PCSAU0773D AIR CONDITIONING SYSTEM HEAT PUMP [50Hz] 360° airflow!! HFC R-410A Line Up for Stores and Offices. CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE OUTDOOR UNIT PRODUCT RANGE Series 50 60 71 100 125 140 CEILING MOUNTED CASSETTE TYPE Page 5 Round Flow Indoor unit FCQ50KVEA FCQ60KVEA FCQ71KVEA Outdoor unit RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A FCQ100KVEA RZQ100KCV4A RZQ100HAY4A FCQ125KVEA RZQ125KCV4A FCQ140KVEA RZQ125HAY4A RZQ140KCV4A RZQ140HAY4A NEW CEILING SUSPENDED TYPE Page 9 Indoor unit FHQ71BVV1B Outdoor unit RZQ71KCV4A NEW WALL MOUNTED TYPE FHQ100BVV1B RZQ100KCV4A RZQ100HAY4A FHQ125BVV1B RZQ125KCV4A FHQ140CAVEA RZQ125HAY4A RZQ140KCV4A RZQ140HAY4A NEW Page 11 Controllers Page 15-16 Specifications Page 20-21 Options Page 22-23 Dimensions Page 24-28 Indoor unit FAQ71CVEA Outdoor unit RZQ71KCV4A RZQ100HAY4A Page 13 RZQ50KBV4A RZQ60KBV4A O U T D O O R 1 FAQ100CVEA RZQ100KCV4A RZQ71KCV4A U N I T RZQ100KCV4A RZQ100HAY4A RZQ125KCV4A RZQ125HAY4A O U T D O O R RZQ140KCV4A RZQ140HAY4A U N I T 2 HFC R-410A Line Up for Stores and Offices. CEILING MOUNTED CASSETTE TYPE CEILING SUSPENDED TYPE WALL MOUNTED TYPE OUTDOOR UNIT PRODUCT RANGE Series 50 60 71 100 125 140 CEILING MOUNTED CASSETTE TYPE Page 5 Round Flow Indoor unit FCQ50KVEA FCQ60KVEA FCQ71KVEA Outdoor unit RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A FCQ100KVEA RZQ100KCV4A RZQ100HAY4A FCQ125KVEA RZQ125KCV4A FCQ140KVEA RZQ125HAY4A RZQ140KCV4A RZQ140HAY4A NEW CEILING SUSPENDED TYPE Page 9 Indoor unit FHQ71BVV1B Outdoor unit RZQ71KCV4A NEW WALL MOUNTED TYPE FHQ100BVV1B RZQ100KCV4A RZQ100HAY4A FHQ125BVV1B RZQ125KCV4A FHQ140CAVEA RZQ125HAY4A RZQ140KCV4A RZQ140HAY4A NEW Page 11 Controllers Page 15-16 Specifications Page 20-21 Options Page 22-23 Dimensions Page 24-28 Indoor unit FAQ71CVEA Outdoor unit RZQ71KCV4A RZQ100HAY4A Page 13 RZQ50KBV4A RZQ60KBV4A O U T D O O R 1 FAQ100CVEA RZQ100KCV4A RZQ71KCV4A U N I T RZQ100KCV4A RZQ100HAY4A RZQ125KCV4A RZQ125HAY4A O U T D O O R RZQ140KCV4A RZQ140HAY4A U N I T 2 Features and Benefits of DAIKIN's Round Flow cassette Comfortable airflow 360˚ airflow with improved temperature distribution. 4-way flow type 4-way flow leaves areas that cannot be covered. Round Flow type 360° airflow realises uniform airflow distribution. Comfortable Inverter performs variable control of frequency, which determines air conditioner’s power performance. At startup, full power is used to achieve the set temperature quickly. Then, the capacity is adjusted according to the outdoor temperature changes and subtle indoor load changes to achieve fine capacity control resulting in a more stable room temperature. Non-inverter Running current Cooling operation Temp Inverter Starting current Time Current Non-inverter type air conditioners must be switched on and off repeatedly, causing large fluctuations of the room temperature. Soft starter is unnecessary, making electrical installation work much simpler. Current Enhanced comfort with Inverter Running current Set temp Small temp. difference Cools a room in less time Time Inverter power control Non-inverter type air conditioner Time At startup, inverter raises frequency smoothly, eliminating the starting current spike. Compact Compact and lightweight 50 / 60KB, 71KC 100 / 125 / 140KC 100 / 125 / 140HA Height(mm) 1,170 Width(mm) 900 Depth(mm) 320 Weight (kg) 3 770 68 98 1,345 1,170 mm 108 RZQ100KC-140KC SkyAir Range "Nav Ease" Wired Remote Controller Clear Display NEW Simple operation Dot matrix display Large buttons and arrow keys Backlight display Guide on display Energy saving Convenience NEW Setpoint range set Weekly schedule NEW Setpoint auto reset Multilingual display Off timer (programmed) Wired Remote Controller BRC1E62 Energy Efficient Complies with MEPS COP What is COP 3.70 3.40 3.66 3.11 COP is equal to capacity (kW) divided by power consumption (kW), and the larger the COP value, the higher the energy efficiency, enabling cooling and heating with less electricity and increasing the energy saving performance. 3.33 3.00 Heating Cooling 1 2 2 Heating Cooling 1 2 Heating Cooling 1 2 Heating 1 Cooling Heating 2 Cooling 1 2 3 (Coefficient of Performance) 1 2 3.57 3.81 Heating 4.02 3.84 1 4.26 3.94 Cooling 4 FCQ50KVEA FCQ60KVEA FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24.0°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) Quiet operation Night quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Reducing noise will reduce capacity slightly. 3 Sound level (dB(A)) Rated4 Night Quiet Mode RZQ50/60KB 48 RZQ71KC 48 44 RZQ100KC/100HA 49 45 RZQ125KC/125HA 50 45 RZQ140KC/140HA 50 46 Note : 3Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 4 Value when cooling. Value will differ when heating. 4 • • • • • • 5 *1 Hot start (after defrost) Two selectable temperature-sensors High ceiling application Programme "Dry" Draft prevention function (heating) Switchable fan speed (2 step) Swing pattern selection Auto swing • • *1 Applicable when wired remote controller is used *2 For the outdoor units Setpoint auto reset Setpoint range set Weekly schedule timer Off timer (programmed) *2 *1 *1 *1 *1 • • • *2 Filter sign • • *2 Emergency operation Low gas pressure detection Ceiling soiling prevention • • • • • • • • • • • • Anti corrosion treated heat exchangers Fresh air intake kit Control features High-efficiency filter DIII-NET communication standard Interlock control Central remote control Work & Servicing Auto-cooling/heating change-over Control by 2 remote controllers Group control by 1 remote controller External command control Auto-restart Self-diagnosis function Cleanliness Pre charged for up to 30 m Drain pump mechanism Remote controller Silver ion anti-bacterial drain pan Comfort Anti-bacterial air filter Night quiet operation Year-round cooling applicable CEILING MOUNTED CASSETTE TYPE Round Flow Uniform 360° airflow cassette air conditioner is setting tomorrow's standards. Heat pump FCQ50K/60K/71K/100K/125K/140K Accessory required for indoor unit Wired LCD remote controller "Nav Ease" Note: Remote controller cable not included. Cables must be procured locally. BRC1E62 Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. BRC7F632F Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set. Features Options Others *2 Avoids uneven temperature and discomfort caused by drafts. Comfort enhanced by Round Flow! 360 airflow Air movement is gentle with Round Flow With uniform temperature distribution Enhanced Comfort Airflow distribution creates uniform comfort throughout the space 360 airflow can maintain comfort even if air discharge speed is lower. If you raise the set temperature by 1 to 1.5°C in cooling (and lower in heating), and velocity is decreased by 25%, you still obtain the same feeling temperature and comfort. Greater comfort Adapts easily to the installation space. As air flows out from corner outlets, comfort spreads more evenly. Typical flow patterns There are a total of 23 flow patterns. All-round flow 3-way flow L-shaped 2-way flow (E.g., installed in middle of ceiling) (E.g., installed near a wall) (E.g., installed in a corner) Opposite 2-way flow (E.g., installed in a long room) 4-way flow also possible. Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. Operation sound increases when using 2-way or 3-way flow. Grime prevention and bactericidal coating: Makes cleaning easier. External panels are treated with a coating that helps to Treated Untreated repel dirt. surface surface To help prevent dirt sticking to the external panels, they have been coated with a surface treatment. Resists soiling Grimy surface • Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space. Silver ion anti-bacterial drain pan Non-flocking flaps Filter has anti-mould and bactericidal treatment Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Helps prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters. 6 CEILING MOUNTED CASSETTE TYPE Unified square panels Compact body and quiet operation dB(A) Panel size is the same for all models, FCQ50-140K. It is easy to maintain a neat appearance when multiple units are installed in the same room. 950 mm Indoor unit High Low 50K 35 35 35 43 44 44 28 28 28 32 34 36 60K 95 0m 71K Same for all models m 100K 125K 140K Optimal comfort and convenience assured by air discharge modes Note: Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller. Air direction Desired situation Auto-swing 5-levels air direction setting Standard setting Setting to prevent soiling of ceiling* Standard setting to prevent draft. Recommended for shops with light coloured ceilings that must be kept spotless. Auto-swing between 15° and 60° Auto-swing between 25° and 60° Settable to 5 different levels between 15° and 60° Settable to 5 different levels between 25° and 60° Draft prevention (In heating mode) At heating startup and thermo OFF, air discharge is automatically set to a near horizontal 25˚ or 30˚ to prevent direct exposure to cool air drafts. Auto air direction control The air direction is set automatically to the memorised position of the previous air direction. Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. Quick and easy to install Just 256 mm high. Installable in tight ceiling spaces (50K–71K) 256 mm *1 266 mm *2 *1 298 mm high with 100K–140K *2 308 mm high with 100K–140K Easy height adjustment Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height. Note: If the wireless remote control option is installed, a light receptor unit is housed in one of the adjuster pockets. All models can be installed without using lifter because of the light weight. Can be installed in any direction *Closing of the corner discharge outlets is recommended. Suitable for high ceilings Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level. Criteria for ceiling height and number of air discharge outlets (Ceiling height is reference value) Number of air discharge outlets used Standard Ceiling High ceiling height High ceiling Round Flow 50K–71K 100K–140K All round 4-way 3-way 2-way flow flow flow flow All round 4-way 3-way 2-way flow flow flow flow 2.7 m 3.1 m 3.0 m 3.5 m 3.0 m 3.4 m 3.3 m 3.8 m 3.5 m 4.0 m 3.5 m - 3.2 m 3.4 m 3.6 m 4.2 m 3.6 m 3.9 m 4.0 m 4.2 m 4.2 m 4.5 m 4.2 m - Since the orientation of the intake grill can be adjusted after installing, the direction of the intake grill lines can be unified when multiple units are installed. Drain pump is equipped as standard accessory with 850 mm lift. Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting. 850 mm Two selectable temperature-sensors Both indoor unit and wired remote controller (option (BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Hot start (after defrost) Switchable fan speed: High/Low 175 mm Transparent drain socket Connection to a centralised control system is available, no need for option card. Low gas pressure detection 7 Easier to maintain The condition of the drain pan and drain water can be checked by removing the drain plug and intake grille. he en t e! p o Just ke grill inta Drain plug Options required for specific operating environments High-efficiency filter Panel spacer Available in two types: 65% and 90% colorimetry. Use when only minimal space is available between drop ceilings and ceiling slabs. Fresh air intake kit Using this kit, a duct can be fitted to increase the intake of outdoor air. Outside 40mm Panel spacer Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending. Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit. Sealing material of air discharge outlet Sealing material block air discharge openings not used in 2-way or 3-way blow. Branch duct (direct-connection round duct) A round duct can be attached without the need for a chamber. A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole). The units can be installed in the following different ways. Chamber type (without T-joint pipe and fan) Chamber type (with T-joint pipe and without fan) KDDP55B160 KDDP55B160K Flexible duct (procured locally) Flexible duct T-joint pipe (procured locally) T-joint pipe Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Suction chamber Intake duct Connection (procured locally) chamber (duct length: 4 m max.) Direct installation type KDDP55X160 Duct flange (with insulation material) Intake duct (procured locally) Note: Use of options will increase operating sound. 8 CEILING SUSPENDED TYPE Comfortable airflow travels throughout the room Heat pump FHQ71BV / 100BV / 125BV / 140CA FHQ71BV NEW FHQ140CA Accessory required for indoor unit Wired Remote Controller "Nav Ease" BRC1E62 Note: Remote controller cable not included. Cables must be procured locally. Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. 71/100/125BV 140CA BRC7EA63W BRC7GA53 71/100/125BV 140CA Signal receiver unit (Installed type) Wireless remote controller and signal receiver unit are sold as a set. Features 9 Anti corrosion treated heat exchangers • • • • • • • • • Fresh air intake kit Interlock control Central remote control External command control Options Others DIII-NET communication standard *4 Group control by 1 remote controller • Control by 2 remote controllers *4 Auto-cooling/heating change-over *5 Auto-restart • Control features Self-diagnosis function *3 Emergency operation *3 Low gas pressure detection Off timer (programmed) *3 Filter sign Weekly schedule timer *3 Pre charged for up to 30 m Setpoint range set *4 * FHQ71-125BV: 2 step, FHQ140CA: 3 step *2Installable on max. 3.5 m (71-125BV), 4.3 m (140CA) high ceiling *3Applicable when wired remote controller is used *4For the outdoor units *5Option *6FHQ140CA only 1 Work & Servicing Drain pump mechanism Setpoint auto reset • • Night quiet operation *3 Year-round cooling applicable *2 Hot start (after defrost) Two selectable temperature-sensors • High ceiling application *1 Programme "Dry" Switchable fan speed Draft prevention function (heating) Auto swing • • Anti-bacterial air filter Remote controller Cleanliness Comfort *6 *6 *4 New 140 model provides greater capacity for large spaces The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation. High/Middle/Low : 46/42/38 db(A) Sophisticated design Flap neatly closes when not in use. Fresh white colour. Installable on ceilings 4.3 m high Quiet operation dB(A) Indoor unit High Middle Low 71BV 39 42 44 46 ------42 35 37 39 38 100BV 125BV 140CA Uses quiet stream fan and other quiet technologies. (FHQ71-125BV) Turbulent flow is reduced The unit fits more snugly into tight spaces. 30mm 30mm or more or more *Water used in the test-run can now be drained from the air discharge opening rather than from the side as was formerly the case. Drain pump kit (option) can be easily incorporated Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Drain pipe connection can be done inside the unit. refrigerant and drain pipe outlets are at the same opening. 600 mm Drain pump kit (built inside main unit) All wiring and internal servicing can be done from under the unit Simplified piping installation Easy maintenance Louver manually adjusts for straight or wide angle airflow Long-life filter lasts up to 6 months* Installable on ceilings 3.5 m high (FHQ71-125BV) Non-flocking flap Two selectable temperature-sensors Condensation does not easily form on and dirt does not cling to non-flocking flap. Non-flocking flap It is easy to clean. Both indoor unit and wired remote controller (option (BRC1E62) ) contain temperature- sensors. Temperature sensing can be set at the unit or, to further improve comfort level, closer to the target area at the wired remote control. This feature requires initial setting by the installer. *Temperature-sensor on indoor unit must be used when the air conditioner is controlled from another room. **Wireless remote controller does not have a temperature-sensor. Switchable fan speed: High/Low (FHQ71-125BV) Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Quiet stream fan Flexible installation Connection to a centralised control system is available, no need for option card. Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room Straightening plate Installation flexibility for freedom of design 3 fan speeds: High/Middle/Low Comfortable Note : Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. * For dust concentration of 0.15 mg/m3 Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign). Easy-clean, flat surfaces Oil resistant grille Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments. Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments. 10 • • • 11 *1 High fan speed mode Auto airflow rate Switchable fan speed (3 step) Draft prevention function (heating) Auto swing • • *1 Hot start (after defrost) Two selectable temperature-sensors Programme "Dry" • • *1Applicable when wired remote controller is used *2For the outdoor units *3Option Setpoint auto reset Setpoint range set Weekly schedule timer Off timer (programmed) *2 *1 *1 *1 *1 • *3 *2 • *2 • • • • • • • • • • Control features Anti corrosion treated heat exchangers DIII-NET communication standard Interlock control Central remote control External command control Group control by 1 remote controller Work & Servicing Control by 2 remote controllers Auto-cooling/heating change-over Auto-restart Self-diagnosis function NEW Emergency operation Low gas pressure detection Cleanliness Filter sign Pre charged for up to 30 m Remote controller Drain pump mechanism Comfort Mould-proof air filter Night quiet operation Year-round cooling applicable WALL MOUNTED TYPE Compact design and easy installation FA Q 71/100C FAQ71C FAQ100C Accessory required for indoor unit Wired LCD remote controller "Nav Ease" Note: Remote controller cable not included. Cables must be procured locally. BRC1E62 Option Wireless LCD remote controller A signal receiver must be added to the indoor unit. BRC7EB518 Wireless remote controller and signal receiver unit are sold as a set. Signal receiver unit (Installed type) Features Others *2 Easy installing and servicing Compact & Sophisticated design FAQ100 9kg lighter 340 mm 1,200mm 370mm shorter FAQ100BV FAQ100C Height 360mm 340mm Width 1,570mm 1,200mm Depth 200mm 240mm Weight 26kg 17kg 6-direction piping offers greater installation flexibility. Left pipe Back-left pipe Bottom-left pipe Right pipe Back-right pipe Bottom-right pipe Maintenance possible from the front of the unit Flaps close fully when not in use All maintenance tasks can be carried out via front access. During service work, attachment and detachment of parts is easier. Drain pump kit is available as option. Installs onto side of unit. Comfortable Auto swing (up and down) and wide-angle louvers (left and right by hand) facilitate even room temperature Air discharge modes ensure comfortable air distribution across the entire room Height of drain up Refrigerant piping 1,000 mm Wide-angle louvers (adjusted manually) Drain pump kit Drain pump kit can be installed on either left and right side of the air conditioner. Soft material louver bends airflow over a wider area Auto-swing Indoor unit 5-level air direction setting Gettable to 5 different levels Comfort even on the far side of the room Connection to a centralised control system is available, no need for option card. Easy cleaning Removable and washable grille To carry air to the far side of long rooms, extra-high airflow adds 10% more fan speed the "high" setting. Air discharge setting is selected from the remote controller by field setting. Flat panel, easy to wipe dust off Two selectable temperature-sensors Non-flocking flaps Switchable fan speed: High/Middle/Low Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean. Auto airflow rate (When BRC1E62 is used) Programme "Dry" Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. 12 OUTDOOR UNIT Complies with Complies with MEPS MEPS RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Easy installation and maintenance Operation range Pre charged for up to 30 metres 4-direction piping offers greater layout freedom Suited for year-round cooling applications The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work. Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. If the refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. 75 m piping length (Applicable to RZQ100KC–140KC and RZQ100HA–140HA outdoor units) Wide operation range 50 50/60KB Pre charged1 Max. length 100-125KC 100-125HA 71KC 30 m 50 m 30 m (Equivalent length 70m) Max. level difference 40 Separation available Allowed refrigerant piping length and level difference 75 m (Equivalent length 90m) 30 m Facilitates pump down Note : Additional refrigerant charging is required if the refrigerant pipe is longer than the length. Cooling 15.5˚C -5˚C 0 WB Heating DB -15˚C -10 -20 WB Outdoor temp(˚CDB) Outdoor temp(˚CWB) *Pump-down function is available for pre-charged refrigerant amount. Effective gas monitoring reduces the labor required for operation, maintenance, and repairs. Compact and light weight Easy centralised installation with the module oriented design DB 20 10 (Refrigerant recovery function) A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified. Low gas pressure detection function 1 46˚C 30 Height(mm) Width(mm) Depth(mm) Weight(kg) Durability As the bottom frame is subject to corrosion, a corrosion-proof galvarium steel plate is adopted to enhance the durability. Heat exchange fins are provided with anti-corrosion treatment 50/60KB, 71KC 100/125/140KC 100/125/140HA 770 1,170 1,345 900 320 68 98 108 Construction Non-treated fin Aluminium Anti corrosion treated heat exchangers Hydrophilic film Aluminium Corrosion resistant acrylic resin Night time quiet operation function The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Reducing noise will reduce capacity slightly. RZQ71KC 48 44 RZQ100KC/100HA 49 45 RZQ125KC/125HA 50 45 RZQ140KC/140HA 50 46 Note : 1Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 2 Value when cooling. Value will differ when heating. 100 8 hours 50 0 50 Limitation Rated 45 Quiet mode 8:00 12:00 16:00 20:00 Note : 3In case of RZQ125 13 10 hours Power consumption 44 Capacity (%) Night Quiet Mode 48 Load (%) Operation Sound (dB(A)) Rated2 RZQ50/60KB The maximum capacity is maintained within a set level of power consumption, which makes it possible to keep a comfortable and effective demand control. Peak in outdoor temperature 1 Sound level (dB(A)) Demand Control Quiet mode 8:00 0:00 4:00 8:00 12:00 16:00 * Required for KRP58M51 (Option) 20:00Time Technology for energy efficiency The high efficiency compressor to achieve a high COP 1 Compressor equiped with Reluctance DC motor Motor efficiency (%) Daikin DC Inverter models are equipped with the Reluctance DC motor for compressor. The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and reluctance torque*2. This motor can save energy because it generates more power with a smaller electric power than an AC or conventional DC motor. 3 2 Reluctance DC Motor 90 1 Reluctance DC motor 80 Conventional DC motor More than 20% 70 AC motor 60 50 0 30 60 90 120 Rotational speed (rps) Small load Low capacity Large load High capacity Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory. >> Smooth sine wave DC inverter *1. A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet. *2. The torque created by the change in power between the iron and magnet parts. Use of an optimised sine wave smoothes motor rotation, further improving operating efficiency. RZQ50/60KB, RZQ71KC RZQ100/125/140KC, RZQ100/125/140HA >> Swing compressor Energy savings is realised, eliminating the friction and the leakage of refrigerant gas. 2 Sine wave DC inverter Swing bushing Refrigerant gas Piston by incorporated blade and roller. Suction >> The structural scroll Sucked gas is compressed in the scrolling part before the heated motor, so that the Discharge machine compress the non-expanded gas, resulting in high efficiency compression. Smooth Air Inlet Bell Mouth and Aero Spiral Fan With the bent blade edge Scroll section Motor section Without the bent blade edge These two features work to reduce noise. Guides are added to the bell mouth intake to reduce turbulence in the airflow generated by fan suction. The Aero Spiral Fan features fan blades with the bent blade edges, further reducing turbulence. Escaping eddies are sucked in by the bent blade edges, reducing overall turbulence. 