Download User Manual User Manual User Manual User Manual User Manual

Transcript
www.vscom.de
User
User Manual
Manual
NetCom Lite
Edition:
Edition: January
January 2012
2012
Tel: +49 40 528 401 0
Fax: +49 40 528 401 99
Web: www.visionsystems.de
Support: [email protected]
The software described in this manual is furnished under a license agreement and may be used
only in accordance with the terms of that agreement.
Copyright Notice
Copyright © 2009-2012 Vision Systems. All rights reserved. Reproduction without permission is
prohibited.
Trademarks
VScom is a registered trademark of Vision Systems GmbH. All other trademarks and brands are
property of their rightful owners.
Disclaimer
Vision Systems reserves the right to make changes and improvements to its product without providing notice.
Vision Systems provides this document “as is”, without warranty of any kind, either expressed or
implied, including, but not limited to, its particular purpose. Vision Systems reserves the right
to make improvements and/or changes to this manual, or to the products and/or the programs
described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Vision
Systems assumes no responsibility for its use, or for any infringements on the rights of third parties
that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated
into new editions of the publication.
January 2012
NetCom Lite User Manual
2
Contents
Contents
1 Overview
10
2 Introduction
2.1 About this Manual . . . . . . . . . . . . . . . . . . . . . .
2.2 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Product Specifications . . . . . . . . . . . . . . . . . . . .
2.3.1 Common characteristics . . . . . . . . . . . . . . .
2.3.2 Device specific Characteristics . . . . . . . . . . .
2.3.2.1 NetCom 111 / 113 / 111 PoE / 113 PoE
2.3.2.2 NetCom 211 / 211 PoE . . . . . . . . . .
2.3.2.3 NetCom 411 / 413 . . . . . . . . . . . . .
2.3.2.4 NetCom 811 / 813 . . . . . . . . . . . . .
2.3.2.5 NetCom 811RM / 813RM (19") . . . . .
2.4 Packing List . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
10
10
11
12
12
13
13
14
15
16
18
19
3 Hardware Description
3.1 Serial Port Configuration . . . . . .
3.2 Signal Assignment . . . . . . . . . .
3.2.1 Serial DB9 male . . . . . . .
3.2.2 Serial RJ45 to DB9 male . .
3.2.3 Serial DB9 female . . . . . .
3.3 RS 422/485 Electrical Configuration
3.3.1 Termination Resistors . . . .
3.4 Serial Port Simple Settings . . . . .
3.5 Network . . . . . . . . . . . . . . . .
3.6 Power Supply . . . . . . . . . . . . .
3.6.1 Round Power Jack . . . . . .
3.6.2 Terminal Block Power . . . .
3.6.3 AC Power Plug . . . . . . . .
3.6.4 Power over Ethernet . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
20
20
21
21
22
22
22
23
23
23
24
24
24
24
25
4 Windows Virtual COM Driver
4.1 Installation Procedure . . . . . . . . . . . .
4.1.1 Start the Installation Wizard . . . .
4.1.2 Find and Configure NetCom Devices
4.1.2.1 Configure IP Parameters .
4.1.2.2 Configure Firewall . . . . .
4.1.3 Install Drivers . . . . . . . . . . . .
4.2 Verify the Installation . . . . . . . . . . . .
4.3 Update the Drivers and Tools . . . . . . . .
4.4 Configuration of the Virtual COM Driver .
4.4.1 Configure the Serial Ports . . . . . .
4.4.2 Performance Issues . . . . . . . . . .
4.4.3 Network & Misc Properties . . . . .
4.4.4 Remote Settings Properties . . . . .
4.4.5 Installation of NetCom Servers . . .
4.4.5.1 Changing the Installation .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
26
26
26
29
29
31
31
33
34
34
35
36
38
40
42
43
January 2012
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
NetCom Lite User Manual
3
Contents
4.5
Uninstall the Drivers and Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
5 Configure with NetCom Manager
5.1 Starting NetCom Manager . . . . . . . . . . . . . .
5.2 NetCom Server Settings – Info . . . . . . . . . . .
5.3 NetCom Server Settings – Ports . . . . . . . . . . .
5.4 NetCom Server Settings – Firewall . . . . . . . . .
5.5 NetCom Server Settings – Options . . . . . . . . .
5.6 Manual Detection/Installation of a NetCom . . . .
5.7 Firewall Traversal Configuration . . . . . . . . . .
5.7.1 SOHO Firewall example . . . . . . . . . . .
5.7.2 SOHO Virtual Servers . . . . . . . . . . . .
5.7.3 NetCom Detection through SOHO Firewall
5.7.4 Serial Ports through SOHO Firewall . . . .
5.7.5 DMZ and Virtual Servers . . . . . . . . . .
5.8 NetCom Helper Service . . . . . . . . . . . . . . .
5.8.1 Configure Helper Service . . . . . . . . . . .
5.8.2 Detection and Priority . . . . . . . . . . . .
5.8.2.1 Broadcast Search . . . . . . . . .
5.8.2.2 DNS based Search . . . . . . . . .
5.8.2.3 DNS based Firewall Configuration
5.8.3 Changed IP Address . . . . . . . . . . . . .
5.8.3.1 Broadcast Domain . . . . . . . . .
5.8.3.2 Internal DNS . . . . . . . . . . . .
5.8.3.3 Internet . . . . . . . . . . . . . . .
5.8.4 Polling Period . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
46
47
48
49
50
51
52
52
52
53
53
54
55
55
55
56
56
56
57
57
57
58
58
58
6 Configure the Operation Modes
6.1 Accessing the Configurations . . . . . . . . . . .
6.1.1 Web Browser Configuration . . . . . . . .
6.1.2 Telnet Configuration . . . . . . . . . . . .
6.1.3 Serial Configuration . . . . . . . . . . . .
6.2 NetCom Configuration Options . . . . . . . . . .
6.2.1 Server Configuration . . . . . . . . . . . .
6.2.1.1 Server Info . . . . . . . . . . . .
6.2.1.2 Server Parameter . . . . . . . .
6.2.1.3 Authentication . . . . . . . . . .
6.2.1.4 Date & Time . . . . . . . . . . .
6.2.1.5 Save . . . . . . . . . . . . . . . .
6.2.2 Serial Port Configuration . . . . . . . . .
6.2.2.1 Serial Settings . . . . . . . . . .
6.2.2.2 Transfer Settings . . . . . . . . .
6.2.2.2.1 Driver Mode . . . . . .
6.2.2.2.2 TCP Raw Server . . . .
6.2.2.2.3 TCP Raw Client . . . .
6.2.2.2.4 Null Modem Tunnel . .
6.2.2.2.5 TCP Advanced Settings
6.2.2.2.6 UDP Data Transfer . .
6.2.2.2.7 IP-Modem . . . . . . .
6.2.2.2.8 Print Server Function .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
59
59
59
60
62
62
62
63
64
65
65
66
67
68
70
70
71
72
73
75
77
78
79
January 2012
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
NetCom Lite User Manual
4
Contents
6.2.2.3 Save . . . . . . . . . . . . . .
NetCom Tools . . . . . . . . . . . . .
6.2.3.1 Ping . . . . . . . . . . . . . .
6.2.3.2 Statistics . . . . . . . . . . .
6.2.3.3 Netstat . . . . . . . . . . . .
6.2.3.4 Firmware . . . . . . . . . . .
6.2.3.5 Save and Load Configuration
6.2.3.6 Logging and Debug . . . . .
6.2.3.7 Save . . . . . . . . . . . . . .
6.2.4 Reboot . . . . . . . . . . . . . . . . .
6.2.5 Save&Exit Menu . . . . . . . . . . . .
6.2.5.1 Save Parameter . . . . . . .
6.2.5.2 Exit . . . . . . . . . . . . . .
6.2.5.3 Reboot . . . . . . . . . . . .
Erase Configuration of NetCom . . . . . . . .
6.2.3
6.3
7 IP Modem Function
7.1 Some possible Scenarios . . . . . . . . . . . .
7.2 Serial Signals and Cables . . . . . . . . . . .
7.3 Operation Modes by IP Modem . . . . . . . .
7.4 Hayes Commands . . . . . . . . . . . . . . . .
7.4.1 AT command set . . . . . . . . . . . .
7.4.1.1 Standard AT-Commands . .
7.4.1.2 Extended AT-Commands . .
7.4.1.3 Non-AT commands . . . . .
7.4.2 S-Registers for Configuration . . . . .
7.4.3 Sample Commands used by Windows
7.5 Description of AT–Commands . . . . . . . . .
7.5.1 AT D (dial) . . . . . . . . . . . . . . .
7.5.2 AT O (online / data mode) . . . . . .
7.5.3 AT A (answer call) . . . . . . . . . . .
7.5.4 AT B (modulation) [ATB1] . . . . . .
7.5.5 AT E (echo) [ATE1] . . . . . . . . . .
7.5.6 AT Q (quiet) [ATQ0] . . . . . . . . .
7.5.7 AT V (verbose) [ATV1] . . . . . . . .
7.5.8 AT H (hangup) [ATH0] . . . . . . . .
7.5.9 AT I(n) (information) [ATI0] . . . . .
7.5.10 AT S (setup) . . . . . . . . . . . . . .
7.5.11 AT L (loudness) . . . . . . . . . . . .
7.5.12 AT M (speaker) . . . . . . . . . . . .
7.5.13 AT N (auto baud) [ATN0] . . . . . . .
7.5.14 AT Z (reset) . . . . . . . . . . . . . .
7.5.15 AT &F (factory settings) [AT&F0] . .
7.5.16 AT &C (DCD configuration) [AT&C1]
7.5.17 AT &S (DSR configuration) [AT&S0]
7.5.18 AT &D (DTR configuration) [AT&D2]
7.5.19 AT &K (handshake) [AT&K3] . . . .
7.5.20 AT \Q [AT\Q3] . . . . . . . . . . . .
7.5.21 AT &V (view profile) . . . . . . . . .
January 2012
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
NetCom Lite User Manual
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
80
80
81
81
82
85
85
86
87
87
87
87
88
88
88
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
90
90
90
91
91
92
92
92
93
93
93
93
94
94
94
94
95
95
95
95
95
96
96
96
96
96
97
97
97
97
98
98
98
5
List of Figures
7.5.22 AT &W (save profile) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
7.5.23 AT &Z (save destination) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
8 Print Server Operation
8.1 Printer Queue . . . . . . . . . . . . . . . . .
8.2 Printer Reset . . . . . . . . . . . . . . . . .
8.2.1 Init String Definition . . . . . . . . .
8.2.1.1 ASCII Text . . . . . . . . .
8.2.1.2 ASCII Control Codes . . .
8.2.1.3 Numeric Codes . . . . . . .
8.2.1.4 Modem Control Signals . .
8.2.1.5 Timing Options . . . . . .
8.2.2 Reset Example . . . . . . . . . . . .
8.3 Operation in Windows® . . . . . . . . . . .
8.3.1 Add a New Printer . . . . . . . . . .
8.3.1.1 Create new printer port . .
8.3.1.2 Name the new Printer Port
8.3.1.3 Configure the Printer Port
8.3.1.4 Install Printer Driver . . .
8.3.2 Modify an Existing Printer . . . . .
8.3.2.1 Open the properties . . . .
8.3.2.2 Add the Print Server Port
9 TCP/IP Description
9.1 Recommended Settings . . . . . . . . . . .
9.1.1 Static Configuration . . . . . . . .
9.1.2 DHCP Configuration . . . . . . . .
9.1.3 Automatic Configuration (APIPA)
9.1.4 Other Configuration . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
99
99
99
99
100
100
100
100
100
100
101
101
101
102
103
103
103
103
104
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
105
. 105
. 105
. 105
. 106
. 106
10 Troubleshooting Guide
107
11 Glossary of Terms
110
12 History
113
List of Figures
1
2
3
4
5
6
7
8
9
10
11
NetCom 111 Top and Front Side . . . . . . . .
NetCom 211 Top and Front Side . . . . . . . .
NetCom 413 Top, Front and Rear Side . . . . .
NetCom 813 Top and Front Side . . . . . . . .
NetCom 811 / 813 Rear Sides . . . . . . . . . .
NetCom 811RM / 813RM Top and Front Side .
NetCom 811RM / 813RM Rear Side . . . . . .
Connector DB9 male . . . . . . . . . . . . . . .
Connector RJ45 and DB9 male . . . . . . . . .
Connector DB9 female . . . . . . . . . . . . . .
RS 422/485 Option Jumper . . . . . . . . . . .
January 2012
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
NetCom Lite User Manual
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
14
15
16
17
18
18
21
22
22
23
6
List of Figures
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
DIP NetCom 211 . . . . . . . . . . . . . . . . . . . .
DIP Other NetCom . . . . . . . . . . . . . . . . . .
Round Power Jack . . . . . . . . . . . . . . . . . . .
Power Terminal Block . . . . . . . . . . . . . . . . .
AC Power input . . . . . . . . . . . . . . . . . . . .
Installation Wizard . . . . . . . . . . . . . . . . . . .
NetCom Driver Installation . . . . . . . . . . . . . .
Start Driver Installation . . . . . . . . . . . . . . . .
Copy Driver Files . . . . . . . . . . . . . . . . . . . .
Discover and Select NetCom Devices for Installation
NetCom in Manager . . . . . . . . . . . . . . . . . .
Define NetComs IP Configuration . . . . . . . . . . .
DNS Name for NetCom Server . . . . . . . . . . . .
Sending Parameters to a NetCom . . . . . . . . . . .
Virtual Com Ports installing . . . . . . . . . . . . . .
New Hardware Wizard . . . . . . . . . . . . . . . . .
Install drivers for the serial ports . . . . . . . . . . .
VScom drivers in the Start Menu . . . . . . . . . . .
NetCom in Device Manager . . . . . . . . . . . . . .
NetCom Manager NT . . . . . . . . . . . . . . . . .
NetCom COM Port Serial Settings . . . . . . . . . .
NetCom COM Port Performance Settings . . . . . .
NetCom COM Port Network/Misc Properties . . . .
NetCom COM Port Remote Settings Properties . . .
Select NetCom to install . . . . . . . . . . . . . . . .
Excluded NetCom . . . . . . . . . . . . . . . . . . .
NetCom Manager Ports View . . . . . . . . . . . . .
Reconfigured NetCom found . . . . . . . . . . . . . .
Replaced NetCom found . . . . . . . . . . . . . . . .
Uninstall NetCom Drivers via Control Panel . . . . .
Uninstall NetCom Drivers in Start Menu . . . . . . .
Remove, Repair . . . . . . . . . . . . . . . . . . . . .
NetCom Manager . . . . . . . . . . . . . . . . . . . .
NetCom Manager in Start Menu . . . . . . . . . . .
NetCom Manager Servers Panel . . . . . . . . . . .
NetCom Manager Server Settings - Info . . . . . . .
NetCom Manager Server Settings - Ports . . . . . .
NetCom Manager Server Settings - Firewall . . . . .
NetCom Manager Server Settings - Options . . . . .
NetCom Manager Port Configuration for Driver . . .
NetCom Helper Service . . . . . . . . . . . . . . . .
Enter Qualified Domain Name . . . . . . . . . . . .
Configuration Menu in Web Browser . . . . . . . . .
Request to Reboot in Web Browser . . . . . . . . . .
Password Request in Telnet . . . . . . . . . . . . . .
Select Terminal Type in Telnet . . . . . . . . . . . .
Main Menu of Configuration Console in Telnet . . .
Server Information . . . . . . . . . . . . . . . . . . .
Server Parameter . . . . . . . . . . . . . . . . . . . .
January 2012
NetCom Lite User Manual
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
23
24
24
24
26
27
28
28
29
29
30
30
31
31
32
33
33
34
34
35
36
38
40
42
42
43
43
44
44
45
45
46
46
47
48
49
50
51
54
56
56
60
60
61
61
61
63
64
7
List of Tables
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
Access Authentification . . . . . . . . . . . .
Date & Time Retrieval Options . . . . . . . .
Port Page Selection in Web Browser . . . . .
Port Selection in Telnet . . . . . . . . . . . .
Serial Settings . . . . . . . . . . . . . . . . . .
Advanced Flow Control . . . . . . . . . . . .
Serial Port Mode Selection . . . . . . . . . . .
Driver Mode parameters . . . . . . . . . . . .
TCP Raw Server parameters . . . . . . . . .
TCP Raw Client parameters . . . . . . . . .
Null Modem Tunnel . . . . . . . . . . . . . .
TCP Advanced Settings . . . . . . . . . . . .
UDP Data Transfer . . . . . . . . . . . . . . .
IP-Modem . . . . . . . . . . . . . . . . . . . .
Print Server Configuration . . . . . . . . . . .
Ping and Response in Web Browser . . . . .
Ping and Response in Telnet . . . . . . . . .
Statistics Port Selection . . . . . . . . . . . .
Port Statistics . . . . . . . . . . . . . . . . . .
Start Netstat . . . . . . . . . . . . . . . . . .
Netstat Sample Output . . . . . . . . . . . .
Firmware Upload . . . . . . . . . . . . . . . .
Save and Load Configuration in Web Browser
Syslog & Debuglog Parameters . . . . . . . .
