e
Anti-corrosion treatment (PE)
Direct Dr ive Propeller
Horizontal
1
55.0
50.0
1
55.0
50.0
2
89.0
80.0
1
1
1
P47L11S
1
1
3
3
3
3
Lower
3
65
65
90
90
Type
Tr eatment
Type
Dischar ge direction
Quantity
Air Flow Rate Cooling
(nominal at
Heating
230V)
Motor
Quantity
Model
Position
Speed
Steps
(nominal)
Motor
Output
Position
Speed
Steps
(nominal)
Motor
Output
Quantity
Motor
Model
Type
Motor
Output
Crankcas
e Heater
Cooling
Min
Max
Heating
Min
Max
Cooling
Sound
Power
Sound
Pressure
Type
Char ge
Control
Nr of Circuits
Type
Char ged Volume
m³/min
m³/min
W
W
1
JT90G-P4V1N@S
1
1
1
JT90G-YE
JT125G-P4V1@S
JT125G- YE
Hermetically sealed scroll compressor
2200
3000
3000
85
Upper
3
65
1
JT160G-YE
W
2200
W
33
33
33
33
33
°CDB
°CDB
°CWB
°CWB
dBA
10.0
46.0
-10
15
65.0
10.0
46.0
-10
15
65.0
10.0
46.0
-10
15
70.0
10.0
46.0
- 10
15
70.0
10.0
46.0
-10
15
70.0
dBA
53.0
53.0
57.0
57.0
57.0
kg
2.5
2.5
3.6
3.6
1
1
1
1
1.5
1.5
1.5
1.5
l
• Split Sky Air • Outdoor Units
R-410A
3.6
Expansion valve ( electr onic type)
1
Daphne FVC68D
1.5
3750
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
2
2-2
Specifications
TECHNICAL SPECIFICATIONS
Piping
connections
Liquid ( OD)
Gas
Drain
Piping Length
Quantity
Type
Diameter
(OD)
Quantity
Type
Diameter
(OD)
Quantity
Type
Diameter
(OD)
Minimum
Maximum
Equivalen
t
Chargele
ss
Maximum
Installation
height
difference
Max. internunit level
difference
Heat Insulation
R EQ71B8 V3 B
REQ7 1B8W1 B
R EQ100B 8V3B
REQ1 00B8W1B
REQ125B8 W1B
1
1
1
1
9.52
9.52
1
Flare connection
9.52
9.52
9.52
1
1
1
1
15.9
15.9
15.9
15.9
3
3
mm
26
m
m
m
mm
mm
3
3
26
3
Hole
26
26
26
5
50
70
5
50
70
5
50
70
5
50
70
5
50
70
m
7.5
7.5
7.5
7.5
7.5
m
30.0
30.0
30.0
30.0
30.0
m
0.5
0.5
0.5
0.5
0.5
Item
Quantity
Item
Quantity
Notes
2-3
ELECTRICAL SPECIFICATIONS
Power Supply
Current
Name
Phase
Frequency
Voltage
Voltage range
1
2
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat exchanger temperature
None
Reverse phase pr otector
PC board fuse
Overcurr ent relay (compressor)
Low pressure switch
High pressure switch
Fan motor thermal protector
Declaration of conformity
1
1
1
1
1
Installation manual
1
1
1
1
1
Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details,
please refer to sound level drawings of this chapter.
The sound power level is an absolute value indicating the power which a sound source generates.
Sound values ar e measured in a semi-anechoic r oom.
In case of drain piping for outdoor unit, drain piping kit ( option) is needed.
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35° CDB,
equivalent refriger ant piping : 7.5m, level differ ence : 0m.