3 DC fan motor DC fan motor structure Efficiency improved in all areas compared to AC motors, especially at low speeds. 14 LCD REMOTE CONTROLLER Easy-to-read LCD remote controller allows various system Remote controller options are shown on the page introducing each indoor unit model. Wired Remote Controller NEW "Nav Ease" This simple, contemporary remote controller with fresh white colour matches your interior design. The clear, backlight display with large easy-to-read text makes navigation easy and provides one-touch control over your in-home comfort. BRC1E62 Clear Display Dot matrix display Backlight display A combination of fine dots enables various icons. Large text display is easy to see. Energy saving Auto operation mode NEW Until now only the temperature for one point could be set, but now the new remote controller (BRC1E62) allows the setting of both Cooling and Heating, and with the fan operation, mid-range temperatures are comfortable andoperation is more energy efficient. Setpoint auto reset - Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. - Period selectable from 30min/60min/90min/120min. Restaurant sample Restaurant opened NEW 27°C Temperature is set to 27ºC 2 setpoints Cooling / Heating Full tables at lunchtime 20ºC Heating operation NEW - Saves energy by limiting the min. and max. set temperature. - Avoids excessive heating or cooling. - This function is convenient when the remote controller is installed at a place where any number of people may operate it. 15 26ºC Fan operation Setpoint range set Then is lowered to 24ºC for crowded room 24°C Cooling operation After 30 minutes* Returns to Automatically returns to preset temperature (27ºC) automatically 27°C *Setting possible for after 30, 60, 90, and 120 minutes. Off timer (programmed) - Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. - Period can be preset from 30 to 180 minutes in 10-minute increments. control configurations and control of multiple indoor units. Convenience Weekly schedule NEW - 5 actions per day can be scheduled for each day of the week. - The holiday function will disable schedule timer for the days that have been set as holiday. - 3 independent schedules can be set. (e.g. summer, winter, mid-season) College classroom sample (a summer Monday case) 1) 8:30 ON 2) 10:00 The first period starts and the air conditioner starts the cooling operation. OFF 3) 13:00 In the second period, the classroom is unoccupied and the air conditioner stops. ON ON 4) 15:00 When the third period starts, operation starts again. OFF OFF After the third period, the classroom becomes vacant again and the air conditioner stops. ON OFF Multilingual display Display is available in 11 languages. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish). LCD wireless remote controller The wireless remote controller is supplied in a set with a signal receiver. Signal receiver unit is contained inside decoration panel or indoor unit. Shape of signal receiver unit differs according to the indoor unit. Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type. Signal receiver unit (For ceiling mounted cassette type) Wireless remote controller for each indoor unit type Heat pump CEILING SUSPENDED TYPE 71-125BV WALL MOUNTED TYPE SkyAir shares common control with the Heat Reclaim Ventilator and other Daikin air-conditioning units, thus simplifying interlocking operations. LCD remote controller for SkyAir indoor unit BRC7EA63W BRC7GA53 100CA BRC7F632F Wireless remote controller BRC7F632F CEILING MOUNTED CASSETTE TYPE BRC7EB518 SkyAir Indoor unit Interlocking Interlocking Heat Reclaim Ventilator 16 Simple system provides a diverse assortment of control modes. Control pattern Control by 1 remote controller (Basic system) Control by 2 remote controllers For control from 2 locations such as in room and control room, exits, etc. Group control Control by external command Wired remote controller Wireless remote controller Non-polar, double-core (max. wiring length 500 m) For simultaneous control of up to 16 indoor units. Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. Signal receiver unit installed on indoor unit Not possible (See note 2, 3) Connects 2 wired remote controllers (See note 1) Automatic address setting function Automatic address setting function Signal receiver unit installed on 1 indoor unit Optional wiring adaptor for electrical appendices is necessary Optional wiring adaptor for electrical appendices is necessary Central remote controller (option) Centralised remote control Central remote controller (option) Centralised control of up to 64 indoor groups from remote location up to 1 kilometer away. Optional SkyAir series interface adaptor required (See note 4) Link by remote controller group control. Interlock control with Heat Reclaim Ventilator Optional SkyAir series interface adaptor required (See note 4) Heat Reclaim Ventilator Heat Reclaim Ventilator Can be operated simultaneously or independently by remote controller (set by ventilation mode) Can be operated simultaneously by remote controller (set by ventilation mode) Central remote controller (option) Zone link control by centralised control. Central remote controller (option) Heat Reclaim Ventilator Heat Reclaim Ventilator Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking. Can also be operated independently by remote controller. Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking Note:1.BRC1E62 can connect to BRC1E62 only. 2 .It is not possible to use two wireless remote controllers. 3 .BRC1E62 cannot connect to wireless remote controller. 4 .The ceiling mounted cassette type <Round Flow>, ceiling suspended type(140CA only), and wall mounted type come standard with an interface adaptor for SkyAir series. Easily adaptable to large-scale, high-function, centralised remote control system. Central remote controller DCS302CA61 (Option) Centralised control, with a setting as simple as it is with a standard remote controller, of up to 64 groups (1,024 indoor units) is possible. Interface adaptor for SkyAir series DTA112BA51 (Option) 17 Unified on/off controller DCS301BA61 (Option) Centralised control of on/off by group or all at once for up to 256 indoor units. Schedule timer DST301BA61 (Option) Unified control of weekly schedule for up to 1,024 indoor units. Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time. Enables centralised control via connection to a high-speed, DIII-NET communication system, adopted for the Daikin VRV system. Necessary for interface adaptor for SkyAir series with the central remote control units shown at above. DCS601C51 (Option) With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways. The interface adaptor for the SkyAir series is optional except for the ceiling mounted cassette type <Round Flow>, ceiling suspended type (140CA only), and wall mounted type. Abundance of features that provide comfortable air-conditioning in stores and offices. Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Comfort High-ceiling application Auto-swing Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner. The air flow direction can be fixed at your desited angle by the remote controller. Applicable for ceiling mounted cassette type and ceiling suspended type. You can freely set 2 air discharge settings by remote controller. Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings. (1) Air direction in standard setting Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply. Swing pattern selection (standard, ceiling soiling prevention) (2) Air direction in ceiling soiling prevention setting Two selectable temperature-sensors Draft prevention function (heating) To prevent cold air drafts, automatically adjusts airflow to near horizontal position when heating initially starts or when the thermostat turns off. Switchable fan speed High setting provides maximum reach while low setting minimises drafts. Auto airflow rate Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature. High fan speed mode Applicable for wall mounted type. You can increase fan speed approximately 10% higher than the "high" setting. Programme "Dry" Dehumidification is a microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room. Temperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to the target area is possible to further increase the comfort level. Use the temperature-sensor in the indoor unit when controlling air conditioning from another room. Note: Wireless remote controllers have no temperature-sensor. Hot start (after defrost) Cold air flow is avoided when heating operation starts or when switching to heat after defrosting. Year-round cooling applicable Efficient cooling even in winter when the indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers. Night quiet operation The Automatic night quiet mode will initiate 8 hours after the peak temperature is reached in the daytime, and normal operation will resume 10 hours after that. Remote Controller Setpoint auto reset Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. Setpoint range set Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling. Weekly schedule timer Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature. Off timer (programmed) Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts. Cleanliness Anti-bacterial air filter The Air filter has a anti-bacterial treatment to help prevent the growth of bacteria and mould on it. Silver ion anti-bacterial drain pan Mould-proof drain pan includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging. Mould-proof air filter Sanitary filter has mould-resistant treatment. 18 Note: Some features only available on selected models. See model pages for full list of features applicable to each unit. Work and Servicing Drain pump mechanism Applicable for ceiling mounted cassette type and ceiling suspended type. Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping. Pre charged for up to 30 metres If the refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging. Filter sign The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit. Ceiling soiling prevention function Low gas pressure detection Insufficient gas charging is normally hard to detect. During post-installation trials and regular inspection procedures, the refrigerant level is monitored by a microprocessor to maintain proper gas pressure. Reliability is assured and maintenance and inspection can be carried out more quickly. Emergency operation If there is a malfunction elsewhere in the system, the fan or compressor can still be operated. Self diagnosis function The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate a quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates. Applicable for ceiling mounted cassette type. Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required. Control features Auto-restart If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored. Auto cool/heat change-over (Heat pump only) Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heating accordingly. Control by 2 remote controllers Using 2 remote controllers you can operate the equipment locally or from a remote location. Note: When a wireless remote controller is used, remote control by two remote controllers is not possible. Group control by 1 remote controller You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.) External command control Operation and surveillance is carried out using the contact signal from the operation control box in the building surveillance (security) room. *Required for KRP58M51 (Option) Central remote control An optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 kilometer away. Interlock control Enables interlocking control with external equipment such as Heat Reclaim Ventilator. DIII-NET communication standard Standardly equipped interface enables connection to centralised control system without need of an adaptor. Options High-efficiency filter unit Applicable for ceiling mounted cassette type. Two types are available: 65% and 90% colorimetry. Fresh-air intake kit Applicable for ceiling mounted cassette type. You can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed. Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts should, as required, be procured locally. **Outside Air fan interlocked with air conditioning unit is necessary. Optional PCB(KRP1C63)is required for interlocking. ***It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating noise and may also influence temperature sending. Others Anti corrosion treated heat exchangers To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated Anti corrosion treated heat exchangers (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out. 19 SPECIFICATIONS CEILING MOUNTED CASSETTE TYPE 50 Model Name 100 125 140 100 125 140 Outdoor unit RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A kW kW Cooling1 Heating2 Unit Colour Decoration panel Airflow rate (H/L) (H/L)3 Outdoor unit 71 FCQ50KVEA FCQ60KVEA FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption Indoor unit 60 Indoor unit Sound pressure level Sound power level (H/L)4 Dimensions Unit (HXWXD) Decoration panel Machine Unit weight Decoration panel Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating3 level Night quiet mode Sound power level 4 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW 5.0 (3.2-5.6) 6.0 (3.5-7.0) 1.27 1.41 3 Phase, 415 V, 50 Hz 12.5 13.6 10.0 12.5 13.6 (5.7-14.0) (6.2-15.4) (5.0-11.2) (5.7-14.0) (6.2-15.4) 14.0 16.0 11.2 14.0 16.0 (6.0-16.2) (6.2-18.0) (5.1-12.8) (6.0-16.2) (6.2-18.0) 4.02 4.54 2.94 3.77 4.39 3.83 4.80 3.03 3.83 4.80 ---------White 533/333 550/375 550/375 533/333 550/375 550/375 32/20 33/22.5 33/22.5 32/20 33/22.5 33/22.5 43/32 44/34 44/36 43/32 44/34 44/36 60/50 61/52 61/54 60/50 61/52 61/54 298X840X840 298X840X840 298X840X840 298X840X840 298X840X840 298X840X840 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 24 24 24 24 24 24 5.5 5.5 5.5 5.5 5.5 5.5 14 to 25 15 to 27 White Hermetically sealed scroll type 1.9 2.4 3.1 1.7 2.2 2.9 3.7 3.7 3.7 4.3 4.3 4.3 (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) 49/51 50/52 50/52 49/51 50/52 50/52 45 45 46 45 45 46 65 ----------65 ----------1,170X900X320 1,170X900X320 1,170X900X320 1,345X900X320 1,345X900X320 1,345X900X320 98 98 98 108 108 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 9.5 o/ 15.9 o/ 15.9 o/ 15.9 o/ 15.9 o/ 15.9 o/ 15.9 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 75 (Equivalent length 90) 30 Both liquid and gas piping 1 Phase, 240 V, 50 Hz 7.1 10.0 (3.2-8.0) (5.0-11.2) 8.0 11.2 (3.5-9.0) (5.1-12.8) 1.99 2.94 2.10 3.03 5.8 (3.2-6.0) 7.0 (3.5-8.0) 1.51 1.74 350/225 350/225 350/225 /s m3/min 21/13.5 21/13.5 21/13.5 dB(A) 35/28 35/28 35/28 dB(A) 53/46 53/46 53/46 mm 256X840X840 256X840X840 256X840X840 mm 50X950X950 50X950X950 50X950X950 kg 21 21 21 kg 5.5 5.5 5.5 °CWB °CDB Hermetically sealed swing type 1.7 1.3 1.6 2.75 2.75 2.75 kg (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) dB(A) 48/50 48/50 48/50 44 44 44 dB(A) dB(A) 66 66 66 mm 770X900X320 770X900X320 770X900X320 kg 68 68 68 °CDB °CWB mm o/ 9.5 o/ 9.5 o/ 9.5 mm o/ 15.9 o/ 15.9 o/ 15.9 mm I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 I.Do/ 25XO.Do/ 32 mm o/ 26.0 (Hole) o/ 26.0 (Hole) o/ 26.0 (Hole) 50 m 30 (Equivalent length 70) m kW CEILING SUSPENDED TYPE Model Name 71 100 125 140 100 125 140 Indoor unit FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA FHQ100BVV1B FHQ125BVV1B FHQ140CAVEA Outdoor unit RZQ71KCV4A RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption Indoor unit kW kW Cooling1 Heating2 kW kW Colour Airflow rate (H/M/L) (H/M/L)3 Outdoor unit Sound pressure level Sound power level (H/M/L)4 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Type Compressor Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating3 level Night quiet mode Sound power level Cooling/Heating4 X Dimensions (H WXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation /s m3/min dB(A) dB(A) mm kg °CWB °CDB 5.8 (3.2-8.0) 7.5 (3.5-9.0) 1.77 2.32 283/-/233 17/-/14 39/-/35 55/-/51 195X1,160X680 27 Hermetically sealed swing type 1.7 2.75 kg (Charged for 30 m) dB(A) 48/50 dB(A) 44 dB(A) 66 mm 770X900X320 kg 68 °CDB °CWB mm mm mm mm 50 m (equivalent length 70) m kW 1 Phase, 240 V, 50 Hz 9.2 11.2 (5.0-11.2) (5.7-14.0) 10.5 13.5 (5.1-12.8) (6.0-16.2) 2.93 3.70 3.33 4.35 White 400/-/333 500/-/417 24/-/20 30/-/25 42/-/37 44/-/39 58/-/53 60/-/55 195X1,400X680 195X1,590X680 32 35 13.2 (6.2-15.4) 16.0 (6.2-18.0) 4.40 5.00 Fresh white 567/483/400 34/29/24 46/42/38 64/60/56 235X1,590X690 38 14 to 25 15 to 27 White 3 Phase, 415 V, 50 Hz 13.2 9.2 11.2 (6.2-15.4) (5.0-11.2) (5.7-14.0) 10.5 13.5 16.0 (5.1-12.8) (6.0-16.2) (6.2-18.0) 2.85 3.55 4.33 3.26 4.35 4.93 White Fresh white 567/483/400 400/-/333 500/-/417 34/29/24 24/-/20 30/-/25 42/-/37 44/-/39 46/42/38 58/-/53 60/-/55 64/60/56 195X1,400X680 195X1,590X680 235X1,590X690 38 32 35 Hermetically sealed scroll type 1.9 49/51 65 2.4 3.7 (Charged for 30 m) 50/52 45 67 1,170X900X320 98 3.1 2.3 49/51 46 ------ 65 2.7 4.3 (Charged for 30 m) 50/52 45 67 1,345X900X320 108 2.9 46 ------ -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP20 (External Dia, 26/Internal Dia. 20) o/ 26.0 (Hole) 75 (equivalent length 90) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 4 Numerical values are according to ISO 3741:1999. 20 SPECIFICATIONS WALL MOUNTED TYPE Indoor unit Model Name Outdoor unit Power supply Cooling capacity1 Rated (Min. - Max.) Heating capacity2 Rated (Min. - Max.) Power consumption Indoor unit 71 100 100 FAQ71CVEA FAQ100CVEA FAQ100CVEA RZQ71KCV4A RZQ100KCV4A RZQ100HAY4A 1 Phase, 240 V, 50 Hz kW kW Cooling1 Heating2 Colour Airflow rate (H/M/L) Sound pressure level (H/M/L)3 Sound power level (H/M/L)4 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Colour Outdoor Type Compressor unit Motor output Refrigerant charge (R-410A) Sound pressure Cooling/Heating3 level Night quiet mode Sound power level Cooling/Heating4 Dimensions (HXWXD) Machine weight Cooling Certified Operation range Heating Piping Liquid (Flare) connections Gas (Flare) Drain Indoor unit Outdoor unit Max. interunit piping length Max. installation level difference Heat insulation kW kW /s m3/min dB(A) dB(A) mm kg °CWB °CDB kW kg dB(A) dB(A) dB(A) mm kg °CDB °CWB mm mm mm mm m m 7.1 (3.2-8.0) 8.0 (3.5-9.0) 2.20 2.33 300/267/233 18/16/14 45/42/40 61/58/56 290X1,050X238 13 Hermetically sealed swing type 1.7 2.75 (Charged for 30 m) 48/50 44 66 770X900X320 68 50 (Equivalent length 70 m) 3 Phase, 415 V, 50 Hz 10.0 (5.0-11.2) 11.2 (5.1-12.8) 3.19 3.45 White 14 to 25 15 to 27 Ivory white 3.44 433/383/317 26/23/19 49/45/41 65/62/58 340X1,200X240 17 Hermetically sealed scroll type 1.9 1.7 3.7 (Charged for 30 m) 4.3 (Charged for 30 m) 49/51 45 65 1,170X900X320 1,345X900X320 98 108 -5 to 46 -15 to 15.5 o/ 9.5 o/ 15.9 VP13(External Dia, 18/Internal Dia. 13) o/ 26.0 (Hole) 75 (Equivalent length 90 m) 30 Both liquid and gas piping Note : 1 Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2 Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3 Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions. 4 Numerical values are according to ISO 3741:1999. 21 OPTIONS Indoor unit CEILING MOUNTED CASSETTE TYPE Name of option Remark FCQ50KVEA FCQ60KVEA Decoration panel Sealing material of air discharge outlet Panel spacer Fresh air Chamber type intake kit1 Without the T-joint pipe and fan With the T-joint pipe, without fan Direct installation type 2 Chamber connection kit Insulation kit for high humidity (Colorimetric method 65%) High-efficiency filter (including chamber) (Colorimetric method 90%) Replacement (Colorimetric method 65%) high-efficiency filter (Colorimetric method 90%) Filter chamber Branch duct chamber Wireless type Heat pump Remote controller Wired type3 "Nav Ease" Central remote controller4 Unified ON/OFF controller4 Schedule timer4 Touch Controller4 Adaptor for wiring5 Group control adaptor5 Installation box for adaptor PCB Remote sensor (for indoor temperature) KDTP55K80 KAFP556B80 KAFP557B80 KAFP552B80 KAFP553B80 KDJP55B80 Kit name FCQ71KVEA FCQ100KVEA FCQ125KVEA FCQ140KVEA BYCP125K-W1 KDBH55K160F KDBP55H160FA KDDP55B160 KDDP55B160K KDDP55X160 KKSJ55KA160 KDTP55K160 KAFP556B160 KAFP557B160 KAFP552B160 KAFP553B160 KDDFP55B160 KDJP55B160 BRC7F632F BRC1E62 DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP1C63 KRP4AA53 KRP1H98 KRCS01-4B Note: 1Refer to page 8 for the details. 2 Required for installing high-efficiency filter or ultra long-life filter. 3 Wiring for wired remote controller to be procured locally. 4 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 5 Installation box for adaptor PCB (KRP1H98) is necessary. Round flow type: List of optional parts required to achieve different flow patterns For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. All-round flow 4-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Filter related High-efficiency filter2 3-way flow Panel spacer1 o o o x o Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o x x o o o x o o High-humidity operation kit x o x o x High-efficiency filter2 o o o o x 2-way flow Optional accessory parts Independently installable optional parts Panel/grille related Panel spacer1 Operation control related Wireless remote controller Auxillary function related Fresh air intake kit (Chamber type)1,2 Fresh air intake kit (direct mount) High-humidity operation kit Panel spacer1 o3 o3 o3 x Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o3 o o o o3 o x x o3 o x o High-humidity operation kit High-efficiency filter2 High-humidity operation kit High-efficiency filter2 x o x o x x x x x Branch duct connection Optional accessory parts Independently installable optional parts Branch duct1 1-way branch / unit 3-way flow (Chamber type) 2-way branch / unit 2-way flow (Round duct type) 1-way branch / unit 2-way flow Panel spacer1 o x x Wireless Fresh air intake kit Fresh air intake kit remote controller (Chamber type)1,2 (direct mount) o o o o o o o o4 o4 4 x x x x x x 1 In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position. 3 It is not possible to use panel spacers in a 2-way flow installation. 4 It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. 2 22 OPTIONS Indoor unit CEILING SUSPENDED TYPE Name of option Remark Fresh air intake kit Drain pump kit L-type piping kit (for upward direction) Remote controller FHQ71BVV1B Wireless type Heat pump Wired type1 "Nav Ease" Central remote controller Unified ON/OFF controller Schedule timer Touch Controller Adaptor for wiring Wiring adaptor for electrical appendices4 Interface adaptor for SkyAir series Installation box for adaptor PCB Remote sensor (for indoor temperature) Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Kit name FHQ100BVV1B FHQ125BVV1B ---------KDU50N125VE KHFP5MA160 BRC7EA63W BRC1E62 DCS302CA61 2 DCS301BA61 2 DST301BA61 2 DCS601C51 2 KRP1BA54 KRP4AA52 DTA112BA51 KRP1CA93 KRCS01-1B KJB311AA KJB212AA FHQ140CAVEA KDDQ50A140 KDU50P140VE KHFP5N160 BRC7GA53 DCS302CA61 3 DCS301BA61 3 DST301BA61 3 DCS601C51 3 ---------KRP1D93A KRCS01-4B Note: 1Wiring for wired remote controller to be procured locally. 2 This optional accessory requires DTA112BA51. 