Menu Save modified Parameters in Telnet . .
Menu Exit from Configuration in Telnet . . .
Exit and Reboot in Telnet . . . . . . . . . . .
Add a printer . . . . . . . . . . . . . . . . . .
Select Printer Port . . . . . . . . . . . . . . .
Create Printer Port . . . . . . . . . . . . . . .
Name-Properties of Print Server Port . . . .
Mode-Properties of Print Server Port . . . . .
Select Port for Printer . . . . . . . . . . . . .
Add Printer Port . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
65
66
67
67
68
69
70
71
72
73
74
76
77
78
79
81
81
82
82
83
83
85
86
86
87
88
88
101
101
102
102
103
104
104
Specifications, common . . . . . . . . . . . . .
Characteristics of NetCom 111 / 113 / 111 PoE
Characteristics of NetCom 211 / 211 PoE . . .
Characteristics of NetCom 411 . . . . . . . . .
Characteristics of NetCom 811 / 813 . . . . . .
Characteristics of NetCom 811RM / 813RM . .
Switch Configurations . . . . . . . . . . . . . .
Switch Configurations NetCom 211 . . . . . . .
Signals DB9 male . . . . . . . . . . . . . . . . .
Signals DB9 male / RJ45 (NetCom 211) . . . .
Signals DB9 female . . . . . . . . . . . . . . . .
.
/
.
.
.
.
.
.
.
.
.
. . . . . .
113 PoE
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
12
13
14
15
16
18
20
21
21
22
22
List of Tables
1
2
3
4
5
6
7
8
9
10
11
January 2012
NetCom Lite User Manual
8
List of Tables
12
13
14
15
16
17
18
19
20
21
22
23
RS 422/485 Jumper Configuration . . .
LED Function . . . . . . . . . . . . . . .
SOHO Firewall Pass-Through . . . . . .
IP Modem cable . . . . . . . . . . . . .
IP Modem Standard AT Commands . .
IP Modem Extended AT-Commands . .
IP Modem S-Registers for Configuration
IP Modem Sample Dials . . . . . . . . .
IP Modem virtual Modulation . . . . . .
IP Modem Responses . . . . . . . . . .
IP Modem Information Responses . . .
IP Modem DTR Configuration . . . . .
January 2012
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
NetCom Lite User Manual
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
23
24
53
91
92
92
93
94
95
95
96
97
9
2
Introduction
1 Overview
The NetCom Lite Serial Device Servers are designed to remotely operate serial ports over networks.
The network interface is implemented as 100 Mbit/s Fast Ethernet. The transport is implemented
via TCP/IP and UDP protocols. Therefore control is available via Ethernet, Intranet and Internet.
The supplied driver software implements virtual serial ports, which hide the network transfer from
your applications. Software applications using standard COM ports need no change to operate via
NetCom through the virtual serial ports.
2 Introduction
This manual covers several different models of NetCom Lite devices. In general the operation is
the same on all models, except where explicitly noted otherwise. The devices come with a steel
case well suited for industrial environments.
The NetCom supports high serial speeds up to 460 kbps or 921 kbps. All serial ports provide
communication via the common RS 232 mode. The NetCom Lite servers with a ‘13’ in their name
also offer the industrial RS 422 and RS 485 configuration. In RS 485 mode the NetCom may use the
Automatic Receive Transmit (ART) control logic to follow the RS 485 specifications for transmitting
data. No special code is necessary to be implemented in your software applications.
Some latest models of NetCom Lite servers allow to get the power supply via the Ethernet/LAN
cable. The option of PoE (Power over Ethernet) has no impact on application software. Existing programs do not require any change. Therefore this manual mentions the PoE option only
occasionally. For most questions the PoE option is ignored.
2.1 About this Manual
This manual covers many configuration options of the NetCom Lite Serial Device Servers. The
vast majority of these are set by software, sometimes in alternatives methods. To emphasize these
in the text, special character styles are used.
Bold Typewriter
Typewriter
is used for the names of configuration options or buttons, as they are
displayed in menus or dialogs.
denotes names of special values for multiple-choice parameters. Such values
may appear in drop-down lists or as radio buttons.
The version of the firmware described in this manual is 2.6.3, covered together with driver 1.5.12.0.
January 2012
NetCom Lite User Manual
10
2
Introduction
2.2 Features
• Single power supply
DC 9-30V, 200-600 mA@12V; or
AC 100-240V 47-63Hz, 25VA; or
Power over Ethernet as of IEEE 802.3af (up to 3 W)
• Ethernet 10/100BaseTx for auto-configuration
• Three way serial port interfaces: RS 232, RS 422 and RS 485
• Max. 921.600 bps, half- and full-duplex
• TCP/IP configuration fixed or by DHCP
• Easy remote configuration via SNMP
• Drivers for Windows™ and Linux operating systems
• Documented interface for every networked operating system
January 2012
NetCom Lite User Manual
11
2
Introduction
2.3 Product Specifications
Most of the hardware characteristics are common for all models. However some must differ from
model to model, they are shown in dedicated sections. The new hardware version 2.0 represents
some changes in the features of the products, compared with the previous version.
2.3.1 Common characteristics
Processor
Memory
Ethernet connector
Protocols
Serial Speed
Parity
Data bits
Stop bits
Serial signals
Serial connector
Serial operation
Management
Driver software
Management software
Operating temp.
Approval
ARM7 (S3C4510B)
8 MB SDRAM
2 MB Flash
RJ45 10BaseT/100BaseTx
TCP/IP, UDP, SNMP, DHCP, ICMP, ARP, Telnet, RTelnet, HTTP
up to 921.6 kbps1,2
None, Even, Odd, Mark, Space
5, 6, 7, 8
1, 2 (1.5 with 5 data bits)
RS 232
TxD, RxD, RTS, CTS, DTR, DSR,
DCD, RI, GND
RS 422
Tx+/Tx−, Rx+/Rx−, GND
RS 485 4-wire
RS 485 2-wire
Data+/Data−, GND
DB9 male3
RS 232, RS 422/485 configured by DIP switch
Serial console, Telnet, Web browser, SNMP
Windows Vista/2003/XP/2000, Windows NT, Linux (Fixed TTY)
Driver installation and configuration program, Management console
0° to 55°C
CE, FCC
Table 1: Specifications, common
Note 1: 460.8 kbps on NetCom 111, 113 and 211 (PoE models as well)
Note 2: The serial bitrate of 921.6 kbps may cause problems when used with RS 232. It requires
short cables with low capacity, to reduce load on the serial signals. A realistic maximum bitrate is
460.8 kbps. When using RS 422 or RS 485 there is no problem using maximum bitrates.
Note 3: Previous models provided DB9 female connectors, with optional Null-Modem Adapters.
These are no longer required. Check your cable when using RS 422 or RS 485 transmissions.
January 2012
NetCom Lite User Manual
12
2
Introduction
2.3.2 Device specific Characteristics
The characteristics of certain NetCom models are shown as a short overview for comparison.
2.3.2.1 NetCom 111 / 113 / 111 PoE / 113 PoE One port.
NetCom 111 PoE / 113 PoE
Serial connector
Serial ports
Serial Speed
Power Requirement
Power Connector
Dimensions
Weight
with Power over Ethernet.
DB9 male (like PC)
111: 1 × RS 232
113: 1 × RS 232/422/485 configured by DIP switch
7 bps up to 460.8 kbps
DC 9V to 30V, 200 mA@12V
Power over Ethernet as of IEEE 802.3af (up to 3 W)1
Round power jack (3.6.1)
73×115×27 mm3 (W×D×H)
101×121×27 mm3 with connectors
250 g
Table 2: Characteristics of NetCom 111 / 113 / 111 PoE / 113 PoE
Note 1: Power over Ethernet is available in NetCom 111 PoE / 113 PoE
Figure 1: NetCom 111 Top and Front Side
Here showing NetCom 111 (the NetCom 113 is very similar) with the serial connector and the
configuration switches. The rear side holds the power connector, Reset hole and the Ethernet
RJ45. On NetCom 111 PoE and NetCom 113 PoE the option of Power over Ethernet of course has
no special connector.
January 2012
NetCom Lite User Manual
13
2
Introduction
2.3.2.2 NetCom 211 / 211 PoE
NetCom 211 PoE
Serial connector
Serial ports
Serial signals
Serial Speed
Power Requirement
Power Connector
Dimensions
Weight
Two ports.
with Power over Ethernet.
RJ45, Adapter cable to DB9 male (like PC)
2 × RS 232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
7 bps up to 460.8 kbps
DC 9V to 30V, 200 mA@12V
Power over Ethernet as of IEEE 802.3af (up to 3 W)1
Round power jack (3.6.1)
73×115×27 mm3 (W×D×H)
101×121×27 mm3 with connectors
200 g
Table 3: Characteristics of NetCom 211 / 211 PoE
Note 1: Power over Ethernet is available in NetCom 211 PoE
Figure 2: NetCom 211 Top and Front Side
This is NetCom 211. Visible are the two RJ45 for COM1 and COM2 with the configuration DIP
switch. The hidden rear side is the same as on NetCom 111/113 with Power connector, Reset and
Ethernet RJ45 (fig. 1). The option of Power over Ethernet on NetCom 211 PoE has no special
connector.
January 2012
NetCom Lite User Manual
14
2
Introduction
2.3.2.3 NetCom 411 / 413
Serial connector
Serial ports
Serial Speed
Power Requirement
Power Connector
Dimensions
Weight
Four ports.
DB9 male (like PC)
411: 4 × RS 232
413: 4 × RS 232/422/485 configured by DIP switch
14 bps up to 921.6 kbps
DC 9V to 30V, 400 mA@12V
Round power jack (3.6.1)
169×93×29 mm3 (W×D×H)
169×99×29 mm3 with connectors
500 g
Table 4: Characteristics of NetCom 411
Figure 3: NetCom 413 Top, Front and Rear Side
The front side of NetCom 413 and 411 holds the four DB9 male connectors for the serial ports. On
the rear side are the power jack, the configuration switches (one switch on NetCom 411) and the
Ethernet RJ45.
January 2012
NetCom Lite User Manual
15
2
Introduction
2.3.2.4 NetCom 811 / 813
Serial connector
Serial ports
Serial Speed
Power Requirement
Power Connector
Dimensions
Weight
Eight ports.
DB9 male (like PC)
811: 8 × RS 232
813: 8 × RS 232/422/485 configured by DIP switch
14 bps up to 921.6 kbps
DC 9V to 30V, 600 mA@12V
Terminal Block (3.6.2)
169×93×42 mm3 (W×D×H)
169×99×42 mm3 with connectors
900 g
Table 5: Characteristics of NetCom 811 / 813
Figure 4: NetCom 813 Top and Front Side
The NetCom 811 and 813 provide eight serial ports in two rows of four, equipped with DB9 male
each.
January 2012
NetCom Lite User Manual
16
2
Introduction
Figure 5: NetCom 811 / 813 Rear Sides
On the rear side is the slot for power terminal block, plus the configuration switches (one switch on
NetCom 811) and the Ethernet RJ45. Previous hardware versions of NetCom 811 / 813 provided
a Round Power Jack (see 3.6.1 on page 24) for supply.
January 2012
NetCom Lite User Manual
17
2
Introduction
2.3.2.5 NetCom 811RM / 813RM (19") Phased out, mentioned for reference only.
Serial connector
Serial ports
Serial Speed
Power Requirement
Power Connector
Dimensions
Weight
DB9 male (like PC)
811: 8 × RS 232
813: 8 × RS 232/422/485 configured by DIP switch
14 bps up to 921.6 kbps
AC 100V to 240V, 47-63Hz, 25VA
AC Power plug (3.6.3)
258×149×45 mm3 (W×D×H)
278×155×46 mm3 with connectors
1350 g
Table 6: Characteristics of NetCom 811RM / 813RM
Figure 6: NetCom 811RM / 813RM Top and Front Side
The NetCom 811RM and 813RM are designed for 19” Rackmount usage. They provide eight serial
ports in two rows of four, equipped with DB9 male each. To the left of the front is the Ethernet
RJ45, the Reset hole is in the lower right corner. Also provided is a mounting kit with two angles
for a 19” rack.
Figure 7: NetCom 811RM / 813RM Rear Side
January 2012
NetCom Lite User Manual
18
2
Introduction
On the rear side are the power jack and the configuration switches (a single switch on NetCom
811RM).
2.4 Packing List
• NetCom Lite Serial Device Server
• Power supply 12V 1.0A for DC Models NetCom 111, 113, 211, 411, 413, 811 and 813
• CD-ROM with driver and configuration software
• Quick Installation Guide
January 2012
NetCom Lite User Manual
19
3
Hardware Description
3 Hardware Description
This section focuses on the options provided by the hardware of NetCom Lite Serial Device
Servers
3.1 Serial Port Configuration
The serial ports in the NetCom Devices follow the specifications of RS 232. It is also possible to use
the serial port in RS 422 or RS 485 mode. This is defined by a set of DIP switches or by software.
Here is a list of the available modes and the switch settings.
Warning: a bad configuration may cause serious damage in the NetCom or the connected device.
Line Mode, Comment
S1
S2
S3
S4
RS 232
Configuration via serial port3
Off
Off
Off
Off
RS 232
Data communication
Off
Off
On
On
RS 4221
Data communication
Off
On
On
On
4 wire Full Duplex
On
On
On
Off
–“–
2 wire Half Duplex with Echo
On
On
Off
On
–“–
2 wire Half Duplex no Echo
On
On
Off
Off
4 wire Full Duplex
On
Off
On
Off
–“–
2 wire Half Duplex with Echo
On
Off
Off
On
–“–
2 wire Half Duplex no Echo
On
Off
Off
Off
Factory settings4
Off
Off
Off
On
RS 485 by ART1,2
RS 485 by RTS1
Switch Positions
Table 7: Switch Configurations
Note 1: Line modes of RS 422 and RS 485 are not available on NetCom 111, 411, 811 and 811RM.
Note 2: ART is the Automatic Receive Transmit control. In RS 485 mode this is the recommended
option. The NetCom performs the required activation and disabling of the RS 485 transmitter by
an internal automatic. It is available in NetCom 113, 413, 813 and 813RM models.
January 2012
NetCom Lite User Manual
20
3
Hardware Description
Line Mode, Comment
S1
S2
Switch Positions
RS 232
Configuration via serial port3
Off
Off
RS 232
Data communication
On
On
Factory settings4
Off
On
Table 8: Switch Configurations NetCom 211
Note 3: ‘Configuration via serial port’ is only effective on port 1 of the NetCom Server.
Note 4: Factory Settings are restored on next Power-Up/Reset of the NetCom. Factory Settings
are only effective on port 1 of the NetCom Server.
3.2 Signal Assignment
It is of course important to know the exact location of the serial signals in the configured mode.
Here is the table for the DB9 male connector. For RS 232 the assignment is the same as on any
PC (Com1/2).
Please note the GND signal in RS 422 and RS 485 modes. This signal must also be connected
between the serial devices. So in reality there is neither a 2-wire nor a 4-wire connection. With the
exception of very special configurations, a serial cable without GND violates the specifications for
RS 422 and RS 485.
3.2.1 Serial DB9 male
Pin
1
2
3
4
5
6
7
8
9
RS 232
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
RS 422/485 4-wire
Tx− (A)
Tx+ (B)
Rx+ (B)
Rx− (A)
GND
RS 485 2-wire
Data− (A)
Data+ (B)
GND
Figure 8: Connector DB9 male
Table 9: Signals DB9 male
January 2012
NetCom Lite User Manual
21
3
Hardware Description
3.2.2 Serial RJ45 to DB9 male
Pin RJ45
1
2
3
4
5
6
7
8
RS 232
RTS
DTR
GND
TxD
RxD
DCD
DSR
CTS
Pin DB9
7
4
5
3
2
1
6
8
Table 10: Signals DB9 male / RJ45 (NetCom 211)
Figure 9: Connector RJ45 and
DB9 male
3.2.3 Serial DB9 female
This type of serial connector is phased out. The current models are manufactured with DB9
male ports. For re-use of existing cables an optional Null-Modem adapter is available for RS 232
connections. Cables for RS 422/485 require special adapters.
Pin
1
2
3
4
5
6
7
8
9
RS 232
DCD
TxD
RxD
DSR
GND
DTR
CTS
RTS
RI
RS 422/485 4-wire
Rx− (A)
Rx+ (B)
Tx+ (B)
Tx− (A)
GND
RS 485 2-wire
Data+ (A)
Data− (B)
GND
Figure 10: Connector
female
DB9
Table 11: Signals DB9 female
3.3 RS 422/485 Electrical Configuration
In typical RS 422 and RS 485 installations certain electric conditions have to be configured. Simply
connecting cables is not enough to fulfill the specifications or RS 422 and RS 485.
For ease of installations the NetCom Lite Serial Device Servers provide the termination functions
for data lines. They are activated by placing certain jumpers, internal of the NetCom Lite. There
are two blocks of jumpers near each serial port, JP3 and JP10 in NetCom 111 / 113. Place a
connection cap to activate the function.