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
equivalent refr iger ant piping : 7.5m, level differ ence : 0m
Defrost Method
Defrost Control
Capacity Control Method
Safety Devices
Standard
Accessories
1
Flare connection
15.9
3
Hz
V
Minimum V
Maximum V
Recomended fuses
A
R EQ71B8 V3 B
REQ7 1B8W1 B
R EQ100B 8V3B
REQ1 00B8W1B
REQ125B8 W1B
V3
1
50
230
W1
3N
50
400
W1
3N
50
400
W1
3N
50
400
32
16
V3
1
50
230
-10%
+10%
40
16
20
• Split Sky Air • Outdoor Units
4
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
2
Specifications
2-3 ELECTRICAL SPECIFICATIONS
Wiring
connections
1
2
5
For Power
Supply
Quantity
Remark
For connection Quantity
with indoor
Remark
Power Supply Intake
REQ71B 8V3B
REQ71B8W1B
1
3 wires (earth wire
included)
1
1
5 wir es ( earth wire
included)
1
• Split Sky Air • Outdoor Units
REQ100 B8V3B
REQ100B8W1B
1
1
3 wires (earth wire
5 wires (ear th wire
included)
included)
1
1
4 wires ( earth wire included)
Outdoor unit only
R EQ125B 8W1B
1
5 wir es ( earth wir e
included)
1
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
3
Electrical data
3
REQ71B
Unit combination
Indoor unit
Outdoor unit
Hz-Volts
Power supply
Voltage range
MCA
TOCA
MFA
Compressor
LRA
RLA
OFM
IFM
kW
FLA
kW
FLA
FCQ71
REQ71BV3
50-230
16.6
23.3
32
75.5
12.2
0.065
0.6
0.045
0.7
FHQ71
REQ71BV3
50-230
16.8
23.2
32
75.5
12.5
0.065
0.6
0.062
0.6
FBQ71
REQ71BV3
50-230
17.4
23.5
32
75.5
12.7
0.065
0.6
0.125
0.9
FDEQ71
REQ71BV3
50-230
15.4
23.5
32
75.5
11.1
0.065
0.6
0.125
0.9
FCQ71
REQ71BW1
50-400/230
7.3
11.3
16
41.1
4.8
0.065
0.6
0.045
0.7
FHQ71
REQ71BW1
50-400/230
7.5
11.2
16
41.1
5.0
0.065
0.6
0.062
0.6
FBQ71
REQ71BW1
50-400/230
8.1
11.5
16
41.1
5.3
0.065
0.6
0.125
0.9
FDEQ71
REQ71BW1
50-400/230
6.8
11.5
16
41.1
4.2
0.065
0.6
0.125
0.9
Max. 50Hz-253V
Min. 50Hz-207V
Max. 50Hz-440/253V
Min. 50Hz-360/207V
1
3
3TW26599-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below orabove listed operation
range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://eu.extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
6
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
3
Electrical data
REQ100B
Unit combination
Indoor unit
Outdoor unit
1
3
Hz-Volts
Power supply
Voltage range
Compressor
LRA
RLA
MCA
TOCA
MFA
23.8
34.8
40
98.5
25.3
34.5
40
23.2
34.8
OFM
IFM
kW
FLA
kW
FLA
17.6
0.090
0.8
0.090
1.0
98.5
19.0
0.090
0.8
0.130
0.7
40
98.5
17.1
0.090
0.8
0.135
1.0
FCQ100
REQ100BV3
50-230
FHQ100
REQ100BV3
50-230
FBQ100
REQ100BV3
50-230
FDEQ100
REQ100BV3
50-230
24.2
34.8
40
98.5
17.9
0.090
0.8
0.135
1.0
FCQ100
REQ100BW1
50-400/230
9.2
11.8
16
48.2
5.9
0.090
0.8
0.090
1.0
FHQ100
REQ100BW1
50-400/230
9.4
11.5
16
48.2
6.3
0.090
0.8
0.130
0.7
FBQ100
REQ100BW1
50-400/230
8.9
11.8
16
48.2
5.7
0.090
0.8
0.135
1.0
FDEQ100
REQ100BW1
50-400/230
9.6
11.8
16
48.2
6.2
0.090
0.8
0.135
1.0
Max. 50Hz-253V
Min. 50Hz-207V
Max. 50Hz-440/253V
Min. 50Hz-360/207V
3TW26619-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
7
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below orabove listed operation
range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://eu.extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