3 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 4 Installation box for adaptor PCB is necessary. WALL MOUNTED TYPE Name of option Kit name Remark Drain-up kit Remote controller FAQ71CVEA FAQ100CVEA K-KDU572EVE BRC7EB518 BRC1E62 KRCS01-4B DCS302CA61 DCS301BA61 DST301BA61 DCS601C51 KRP4AA51 KRP4AA93 KJB311AA KJB212AA KEK26-1A Heat pump Wireless type Wired type1 "Nav Ease" Remote sensor (for Indoor temperature) Central remote controller2 Unified ON/OFF controller2 Schedule timer2 Touch Controller2 Wiring adaptor for electrical appendices3 Installation box for adaptor PCB Electrical box with earth terminal (3 blocks) Electrical box with earth terminal (2 blocks) Noise filter ( For electromagnetic interface use only) Note: 1Wiring for wired remote controller to be procured locally. 2 The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 3 Installation box for adaptor PCB (KRP4AA93) is necessary. Outdoor unit Name of option Central drain plug Wire fixture for preventing overturning Fixture for preventing overturning Demand adaptor 23 Kit name Heat pump RZQ100KCV4A RZQ125KCV4A RZQ140KCV4A RZQ50KBV4A RZQ60KBV4A RZQ71KCV4A RZQ100HAY4A RZQ125HAY4A RZQ140HAY4A KKPJ5F180 K-KYZP15C KPT-60B160 KRP58M51 DIMENSIONS (Unit: mm) CEILING MOUNTED CASSE TTE TYPE [FCQ50-140KVEA] [FCQ50-140KVEA] [FCQ50-71KVEA] [FCQ100-140KVEA] B 167 160 67 29 95 160 67 95 29 80 C/L Connection position of branch duct (round shape type) Connection position of fresh air intake kit (direct installation type) 90 90 167 93 157 350 2 100=200 80 213 25 160 157 350 2x100=200 80 25 124 80 160 213 95 110 124 35 or less (Note 4) Connection position of branch duct (square-shaped type) C/L Connection position of branch duct (square-shaped type) 20-M4 Prepared hole ø1 Connection position (kn 00 of branch duct ock hole (round shape type) ) 90 Connection position 183 of fresh air intake kit C arrow view (direct installation type) 4 1 2 35 or less (Note 4) Connection position of branch duct (round shape type) 55 85 27-M4 Prepared hole 5 256 157 350 A 67 160 64 50 840 2 100=200 160 60 105 81 35 or less (Note 4) Connection position of branch duct (square-shaped type) 1500 or more (required space) From the floor side 2500 or more For height installation 157 280 330 A 42 125 165 20 C/L 350 157 350 3 55 150 160 298 95 167 850 Adjustable(0~675) Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) Connection position of branch duct (square-shaped type) B arrow view ø1 (kn 00 holock e) 90 196 C arrow view [FCQ100-140KVEA] 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 175 29 50 40 160 288 10 840 340 80 2 100=200 80 160 256 1500 or more (required space) From the floor side 2500 or more For height installation 2 27-M4 Prepared hole 55 5 130 60 840 81 2x100=200 85 64 124 50 42 105 55 [FCQ100-140KVEA] 55 157 350 [FCQ100-140KVEA] 160 124 109 95 Connection position of branch duct (square-shaped type) 20-M4 Prepared hole 95 167 93 29 280 330 1 150 124 256 850 Adjustable(0~675) 95 110 125 165 4 3 35 or less (Note 4) Connection position of branch duct (round shape type) 157 350 Connection position of branch duct (square-shaped type) [FCQ50-71KVEA] 7 [FCQ50-71KVEA] 175 29 160 246 10 50 40 20 C/L Hanging bolt 4-M8~M10 Connection position of branch duct (round shape type) 16-M4 Hole 6 16-M4 Prepared hole 55 Connection position of branch duct (square-shaped type) 80 Connection position 85 of branch duct (round shape type) 2 100=200 160 C/L Drain Connection Side [FCQ50-71KVEA] 340 80 2 100=200 124 157 350 B arrow view A arrow view 840 81 93 160 124 950 C 85 Connection position of branch duct (round shape type) 16-M4 Hole 95 110 Note 2 8 Piping Connection Side 420 55 2x100=200 124 C/L 81 950 780(Hanging bolt pitch) 860~910(Ceiling opening space) (Note 4) 9 860~910(Ceiling opening space) (Note 4) 710(Hanging bolt pitch) 420 130 300 or less Notes: 1 Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required. 4 Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that the panel overlap allowance can be ensured. 5 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. Required space 200mm or more 1500mm or more 1500mm or more 1500mm or more 200mm or more 1500mm or more The necessary space is 500mm or more when the air-outlet is blocked with the accessory. Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more. 1 2 3 4 5 6 7 8 9 Liquid piping connection Gas piping connection Drain piping connection Transmission wiring connection Remote controller wiring connection Air-outlet Suction grille Corner decoration cover Drain hose (accessory) 24 DIMENSIONS (Unit: mm) CEILING SUSPENDED TYPE 5 (Required space) 6 115 60 11 5 B 30 or more (Service space) 30 or more (Service space) 4 o/ 45 Brand name plate (Note.2) The Front Obstacle Floor side 225 275 300 275 80 2 65 Position : Hole of wall for taking out in piping back (View from the front) 80 105 170 5 7 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 55 14 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas piping connection 5 Liquid piping connection 6 Drain piping connection 7 Earth terminal (inside the electric components box) (M4) 8 Suspension bracket 9 Backward piping and wiring connection opening lid 10 Upward piping and wiring connection opening lid 11 Right side piping connection 12 Left back drain piping connection 13 Left side drain piping connection 14 Right side drain piping connection 15 Hole of wall for taking out in piping back 16 Upward drain piping connection 17 Upward gas piping connection 18 Upward liquid piping connection 6 3 80 90 155 300 or more 55 (Required space) For height installation 13 105 15 1 Drain piping connection VP20 (For left piping) 3 135 8 195 From the floor side 2500 or more 155 10 Hanging bolt 4-M8~M10 65 60 Position slit hole for taking out in piping back (View from the front) 127 A (Hanging position) 680 50 5 135 (Required space) 1550 1590 145 60 40 1360 1400 FHQ125BVV1B 210 FHQ100BVV1B 260 1120 1160 9 12 85 102 160 185 192 36 B FHQ71BVV1B (Hanging position) A 170 105 90 18 17 16 142 58 40 [FHQ71-125BVV1B] 4 (Applies to FHQ71BV only) The remote control code is the standard <about 3 m outside the machine> attached. (0.5 mm2 2 wicks O.D. 5.4) (It is not attached to heat reclaim ventilator.) CEILING SUSPENDED TYPE 12 Position slit hole for taking out in piping back (View from the front) 1550 (Hanging bolt pitch) 690 Hanging bolt 4-M8~M10 4 5 11 Obstacle Floor side 220 103 30 or more (Service space) 1590 30 or more (Service space) The Front Brand name plate (Note.2) 214 221 268 268 6 76 3 2 7 5 83 105 156 4 Notes: 1 Location of unit's Name Plate: Bottom of fan housing inside the suction grille. 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 6 o/ 45 57 14 63 134 59 175 235 300 or more (Required space) 57 13 19 15 91 131 197 1 157 63 115 90 175 92 51 60 8 5 (Required space) From the floor side 2500 or more 197 For height installation 10 Drain piping connection VP20 (For left piping) 25 9 5 (Required space) 260 116 Connection position of fresh air intake kit φ100(Knock out hole) 120 90 40 (Hanging bolt pitch) 210 18 17 20 16 210 156 105 102 131 57 30 87 100 163 189 195 35 [FHQ140CAVEA] Position : Hole of wall for taking out in piping back (View from the front) 1 Air discharge grille 2 Air suction grille 3 Air filter 4 Gas piping connection 5 Liquid piping connection 6 Drain piping connection 7 Earth terminal (inside the control box) (M4) 8 Hanger 9 Rear piping penetration cover 10 Top panel penetration cover 11 Right side piping connection 12 Left back drain piping connection 13 Left side drain piping connection 14 Right side drain piping connection 15 Hole of wall for taking out in piping back 16 Upward drain piping connection 17 Upward gas piping connection 18 Upward liquid piping connection WALL MOUNTED TYPE [FAQ71CVEA] 50 or more (Required space) Piping direction Approx.400 240 238 30 or more (Required space) 7 290 Dimensions for full open front panel 9 3 Piping direction 1 Name plate Note)2 50 or more (Requred space) Piping direction 1050 14.5 2 8 104 50 or more (Requred space) 894 2500 or more For installation in high spaces 120 or less 52 φ80 hole Piping and Wiring intake Outside line 60 Mounting location 6 5 4 Approx.345 98 Approx.390 44 44 105 φ80 hole 1 2 3 4 5 6 7 8 9 Approx.475 Notes: 1 Location of unit's of Name Plate:Right side surface of casing 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. Front panel Front grill Air outlet Gas piping Liquid piping Drain hose Earth terminal Right side piping connection hole Left side piping connection hole WALL MOUNTED TYPE [FAQ100CVEA] 242 50 or more (Required space) Piping direction Approx.440 240 Dimensions for full open front panel 1 50 or more (Requred space) Piping direction 1200 79.5 3 Name plate Note)2 Piping direction 1085 2500 or more For installation in high spaces 50 or more (Requred space) 8 120 or less 35.5 φ80 hole Outside line Piping and Wiring intake 45 45 φ80 hole 6 65 Mounting location 5 4 Approx.400 Approx.460 89 Approx.465 Notes: 1 Location of unit's of Name Plate:Right side surface of casing 2 In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote contorller in detail. 