Chapter 2: Installing your PEC Plus
Phason
Connecting single-stage heating or cooling elements
Heating or cooling elements include equipment such as electric heaters, furnaces, single-speed fans,
and curtains.
The ratings of the equipment must not exceed the ratings of your PEC Plus’ relays.
PEC Plus relay ratings:
10 A at 120/230 VAC, general-purpose (resistive)
1/3 HP at 120 VAC, 1/2 HP at 230 VAC
360 W tungsten at 120 VAC
Refer to Appendix D: Installation worksheet on page 82 and Appendix E:
Configuration worksheets on page 84 when installing single-stage heating or
cooling elements.
To connect single-stage heating or cooling elements
Connect single-speed heating or cooling elements to your PEC Plus as shown below.
Gas-fired furnace or brooder
All other single-speed heating or cooling elements
STG-1
STG-1
Thermostat
inputs
L1
L1
L2/NEUTRAL
Junction box
L2/NEUTRAL
Gas furnaces using hot-surface ignition or glow plug can draw more current than
indicated on their nameplate and require power contactors. For more information,
read your furnace dealer.