3
Electrical data
3
REQ125B
Unit combination
Indoor unit
Outdoor unit
FCQ125
FHQ125
Hz-Volts
REQ125BW1
Power supply
Voltage range
50-400/230
REQ125BW1
50-400/230
MCA
TOCA
MFA
12.4
15.3
20
Compressor
LRA
RLA
63
OFM
IFM
kW
FLA
kW
FLA
8.1
0.065
+
0.085
0.6
+
0.7
0.09
1.0
0.6
+
0.7
0.13
0.7
12.3
15.0
20
63
8.2
0.065
+
0.085
Max. 50Hz-440/253V
Min. 50Hz-360/207V
1
3
FBQ125
REQ125BW1
50-400/230
12.2
15.7
20
63
7.6
0.065
+
0.085
0.6
+
0.7
0.225
1.4
FDEQ125
REQ125BW1
50-400/230
12.6
15.7
20
63
7.9
0.065
+
0.085
0.6
+
0.7
0.225
1.4
3TW26639-9
MCA
TOCA
MFA
LRA
RLA
OFM
IFM
FLA
kW
:
:
:
:
:
:
:
:
:
SYMBOLS
Min. Circuit Amps
Total Over Current Amps
Max. Fuse Amps (see note 7)
Locked Rotor Amps
Rated Load Amps
Outdoor Fan Motor
Indoor Fan Motor
Full Load Amps
Rated motor output
• Split Sky Air • Outdoor Units
NOTES
1. RLA is based on the following conditions:
Indoor temp.: 27°CDB/19.5°CWB
Outdoor temp. : 35°CDB
2. TOCA means the total value of each OC set
3. Voltage range
Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below orabove listed operation
range limits
4. Maximum allowable voltage unbalance between phases is 2%.
5. MCA/MFA
MCA = 1.25 x RLA + all FLA, MFA = < 2.25 x RLA + all FLA
(next lower standard fuse rating Min. 16A)
6. Select wire size based on the larger value of MCA or TOCA
7. Instead of fuse, use circuit breaker
8. For more details concerning conditional connections, see
http://eu.extranet.daikineurope.com, select ’’E-Data Books’’.
Finally, click on the document title of your choice.
8
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
4
Safety device settings
REQ71∼ 125B
1
4
Model
Safety device
REQ71BV3
REQ100BV3
REQ71BW1
REQ100BW1
Off 135 ±5°C
Fan motor thermal protector
HPS
LPS
Max discharge temperature
Overcurrent relay
REQ125BW1
On 95 ±15°C
+0
0,10
Mpa
+0,15
- 0,15
Mpa
Off 4,15 On 3.2
+0,02
0,02
Off -0.03 -
Mpa
On 0.05 +0,03
- 0,03 Mpa
By thermistor and software control
By overcurrent sensor and software control
4TW26321-2B
9
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
5
Options
3
REQ71∼125B
Name of option
Central drain plug
Kit name
REQ71B
REQ100B
REQ125B
KKPJ5F180
4TW26599-1
• Split Sky Air • Outdoor Units
1
5
10
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-1
Cooling capacity tables
FHQ71-125B + REQ71-100BV3
REQ71-125BW1
1
6
Cooling capacity table
Indoor
Outdoor
EWB
(°C)
Outdoor temp. (°CDB)
EDB
(°C)
TC
20
SHC
PI
TC
25
SHC
PI
TC
32
SHC
PI
TC
35
SHC
PI
TC
40
SHC
PI
TC
46
SHC
PI
3TW26592-3
SYMBOLS
AFR:
BF:
EWB:
EDB:
DB*:
TC:
SHC:
PI:
NOTES
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Dry bulb temp.
Total cooling/heating capacity
Sensible heating capacity
Power input
(comp.+indoor+outdoor fan motor)
3
(m /min)
(°CWB)
(°CDB)
(°CDB)
(kW)
(kW)
(kW)
Caution:
TC and SHC are shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. SHC is based on each EWB and EDB
SHC* = SHC correction for other dry bulb
SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860
Add SHC* to SHC if SHC > TC, then TC equal SHC
4. Direct interpolation is permissible.
Do not extrapolate.