January 2012
NetCom Lite User Manual
22
3
Hardware Description
Pins
JP3: 1-2
JP3: 2-3
JP10: 1-2
JP10: 2-3
Function of Signals
Place 120Ω to terminate Tx±
(Data± in RS 485 2-wire)
Park position
Place 120Ω to terminate Rx±
Park position
Figure 11: RS 422/485
Option
Jumper
Table 12: RS 422/485 Jumper Configuration
Warning: All jumpers are in parking position by default. This is important for use in RS 232 mode.
Never activate termination, otherwise communication errors or damage of devices is possible.
3.3.1 Termination Resistors
The use of long communication lines in RS 422 and RS 485 mode requires the installation of termination resistors. These must match the impedance of the cable. Typical cables in Twisted-Pair
configuration have an impedance of about 120Ω. In RS 422 this resistor has to be placed at the far
end from the sender, in RS 485 the typical configuration requires one resistor at each end of the
cable.
3.4 Serial Port Simple Settings
There is one set of 4 (2) Dip switches to configure the operation mode of the NetCom Device. On
NetCom 413, 813 and 813RM there is a separate set for each serial port. Before connecting a serial
device, the serial port configuration must be completed.
Warning: a bad configuration may
cause serious damage in the NetCom or
the connected device. To avoid these
problems, it is recommended not to
connect a device to the serial ports in
the first installation. The serial ports
should be configured for RS 232. This
is done by setting the DIP switches like
this example.
Figure 12: DIP
Figure 13: DIP
Other
NetCom 211
NetCom
3.5 Network
The NetCom connects to Ethernet. The NetCom Servers do not perform a DHCP request when the
Ethernet interface becomes active. The connector for Ethernet is the usual RJ45. Simply connect
it to your (switching) Hub. A direct connect to your computer requires a cross-over cable.
When the connect is done the Link LED on NetCom (yellow) will light. When data traffic occurs
on the network, this LED will blink. It depends on your network whether a 100Mbit or a 10Mbit
connect will be established. A 100Mbit net causes the Speed LED on NetCom (green) to light,
otherwise it will remain dark.
January 2012
NetCom Lite User Manual
23
3
Hardware Description
Red LED
Off
On
On
On
On
On
Yellow LED
–
Off
On
Blink
On
Blink
Green LED
–
Off
Off
Off
On
On
Status
Device off, no power
No connection
10Mbit connection established
10Mbit data transfer (traffic)
100Mbit connection established
100Mbit data transfer (traffic)
Table 13: LED Function
3.6 Power Supply
The NetCom Lite device is powered by a single 9-30V power supply. It requires 200 mA up to
1500 mA of current, depending on the device type and voltage supplied. A suitable power supply
adapter is part of the packaging. Connect the cable to the power jack at the rear side of NetCom
Lite, and put the adapter into the socket. For the 19" rackmount devices of course just plug the
power cord into the socket. The Power LED on NetCom (red) will light.
You can connect a power supply of your choice, providing the technical requirements are met.
3.6.1 Round Power Jack
The round power jack requires positive voltage on the center
pin. The outer contact of the connector is negative, which is
connected to GND and the case.
Figure 14: Round Power Jack
3.6.2 Terminal Block Power
The Terminal Block power connector receives positive voltage on the right (V+) pin. The center (V-) pin connector is
negative, which is connected to GND and the case. GND is
the same as Field GND (FG), so the standard adapter does
not connect to this pin.
Figure 15: Power Terminal Block
3.6.3 AC Power Plug
AC power is provided by a standard cable. Protective Earth
connects to the case.
Figure 16: AC Power input
January 2012
NetCom Lite User Manual
24
3
Hardware Description
3.6.4 Power over Ethernet
Power is supplied via the network cable. As usual this connects to the Ethernet connector RJ45.
The implemented option follows IEEE 802.3af, which defines a maximum of 15 W as supply for
devices. According to this standard the NetCom is a Powered Device (PD), while the power is
brought to the cable by a Power Sourcing Equipment (PSE). Usually such a PSE is an enhanced
Ethernet switch, but also power inserters are available as PSE.
The NetCom 111 PoE, 113 PoE and 211 PoE consume less than 3 Watt of power, which qualifies
them as Class 1 (Very Low Power) devices. However to cover possible peaks in consumption they
are configured to identify as a Class 2 (Low Power, up to 6.5 W) PD. In most applications it is save
to configure a current limit as of Class 1 in the PSE.
January 2012
NetCom Lite User Manual
25
4
Windows Virtual COM Driver
4 Windows Virtual COM Driver
This chapter covers the use of NetCom Devices via Virtual Com Ports installed by the supplied
driver software for Windows. Sections 4.1 to 4.3 describe in details the process of driver installation
and removal, as well as updating. This first part here is for quick installation, so only the common
options are covered.
Section 4.4 provides the details of NetCom Manager and also the options available with the Virtual
Com Ports.
4.1 Installation Procedure
Before starting installation, it is essential to have an IP configuration ready for the NetCom Device
to install. You may read the TCP/IP Description (section 9) below. The default configuration is
based on DHCP, which is fine in many networks. If in doubt, please ask your Network Administrator
for help. Further it is assumed the network access is functional. It is recommended to use Ethernet
via Hub or Cross-Over cable for configuration.
The following description is based on Windows XP Professional, with Service Pack 2 installed. The
installation on other configurations of Windows is similar. The installation of drivers is described
first. This is followed by a procedure to verify a correct installation. The last part of this section
is about the uninstall or update processes of drivers and tools.
Drivers are provided for Windows NT, Windows 2000 up to Windows 7, Windows Server 2000 up to
2008 R2. The x86 and x64 Editions have separate drivers.
The drivers use the IP Address of NetCom Servers to operate. So the configuration
of the device should avoid to change that over time. This is either done via a static
IP Address, or by proper configuration of the DHCP server. In the second case
the DHCP server shall recognize the NetCom by its MAC Address, and assign the
same IP Address each time the device sends a request. All available DHCP Server
products provide such a function, even in SOHO routers.
4.1.1 Start the Installation Wizard
This is the Installation Wizard, it is named
VSNSETUP.EXEab . You’ll find it on the CD-ROM
shipped with the NetCom Lite, in the directory responsible for your operating system. The drivers are
also available on the Internet, in the latest version.
Start this program to install the drivers.
a
b
Figure 17: Installation Wizard
VSNSETUPA64.EXE in x64 Editions of Vista and Windows XP
VSNSTUNT.EXE in Windows NT
January 2012
NetCom Lite User Manual
26
4
Windows Virtual COM Driver
Figure 18: NetCom Driver Installation
The installation program offers three different ways of installation. The first option is the most
common used function, a Complete Installation. All driver files and tools are copied to the
Windows system, and installed in the Start Menu. Further the drivers are installed in the system,
and the network is searched for available NetCom. The serial ports on these devices are installed
as Virtual Com Ports in the system.
The second option will Install Tools and Drivers. However the network is not searched for NetCom Devices. And of course no serial ports are installed in the system. This function is designed
to prepare a computer for use of NetCom Virtual Com Ports, but the final installation shall be
skipped for some reasons. For example the computer shall be shipped to a customer, and the final
installation shall happen there.
Finally the third option is to Install Tools only, no drivers. At time of writing these tools are the
NetCom Manager, as well as the uninstall and repair functions. This function should be selected
when the use of Virtual Com Port drivers is not intended. The NetCom Devices may be used in
many different operation modes covered later (6).
There are also some Hyperlinks, opening access to more recent driver versions.
This part of the manual documents the Complete Installation, so click this option.
January 2012
NetCom Lite User Manual
27
4
Windows Virtual COM Driver
Figure 19: Start Driver Installation
A target folder for a file copy is requested. The tools and driver files are installed here. The tools
will appear in the Start Menu, so a sub-folder of your Program Files is suggested. Just click the
OK button.
Figure 20: Copy Driver Files
Some files are copied to your hard disk, this is the usual process similar to other Windows installations. The upper bar increases with the progress of each step performed in the installation process.
The lower bar illustrates each step performed until full installation is finished.
January 2012
NetCom Lite User Manual
28
4
Windows Virtual COM Driver
4.1.2 Find and Configure NetCom Devices
When all files are copied, the NetCom Manager1 program is started. This searches for all NetCom
Devices on your network.
Figure 21: Discover and Select NetCom Devices for Installation
After short time the search process is finished. All discovered NetCom are listed. In your very first installation
of NetCom Devices and Drivers you should connect only
one NetCom to your network. This single Device is listed
here. Identify it by comparing the serial number shown
in the NetCom Manager.
Figure 22: NetCom in Manager
4.1.2.1 Configure IP Parameters As mentioned above, it is important to configure the NetCom
to operate in your network. In many networks this is done by a special server (DHCP). Please ask
your Network Administrator for information. If you need to define parameters manually, doubleclick the devices icon.
1
This program is covered in detail in 4.4. For now follow the minimum steps.
January 2012
NetCom Lite User Manual
29
4
Windows Virtual COM Driver
Figure 23: Define NetComs IP Configuration
This panel opens. Deselect the Option of Use DHCP, and place your parameters as IP address,
Netmask and Broadcast. Click on the OK button. Since driver version 1.5.6 you may also enter a
DNS name instead of the IP Address.
Figure 24: DNS Name for NetCom Server
Click the DNS button, and enter the Qualified Domain Name defining the NetCom Server. Your
Administrator will provide you with it. This name is translated to an IP Address and used by the
driver.
When all parameters of the configuration are set, click the OK button. This will update the configuration of the NetCom , the new parameters are sent to the device.
January 2012
NetCom Lite User Manual
30
4
Windows Virtual COM Driver
Figure 25: Sending Parameters to a NetCom
4.1.2.2 Configure Firewall As you will notice in figure 23 the driver may also operate by traversal
of a Network Firewall. This requires a special configuration, which is skipped here. Please read in
detail in section 5.6 on page 52. For now proceed with the standard installation.
4.1.3 Install Drivers
You are now back in the NetCom Manager. Click the OK button, the installation continues. Windows detects the serial ports on the fresh NetCom as new Hardware. All new Virtual Com Ports
are installed without manual intervention by the user.
Figure 26: Virtual Com Ports installing
However using early driver versions or certain configurations of Windows, the system may request
certain actions by the user. You may be asked about to get latest drivers.
January 2012
NetCom Lite User Manual
31
4
Windows Virtual COM Driver
Figure 27: New Hardware Wizard
Automatic searching of Windows Update website will take quite a long time. So select the third
item, and click on Next. This question neither appears on Windows XP prior to SP2, nor on any
previous Windows version.
January 2012
NetCom Lite User Manual
32
4
Windows Virtual COM Driver
Figure 28: Install drivers for the serial ports
The pre-selected automatic installation is fine, just click on Next. The driver files are already copied
to your hard disk. Now Windows installs them in the system directory. To Finish the installation
click on that button as it appears. If the system can not detect the drivers, use the second option.
Add the folder as given in figure 19 to the search, then the system will detect suitable driver files.
These latest steps happen for each serial port on the NetCom Device. Just repeat the procedure,
until all ports are successfully installed. Windows will show you this. In most situations it is not
required to reboot the system. Of course you can do that now, to test the drivers.
4.2 Verify the Installation
In the Start Menu you’ll find the new program
group "VScom NetCom". The installed programs are the NetCom Manager, the Driver Repair program and an option for uninstallation.
This group is not installed on Windows NT.
Figure 29: VScom drivers in the Start Menu
January 2012
NetCom Lite User Manual
33
4
Windows Virtual COM Driver
Figure 30: NetCom in Device Manager
In the Device Manager the serial ports are listed in the
usual section Ports.
Additionally there is the device class
Multi-port serial adaptersa . All installed NetCom Devices are listed
herein. The available options are described later.
On Windows NT there is no Device Manager. You’ll find the serial ports
listed in the Control panel in the Ports applet. To configure the NetCom Figure 31: NetCom
Manager NT
and special port options, there is a new applet named NetCom Manager.
a
In drivers up to version 1.5.6 this was ’VScom Virtual Com’
4.3 Update the Drivers and Tools
As suggested by figure 43 the Installation Wizard offers an option to Update the drivers to a new
version. Windows itself also offers an option to update the drivers of installed devices. Although this
is a functional option, the correct operation of the NetCom drivers depends on a common version
for all drivers. The secure way to perform such an update is to run the Installation Wizard. All
driver files are replaced by later versions simultaneously, and all configuration data (Com number,
special port configurations, ...) is preserved.
Because several internal configurations of drivers have changed from version 1.5.6 to 1.5.8, the
option of Update is not available in this situation. The only way of update is to Uninstall the
current version, and install the new. Such a situation will be very rare.
4.4 Configuration of the Virtual COM Driver
If properly configured, the serial ports of the NetCom Devices appear as Virtual Com Ports in your
computer. The "virtual" means, in the computer is no real hardware related to the serial port,
January 2012
NetCom Lite User Manual
34
4
Windows Virtual COM Driver
however the driver offers the full functionality of a serial port to the system. The interface used by
the driver is VCOMM, which in turn is supported by the Windows API. So Windows does not see
a difference to Com1, and also no application should detect the change.
When the serial ports are installed by the Virtual Com driver software, any application may use
them. In the Device Manager they appear as NetCom COM Port (figure 30). Without special tests
a program does not see a difference between Com1 and the virtual Com7. For example the Hyper Terminal program has no problem to communicate through these Virtual Com. And this
situation is common amongst most programs.
4.4.1 Configure the Serial Ports
A typical application selects a serial port, and opens it. After that it performs the standard
configuration of bits per character, parity settings and number of stop bits. Also the flow control
(handshaking) is defined by the application. Windows sends these requests to the port driver, and
this driver sends the requests to the serial port on the NetCom.
Figure 32: NetCom COM Port Serial Settings
The same parameters may be pre-configured in the Device Manager. This is done via the
Properties of the NetCom COM Port. In the Local Settings tab these standard parameters are
defined. Since most programs configure these parameters by themselves, the values are very rarely
used. A typical situation is a serial printer attached to this virtual port.
January 2012
NetCom Lite User Manual
35
4
Windows Virtual COM Driver
As usual this behaves different in Windows NT. There is no Device Manager. To change these
standard parameters, open the Ports applet in the Control Panel. However it is suggested you
open the new NetCom Manager applet instead. Change to the Ports view as in figure 38. Doubleclick on the small icon at the left side. In this dialog go to the Local Settings tab, as seen
above.
4.4.2 Performance Issues
Operation through the network causes some extra time, which is approximately 5 Milliseconds. For
comparison, with a port internal to the computer this time may be just some 100 Microseconds.
This added time has an impact on reaction times. Some data protocols may be sensible. A lot
of configurations are possible to compensate for this. But these have an effect on the sheer data
throughput of the virtual serial port.
Figure 33: NetCom COM Port Performance Settings
Consequently the configuration starts on the Performance tab. There are four already defined sets
of parameters.
Best Performance is the default configuration. The driver software and
the NetCom communicate with big data blocks. As a result a
reaction on short events on the serial port is somehow delayed.
For applications operating with short data blocks, and waiting
January 2012
NetCom Lite User Manual
36
4
Windows Virtual COM Driver
for short answers this is not optimal. It causes transmission
delays, called Latency.
Good Performance uses smaller blocks. The Latency may be reduced a
little bit, depending on the application. But the impact on the
data throughput is small.
Short Latency mimics a 16C550 with full FIFO enabled, but no network
timeouts will occur. This means the block size is 16, quite
small for network operations.
Virtual FIFO Off simulates a deactivated FIFO, which is the fastest setting in terms of latency. The port is configured as if the FIFO
is off, buffers are configured to never wait for a timeout, hence
gaining in best reaction times. The FIFO buffers are not deactivated in reality, they are still used to prevent data loss.
Driver Defaults returns to the standard settings when enabled.
Advanced opens access to detailed configuration of the operation parameters.
January 2012
NetCom Lite User Manual
37
4
Windows Virtual COM Driver
4.4.3 Network & Misc Properties
When you use the Advanced checkbox on the Performance tab, the Network/Misc tab opens
automatically.
Figure 34: NetCom COM Port Network/Misc Properties
The parameters on this tab control the operation of the driver software on the computer.
Tx Network Buffer Size: If the application sends small chunks of data to
the driver, these are buffered to send them in one large packet.
This parameter defines the size of the buffer. And also the
maximum packet size sent to the serial port by the driver software.
Rx Network Buffer Size: This is the size of the buffer to receive data from
the NetCom.
Automatic Trigger: based on internal rules, this checkbox selects a best
practice value for Tx Trigger Level. Deactivate it to control
that parameter manually.
Tx Trigger Level: Controls the time when data is sent to the NetCom.
If the Tx buffer holds at least this amount of data, the driver
January 2012
NetCom Lite User Manual
38
4
Windows Virtual COM Driver
immediately sends them. If there is less data, the driver may
use a timeout to determine when to send them.
Network Timeout (ms): This is the timeout.
Overspeed: This is a special option, not really related to network communication. There are old applications, limited in the maximum
speed. With Overspeed you define a multiplier. The baudrate
requested by the application is multiplied with this factor. The
result is sent to the NetCom to configure the serial port. E.g.
the application may be limited to 38,400 bps, but there is a
modem capable of 230,400 bps on the serial port. Set Overspeed to a value of 6.000, and configure the application to use
38,400 bps.
