PmacMotorPVE is an extension of the position, velocity, and following error VIs that combine them into a single VI that can be used to drive the PmacMotorPVE indicator. The use of these VIs is shown in the diagram below. • PmacMotorPVE - Query PMAC for the position, velocity, and following error for Motor Number operating in Coord Number. Assemble the measurements into Motor PVE Cluster. If Convert is TRUE convert the measurements to CS units. Otherwise, leave them in encoder counts. See the documentation for PmacMotorPosition, PmacMotorVelocity, and PmacMotorError for details on how these individual values are produced. A Coordinate Specify Cluster is assembled from three controls on the panel. Each of the individual Position, Velocity, and Error VIs receives the cluster. The P, V, and E VI outputs are used to drive three individual numeric indicators. In this example, the indicators have an attribute node to set their color. The color for the text is provided by PmacCoordColor. The indicator color is Orange if the reported value is in CS units and Blue if it is in encoder counts. 70 Chapter 4 – Application Basics