5. Capacities are based on following conditions:
Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
6. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FHQ
17
0.1
24
0.14
30
0.13
7. Add the following corrections to power input of each model.
Model
71
100
125
11
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FHQ
0.05
0
0.07
0
0
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-1
Cooling capacity tables
3
FCQ71-125B + REQ71-100BV3
REQ71-125BW1
Cooling capacity table
Indoor
Outdoor
EWB
(°C)
1
Outdoor temp. (°CDB)
EDB
(°C)
TC
20
SHC
PI
TC
25
SHC
PI
32
SHC
TC
PI
TC
35
SHC
PI
TC
40
SHC
PI
TC
46
SHC
PI
6
3TW26592-1
SYMBOLS
AFR:
BF:
EWB:
EDB:
DB*:
TC:
SHC:
PI:
NOTES
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Dry bulb temp.
Total cooling/heating capacity
Sensible heating capacity
Power input
(comp.+indoor+outdoor fan motor)
Caution:
TC and SHC are shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
3
(m /min)
(°CWB)
(°CDB)
(°CDB)
(kW)
(kW)
(kW)
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. SHC is based on each EWB and EDB
SHC* = SHC correction for other dry bulb
SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860
Add SHC* to SHC if SHC > TC, then TC equal SHC
4. Direct interpolation is permissible.
Do not extrapolate.
5. Capacities are based on following conditions:
Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
6. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FCQ
18
0.1
28
0.16
31
0.07
7. Add the following corrections to power input of each model.
Model
71
100
125
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FCQ
0.06
0
0.27
0
0
12
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-1
Cooling capacity tables
FBQ71-125B + REQ71-100BV3
REQ71-125BW1
1
6
Cooling capacity table
Indoor
Outdoor
EWB
(°C)
Outdoor temp. (°CDB)
EDB
(°C)
TC
20
SHC
PI
TC
25
SHC
PI
TC
32
SHC
PI
TC
35
SHC
PI
TC
40
SHC
PI
TC
46
SHC
PI
3TW26592-2
SYMBOLS
AFR:
BF:
EWB:
EDB:
DB*:
TC:
SHC:
PI:
NOTES
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Dry bulb temp.
Total cooling/heating capacity
Sensible heating capacity
Power input
(comp.+indoor+outdoor fan motor)
3
(m /min)
(°CWB)
(°CDB)
(°CDB)
(kW)
(kW)
(kW)
Caution:
TC and SHC are shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. SHC is based on each EWB and EDB
SHC* = SHC correction for other dry bulb
SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860
Add SHC* to SHC if SHC > TC, then TC equal SHC
4. Direct interpolation is permissible.
Do not extrapolate.
5. Capacities are based on following conditions:
Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
6. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FBQ
19
0.11
27
0.2
35
0.14
7. Add the following corrections to power input of each model.
Model
71
100
125
13
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FBQ
0.11
0
0.19
0
0
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-1
Cooling capacity tables
3
FDEQ71-125B + REQ71-100BV3
REQ71-125BW1
Cooling capacity table
Indoor
Outdoor
EWB
(°C)
1
Outdoor temp. (°CDB)
EDB
(°C)
TC
20
SHC
PI
TC
25
SHC
PI
32
SHC
TC
PI
TC
35
SHC
PI
TC
40
SHC
PI
TC
46
SHC
PI
6
3TW26592-4
SYMBOLS
AFR:
BF:
EWB:
EDB:
DB*:
TC:
SHC:
PI:
NOTES
Air flow rate
Bypass factor
Entering wet bulb temp.
Entering dry bulb temp.
Dry bulb temp.
Total cooling/heating capacity
Sensible heating capacity
Power input
(comp.+indoor+outdoor fan motor)
Caution:
TC and SHC are shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
3
(m /min)
(°CWB)
(°CDB)
(°CDB)
(kW)
(kW)
(kW)
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. SHC is based on each EWB and EDB
SHC* = SHC correction for other dry bulb
SHC* = 0.29 x 60 x AFR (m3/min.) x (1−BF) x (DB*−EDB)/860
Add SHC* to SHC if SHC > TC, then TC equal SHC
4. Direct interpolation is permissible.
Do not extrapolate.