Open If Absent: The NetCom may be used from a computer with a DialUp connection. When this option is used, the driver will delay
the connection to NetComs serial port. Even when an application opens the port and configures the parameters, no command is sent. The connection is established when data is sent
to the NetCom, or when status information is requested.
Keep Alive: This option will periodically send control information to the
NetCom to check if the connection is still operational. As a
second effect a Dial-Up connection will not automatically close.
Passive Modem: This option controls how often the driver retrieves Modem
status information from the NetCom. If activated, the driver
never asks for the modem status. Instead the NetCom informs
the driver of any changes. If an application frequently requests
the Modem status, it gets the last value received. On slow
networks like the Internet this option is recommended.
If inactive, the driver software retrieves the Modem status from
the NetCom serial port each time the application requests it,
but with a maximum frequency of 10 per second. If the latest
retrieved information is not older than 100 milliseconds, this
value is returned.
Simulate Device Off on Connection Loss: When this option is enabled,
the NetCom driver does not attempt to preserve transmitted data. If on a normal serial port the connected device is
switched off, all data sent to this device gets lost. NetCom
simulates this behavior. All data sent from the application to
the driver is discarded, when the TCP connection to the NetCom is lost. The NetCom driver attempts to re-establish the
connection in regular intervals. When the NetCom is available
again, data may be transferred from then on.
January 2012
NetCom Lite User Manual
39
4
Windows Virtual COM Driver
4.4.4 Remote Settings Properties
The other panel created by activating the Advanced checkbox on the Performance tab, is the
Remote Settings tab.
Figure 35: NetCom COM Port Remote Settings Properties
The parameters on this tab control the operation of the serial port on the NetCom Device. They
are defined and activated by the driver software.
Tx Trigger Level: The serial port on the NetCom Device buffers data for
transmission to external devices. If the amount of data in this
buffer drops below this level, the NetCom is capable to receive
new data. It will send a related event to the driver software.
Rx Trigger Level: When the serial port has received this amount of data,
these are sent to the driver on the connected computer. If
the amount is less than this, the NetCom applies a timeout of
about 5 character times. This means the timeout varies with
the serial transmission speed.
The Remote Flow Control panel signals the NetCom to perform the handshake on its own. This is
necessary, because the network delay of some milliseconds is to long for reliable operation in many
situations.
January 2012
NetCom Lite User Manual
40
4
Windows Virtual COM Driver
Enable:
The configuration shown here is active, when the pre-defined
performance levels are used. When using the ‘Advanced’ option, Remote Flow Control is completely disabled. Enable as
required. While it is best practice to configure as figure 35,
you can disable certain events here.
CTS, DSR, Tx XON/XOFF: these control the output of data to the serial port.
RTS, DTR, Rx XON/XOFF: used to stop transmission from the connected device.
An application has the option to use any combination of these methods at the same time. The
command to use them is transferred to the NetCom. For example, if the port is configured to
use Hardware Flow Control, the NetCom will control the RTS line, and observe the CTS line.
If requested, any of these methods may be unchecked. In that case the driver software on the
computer will control the lines.
Override App Settings: In rare situations it is necessary to ignore the
applications configuration. Check this box, and select the Flow
Control functions to use with the device.
Limits:
These buttons are prepared for future software versions.
January 2012
NetCom Lite User Manual
41
4
Windows Virtual COM Driver
4.4.5 Installation of NetCom Servers
This section of the manual covers the correct installation of the drivers and serial ports. Please
do a quick review of the section 4.1, before reading further. As of the time of writing, the current
driver is version 1.5.12.0
Figure 36: Select NetCom to install
The NetCom Manager program is started by the Installation Wizard. Often there are more than
only one NetCom listed. And sometimes not all of them are to be used on this specific computer.
The Exclude button is used for that purpose. Select a NetCom Device,
and click on that button. The driver will later ignore this NetCom,
when installing and operating the serial ports. The Icon changes to
olive color.
In figure 36 above you’ll notice yellow questions marks at each icon.
These appear when the NetCom is not already installed for the Virtual Figure 37: Excluded
NetCom
Com driver. It may also appear, if you open NetCom Manager without
administrative privileges. If the mark changes to a red exclamation
mark, the NetCom is non functional. It may be without power, the network may be broken, or the
device is completely removed. Or the NetCom Manager is still without administrative privileges.
To clear the display in NetCom Manager just select that NetCom and use the Remove button.
January 2012
NetCom Lite User Manual
42
4
Windows Virtual COM Driver
If a NetCom has not been operational when the Manager program was started, it is either displayed
with the exclamation mark, or not displayed at all. You may make it operational by connecting it
now. To install it, use the button Search to find it in the network. Or Add it manually with that
button (section 5.6).
Figure 38: NetCom Manager Ports View
Similarly you may exclude certain ports on a specific NetCom Server from installation as a Virtual
Com port.
These are the special options used while installing the driver software. At any time after installation
the configuration may be changed by the NetCom Manager program. This may result in serial ports
appearing in or vanishing from the system.
4.4.5.1 Changing the Installation There are common situations, when the current configuration
needs a change. In the first case the NetCom has been moved to a different location, or the logical
structure of the network has changed. It may happen the IP Address of NetCom is also changed.
Either by Automatic (DHCP), or manually via a different interface like the Web browser. Because
of the changed address the driver does not find the serial port to contact.
Figure 39: Reconfigured NetCom found
Now open the NetCom Manager. It will re-detect the devices. In this process the Manager finds the
already installed NetCom, but with a new configuration. Then the Manager requests interaction
from the user. This question here assumes the NetCom shall be installed from scratch. This will
produce a Com port with a new number. If just a reconfiguration has occurred, click on No. When
January 2012
NetCom Lite User Manual
43
4
Windows Virtual COM Driver
you do that, the parameters of the installed Virtual Com Port are changed to contact the same
serial ports on a new network address.
Figure 40: Replaced NetCom found
The second case occurs, when a NetCom is replaced by another device. This new device shall have
the same configuration, especially the same IP Address. When you start the NetCom Manager, it
will detect a new device with parameters already in the database. So a similar question appears.
An installation of a new serial port is assumed again. If the device shall replace the old one, click
on the No button.
In general the driver software and the NetCom Manager identify the NetCom Devices by the
combination of IP Address and serial number. If one of these is changed, the above requests
appear.
4.5 Uninstall the Drivers and Tools
To completely uninstall the NetCom Drivers and files, there are three methods. The usual way
is to use the Add/Remove Programs applet in the Control Panel, and remove the NetCom Drivers.
This will start the NetCom uninstallation program.
Figure 41: Uninstall NetCom Drivers via Control Panel
January 2012
NetCom Lite User Manual
44
4
Windows Virtual COM Driver
As a second way you may start the Uninstall
program in the start menu. The third method
is to start the Installation Wizard again from
CD-ROM or the installation directory.
The Wizard will detect the drivers on the system. You have the options to Repair the current installation, or to Remove the installed Figure 42: Uninstall NetCom Drivers in Start
Menu
drivers. Since the Installation Wizard is of the
same version as the installed drivers, the option
of Update is not available.
Figure 43: Remove, Repair
A Repair replaces the driver files on the system with those in the installation package. Since this
is the same versions, the files should also be the same. If anything is damaged in the installed
drivers, the Repair process will correct the problems.
As expected the Remove process will uninstall drivers and tools from the system. The drivers are
removed from the configuration and also completely deleted from the System drive. This happens
with any configuration data also. Afterward the system is available for a clean installation.
January 2012
NetCom Lite User Manual
45
5
Configure with NetCom Manager
5 Configure with NetCom Manager
Shipped with the NetCom Devices there is a versatile program for Windows Operating System,
named NetCom Manager. This program shall detect, manage and configure the NetCom Devices
in your network. You can start it by several ways. First of all it is stored on the CD-ROM, named
NETCOMMGR.EXE23 . It is possible to start it directly from the CD-ROM.
See this Icon. When the Virtual Com Drivers are installed, there are
more options to run the program. In Windows NT the same Icon appears
in the Control Panel, to start the NetCom Manager program.
Also the process of installing the drivers created a new program group
in the Start Menu.
Figure 44: NetCom
Manager
This section of documentation focuses on management of the NetCom
Devices. The options to configure driver-specific parameters of the serial
ports are skipped here. This includes some buttons and panels. They
are described in total in section 4.4, in the documentation of the drivers and panels.
While in the configuration process, a click on
a button or a double-click on an item opens
properties or other options. In many situations,
a right-click with the mouse opens contextsensitive options. Just try it out. The NetCom
Manager is designed to help configure driver opFigure 45: NetCom Manager in Start Menu
tions. So for very detailed configuration of a
NetCom, it is better to use the Web browser
interface, or do it via Telnet as described in section 6. Here are the options.
2
3
NETCOMMGRA64.EXE in x64 Editions of Windows
NETCOMMGRNT.EXE on Windows NT
January 2012
NetCom Lite User Manual
46
5
Configure with NetCom Manager
5.1 Starting NetCom Manager
When NetCom Manager is started, it will ‘Search’ the NetCom in your LAN by SNMP. This process
may take up to 30 seconds. The devices in a LAN are typically found in the first seconds. If this
is enough for you, you can stop the search by click on the ‘Done’ button.
Figure 46: NetCom Manager Servers Panel
The NetCom are listed here in the Servers panel. Since the Search uses broadcast mechanisms,
the range is limited. If you have Routers in your network, or you contact some NetCom via Internet,
you must Add them manually (section 5.6). Enter the network parameters to access the NetCom.
Select a NetCom, and click on the Properties button, double-click the Icon, or use a right click.
Using Verify the NetCom Manager contacts the NetCom to check if it is properly configured
and online. Exclude is only useful in conjunction with the Virtual Com Drivers, so skipped here.
Search repeats the search from the program start, and may be used at any time. Remove removes
a NetCom server from this list. This option is most often used to clear old data from the drivers
database. For monitoring purposes you may select a NetCom, and Start Log for this. It may be
done for several Devices at the same time. The output is visible in the Log Windows panel.
January 2012
NetCom Lite User Manual
47
5
Configure with NetCom Manager
5.2 NetCom Server Settings – Info
As described above, open the Properties of a NetCom Device. The Server Settings start with the
Info panel. Configure the options as your network requires.
Figure 47: NetCom Manager Server Settings - Info
The Server Name is just for information. As factory setting it includes the serial number of the
device. You may change it to any string (of ASCII characters), since there is no functionality related
to the name. This name is listed in the Server panel of NetCom Manager. The next parameters
are fixed, and displayed for information only.
The Telnet port allows to configure this NetCom via Telnet. The value is a TCP port number.
Factory setting is 23, the standard port for Telnet protocol. By default the NetCom is set to
Use DHCP for automatic configuration of IP parameters. This is the suggested method. However
there are several situations where this option can not be used. In this case deactivate it. When
inactive, other parameters may be changed. The basic parameters IP address and Netmask are
mandatory. Instead of an IP Address you may enter a DNS name. The NetCom Manager will resolve
that name to the actual IP Address.
If address or netmask are changed, the NetCom Manager calculates a matching address for
Broadcast. You may also change this address. The DHCP option will also configure the
Default gateway and the Name server. Without DHCP you must enter these parameters by yourself, enter 0.0.0.0 if they are not used.
January 2012
NetCom Lite User Manual
48
5
Configure with NetCom Manager
5.3 NetCom Server Settings – Ports
The Ports panel lists all serial ports of a NetCom. Some of the options are driver related, e.g. the
Com Number. Each serial port may operate via two TCP ports.
Figure 48: NetCom Manager Server Settings - Ports
The TCP Control Port is used in the Virtual Com Driver mode, and also in Null-Modem Tunnel.
If Driver mode is not desired, this parameter is ignored almost always.
The TCP Data Port is used to transmit data to and from the serial port. Use the default, or change
the value to the settings required for your network.
There is also a UDP Data Port, used in packet data transfer. You can not switch the NetCom to UDP
mode with the Manager. But if it is already in this mode, you can change this basic parameter.
January 2012
NetCom Lite User Manual
49
5
Configure with NetCom Manager
5.4 NetCom Server Settings – Firewall
Many networks use a Firewall to protect the stations in the network from other networks, including
the Internet. In some situations the contact to a NetCom must pass through such a Firewall
configured for NAT (Network Address Translation, section 11).
Figure 49: NetCom Manager Server Settings - Firewall
To do this you must Enable Firewall, and enter the Address of the Firewall. The address may
be the IP Address, or the Qualified Domain Name (DNS).
The Manager configures a NetCom via SNMP, which uses UDP. The Firewall must have a special
Port to receive those data, and to transfer it to the internal network. Enter this port here.
The same scheme applies to the logging option. When logging is active a NetCom listens on
port 1200 for logging connections. The Firewall must also have a special Log Port to receive this
connection, and to transfer it to the NetCom.
The NetCom does not need any configuration to operate in a Firewall protected environment. This
configuration here is for installation of the drivers. There is a Firewall tutorial section later in this
manual (5.7).
January 2012
NetCom Lite User Manual
50
5
Configure with NetCom Manager
5.5 NetCom Server Settings – Options
Figure 50: NetCom Manager Server Settings - Options
This Panel is available since software version 1.4.8.0, in this enhanced version. A Safe to File of
the configuration is available, as well as the opposing Load from File of this data.
You can also Reboot the NetCom. This may be useful, e.g. if an old connection blocks access to
the NetCom.
The button Apply Changes commits all parameter settings done so far to the NetCom. And the
Verify checks the current settings by reloading the status from the NetCom to the Manager
program.
When you want to install a Firmware Update, use this button. But it may be more easy to do this
via the web interface of the NetCom.
The NetCom may be protected for access, in this case you must place the current Server Password
in the dialog. The option to change the password is reserved for a future extension. Exclude Server
is related to the Driver installation only.
You may Enable Log to see events at the NetCom, for monitoring. If enabled, the log will also
appear in the central Log Window. At any time it’s possible to Clear the log, or Capture the data
to a file.
January 2012
NetCom Lite User Manual
51
5
Configure with NetCom Manager
5.6 Manual Detection/Installation of a NetCom
Sometimes the NetCom Device Server can not be detected by the automatic in the NetCom Manager. To detect and configure devices the protocol SNMP is used. The detection is done by sending
out a broadcast on all available network interfaces of your computer. This SNMP broadcast is realized as an Ethernet broadcast. Such a broadcast is only transmitted through Hubs and Switches.
When there is a Router between the computer and the NetCom, probably the broadcast is not
transmitted further. This is especially the situation when the NetCom is located somewhere via
Internet, but also in big networks of some companies. If this is the case, the detection has to be
done manually. Refer to figure 36 and Add the NetCom by use of the button. Enter the IP Address
of the NetCom in the NetCom Manager Server Settings, and click the button Verify. Since now
the IP Address of the NetCom is known, the NetCom Manager sends a request directly to this
target, instead of a broadcast. This directed SNMP request is transported, even by Routers. The
NetCom sends the normal reply, giving all required information to the NetCom Manager. Now it
is possible to configure all options as usual. Also the drivers for virtual serial ports are installable
now.
Please note, the drivers require to have the IP Address. They can not operate using a DNS name,
because the driver can not perform a DNS name resolution. If your NetCom is located on a dynamic
IP Address (e.g. on a Dial-Up connection with 24 hours disconnection), you need to reconfigure
the driver installation, when the IP Address has changed. There is a NetCom Helper Service5.8 for
assistance.
5.7 Firewall Traversal Configuration
There are more difficult situations with a Firewall between the NetCom and the NetCom Manager. Many Firewalls protect the internal LAN by using the feature of NAT (Network Address
Translation, 11). In this situation the IP Address of the internal device is not visible on the Internet. Only the Firewall can be contacted via its public IP Address. The NetCom Manager and
the driver software for the virtual serial ports can handle such setups. But this requires certain
configurations.
5.7.1 SOHO Firewall example
The most easy situation for such a setup is by using a very simple SOHO Router as the Firewall. This configuration will show the principle of the technical details. Those principles can be
transferred very easy to the configuration of more complicated installations.
On the SOHO Router there is only one public IP Address on the external side, and typically 254
internal private IP Addresses for the LAN side. These internal addresses may be assigned by DHCP
or static. Such Routers offer a feature typically named "DMZ", which in fact is only a single exposed
host. It is recommended not to use the "DMZ" for several reasons, some of them are security related.
Especially it is recommended not to configure a NetCom as the DMZ host.
January 2012
NetCom Lite User Manual
52
5
Configure with NetCom Manager
5.7.2 SOHO Virtual Servers
The Router also offers "Virtual Servers" (here named ViServ for short), which is the option required
for NetCom installation. These ViServ operate by a technique called PAT (Port Address Translation, 11). Certain data addressed to the public IP Address of the Router are forwarded to the
internal private address of the NetCom. This way the NetCom can be contacted via the public
IP Address of the Router.
First you need to configure the Router for some ViServs. As the absolute minimum there is one
ViServ for the NetCom device itself, and another two ViServs for each serial port of the NetCom.