3 Please do not place the thing been damp and troubled under an indoor unit. when the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall. 114 2 14.5 9 30 or more (Required space) 340 7 1 2 3 4 5 6 7 8 9 Front panel Front grill Air outlet Gas piping Liquid piping Drain hose Earth terminal Right side piping connection hole Left side piping connection hole 26 DIMENSIONS (Unit: mm) OUTDOOR UNIT // RZQ50KBV4A, 60KBV4A, 71KCV4A 43 61 320 350 (345~355) 30 Hole for anchor bolt 4-M12 140 30 41 3 4 2 1 7 6 5 7 6 5 89 28 89 142 71 19 223 53 95 19 80 52 145 16 13 67 70 102 117 58 16 8 54 95 84 55 54 95 60 339 341 55 770 30 94 140 620 900 5 45 376 1 2 3 4 5 6 7 8 191 Gas piping connection Liquid piping connection Service port Earth terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake Transmission wiring intake Drain piping connection OUTDOOR UNIT // RZQ100KCV4A, 125KCV4A, 140KCV4A 320 30 22 44 43 350 (345~355) 30 Hole for anchor bolt 4-M12 94 620 140 140 900 30 3 4 2 1 7 7 7 6 6 5 161 52 145 9 48 12 11 58 3 Service port 4 Earth terminal 42 70 102 117 1 Gas piping connection 2 Liquid piping connection 45 27 71 38.16 19 142 8 40 68 54 19 60 68 64 54 89 60 422 423 5 39.4 5 68.4 1170 6 376 191 5 5 Refrigerant piping intake 6 Power supply wiring intake 7 Transmission wiring intake 8 Drain piping connection OUTDOOR UNIT // RZQ100HAY4A, 125HAY4A, 140HAY4A 320 55 36 350 (345~355) (Pitch of foundation bolt holes) 30 Hole for anchor bolt 4-M12 30 38 91 140 30 620 140 (Pitch of foundation bolt holes) 900 3 4 2 1 6 7 5 6 8 58 71 102 117 376 191 95 80 52 145 13 67 16 5 45 53 19 16 71 84 95 54 19 5 55 435 95 54 416 60 89 24 89 142 6 55 5 7 223 1345 7 1 2 3 4 5 6 7 8 Gas piping connection Liquid piping connection Service port Earth terminal M5 (in switch box) Refrigerant piping intake Power supply wiring intake Transmission wiring intake Drain piping connection 28 DIMENSIONS (Unit: mm) REMOTE CONTROLLER Wireless type CEILING MOUNTED CASSETTE TYPE <Round Flow> Receiver installation procedure Remote controller holder installation procedure <installation to wall surface> Remote controller dimensions • Transmitting part Receiver Refrigerant piping side Receiver detail 157 Liquid crystal remote controller (wireless) Remote controller holder 62 Drain piping side 17.5 Decoration panel WALL MOUNTED TYPE • Receiver installation procedure CEILING SUSPENDED TYPE • Receiver installation procedure FHQ71-125BVV1B Receiver FHQ140CAVEA The Front The Front Receiver Receiver • Receiver detail • Receiver detail • Receiver detail BRC1E62 • Remote controller dimensions Upper case • Installation method Lower case A Exposed cord Top left outlet 42 B Embedded cord Staple 19 Condit C Embedded cord (use switch box) 19 40 84 40 84 Operation lamp (Green) 120 Top center outlet 84 Wired type 120 19 5X7 oblong hole 28 23 48.5 46 Code outlet hole 5X15 oblong hole 48.5 Left outlet 19 Lower case portion Note)2 28 Through hole Switch box for one switch ( 8- 10) ex.) KJB111A (optional accessory) Lower case Note) 1. Remote controller cord and staple are not attached. They are field supplied parts. Specifications of cord 29 Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more) Size 0.75~1.25 mm2 Total length 500 m 46 0~5 Switch box for two switch (Between remote ex.) KJB211A controller and (optional accessory) control box) Switch box portion [field supplied part] 2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller. Installation service space for outdoor unit For RZQ50/60KBV4A, RZQ71KC-140KCV4A, RZQ100-140HAY4A The values represent the case for the RZQ100-140KCV4A and RZQ100-140HAY4A. The dimensions in ( ) are for the RZQ50/60KBV4A and RZQ71KCV4A (The unit values is mm. ) 1 When there is an obstruction on the inlet side 2 When there is an obstruction on the outlet side 1) When the overhead space is open 1) When the overhead space is open 1. For single unit installation 1. For single unit installation re 0 0(5 10 100 or m ore 100 r 0o or m 100 or more re ore rm 0o 0 10 10 ore 2) When there is an obstruction in the overhead space 0 50 s les or 1. For single unit installation 100 or more 100 or more 00 or An obstruction in the overhead space mo re 0o rm ) 00 re mo or 0(2 ore 30 2. For series installation (more than two units) 2) When there is an obstruction in the overhead space ss An obstruction in the overhead space e or 3 When there are obstructions on both the inlet and outlet sides 1000 or more 1 ess rl 0o ore rm 0o 0 10 rm o 00 50 100 or more 1000 or more r le 0o 50 An obstruction in the overhead space 100 or more ss r le 0o 50 An obstruction in the overhead space 1. For single unit installation When there are obstructions on the inlet side and both lateral sides ore rm 0o 50 1000 or more 10 20 When there is an obstruction on the inlet side 100 or more mo 2. For series installation (more than two units) When there are obstructions on both sides 50 2. For series installation (more than two units) When there are obstructions on both sides ore rm 0o mo r )o 1000 or more When there is an obstruction only on the inlet side (When the obstruction on the outlet side is higher than the unit itself) 1) When the overhead space is open 150 or m ore 150 e or or m 0 ore 15 m or (There is no limit to the height of the obstruction on the outlet side.) H 1. For single unit installation An obstruction in the overhead space or 2. For series installation (more than two units) 100 or more 0 50 ore m or 100 or more 100 or more mo re 20 0o rm ore ) 00 0(2 re 30 r mo o L H 0) 0(5 e 10 mor or H 00 H L 10 r 0o 50 s les L 1000 or more When there are obstructions on the inlet side and both lateral sides 100 or more L 2. For series installation (more than two units) 00 10 ore m or ) 00 0(2 re 30 r mo o Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book. 30 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION JMI-0107 Scope of Registration: The design/development and manufacture of commercial air conditioning, heating, cooling, refrigerating equipment, heating equipment, residential air conditioning equipment, heat reclaim ventilation, air cleaning equipment, compressors and valves. DEALER: Organization: DAIKIN INDUSTRIES (THAILAND) LTD. JQA-1452 Scope of Registration: The design / development and manufacture of air conditioners and the components including compressors used for them Quality ISO 9001 Daikin Australia Pty Limited (ISO9001) QEC23256 May 12, 2006 Sydney, Brisbane, Adelaide, Melbourne, Newcastle, Townsville, Perth, Auckland All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management. Environment ISO 14001 Daikin Australia Pty Limited (ISO14001) CEM20437 October 27, 2006 Sydney, Brisbane, Melbourne, Adelaide, Perth Daikin Australia Pty Limited ABN 62 000 172 967 Email: [email protected] Phone: 1300 368 300 (AU) Phone: 0800 324 546 (NZ) commercial.daikin.com.au Specifications, designs and other content appearing in this brochure are current as of September 2013 but subject to change without notice. c All rights reserved 09/13 SS