5. Capacities are based on following conditions:
Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
6. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FDEQ
19
0.11
27
0.2
35
0.14
7. Add the following corrections to power input of each model.
Model
71
100
125
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FDEQ
0.11
0
0.04
0
0
14
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-2
Heating capacity tables
FHQ71-125B + REQ71-100BV3
REQ71-125BW1
1
6
Heating capacity table
Outdoor
Indoor
EDB
(°C)
outdoor temperature (°CWB)
-10
TC
-5
PI
TC
0
PI
TC
6
PI
10
TC
PI
TC
15
PI
TC
PI
3TW26592-7
SYMBOLS
AFR:
EDB:
WB:
TC:
PI:
NOTES
Air flow rate
Entering dry bulb temp.
Wet bulb temperature
Total cooling/heating capacity
Power input
(comp.+indoor+outdoor fan motor)
(m3/min)
(°CDB)
(°CWB)
(kW)
(kW)
Caution:
TC is shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. Capacities are based on following conditions:
* outdoor air : 85 % RH. however, the condition on nominal capacity
is 7° CDB/6° CWB
* Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
4. Direct interpolation is permissible.
Do not extrapolate.
5. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FHQ
17
0.1
24
0.14
30
0.13
6. Add the following corrections to power input of each model.
Model
71
100
125
15
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FHQ
0.05
0
0.12
0
0
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-2
Heating capacity tables
3
FCQ71-125B + REQ71-100BV3
REQ71-125BW1
Heating capacity table
Outdoor
Indoor
EDB
(°C)
1
outdoor temperature (°CWB)
-10
TC
-5
PI
TC
0
PI
TC
6
PI
10
TC
PI
TC
15
PI
TC
PI
6
3TW26592-5
SYMBOLS
AFR:
EDB:
WB:
TC:
PI:
NOTES
Air flow rate
Entering dry bulb temp.
Wet bulb temperature
Total cooling/heating capacity
Power input
(comp.+indoor+outdoor fan motor)
(m3/min)
(°CDB)
(°CWB)
(kW)
(kW)
Caution:
TC is shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. Capacities are based on following conditions:
* outdoor air : 85 % RH. however, the condition on nominal capacity
is 7° CDB/6° CWB
* Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
4. Direct interpolation is permissible.
Do not extrapolate.
5. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FCQ
18
0.1
28
0.16
31
0.07
6. Add the following corrections to power input of each model.
Model
71
100
125
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FCQ
0.06
0
0.09
0
0
16
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-2
Heating capacity tables
FBQ71-125B + REQ71-100BV3
REQ71-125BW1
1
6
Heating capacity table
Outdoor
Indoor
EDB
(°C)
outdoor temperature (°CWB)
-10
TC
-5
PI
TC
0
PI
TC
6
PI
10
TC
PI
TC
15
PI
TC
PI
3TW26592-6
SYMBOLS
AFR:
EDB:
WB:
TC:
PI:
NOTES
Air flow rate
Entering dry bulb temp.
Wet bulb temperature
Total cooling/heating capacity
Power input
(comp.+indoor+outdoor fan motor)
(m3/min)
(°CDB)
(°CWB)
(kW)
(kW)
Caution:
TC is shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. Capacities are based on following conditions:
* outdoor air : 85 % RH. however, the condition on nominal capacity
is 7° CDB/6° CWB
* Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
4. Direct interpolation is permissible.
Do not extrapolate.
5. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FBQ
19
0.11
27
0.2
35
0.14
6. Add the following corrections to power input of each model.
Model
71
100
125
17
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FBQ
0
0
0.04
0
0
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-2
Heating capacity tables
3
FDEQ71-125B + REQ71-100BV3
REQ71-125BW1
Heating capacity table
Outdoor
Indoor
EDB
(°C)
1
outdoor temperature (°CWB)
-10
TC
-5
PI
TC
0
PI
TC
6
PI
10
TC
PI
TC
15
PI
TC
PI
6
3TW26592-8
SYMBOLS
AFR:
EDB:
WB:
TC:
PI:
NOTES
Air flow rate
Entering dry bulb temp.