Those ViServs are to be configured for TCP or UDP transmissions. Please read in the manual of
your Router how to do that. You need a port for the external interface, and an IP Address plus a
port for the LAN side. The LAN IP Address is of course that of the NetCom. As an example the
most easy device is a NetCom 113 PRO. The internal port for SNMP is 161 for UDP. The serial
port requires ports 2000 and 2001 for TCP.
Function
SNMP
Control
Data
External port
8161/UDP
9000/TCP
9001/TCP
Internal port
161/UDP
2000/TCP
2001/TCP
Table 14: SOHO Firewall Pass-Through
Configure your Router for these example ViServs, and use the internal IP Address of the NetCom
for the targets. Connect the NetCom to your LAN. Now you are ready for a very first test. Use
Telnet to connect to the Data port of the NetCom serial port. Open a console (DOS Box) and
type the command
Telnet <Routers-IP-Address> 9001
You will be connected to the serial port. Every character you type is sent out of the serial port,
and every received data is shown on your screen. The serial parameters are pre-configured in your
NetCom.
5.7.3 NetCom Detection through SOHO Firewall
Now open the NetCom Manager as in section 5.6 above, and click the Add button. You again get the
NetCom Manager Server Settings dialog. But now you have to select the panel named Firewall
(see figure 49).
Check the Option Enable Firewall, and enter the IP Address of the Router in the Address field. In
the field Port enter the target port for the SNMP configuration. From the Virtual Server example
above this is port 8161. Since there is no configured ViServ for Logging, ignore this field. Click
the button Verify to have the NetCom Manager contact the Router. This is a directed request,
so there is no problem with broadcasts. The Router will transfer the request to UDP-Port 161 on
the NetCom, which is the port for SNMP. The NetCom will answer the request, and send it out to
your computer. The NAT function in the Router will replace the source IP of the data by its own
public value, so the NetCom Manager will see the answer come from the Router. The NetCom
Manager is satisfied with this data.
January 2012
NetCom Lite User Manual
53
5
Configure with NetCom Manager
Some ISP will block the SNMP protocol, which typically means they do not transport data for
161/udp to their customers (this is the first reason why port 8161 was used in the example).
This answer brings every required information about the NetCom, including its internal IP Address.
Select the panel of NetCom Manager Server Settings to verify the information, but do not make any
changes here. Changing the configuration may disconnect the NetCom from the protected LAN.
5.7.4 Serial Ports through SOHO Firewall
Now the NetCom is available in the NetCom Manager, but still the serial ports are not usable.
The information of the TCP-ports for the ViServ related to the serial port is still missing. In the
NetCom Manager Server Settings select the NetCom Manager Ports Panel. In this panel select one
serial port, in this example of NetCom 113 PRO there is only one serial port. Click the Properties
button to open the configuration of the port.
Figure 51: NetCom Manager Port Configuration for Driver
Since the Firewall function is enabled, the parameters for Firewall mapping are available for
editing. Enter the ports defined in the Router, 9001 and 9000 in this example. Please note, so
far there is no number for the Virtual Com Port available. The driver is not installed in this
moment, and Windows does not know about the available hardware. This will happen later in the
installation. Click the OK button, and proceed with the driver installation as already described.
January 2012
NetCom Lite User Manual
54
5
Configure with NetCom Manager
5.7.5 DMZ and Virtual Servers
Why is it recommended not to use the DMZ function of the Router? There are two reasons. The
first one is simple, only one device in the LAN can be defined as the DMZ target. The DMZ is
implemented as "Send all IP data targeted for the Router to the DMZ station, as long as there is
no specific rule for a different target". When a second NetCom shall be installed on the LAN, the
Virtual Servers have to be configured anyway.
The second reason is the security. Using the “DMZ” option the Firewall in the Router becomes
transparent. All data from outside is transferred to the LAN, including all malicious data. In
general this is not an especially smart idea.
5.8 NetCom Helper Service
In certain situations users of VScom NetCom Serial Device Servers come to the problem of dynamic
IP Addresses. This typically happens when the NetCom is used over Internet, using an ADSL or
cable Modem connection. At certain times (e.g. every 24 hours) the NetCom is disconnected from
the Internet. When it is re-connected, it will receive a new IP Address, which is different than
before.
The NetCom Driver for Windows installs the serial ports on the NetCom Servers as virtual local
Com Ports in the system. They are seen in the Device Manager, and standard applications like
Hyper Terminal have a seamless access to the connected serial devices. To perform this task the
driver uses the IP Address of the NetCom Server. On the established TCP connections the driver
exchanges serial data, commands and status information.
When the IP Address of the NetCom has changed, the driver attempts to contact the old IP Address,
which will fail. So the virtual Com Port is not usable any longer. Up to driver version 1.5.5 users
have to use the NetCom Manager to reconfigure the driver.
Since the driver version 1.5.6 there are more options. The software installs a so-called Helper
Service on the system. This service monitors the configured NetCom Servers, and detects the
changed IP Address. The driver is reconfigured to use the new IP Address, so the port is usable
again. This all happens without specific user interaction.
5.8.1 Configure Helper Service
The NetCom Helper Service is configured via NetCom Manager. There is a new Register card. In
the upper part users Enable the Helper Service, and they also configure the Polling Period (i.e.
frequency). If the Helper Service is disabled, it is also stopped in the system; it does not consume
any system resources. Of course it does not provide any help when disabled. The Polling Period
is given in seconds. When the interval has passed, the configuration of the NetCom Servers is
checked.
January 2012
NetCom Lite User Manual
55
5
Configure with NetCom Manager
Figure 52: NetCom Helper Service
The lower part in the new panel lists all NetCom Servers available in the system configuration. The
user must decide which of those shall be monitored (Enable). At the regular intervals as configured
above the NetCom Server is checked. The Helper Service attempts to connect to the NetCom Server,
and verifies the parameters. If the verification fails, the Service uses several methods to find and
identify the NetCom Server.
5.8.2 Detection and Priority
The NetCom Helper Service has two basic methods to detect and identify a NetCom Server.
The first method is the broadcast search on the network, the new method is DNS based. The
DNS method has two variants, with or without firewall configuration. The reasons for changing
IP Addresses or the methods to use are discussed later.
5.8.2.1 Broadcast Search The method of broadcast search is the same method as used in the
NetCom Manager. A broadcast request is sent to the local network, and the NetCom Servers reply
to this. The NetCom Manager lists them for configuration.
This method is used by the NetCom Helper Service also. A NetCom Server is identified by MACAddress and Serial Number. These two parameters are fixed, customers can not change them. If a
NetCom Server is found with a changed IP Address, the driver configuration is updated.
5.8.2.2 DNS based Search In driver versions up to 1.5.5 the NetCom Server has been configured
by its IP Address. This is still the standard situation in later driver versions. However the Info
Panel of Server Properties is modified (see figure 47). You may enter a Qualified Domain Name
instead of the IP Address.
Figure 53: Enter Qualified Domain Name
The name is resolved, i.e. translated to the current IP Address associated with the name. This
IP Address is configured in the driver, and the DNS name is also saved there.
January 2012
NetCom Lite User Manual
56
5
Configure with NetCom Manager
In a local company network this may not be an especially useful option. But when the NetCom
Server is used via the Internet, this is the standard situation for most applications.
DNS is used when the NetCom is not a part of the local network broadcast domain. As a consequence it is not detectable via the broadcast method described above. Provided there is a reliable
DNS service available, now it is more easy to install a NetCom in the system. Please read about
the Manual Detection/Installation of a NetCom in section 5.6.
The NetCom Helper Service regularly checks if the NetCom Server is still available on the known
IP Address. If the attempt for contact fails, the Helper Service uses DNS to find the new IP Address
of the NetCom Server. This new IP Address is used for future operation.
5.8.2.3 DNS based Firewall Configuration The NetCom Servers do not manage an Internet
Connection on their own. But it is possible to have a NetCom Server on a public IP Address,
when the Internet Connection is managed by Routers. More often the NetCom Server connects to
a private LAN, and has a private IP Address. The Internet Connection is managed by a Router,
which also acts as a Firewall. This Router uses NAT/PAT to make the NetCom Server available
via Internet. Please read about this in section 5.7.
When the Firewall Configuration is activated for access to the NetCom, it has been possible to
enter the DNS name of the NetCom Server in previous versions of the driver. Precisely it was the
DNS name of the Router. This name has been resolved at the time of configuration, and has been
stored for later use. Now the NetCom Helper Service monitors the DNS name to connect to the
NetCom Server. If the connect fails, the DNS name is resolved again. The new result is used in
the driver. The driver can again contact the firewall to get access to the NetCom and the serial
ports.
5.8.3 Changed IP Address
There are several configurations with changed or regularly changing IP Addresses. This is a rough
overview.
5.8.3.1 Broadcast Domain The broadcast domain is part of a local network. In typical SOHO
networks the domain covers the entire network. The broadcast domain is typically limited by
Routers. Broadcasts are transmitted between computer and NetCom Server, if there are only
Switches/Hubs or WLAN Access Points on the way between those two.
Usually the IP Addresses in a local network are static. This is also the situation when there is a
DHCP server, and all clients use this. If the server is configured properly, it will provide the same
IP Address to a certain station again and again. It does so, because the stations are identified by
their unique MAC-Address.
A changed IP Address may occur because the network is re-organized, combined with a reconfiguration of the DHCP server. In most cases however it is simply because the station has been switched
off for a comparably long time. So the DHCP server forgot about the station, and provided the
IP Address to a different target.
January 2012
NetCom Lite User Manual
57
5
Configure with NetCom Manager
5.8.3.2 Internal DNS If the company network becomes larger, it will also use some Routers. For
organization the network is grouped in subnets. As mentioned above, typically the broadcasts are
blocked by Routers, so the broadcasts only cover a single subnet. To contact stations in other
subnets the IP Address of the target is required. Usually this is provided by a DNS server. This
server may co-operate with a DHCP server.
A usual cause for a changed IP Address in the NetCom Server is a connection to a different subnet.
It will have a different IP Address there, but the DNS server should know about the new address.
5.8.3.3 Internet Some ISP disconnect the customers stations from the Internet in regular intervals, e.g. every 24 hours. If the station is configured for immediate re-connect, it will get a new
IP Address. This station can notify a Dynamic DNS service, so this will resolve to the new address.
This is typically combined with a SOHO Firewall/Router.
5.8.4 Polling Period
The last matter to check about is a suitable Polling Period for the NetCom Helper Service. The
standard value is 3600 seconds, i.e. one hour. With this configuration a change in the address is
noticed up to 60 minutes later. When the change occurs just before the Helper Service checks the
connect, it will be recognized very soon, if the check happens just after the change, it will require
the maximum time.
Usually an installation requires to have changes detected very soon, but this is not possible on
networks. The NetCom Server has no feature to contact all clients, and notify them of a changed
configuration. This is because the NetCom Server can not manage a possibly huge list of client
computers.
So the Helper Service is installed on the client computers. If there are a lot of clients, very frequent
polls cause a high load. For one side on the network, but most important on the NetCom Server.
The best choice for a suitable polling interval depends on the usage period of the client computer.
If it is unused for some hours per day (over night), it will detect a change at least the next morning.
Provided the change happens over night.
If the NetCom Server uses an Internet connection with regular disconnects, it is a good idea to
configure those disconnects to times of inactivity of the clients.
For manual detection of changes it is possible to restart the NetCom Helper Service. Controlling
a service requires administrative privileges on the Windows system. A restricted user account can
not do this. Restricted users use the Polling Period configured by the system Administrator.
January 2012
NetCom Lite User Manual
58
6
Configure the Operation Modes
6 Configure the Operation Modes
The NetCom Devices are often used without the installation of a driver software. Customer applications contact the NetCom directly, using network functions. These setups require independent
configuration of the NetCom Device and the serial ports. There are five ways to do this configuration. The NetCom offers a Web browser interface, configuration via serial port, via Telnet and also
via SNMP. This SNMP option is not covered in this manual, please see separate documentation.
The NetCom Manager program for Windows is already explained above.
The access to the NetCom via web interface or Telnet are done via a TCP/IP connection between
the computer and the NetCom. So users need the IP Address of the NetCom. The most easy way
to retrieve this information is the NetCom Manager program (section 5). Start it, and open the
Info Panel (figure 47) of the NetCom Server you want to configure. This panel displays the current
IP Address of the NetCom. Do not change the parameters, just write down the value.
The default configuration of a NetCom is for use of a DHCP server. When such is not available,
the IP Address defaults to 192.168.254.254. When the IP Address of the NetCom is not in final
state, leave the NetCom Manager open while doing the first configuration of the NetCom Server.
But in general the software may be closed as soon as the IP Address is known.
6.1 Accessing the Configurations
Here the manual shortly explains the different methods to get access on the parameters of a NetCom.
These parameters are the same, independent from the method for configuration. So the options
are described later.
The configuration is accessible via web browser, a Telnet software with VT100/VT52 emulation,
or via a Terminal emulation connected to the first serial port of the NetCom .
6.1.1 Web Browser Configuration
Open your favorite web browser, and enter the IP Address as the target location. To avoid any
confusion you should precede it with http://, so your browser has definite target information. Most
browser programs do not need that. Your browser must not suppress images.
If the NetCom is password protected, you must enter this now. Leave the user name empty, just
type the password.
January 2012
NetCom Lite User Manual
59
6
Configure the Operation Modes
Figure 54: Configuration Menu in Web Browser
The NetCom welcomes you with its "Home" screen. To access the different options of configuration,
the images above function as a link. In many menus you’ll see a blue question mark. This is a
symbol for help. When clicked a short explanation pops up, informing about the function of this
parameter. Some other settings require a reboot to save and activate them. Whenever this situation
occurs, the NetCom requests a REBOOT.
Figure 55: Request to Reboot in Web Browser
It is done like this here, you may reboot then, or do that later when the configuration is finished.
6.1.2 Telnet Configuration
Start your Telnet software with the IP Address of the NetCom as the parameter. In most configurations you use the standard port for Telnet, so you omit this parameter. As an example this is
the command-line in Windows, which you may enter in Start⇒Run, or in a console (DOS box).
C:\Windows\System32>Telnet 192.168.254.254 23
January 2012
NetCom Lite User Manual
60
6
Configure the Operation Modes
For completeness the port is shown in this command. Enter the configured parameter when the
port is different. If the NetCom is password protected, you need to enter the password right now.
Please enter your password:
Figure 56: Password Request in Telnet
When connected to NetCom you must define the type of terminal used. Most Telnet software
includes an emulation of a VT100 terminal, so choose this option. Also choose this option for an
ANSI emulation.
Please choose your terminal type (1:VT100 2:VT52 [1]): 1
Figure 57: Select Terminal Type in Telnet
The configuration with Telnet is menu-driven.
+------------------------ NetCom - 123 WLAN V2.4.1 ----------------------------+
|
ServerConfig
SerialPorts
Tools
Save&Exit
|
+------------------------------------------------------------------------------+
+--------------------------------------------------------------------- h=HELP -+
Server configuration settings
Figure 58: Main Menu of Configuration Console in Telnet
This is the start point for configuration. ServerConfig has all options to configure the NetCom
device itself, including the IP-Parameters to access it. SerialPorts defines settings related to the
serial port. Tools has some utilities like PING or displays statistics. In Exit you may leave the
menu or reboot the NetCom . At any time you can get a short hint by typing "H" for help.
January 2012
NetCom Lite User Manual
61
6
Configure the Operation Modes
Use the cursor keys to select the parameter you want to change. Hit <Enter> to edit them. Type
the new value, or select provided options. Use <Esc> to leave a parameter or menu. Please check
the configuration of your Telnet, if there are any problems.
6.1.3 Serial Configuration
In some situations it may be impossible to get network access to the NetCom Device. If this happens
(e.g. by an accidentally misconfiguration), neither Telnet, nor the web interface is functional. It
may be even impossible to use the NetCom Manager program.
In this case you must connect to the NetCom via the serial port. Disconnect any serial cable from
NetCom. Set the DIP Switches to "RS 232 Configuration" (all switches to Off, section 3.1). Then
connect the NetCom with your computer using a Null Modem cable. If your NetCom is an old
model with a connector DB9 female, attach the supplied Null-Modem Adapter to the port first. Or
connect your computer to the female connector with a straight-through cable.
Open any serial terminal program (Hyper Terminal, minicom, PuTTY4 , . . . ), select 38400 bps,
8 Bit, No Parity as configuration. Set your terminal to emulate a VT100 (recommended, but VT52
is also possible), including the Arrow keys.
Then power on the NetCom. When connected to NetCom you must define the type of terminal
used (VT100 or VT52), and optionally provide the password. This is the same configuration option
as described above at 6.1.2, so follow the instructions for Telnet.
When the configuration is done, change the DIP Switches back to normal operation. Later configurations can be done by web interface or Telnet. Of course this requires to have a functional
IP configuration defined.
6.2 NetCom Configuration Options
Some of the menus are very long, especially on the web interface. These are divided in their
logical sections throughout this document. Each section shortly mentions the way to access the
parameters. Short screen shots show the typical display when configuring the NetCom. Usually
the web interface is shown on top, and the terminal interface (Telnet, serial port) is shown below;
a horizontal line divides the two. On few occasions the two screen shots are displayed side by side,
with the web interface to the left and the terminal interface to the right; then divided by a vertical
bar.