Wet bulb temperature
Total cooling/heating capacity
Power input
(comp.+indoor+outdoor fan motor)
(m3/min)
(°CDB)
(°CWB)
(kW)
(kW)
Caution:
TC is shown by kW
V3: 230 V [50 Hz]
W1: 400 V [50 Hz]
1. Ratings shown are net capacities.
Influence of fan motor heat is included.
2.
Shows nominal capacities
3. Capacities are based on following conditions:
* outdoor air : 85 % RH. however, the condition on nominal capacity
is 7° CDB/6° CWB
* Corresponding refrigerant piping length
: 7.5 m
Level difference
:0m
4. Direct interpolation is permissible.
Do not extrapolate.
5. Air flow rate and BF are tabulated below.
Model
71
100
125
AFR
BF
AFR
BF
AFR
BF
FDEQ
19
0.11
27
0.2
35
0.14
6. Add the following corrections to power input of each model.
Model
71
100
125
• Split Sky Air • Outdoor Units
Supply
V3
W1
V3
W1
W1
FDEQ
0
0
0.04
0
0
18
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
6
Capacity tables
6-2
Heating capacity tables
RR/RQ/REQ71∼ 125B
Capacity in function of field piping length for non-inverter
1
6
Capacity (%)
Field piping length (m)
Cooling
Heating
19
• Split Sky Air • Outdoor Units
3TW26322-15
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
7
Dimensional drawing & centre of gravity
7-1
Dimensional drawing
unit (mm)
REQ71B
Hole for anchor bolt
4-M12
1
2
3
4
5
6
7
8
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
3
1
7
3TW26324-1
unit (mm)
REQ100B
Hole for anchor bolt
4-M12
1
2
3
4
5
6
7
8
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
3TW26344-1
• Split Sky Air • Outdoor Units
20
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
7
Dimensional drawing & centre of gravity
7-1
Dimensional drawing
unit (mm)
REQ125B
1
2
3
4
5
6
7
8
Hole for anchor bolt
4-M12
1
7
Gas pipe connection J15.9 flare
Liquid pipe connection - J9.5 flare
Service port (in the unit)
Grounding terminal M5 (in switch box)
Refrigerant piping intake
Power supply wiring intake (knock hole J34)
Control wiring intake (knock hole J27)
Drain outlet
3TW26364-1
21
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
7
Dimensional drawing & centre of gravity
7-2
Centre of gravity
3
REQ71B
1
7
Model
REQ71B
A
267
3TW26329-5C
REQ100B
Model
REQ100B
A
390
3TW26349-5C
• Split Sky Air • Outdoor Units
22
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
7
Dimensional drawing & centre of gravity
7-2
Centre of gravity
REQ125B
1
7
Model
REQ125B
A
390
3TW26369-5C
23
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
8
Piping diagram
3
REQ71∼125B (Pair)
Solenoid valve
Electronic expansion
valve
One way valve
One way valve
1
Filter
8
Heat exchanger
Filter
One way valve
One way valve
Service
port 5/16″
Strainer
Receiver
Capillary tube
Heat exchanger
One way valve
4-way valve
Filter
Low pressure
switch
High pressure
switch
Muffler
Field piping J9.5 C122OT-O
Service
port 5/16″
Filter
Field piping J15.9 C122OT-O
Compressor
Indoor unit
Stop valve
(with service port 1/4 ″ flare)
Outdoor unit
O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe
• Split Sky Air • Outdoor Units
Heating
Cooling
3TW26325-1
24
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
9
Wiring diagram
9-1
Wiring diagram
REQ71-100BV3
Power supply
1∼50Hz
230V
1
9
A1P
BS1
C1R
C3R
DS1
E1HC
F1U
HAP
K1M
K1R
K2R
K3R
K4R
K5R,K6R,K7R
M1C
M1F
PC
Q1DI
Q1M
R1T
R2T
R3T
RC
S1PH
S1LP
SD
T1A
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
Capacitor (M1C)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
Magnetic relay (K1M)
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Thermo switch (M1F)
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
Pressure switch (low)
Safety devices input
Current transformer
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
Indoor
Outdoor
ON
OFF
Switch box
(Outdoor)
Position of
compressor
terminal
Note:
Wire
entrance
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