6.2.1 Server Configuration
In your web browser click on the Icon of “SERVER CONFIGURATION”, the browser opens the
basic server information, the server parameters related to the IP-configuration, the parameters for
Wireless communication, the section for encrypted communication, Password settings, and finally
the configuration for date and time.
In Telnet the ServerConfig offers the IP parameters, Wireless and encrypted configuration, Password settings, configuration for date and time, as well as basic server information.
4
Download PuTTY from putty.org
January 2012
NetCom Lite User Manual
62
6
Configure the Operation Modes
6.2.1.1 Server Info
Web: menu “SERVER CONFIGURATION”, section “Server Info”.
Telnet: “ServerConfig”, option “Info”
ServerConfig
+--------------------+
| Parameter
|
| Wireless
|
| OpenVPN
|
| Authentification |
| Date & Time
|
| Info
|
Server Info
Server Type
Software Version
Hardware Version
Serial Nr.
423 WLAN
2.4.1
1.0
0010100454
UpTime
3 day(s) 02:10:17
+--------------------+
Contact
[<unset> ]
Location
[<unset> ]
Figure 59: Server Information
Information about the selected NetCom is displayed as “Server Info”. Starting with the
Server Type, this is the model of the NetCom , followed by the Software Version and
Hardware Version. This will give a rough overview, which features are implemented, or need an
upgrade of the firmware. The Serial Nr. is important to identify the device you are configuring
right now. For further information the UpTime is listed.
Contact and Location are user-defined information. They may later help to find the device in the
installation, and the person responsible for management. The Administrator may provide some
contact information here.
Contact defines a person to contact for help, e.g. "Mrs. Jane Doe, 555-HELP". Location is
the physical place of the NetCom, e.g. "CeBIT Hall 12, Service Box IX.a". These data are
restricted to ASCII characters.
January 2012
NetCom Lite User Manual
63
6
Configure the Operation Modes
6.2.1.2 Server Parameter
Web: menu “SERVER CONFIGURATION”, section “Server Parameter”.
Telnet: “ServerConfig”, option “Parameter”
The Server Parameter allow configuration of the NetComs name and of course all parameters
in IP-settings. The Server Name is used as general information, e.g. in the NetCom Manager
program.
ServerConfig
+--------------------+
| Parameter
|
| Authentification |
| Date & Time
|
| Info
|
+--------------------+
Server Parameter
Server Name
MAC Address
DHCP
IP Address
Netmask
Broadcast
Gateway
DNS
Domain
ConfigPort
PrintServerPort
KeepAlive
[NetCom_0051100021
00:04:D9:80:00:14
Enabled
192.168.1.65
255.255.255.0
192.168.1.255
192.168.1.1
192.168.1.3
visionsystems.de
[23
]
[515 ]
Off
KeepAliveInterval
[0
]
]
Figure 60: Server Parameter
January 2012
NetCom Lite User Manual
64
6
Configure the Operation Modes
Manual changes of IP parameters are only available with DHCP set as Disabled. When DHCP is
not used, enter IP Address and Netmask, as well as the Broadcast address. Gateway is required, if
there are Routers in the network. DNS is used to access other stations by name. The ConfigPort is
used to access the NetCom for administration via Telnet. It is suggested to use the standard value
for Telnet, TCP port number 23. However it may be changed for different purposes. This does not
change the function of the Telnet menus.
Firmware version 2.2 introduces the new function as Print Server. The TCP Port defined by
RFC1194 (mostly referred to as »Line Printer Daemon«) is 515, under certain circumstances you
may change the PrintServerPort. More about Print Server function at the configuration of the
serial ports ( 6.2.2.2.8 on page 79).
KeepAlive is an intrinsic function of the TCP/IP protocol. If used it causes network traffic,
but problems are detected earlier. In a LAN this is usually not a problem. However, if used
via Dial-Up connections this may cause problems. If this functions is On, you must define an
KeepAliveInterval in seconds. NetCom has a better chance to react on network problems, or
failed hosts. Even dropping an old connection may be useful in certain environments.
6.2.1.3 Authentication
Web: menu “SERVER CONFIGURATION”, section “Authentication”.
Telnet: “ServerConfig”, option “Authentication”
ServerConfig
+--------------------+
| Parameter
|
| Authentification |
| Date & Time
|
| Info
|
Security Settings
Password
[empty]
+--------------------+
Figure 61: Access Authentification
The Security Settings define a Password to restrict access to the configuration of NetCom. The
password is not shown while typing it. To protect against accidental mistyping, you must type the
Password twice.
6.2.1.4 Date & Time
Web: menu “SERVER CONFIGURATION”, section “Date and Time Settings”.
Telnet: “ServerConfig”, option “Date & Time”
It may be helpful to have a correct time setting in the NetCom. You may manually enter the time
here. Please note, there is no real time clock with a battery backup in the NetCom. When the
NetCom is restarted, the time is lost. Retype the value of Date & Time for manual setting. The
format is DD-MM-YYYY HH:MM:SS UTC+/-TZ (Time Zone).
January 2012
NetCom Lite User Manual
65
6
Configure the Operation Modes
ServerConfig
+--------------------+
| Parameter
|
| Authentification |
| Date & Time
|
| Info
|
+--------------------+
Date and Time Settings
Date & Time
[01-01-1970 00:17:33 UTC+0]
Simple Network Time Protocol
State
Mode
Interval
Off
DHCP
[1800 ]
Server
[ ]
Figure 62: Date & Time Retrieval Options
It is possible to configure NetCom for automatic time retrieval via SNTP.
The State field has three possible settings:
• Off: disables automatic time retrieval.
• Startup: NetCom gets the time at reset or power on.
• Interval: NetCom repeats to retrieve time.
The parameter Mode is used to find the definition of the Time Server. It may be defined direct, or
by DHCP5 .
The Interval in seconds instructs the NetCom to regularly check for an update of the internal time
settings. The Time Server may be given by IP Address or by name. A name of course requires a
configured DNS server6 .
6.2.1.5 Save
Web: menu “SERVER CONFIGURATION”, at bottom.
At the bottom of the web page below all the options there is the button Save. This will store all
configurations done here in the NetCom. Selecting a different configuration section from the menu
5
6
DHCP has to be active in the Server Parameter 6.2.1.2
see at Server Parameter 6.2.1.2
January 2012
NetCom Lite User Manual
66
6
Configure the Operation Modes
may discard all changes done. For many configuration changes the NetCom requires a reboot to
proceed, especially if the IP parameters have been updated.
The Telnet section has a separate menu for saving configurations, described later.
6.2.2 Serial Port Configuration
In your web browser click on the Icon of “SERIAL CONFIGURATION”. This is a huge menu in
the web browser. Each serial port of the NetCom is listed in a separate Column. A maximum of
four serial ports is shown. Select the appropriate group of ports.
Figure 63: Port Page Selection in Web Browser
The top half of the parameters titled “Serial Settings” is directly related to common serial configurations. The bottom half titled “Transfer Settings” configures the operation mode of NetCom on
the network. Each serial port is configured separately, there is no setting shared between ports.
In the Telnet menu select “SerialPorts” in the Main Menu, and directly select the serial port to
configure.
The settings available in this menu are by port. Therefore, first the port to configure has to be
chosen.
SerialPorts
+----------+
| Port 1 |
| Port 2 |
| Port 3 |
| Port 4 |
SerialPorts
+---------------------+
| Serial Settings
|
| Transfer Settings |
+---------------------+
+----------+
Figure 64: Port Selection in Telnet
Just select the port by placing the cursor, and then press <Enter>. The next option is to configure
the Serial Settings or the Transfer Settings.
January 2012
NetCom Lite User Manual
67
6
Configure the Operation Modes
6.2.2.1 Serial Settings
Web: menu “SERIAL CONFIGURATION”, column “Port N”, “Serial Settings”.
Telnet: “SerialPorts”, select “Port N”, “Serial Settings”
Some NetCom devices allow to operate in RS422/485 modes. This is configured by the DIP switches
associated with the port, PortType (current) displays the current setting.
Serial Settings
Port Nr.
PortType (current)
DefaultModel
MaxBaudrate
Model
Baudrate
Manual
FlowType
DataBit
Parity
StopBit
RxFifoLength
RxTriggerLevel
TxFifoLength
1
rs232
16550
921600
16550
38400
110
None
8
None
1
2048
[1248 ]
2048
TxTriggerLevel
[800 ]
Figure 65: Serial Settings
The serial ports are based on 16C550A UARTs, the Model and maximum speed are also displayed.
The current UART Model may be virtually changed to a less advanced type. In some situations it
may be desirable to deactivate the FIFO memory, or some other options.
January 2012
NetCom Lite User Manual
68
6
Configure the Operation Modes
When the NetCom is used via the Virtual Com Driver mode, the following serial parameters are
controlled by the application which opened the serial port. However certain installations use a
different operation without Driver mode. Then the serial parameters must be defined via this
configuration section.
The Baudrate may be selected in a drop-down list of common values, or entered manually. If
Manual is selected in the list, the value in the respective field is used to transmit data. NetCom
checks if the configuration is possible, and warns otherwise. DataBit per character, Parity and
StopBit are quite usual parameters. The FlowType is available as standard configuration. But
there is also the option of Advanced Configuration.
FlowType Configuration
Port Nr.
AutoCTS
AutoRTS
AutoDSR
AutoDTR
AutoTxXOnXOff
1
off
off
off
off
off
AutoRxXOnXOff
off
Figure 66: Advanced Flow Control
This gives very specific control to the user. NetCom can generate Events on RTS, DTR or as
XON/XOFF, when the serial receive buffer is filled/emptied. These will inform the connected
device to stop or continue the transmission. The NetCom will also respect the state of CTS, DSR
or XON/XOFF when sending data to the connected serial device.
The RxTriggerLevel defines when NetCom sends the received data to the host. If the amount of
data is this high, the data is sent. It does not matter if there is still data coming on the serial line.
If less data is received, the NetCom waits some time for further data, before sending the buffer.
When this parameter is reduced to ‘1’ obviously all data is sent right when it has been received.
The TxTriggerLevel operates similar for the transmission. If the defined amount is received from
the network, the NetCom does not accept more data to transmit. These options reduce latency
times, by increasing the network traffic.
January 2012
NetCom Lite User Manual
69
6
Configure the Operation Modes
6.2.2.2 Transfer Settings
Web: menu “SERIAL CONFIGURATION”, column “Port N”, “Transfer Settings”.
Telnet: “SerialPorts”, select “Port N”, “Transfer Settings”
The Transfer Settings allow different operation modes. They are selected by the basic Mode setting. Depending on the current mode, only some of the many parameters are useful. The web
configuration hides those parameters without function.
SerialPorts
+---------------------+
| Serial Settings
|
| Transfer Settings |
Transfer Settings
Port Nr.
Mode
+---------------------+
1
+---------------------------+
| Driver Mode
|
| Null Modem Tunnel
|
| TCP Raw Server
|
| TCP Raw Client
|
| TCP Advanced Settings
|
| UDP Mode
|
| IP Modem
|
| Print Server
|
| Point to Point Protocol |
+---------------------------+
Figure 67: Serial Port Mode Selection
The following paragraphs explain these operation modes as well as their parameters and configuration in detail.
6.2.2.2.1 Driver Mode Only very few parameters have a function in Driver Mode. NetCom is
operating as a Server in TCP mode, it accepts two connections per serial port. This mode is
required when the driver software for Virtual Com Ports shall be used.
January 2012
NetCom Lite User Manual
70
6
Configure the Operation Modes
Mode
Driver Mode
TCP Port(Control)
TCP Port(Data)
[2000 ]
[2001 ]
KeepAliveMode
On Connect
KeepAliveInterval
[0
]
Figure 68: Driver Mode parameters
The first connection is used to transmit the serial data, this is the TCP Port(Data). And the other
is used to transmit control information, TCP Port(Control). This control connection includes the
configuration of the serial port, as well as signals for changed Modem Status lines. This mode is
required when the serial port is operated via the Virtual Com Driver, it is the default.
In Driver Mode the NetCom accepts only one client per serial port. An attempt to connect a
second client is actively refused. This is required to avoid confused configurations and data on the
serial port.
The NetCom can monitor an open connection. This is controlled by the KeepAliveMode, which
has three settings: Off, On Connect and Polling.
• Off: never send KeepAlive packets.
• On Connect: when a client is trying to connect to the server and
there was a connection before, the server checks if the first connection
still exists. If it does not exist anymore, the server accepts the new
connection.
This option is the default configuration.
• Polling: the server checks in KeepAliveInterval (seconds), if a
connection still exists.
If the network connection between client and NetCom seems to be unstable, the configuration of
Polling may be desired. This way the NetCom may detect when the connection got lost. When
the NetCom detects a lost connection, this is discarded, so the NetCom is available for other clients.
Disabling the check is not recommended.
6.2.2.2.2 TCP Raw Server As Raw Server the NetCom operates very simple. It only waits for
incoming data connections in Raw IP mode. In contrast to the Driver Mode no driver software
needs to be installed on client computers, this mode operates directly on the TCP/IP stack in
January 2012
NetCom Lite User Manual
71
6
Configure the Operation Modes
the operating system. The parameters of the serial port are defined on the NetCom, as given
above (3.1).
Mode
Raw Server
TCP Port(Control)
Max.Clients
[2000 ]
[1 ]
Password
[******]
Figure 69: TCP Raw Server parameters
Compared to the Driver Mode only the data connection is defined by the TCP Port(Data). The
Max.Clients parameter allows for more than one connection to the NetCom at a time. If the
number is raised, it is the responsibility of the customer to ensure correct operation. There is no
special Keep Alive option, the global parameters from section 6.2.1.2 apply.
Firmware version 2.2 added the option of additional protection by Password. When a password is
configured, the NetCom sends the question "Password: " to the client. The user (his application)
must first send the password, followed by a <CR> character. The password is not echoed to allow
usage with Telnet on a Monitor.
6.2.2.2.3 TCP Raw Client Also as Raw Client the NetCom requires very few parameters. The
client computer operates via the TCP/IP stack as in 6.2.2.2.2, but now this computers waits for
incoming connections opened by the NetCom. Using this mode several NetCom may connect to
the same server software installation. The parameters of the serial port are defined on the NetCom,
as given above (3.1). When the client computer is another NetCom in TCP Raw Server mode, this
will virtually connect the devices attached to the serial port.
January 2012
NetCom Lite User Manual
72
6
Configure the Operation Modes
Mode
Raw Client
Destination
Connect
[192.168.1.5:2001 ]
Triggered
ShortHoldTime
[0
]
Figure 70: TCP Raw Client parameters
Under certain conditions the NetCom establishes a Raw TCP connection to a pre-defined
Destination. Since version 2.0 of the NetCom Firmware the Destination can hold multiple hosts as
targets for a connection. They are entered as a comma separated list of DNS names or IP Addresses.
Each destination will have a TCP port number, separated by a colon. Instead of a single IP Address
or DNS name, a range of IP Addresses is also valid. This range must be followed by the TCP port
number, as in 192.168.254.12-192.168.254.17:2077.
The parameter Connect defines if NetCom uses the connections as Permanent, Triggered or by
DSR. With Permanent the NetCom attempts to open the connection as soon as it is available. In
Triggered mode any activity on the serial ports establishes the connection, inactivity of longer
than the ShortHoldTime cause NetCom to close the connection. With DSR the TCP-connections
follow the state of the DSR signal at the NetCom serial port. When it becomes active they are
established, until DSR becomes inactive. At that moment the connections are dropped.
6.2.2.2.4 Null Modem Tunnel This operation mode is intended to build a long virtual Null
Modem Cable between the serial ports of two NetCom. This mode is symmetric, both NetCom
operate as server and as client at the same time. The parameters of the serial port are defined on
the NetCom, as given above (3.1).
January 2012
NetCom Lite User Manual
73
6
Configure the Operation Modes
Mode
Null Modem Tunnel
Server
TCP Port(Control)
TCP Port(Data)
[2000 ]
[2001 ]
Client
Destination
TCP Port(Control)
TCP Port(Data)
Connect
ShortHoldTime
[
[2000 ]
[2001 ]
Triggered
[0
]
KeepAliveMode
On Connect
KeepAliveInterval
[0
]
]
Figure 71: Null Modem Tunnel
This is a mixed mode, requiring parameters for server function and for the client part. The NetCom
operates as a server while accepting connections in Driver Mode (6.2.2.2.1). If there is no current
connection, the NetCom may establish a connection as a client. This is also a special connection,
using the Driver Mode protocol. NetCom will not only transmit serial data in both directions, it
will also pass information about the current settings of the Modem Status lines. And it will itself
set the Modem Control lines as required by the other host. The CTS is connected to the RTS of
the partner, and DSR connects to DTR. Since this operation requires another NetCom to accept
the connection, both NetCom together operate as a long Null-Modem cable. The data is sent via
a tunnel through the network.
The configuration as Server (top part) requires the same parameters as the Driver Mode, hence
TCP Port(Control) and TCP Port(Data). Also the KeepAlive function operates the same.