2TW26326-1B
REQ71-100BW1
Switch box
(Outdoor)
Indoor
Outdoor
Power supply
3N∼50Hz
400V
ON
Note:
OFF
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Position of
compressor
terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
A1P
BS1
C1
DS1
E1HC
F1U, F2U
HAP
K1M
K1R
25
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
Magnetic relay (K1M)
Wire
entrance
K2R
K3R
K4R
K5R,K6R,K7R
M1C
M1F
PC
Q1DI
Q1M
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Motor compressor
Motor fan
Power circuit
Earth leakage breaker (30mA)
Thermo switch (M1F)
Q1RP
R1T
R2T
R3T
RC
S1HP
S1LP
SD
T1A
Phase reverse circuit
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
Pressure switch (low)
Safety devices input
Current transformer
• Split Sky Air • Outdoor Units
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
2TW26336-1B
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
9
Wiring diagram
9-1
Wiring diagram
3
REQ125BW1
Switch box
(Outdoor)
Indoor
1
9
Outdoor
Power supply
3N∼50Hz
400V
ON
OFF
Note:
Confirm the method of setting the DIP switch (DS1) by
service manual when the unit is shipped by factory all
switches are set to be off.
g Field wiring
D : Terminal
F
: Connector
b
: Protective earth (screw)
L
: Live
N
: Neutral
: Terminal
Colours
BLK: Black/ BLU: Blue/ WHT: White/
RED: Red/ ORG: Orange/ YLW:Yellow
A1P
BS1
C1
C2
DS1
E1HC
F1U, F2U
HAP
K1M
Printed circuit board
Push button (forced defrost-pump down)
Capacitor (M1F)
Capacitor (M2F)
DIP switch
Crankcase heater
Fuse (T6.3/250V)
Light emitting diode (service monitor green)
Magnetic contactor (M1C)
Position of
compressor
terminal
Wire
entrance
K1R
K2R
K3R
K4R
K5R,K6R,K7R
K8R,K9R,K10R
M1C
M1F, M2F
PC
Magnetic relay (K1M)
Magnetic relay (Y2S)
Magnetic relay (E1HC)
Magnetic relay (Y1S)
Magnetic relay (M1F)
Magnetic relay (M2F)
Motor compressor
Motor fan
Power circuit
Q1D
Q1M
Q2M
Q1RP
R1T
R2T
R3T
RC
S1PH
Earth leakage breaker (30mA)
Thermo switch (M1F)
Thermo switch (M2F)
Phase reverse circuit
Thermistor (air)
Thermistor (coil)
Thermistor (discharge pipe)
Signal receiver circuit
Pressure switch (high)
• Split Sky Air • Outdoor Units
S1LP
SD
T1A
TC
X1M,X2M
Y1E
Y1S
Y2S
CT
Pressure switch (low)
Safety devices input
Current transformer
Signal transmission circuit
Terminal strip
Expansion valve (electronic type)
4-way valve
Solenoid valve
Current transformer
2TW26366-1B
26
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
9
Wiring diagram
9-2
External connection diagram
REQ71∼125B
1
Field wire
9
Symbol explication
I
II
III
M
S
1
2
3
=
=
=
=
=
=
=
=
Pair
Twin
Triple
Master
Slave
Earth leak detector
Fuse
Remote control
4TW26329-7
27
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
10
Sound data
10 - 1 Sound pressure spectrum
Sound pressure level (dB)
1
10
3TW26597-2
Octave band center frequency (Hz)
3TW26597-1
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ71B in cooling mode
1
2
3
Measuring location
(discharge side)
4
5
3TW26617-2
Octave band center frequency (Hz)
Octave band center frequency (Hz)
NOTES
NOTES
4
5
Measuring location
(discharge side)
Sound pressure level [dB(A)]
3TW26617-1
1
2
3
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ71B in heating mode
REQ100B - Heating
REQ100B - Cooling
Sound pressure level [dB(A)]
4
5
Octave band center frequency (Hz)
NOTES
NOTES
1
2
3
3
REQ71B - Heating
Sound pressure level (dB)
REQ71B - Cooling
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ100B in cooling mode
1
2
3
Measuring location
(discharge side)
• Split Sky Air • Outdoor Units
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ100B in heating mode
Measuring location
(discharge side)
28
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
10
Sound data
10 - 1 Sound pressure spectrum
REQ125B - Heating
10
Sound pressure level [dB(A)]
1
Sound pressure level [dB(A)]