The configuration as Client (bottom) first requires a destination. Here it is given by name, but a
direct IP Address may be more usual. On the destination there is also a TCP Port(Control) and
TCP Port(Data) to accept the connect of the NetCom.
January 2012
NetCom Lite User Manual
74
6
Configure the Operation Modes
The Connect methods are the same as with the TCP Raw Client mode. So connections to the
partners are permanent, last until there is no activity for a given time, or they are controlled by
the DSR signal.
Attention: You must not configure both NetCom with a Connect option configured as Permanent.
This will result in each of them attempting to contact the other at the same time. Both NetCom
will reject the connect, because they are already busy establishing a connect of their own. Instead
create an asymmetric configuration: either use one of the NetCom in Driver Mode, or configure it
with an empty Destination parameter. Or consider to have a connection on demand, i.e. use the
Triggered option.
6.2.2.2.5 TCP Advanced Settings All of the above operation modes are special configurations
for options. In some situations none of the pre-defined modes fit the customers needs. When this
is the case, the TCP Advanced Settings offer the configuration of any Transfer parameter. Unusual
combinations of Modes are possible with this, also standard modes with unusual parameters.
January 2012
NetCom Lite User Manual
75
6
Configure the Operation Modes
Transfer Settings
Port Nr.
Mode
1
TCP Advanced Settings
Server
TCP Port(Control)
TCP Port(Data)
Max.Clients
On
[2000 ]
[2001 ]
[1 ]
Client
Destination
TCP Port(Control)
TCP Port(Data)
Connect
ShortHoldTime
Off
[
[2000 ]
[2001 ]
Triggered
[0
]
KeepAliveMode
On Connect
KeepAliveInterval
[0
]
]
Figure 72: TCP Advanced Settings
The NetCom usually acts as a network server. This means it accepts incoming connections. The
most used Driver Mode is one example. The NetCom detects which mode to use. When the
Data-Port is opened first, then the NetCom operates in TCP Raw Server mode, with respect to
Max.Client. When the Control-Port is opened first, the NetCom expects a second connection on
the Data port, to operate in Driver Mode for one client only.
The NetCom can also operate as a network client as seen in TCP Raw Client mode. This is enabled by setting Client to On. As a client it requires the same parameter as for the specialized
modes. When the TCP Port(Control) is defined (not zero), the NetCom will operate as a client
for Driver Mode, as in Null Modem Tunnel. The destination is the target address or DNS name.
January 2012
NetCom Lite User Manual
76
6
Configure the Operation Modes
Otherwise the NetCom operates in TCP Raw Client mode when it establishes a connection. The
syntax for multiple destinations applies then.
The remaining parameters are explained in the client mode descriptions.
The TCP Advanced Settings allow for flexible usage of the NetCom, when Server and Client
modes are On at the same time. If no connection is active with the NetCom, it accepts incoming
connections, i.e. it operates as server as long as the connections are held. Without a connection a
Trigger event defined in Connect cause the NetCom to establish a connection to the defined target.
So the NetCom is a client at that time.
6.2.2.2.6 UDP Data Transfer UDP is an Internet Protocol, which does not define a connection,
it sends data in single packets instead of a stream. There is no extra return data to signal a
successful transmission. As a side effect data may be sent and received faster than with TCP/IP.
The UDP mode is available as a function since the version 1.4 of the NetCom firmware.
Mode
UDP Mode
UDP Port(Local)
Destination
UDP Port(Dest)
UDP MaxPacketSize
UDP Timeout
[2002
[
[2002
[1458
[0
UDP Trigger
[
]
]
]
]
]
]
Figure 73: UDP Data Transfer
This protocol requires a UDP Port(local) for listening to incoming data. Other stations on the
network send their data to this port. The Destination host is configured by IP Address or name,
plus the target UDP Port(Dest). Please compare with the parameters for TCP Raw Server and
Client Modes. The parameters to configure the UDP Mode are similar to a mixture of these modes.
A UDP Broadcast is sent, if the destination address is the broadcast Address, see section 6.2.1.2
above.
Since there is no connection, data can not be sent in a stream. UDP uses packages. There are
several ways to define the content for a package.
January 2012
NetCom Lite User Manual
77
6
Configure the Operation Modes
UDP MaxPacketSize is a limit for the size of UDP packets. When the
amount of data received on the serial port reaches this limit,
the UDP Frame is assembled and sent to the destination.
UDP Timeout defines when the NetCom sends the received data as a UDP
Frame. If the reception of serial data is interrupted for this
time (in milliseconds), the data sampled so far is sent to the
destination. A value of zero causes all data to be sent immediately, use “-1” to disable the function of timeout trigger.
UDP Trigger defines a sequence of characters. As soon as this sequence is
detected in the received data, all data up to the end of this
Trigger is sent to the destination. In most situations such
a Trigger includes control or other special characters. Enter
them numeric: as \xHH where HH is the hexadecadic code of
the character, or as \OOO where OOO is the octal code of the
character. The backslash itself must be doubled as \\.
6.2.2.2.7 IP-Modem The serial port of a NetCom may mimic (emulate) a serial modem. There
is the separate section 7 defining this functionality. Here are the basic network parameters only.
Mode
IP Modem
TCP Port(Data)
Destination
[2001 ]
[
]
IP Modem Config
[
]
Figure 74: IP-Modem
A serial modem accepts connections from a phone line, while an IP Modem accepts connections
from the network, in this case via TCP/IP. The TCP port for this is defined as the TCP Port(Data),
similar to TCP Raw Server mode. This is the only parameter required to set here.
All other values are normally defined by AT-commands via the serial port. However for short,
Destination allows for up to four predefined targets, available with special Dial commands. The
IP Modem Config is known as the Init String in standard modems.
January 2012
NetCom Lite User Manual
78
6
Configure the Operation Modes
6.2.2.2.8 Print Server Function The NetCom firmware version 2.2 introduces the function as a
Print Server according to RFC1179, also called a »Line printer daemon«. A print server is accessed
through its IP Address via one specified TCP Port (see section 6.2.1.2). Data is handled in distinct
queues, each with a certain name. Each queue is handled by a certain serial port, and the data is
sent to the serial printer attached to this port.
Port Nr.
Mode
QueueName
1
Print Server
[lpd1
]
InitString
[
]
Figure 75: Print Server Configuration
Each serial port configured for Print Server operation has its separate QueueName. The default
value is »lpd« plus port number. The InitString is a special feature of NetCom. This string
is sent to the serial printer at the beginning of the next queued print job. The definition is in
section 8.2.1 on page 99.
January 2012
NetCom Lite User Manual
79
6
Configure the Operation Modes
6.2.2.3 Save
Web: menu “SERIAL CONFIGURATION”, at bottom.
Again at the bottom of the web page below all the serial port options there is the button Save.
This will store all configurations done for the current group of serial ports. Selecting a different
group of ports or another configuration section from the menu may discard all changes done.
6.2.3 NetCom Tools
Several tools for system status, checks and debugging are available in the Firmware. The available
tools are:
• The Ping utility to check if a station is available.
• Statistic information for each serial port.
• The Netstat utility to monitor used TCP connections.
• The option to update the firmware.
• Saving of Configuration to / Loading from a file (web browser only).
• Information logging by Syslog function and a DebugLog via TCP/IP.
In your web browser click on the Icon of “TOOLS”, the browser opens the list of available tools.
In Telnet the “Tools” menu provides a list of the tools.
January 2012
NetCom Lite User Manual
80
6
Configure the Operation Modes
6.2.3.1 Ping
Web: menu “Tools”, section “Ping”.
Telnet: “Tools”, option “Ping”.
Enter the IP Address or the name of a station in the field. In the web browser click the Ping
button, hit the <Enter>-key via Telnet. The network connection is checked by sending ICMP
Echo Request data packages.
PING 127.0.0.1 from 192.168.1.87 : 44 (72) bytes of data
52 bytes from 127.0.0.1: icmp_seq=0 ttl=255 time=1.560 msec
52 bytes from 127.0.0.1: icmp_seq=0 ttl=255 time=1.542 msec
52 bytes from 127.0.0.1: icmp_seq=0 ttl=255 time=1.542 msec
back
Figure 76: Ping and Response in Web Browser
Tools
+-------------+
| Ping
|
| Statistic |
| Netstat
|
| Wireless
|
| Logging
|
| Firmware
|
IP-Address to ping to: [127.0.0.1
]
+-------------+
PING 127.0.0.1 from 192.168.1.243 : 44 (72) bytes of data.
52 bytes from 127.0.0.1: icmp_seq=0 ttl=64 time=< 10 ms
52 bytes from 127.0.0.1: icmp_seq=1 ttl=64 time=< 10 ms
52 bytes from 127.0.0.1: icmp_seq=2 ttl=64 time=< 10 ms
52 bytes from 127.0.0.1: icmp_seq=3 ttl=64 time=< 10 ms
Figure 77: Ping and Response in Telnet
If the target responds, the network between the NetCom and the target is operational. The time
required for an echo depends on the speed of the network. In a typical Ethernet this is only very
few Milliseconds, while it can be several seconds throughout the Internet.
Via Telnet use the <Esc>-key to stop the Ping function.
6.2.3.2 Statistics
Web: menu “Tools”, section “Statistics”.
Telnet: “Tools”, option “Statistics”.
January 2012
NetCom Lite User Manual
81
6
Configure the Operation Modes
The Statistics are presented on a by-port base. So you first select the serial port, and then you get
the information about modem status and control. Also the amount of data transferred is shown.
Tools
+-------------+
| Ping
|
| Statistic |
| Netstat
|
| Wireless
|
| Logging
|
| Firmware
|
Tools
+----------+
| Port 1 |
| Port 2 |
| Port 3 |
| Port 4 |
+----------+
+-------------+
Figure 78: Statistics Port Selection
Line Status
DTR
DSR
RTS
CTS
DCD
RI
off
off
off
off
off
off
(0)
(0)
(0)
(0)
(0)
(0)
Common
Serial Tx
Serial Rx
0
0
Figure 79: Port Statistics
The statistics window7 reports the state of the modem status and control signals. Further the
NetCom counts the number of status changes on the modem control- and status-signals, since the
NetCom has been started. The number of characters sent and received is shown at the bottom.
6.2.3.3 Netstat
Web: menu “Tools”, section “Netstat”.
Telnet: “Tools”, option “Netstat”.
Netstat is a common tool to display the actual status of network connections. It may be used to
monitor the actual status of the NetCom. This is a standard tool for network debugging.
7
The web browser opens a separate window for each port selected
January 2012
NetCom Lite User Manual
82
6
Configure the Operation Modes
Tools
+-------------+
| Ping
|
| Statistic |
| Netstat
|
| Wireless
|
| Logging
|
| Firmware
|
+-------------+
Figure 80: Start Netstat
Update
Proto
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
udp
udp
Local Address
0.0.0.0:23
0.0.0.0:80
0.0.0.0:2000
0.0.0.0:2001
0.0.0.0:2010
0.0.0.0:2011
0.0.0.0:2020
0.0.0.0:2021
0.0.0.0:2030
0.0.0.0:2031
192.168.1.243:80
192.168.1.243:80
0.0.0.0:161
0.0.0.0:19970
udp
192.168.1.243:32331
Foreign Address
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
192.168.1.42:1280
192.168.1.42:1281
State
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
TIMEWAIT
ESTABLISHED
1/1
Proto
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
tcp
udp
udp
Local Address
0.0.0.0:23
0.0.0.0:80
0.0.0.0:2000
0.0.0.0:2001
0.0.0.0:2010
0.0.0.0:2011
0.0.0.0:2020
0.0.0.0:2021
0.0.0.0:2030
0.0.0.0:2031
192.168.1.98:23
0.0.0.0:161
0.0.0.0:33320
udp
192.168.1.98:10397
Foreign Address
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
0.0.0.0:0
192.168.1.42:3665
State
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
LISTEN
ESTABLISHED
Figure 81: Netstat Sample Output
A ‘Foreign Address’ of “0.0.0.0” is listed when NetCom is waiting for an incoming connection
(LISTEN mode). If the value is not “0.0.0.0”, the connection is either active (ESTABLISHED) or
already closed (TIMEWAIT).
In the web browser you may Update the Netstat output.
Via Telnet the output may not fit on the screen, then the display will start with “1/2" in the first
line. Or even more for a long list. You may change to a different page by using the Page Up/Down
January 2012
NetCom Lite User Manual
83
6
Configure the Operation Modes
keys in your Telnet. The display is refreshed in an interval of some seconds. Use <Esc>-key to
return to the menu.
January 2012
NetCom Lite User Manual
84
6
Configure the Operation Modes
6.2.3.4 Firmware
Web: menu “Tools”, section “FirmwareUpdate”.
Telnet: “Tools”, option “Firmware”.
To upload a new version of the firmware, put the name of the file in the field. Your web browser
will allow to search for the file. Click on the Update button, and your browser will upload the file
to the NetCom.
Tools
+-------------+
| Ping
|
| Statistic |
| Netstat
|
| Wireless
|
| Logging
|
| Firmware |
Firmware Update
Update Port
[
[2400 ]
Start Update
]
+-------------+
Figure 82: Firmware Upload
Via Telnet the option to upgrade the Firmware of NetCom is different. The upload of the data
is either done via the current channel (i.e. the serial or Telnet connection). Or independently via
a separate TCP/IP connection. The Update Port parameter defines this second connection, the
NetCom waits for a TCP connection on this port. The Firmware is sent coded in base64 (a special
text format), via very simple programs like a second Telnet session, or similar tools. Terminal
software by serial configuration may just use the “Send Textfile” function.
While uploading the file it is checked by NetCom. If it is a valid content, it is stored in the Flash
Memory. When the upload is finished, NetCom will Reboot.
6.2.3.5 Save and Load Configuration
Web: menu “Tools”, section “Configuration File”.
Via web browser it is possible to save the actual configuration to a text file. Of course it is also
possible to load the saved configuration into a NetCom.
January 2012
NetCom Lite User Manual
85
6
Configure the Operation Modes
Figure 83: Save and Load Configuration in Web Browser
This may be very useful when configuring several NetCom of the same type. Configure one device,
and save the file. Change the configuration file for the necessary parameters, and upload the
modified version to the next model.
6.2.3.6 Logging and Debug
Web: menu “Tools”, section “Syslogging”.
Telnet: “Tools”, option “Logging”.
The NetCom has two options of Logging. There is the standard Syslog, and a second option of
logging via Telnet.
Tools
+-------------+
| Ping
|
| Statistic |
| Netstat
|
| Wireless
|
| Logging
|
| Firmware
|
+-------------+
Logging
Syslog
Destination
Facility
Off
[
[1
Debuglog
Off
Debug Port
[0
]
]
]
Figure 84: Syslog & Debuglog Parameters
The Syslog function may of course be Off or On. In the On-state the NetCom sends all the log
information to a computer defined by Destination. A special software often called Syslog Daemon
January 2012
NetCom Lite User Manual
86
6
Configure the Operation Modes
has to receive these data. The Option of Facility is a criteria for the Daemon how this will
organize the data received from the NetCom.
In contrast for Debuglog the NetCom behaves as the server. When this option is On the NetCom
waits for incoming TCP connections to the configured Debug Port. The NetCom sends all logging
information via this connection. For manual use a software like Telnet is suitable, especially if it
has the option to save all received data.
6.2.3.7 Save
Web: menu “Tools”, at bottom.
As usual at the bottom of the web page below all the options there is the button Save. This will
store the configurations done for Logging (6.2.3.6).
6.2.4 Reboot
Web: menu “REBOOT”.
In your web browser, click the Icon of REBOOT to restart the NetCom firmware.
Attention: This option will discard all configuration changes, unless they have explicitly been saved.
Naturally it will also disconnect all other clients using serial ports or the Telnet configuration
menu.
6.2.5 Save&Exit Menu
This section of configuration is only available via the terminal interface, i.e. via Telnet or serial
port. Modifications in the configuration of the NetCom are not active, until they are explicitly
saved to the Flash Memory of NetCom. This menu also allows to discard all changes, and even to
restart the firmware.
6.2.5.1 Save Parameter
Telnet: “Save&Exit”, option “Save Parameter”.
When some changes are done, these modified settings should be saved. A confirmation is requested
before doing this.
Save&Exit
+------------------+
| Save Parameter |
| Exit
|
| Reboot
|
+---------------------------------+
| Do you want to save the changes |
|
Yes
No
|
+---------------------------------+
+------------------+
Figure 85: Menu Save modified Parameters in Telnet
The Telnet interface is still active when this operation is finished.
January 2012
NetCom Lite User Manual
87
6
Configure the Operation Modes
6.2.5.2 Exit
Telnet: “Save&Exit”, option “Exit”.
You will not be surprised, when you leave the menu by selecting this option. If you made any
changes of parameters, you must confirm to save these.
Save&Exit
+------------------+
| Save Parameter |
| Exit
|
| Reboot
|
+---------------------------------+
| Do you want to save the changes |
|
Yes
No
|
+---------------------------------+
+------------------+
Figure 86: Menu Exit from Configuration in Telnet
The NetCom terminates the Telnet interface when this operation is finished, even when the modifications are not saved to Flash Memory.
6.2.5.3 Reboot
Telnet: “Save&Exit”, option “Reboot”.