REQ125B - Cooling
3TW26637-1
3TW26637-2
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
29
Octave band center frequency (Hz)
NOTES
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ125B in cooling mode
1
2
3
Measuring location
(discharge side)
• Split Sky Air • Outdoor Units
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale
according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ125B in heating mode
Measuring location
(discharge side)
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
10
Sound data
10 - 2 Sound power spectrum
Sound pressure level [dB(A)]
3TW26597-3
1
10
3TW26617-3
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
3
REQ100B - Cooling
Sound pressure level [dB(A)]
REQ71B - Cooling
Octave band center frequency (Hz)
NOTES
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ71B in cooling mode
1
2
3
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ100B in cooling mode
Sound pressure level [dB(A)]
REQ125B - Cooling
3TW26637-3
Octave band center frequency (Hz)
NOTES
1
2
3
4
5
Data is valid at free field condition
Data is valid at nominal operation condition
dB(A) = A-weighted sound pressure level (A-scale according to IEC)
Reference acoustic pressure 0dB = 20μPa
Curve for REQ125B in cooling mode
• Split Sky Air • Outdoor Units
30
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
11
Installation
11 - 1 Installation method
REQ71∼ 125B
1
Oil trap
Indoor unit
11
Oil trap
Outdoor unit
Liquid piping
Install trap at each difference in eight of 15m
Gas piping
NOTE:
Since there is fear of the oil held inside the riser piping flowing back into the compressor when stopped and causing liquid
compression phenomenon, or cases of deterioration of oil return, it well be necessary to provide a trap at an appropriate
place in the riser gas piping.
A trap is not necessary when the outdoor unit is installed in a higher position than the indoor unit.
4TW25149-8
31
• Split Sky Air • Outdoor Units
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
11
Installation
11 - 2 Service space
3
REQ71∼ 125B
A. Non stacked installation
Legend
Suction side obstacle
1
Discharge side obstacle
11
Left side obstacle
Right side obstacle
Top side obstacle
Obstacle is present
In these cases, close the
bottom of the installation
frame to prevent discharged
air from being bypassed.
In these cases, only 2 units can
be installed.
This situation is not allowed.
Figures between ( ) indicate
the dimensions only for the
100-125 class models.
B. Stacked installation
1. Obstacles exist in front of the outlet side
2. Obstacles exist in front of the air inlet
Do not stack more than one unit.
About 100mm is required as the dimension for laying the upper outdoor unit’s drain pipe.
Get the portion A sealed so that air from the outlet does not bypass.
C. Multiple-row installation
1. Installation of one unit per row
2. Installing multiple units (2 units or more) in
lateral connection per row
Relation of dimensions of H, A, and L are shown in the
table below.
L≤H
H<L
L
A
0 < L ≤ 1/2 H
150 (250)
1/2 H < L
200 (300)
Installation impossible
3TW25149-4A
• Split Sky Air • Outdoor Units
32
• Outdoor Units • R-410A • REQ-B8V3B_REQ-B8W1B
12
Operation range
REQ71∼125B
Model name
Cooling
1
REQ71BV3
REQ100BV3
REQ71BW1
REQ100BW1
12
Notes:
- Depending on operation and installation conditions, the indoor unit can change over to freeze-up
operation (indoor de-icing).
- To reduce the freeze-up operation (indoor de-icing) frequency, it is recommended to install the
outdoor unit in a location not exposed to wind.
• Split Sky Air • Outdoor Units
Operation range
Allowable range of operation
(warming-up)
Outdoor temp. (°CWB)
Allowable range of operation (pull-down)
Operation range
Outdoor temp. (°CDB)
Heating
Indoor temp. (°CWB)
33
REQ125BW1
Indoor temperature (°CDB)
3TW26593-1