Users may restart the firmware of the NetCom. Modified configurations are activated by the restart
process. Such a restart is necessary for some changes like IP configuration, others do not require a
restart.
Save&Exit
+------------------+
| Save Parameter |
| Exit
|
| Reboot
|
+---------------------------------+
| Do you want to save the changes |
Yes
No
|
|
+---------------------------------+
+------------------+
Figure 87: Exit and Reboot in Telnet
Also here, if parameters are changed during the session, confirmation for saving them is requested.
Of course the Telnet configuration is closed, because all TCP connections are terminated by the
reboot process.
6.3 Erase Configuration of NetCom
Sometimes it is required to clear any configuration done, and go back to the Factory Settings. Users
might think this is possible with the Reset button. It is not done this way. The Reset button is
just a way to restart the NetCom without removing the power.
To make a clean configuration the DIP switches must be configured to the pattern of "Factory settings". Refer to Section 3.1 or to the table on top of the NetCom case. When this pattern
is chosen, the NetCom has to be restarted, by power off or by using the Reset button. This is
for security. When changing a DIP configuration, the ‘Factory settings’ might appear by accident.
So the NetCom requires to be restarted with this DIP pattern active to avoid accidental damage
of the configuration. While restarting, the NetCom erases the current configuration, and replaces
January 2012
NetCom Lite User Manual
88
6
Configure the Operation Modes
the parameter with the default values. When this is finished, the Power LED blinks once. Do not
power off or reset the NetCom before this blink is seen.
The Ethernet cable should not be connected, because the NetCom uses DHCP in factory configuration. Without an Ethernet cable it does not attempt to find a DHCP server, which makes a
faster reboot process.
January 2012
NetCom Lite User Manual
89
7
IP Modem Function
7 IP Modem Function
The Firmware offers the function of IP Modem. Used in this mode, the serial port of the NetCom
emulates a standard serial modem. Basically this means the NetCom will
a) answer to AT-commands on the serial port
b) establish a connection to a destination
c) inform the connected serial device of the connection
d) accept a TCP connection, and inform the serial device of that event
For connections the NetCom will use a TCP connection. This differs from a normal telephone
line, so there will be some modifications in the behavior. The target is an IP Address, not a phone
number. Also for hardware reasons the automatic baudrate detection used in today serial Modems
is not available. However this is not a problem at all, the IP Modem can be installed in Windows
as a Standard 33600bps Modem. There is an INF-file for ease of installation.
7.1 Some possible Scenarios
1. The customer has a remote management installation, operating via
telephone line. These lines may be in-house or through public phone
systems to other destinations. The customer wants to reduce costs
for these lines, management and possibly hardware, using the Intraor Internet.
2. The customer wants to contact several stations from a central server.
Because of frequent target changes he does not want to define the
target by a Virtual Com Port.
3. Remotely distributed devices contact a central system by Modem.
This is the reverse of option 1.
4. A computer without Network access shall have at least limited control on the connections established by a NetCom.
5. Old fashioned BBS installations become accessible via Internet. The
typical multi-modem box is replaced by a NetCom Server with multiple ports configured for IP Modem operation.
7.2 Serial Signals and Cables
A real modem provides the same signals as the serial port of a PC. However, where a signal is an
output on the PC, it is an input to the modem, and vice versa. So in the NetCom the emulation
of a modem must be incomplete. By exchanging RxD and TxD the data connection is fine, the
same happens for handshaking signals RTS and CTS. The DTR of the PC is connected to DSR of
NetCom, this is simple. The RI may be ignored, some connectors for serial ports also do that.
However a real modem provides DSR and DCD to the PC. There is only the DTR left on NetCom to
serve these signals. In most configurations the NetCom-DTR serves as the DCD to the computer.
January 2012
NetCom Lite User Manual
90
7
IP Modem Function
The cable must provide a DSR to the PC then, e.g. by shortcut to the PC-DTR. In some configurations the NetCom-DTR must serve as the DSR. This is configurable by a command.
The recommended cable connects as shown in this table. Please note, this installation does not
use the simply crossed signals. Especially the DSR of the PC is internally connected to the DTR
of the PC.
DB9m
3
2
7
8
6
4
1
5
PC
TxD
RxD
RTS
CTS
DSR
DTR
DCD
GND
IP-Modem DB9m DB9f
——
RxD
2
3
——
TxD
3
2
——
CTS
8
7
——
RTS
7
8
PC-DTR (internal loop-back)
——
DSR
6
4
——
DTR
4
6
——
GND
5
5
Table 15: IP Modem cable
The limitation of signals is a restriction in function, compared to real world serial modems. Since
most installations do not require the full availability of all signals, the required subset can be
selected.
7.3 Operation Modes by IP Modem
The function of IP-Modem may be configured port by port. On a NetCom with a single port
there is no much of a difference. However a NetCom with more serial ports operates each port
independently. In the following sections of this manual the phrase "serial port of a NetCom,
configured to operate as IP Modem" is replaced by "IP Modem" for brevity.
Two basic operation modes are available. The first and default mode is Modem-to-Modem. This
requires a serial port of a NetCom configured as IP Modem on both ends of the connection.
When one IP Modem dials the other, the connection is established on the TCP level. Directly
afterward both IP Modems negotiate to ensure they are a real NetCom IP Modem and are free for
connection. If successful both issue a "CONNECT . . . " response to the serial connected devices.
This is convenient for the customer to understand. The CONNECT may report some parameters,
e.g. the minimum serial speed used by both Modems. These extra parameters are not implemented
so far.
The other mode is named as Modem-to-Host. The destination is any software, which opens a TCP
port for Listen mode. It may be a second NetCom configured for TCP Raw Server Mode. It may
also be the customers application, running on a certain computer. This mode offers less features.
7.4 Hayes Commands
The IP Modem operates with a command set similar to those in real Modems. All of the commands
start with the character sequence AT.
January 2012
NetCom Lite User Manual
91
7
IP Modem Function
7.4.1 AT command set
The following table lists many standard commands (in alphabetical order). The AT is omitted for
brevity. The discussion of the functions is below the tables in section 7.5 below.
7.4.1.1 Standard AT-Commands These commands are based on the old Hayes Modem.
AT
A
Bn
Dnnn
Hayes-Standard
Answer Call
ITU-T modulation
Dial connection, basically phone
number as nnn
E
H0
I
L
M
N
O
Q
S=nn/S?
V0/1
X
Z
Echo on/off
Hang up
Device Information
Speaker Volume
Speaker On/Off
Auto serial speed
Return to data mode
Result Codes
S-Register
Responses
Busy/Dial detect
Reset to User profile
IP Modem Function
Accept a connection
Define some modem operation modes
Connect to the target system by
IP Address and TCP-Port. E.g.
ATD10,0,8,42,2023 will "dial" to port
2023 on IP Address 10.0.8.42
Enable/Disable local echo of command
Terminate the TCP connection
I0 through I9 report information
Ignored, always answered with OK
Ignored, always answered with OK
N0 no Auto, N1 reports error
Enable or disable result codes/strings
Set/request configuration registers
Numeric/text responses to commands
Ignored, always answered with OK
Standard
Table 16: IP Modem Standard AT Commands
7.4.1.2 Extended AT-Commands These commands are used in modern modems, and have
slightly different syntax depending on the model.
AT
&C
&D
&F
&K
&S
&V
&W
&Zn=dd
%C1
\Q
Standard-Extensions
DCD control
DTR meaning
Load factory Default
Flow Control
DSR control
View Profiles
Store Profile
Save for short dial
V.42bis enable
Flow control
IP Modem Function
When to turn on DCD (by IP Modems DTR)
Hang Up, Command Mode or Reset
When to turn on DSR (by IP Modems DTR)
&W0/&W1 is "Standard". ATZ1 loads profile 1
Define possible targets by DNS name or IP Address
Ignored
See &K
Table 17: IP Modem Extended AT-Commands
January 2012
NetCom Lite User Manual
92
7
IP Modem Function
7.4.1.3 Non-AT commands All these commands apply in Command Mode. If a Dial command
or an ATA succeeds with a CONNECT, the IP Modem is in data mode. Every data received on
the serial port is sent to the other station/IP Modem. And there is a special character sequence
in Data Mode, which changes back to Command Mode. This sequence is ‘+++’ by default, with
an interval of 1 second before and after this command; the three characters must appear in one
second.
7.4.2 S-Registers for Configuration
Traditional there is a set of registers to control certain operations. These registers are controlled
via the AT S-command mentioned above. This is a list of those supported by IP Modem.
Reg.
S0
S1
S2
S3
S4
S5
S8
S9
S12
S25
S26
S30
Function
Auto-Answer Ring
Ring Counter
Escape Code
Carriage Return
Line feed
Backspace
Comma pause
Carrier detect response time
Escape Guard time
DTR Ready Delay
RTS to CTS Delay
Disconnect Timer
Range/units
0-255
0-255
0-127 (ASCII)
0-127
0-127
0-32, 127
0-255 (seconds)
1-255 (0.1 sec)
20-255 (0.02 sec)
0-255 (0.01 sec)
0-255 (0.01 sec)
0-90 (seconds)
Default
0 (no Auto-Answer)
0 (read only)
43 (= "+" for "+++")
13
10
8
Accept but ignore
6
50 (= 1 second)
5 (= 50 msecs)
1 (= 10 msecs)
0 (read only, AT\Tnn)
Table 18: IP Modem S-Registers for Configuration
S0 is frequently used to configure a modem to auto answer incoming calls. S1 may be checked by
software if S0 is Zero, i.e. no Auto-Answer. S2 may be set to a different character, if the ‘+++’
may happen in typical data. Otherwise the software must insert a pause in the transmission.
7.4.3 Sample Commands used by Windows
The NetCom IP Modem is intended for manual installation as kind of a "Standard Modem" in
Windows. The reference is the MDMGEN.INF file. The commands used in that file are:
"AT&F", "ATA", "ATH", "AT &F E0 V1 &C1 &D2 S95=47 S0=0<cr>", "ATS0=0<cr>", "ATX4",
"ATS7=<#>", "AT%C", "AT\N", "AT&K", "ATS30=<#>", "ATB", "ATDP", "ATDT", "ATL", "ATM"
7.5 Description of AT–Commands
The commands are listed more or less in a functional grouping. Configuration commands are listed
also with their default settings in brackets.
January 2012
NetCom Lite User Manual
93
7
IP Modem Function
7.5.1 AT D (dial)
This is the general Dial command. The target is defined as IP Address plus TCP-port number. The
dots in the address are replaced by a comma, and the TCP port is also separated by a comma. On
normal modems a comma generates a pause in the dialing sequence. This is commonly required,
so all software will support it; even multiple comma.
The modifiers ‘T’ for Touch Tone and ‘P’ for Pulse dialing have no direct equivalent on the TCP
connection. They are used to change between Modem and Host mode, if the ATB command enables
this (ATB2 or ATB3). Otherwise the IP Modem will ignore them.
Basically dialing is done to a given IP Address plus a TCP port number. The IP Address is given in
decimal Octet format, where comma replaces the dot as the separator. This is followed by another
comma, separating the TCP Port from the IP Address. If the port is omitted, the target port is
the same as the local TCP Data Port as defined in the configuration of IP Modem (see 6.2.2.2.7
above).
There are situations where the target is known by a DNS name. This name can not be used in a
dial string, mostly because very few software will support it. So there is the option of dialing to a
pre-defined entry by shortcut. This is given by an ‘S’ followed by one or two digits. The shortcuts
S90 to S99 are reserved; so far only S1 to S4 are implemented. Shortcuts are defined and saved by
‘AT&Znn=<FDN:Port>’.
All other non-numeric characters are understood as modifiers. The IP Modem will simply ignore
them. This especially applies to space characters. Typically dial strings are:
ATDT192,168,254,254,2003<cr>
AT&Z12=demokit.vscom.com.tw:23<cr>
ATDPS12<cr>
Dial another IP Modem as a Modem-to-Modem
Define a shortcut for configuration port
Dial the other IP Modem as Modem-to-Host
Table 19: IP Modem Sample Dials
7.5.2 AT O (online / data mode)
If a connection is established, the IP Modem can still be in command mode. The ATO activates
the transparent data mode.
7.5.3 AT A (answer call)
Have the IP Modem answer an incoming call, and establish a TCP connection. This command is
required if Auto-Answer is disabled. Observe the operation mode defined by ATB.
7.5.4 AT B (modulation) [ATB1]
This command is used to define the modulation to use on the phone line. Since the only "modulation" available is IP, there is no choice. The command is used to change between Modem-to-Modem
and Modem-to-Host mode.
January 2012
NetCom Lite User Manual
94
7
IP Modem Function
ATB0
ATB1
ATB2
ATB3
Modem-to-Host mode
Modem-to-Modem mode, which is the default
Modem-to-Modem when Touch Tone dialing, Modem-to-Host when Pulse
dialing. Answer in Modem-to-Modem.
Modem-to-Modem when Touch Tone dialing, Modem-to-Host when Pulse
dialing. Answer in Modem-to-Host.
Table 20: IP Modem virtual Modulation
7.5.5 AT E (echo) [ATE1]
Disable and enable the echo of the commands received. ATE0 to disable and ATE1 to enable the
echo.
7.5.6 AT Q (quiet) [ATQ0]
Configures the IP Modem to remain quiet. The Modem will not send any response messages to
the serial port.
7.5.7 AT V (verbose) [ATV1]
Responses as numeric values (ATV0) or as text strings (ATV1).
OK
RING
ERROR
NO DIALTONE
NO ANSWER
0
2
4
6
8
CONNECT
NO CARRIER
CONNECT 1200
BUSY
1
3
5
7
Table 21: IP Modem Responses
7.5.8 AT H (hangup) [ATH0]
Command to disconnect. Also used as ATH0. The related version ATH1 to just go off-hook is not
supported, and reports an ERROR.
7.5.9 AT I(n) (information) [ATI0]
Report technical information about the IP Modem. It is frequently used to identify the device.
The answer is always sent as
<cr><lf><#response#><cr><lf><cr><lf>OK<cr><lf>
Here are the defined #response#-strings.
January 2012
NetCom Lite User Manual
95
7
IP Modem Function
ATI or
ATI0
ATI1
ATI2
ATI3
ATI4
ATI5
ATI6
ATI7
ATI8
ATI9
ATI10
ATI11
230
230.4kbps maximum
100000000
100Mbps Ethernet
Version 1.0 / <compile-date>
Current Profile
Version of Modem-Firmware
NetCom 230k IP-Modem
Device Identification
(<Name>\Serial#\IP-#:port\Com-X\NetCom)
Display serial port used
<very extended information>
Table 22: IP Modem Information Responses
7.5.10 AT S (setup)
Set and read the S-registers for configuration. ATSrr? is a request to read the current value of
S-register number rr, ATSrr=nnn stores the value nnn in the register rr. Unknown registers report
ERROR. See section 7.4.2 above for possible registers and parameters.
7.5.11 AT L (loudness)
and
7.5.12 AT M (speaker)
These commands are answered with OK, but completely ignored.
speaker.
There is no function like
7.5.13 AT N (auto baud) [ATN0]
Automatic detection of serial speed. For hardware reasons this detection is not implemented. The
command ATN0 to disable automatic detection is accepted and answered with OK. The ATN1 to
enable automatic detection is not available, and answered with the ERROR response.
7.5.14 AT Z (reset)
Reset the configuration to a stored profile. IP Modem only supports profile 0 for simplicity. Same
as ATZ0 or as AT&F or AT&F0.
January 2012
NetCom Lite User Manual
96
7
IP Modem Function
7.5.15 AT &F (factory settings) [AT&F0]
This command has historically been designed as "Reset to Factory settings", while ATZ simply
meant reset. At time of invention users could change the default behavior of their Modem, so ATZ
activated the stored profile.
Nowadays the ATZ is ignored by many software. Instead AT&F is used, followed by complex
initialization strings. User may save profiles, which are selected by AT&F0 or AT&F1. There is no
longer a documented or commonplace way to revert to Factory Defaults.
The IP Modem has such an option (clear the InitString via Telnet/web), but this is not usable
to reset the configuration when the device is used as a Modem. So IP Modem will support only
user profile 0, and it uses AT&F9 to really reset the user profile to the Factory defaults.
7.5.16 AT &C (DCD configuration) [AT&C1]
Configure the DCD signal to the PC. As IP Modem this signal may be generated by the DTR
output. A standard modem can have DCD always on, and it can have the DCD follow the external
carrier signal. When set to always on by AT&C0 the DCD may have a separate source. The DTR
is free to serve as a DSR to the PC. The operation of DSR is defined by AT&S, so these commands
are related. AT&C1 is the default, the DTR operates as DCD to the PC (this will require a cable
connecting NetCom-DTR to the DCD of the PC).
This command has priority over AT&S.
7.5.17 AT &S (DSR configuration) [AT&S0]
Configure the DSR signal to the PC. As IP Modem this signal may be generated by the DTR
output. A standard modem can have DSR always on, as long as the Modem has power. Or it
can have the DSR signaling whether the IP Modem is in command or in data mode. When set to
always on by AT&S0 (this is the default) the DSR may have a separate source. The DTR is free
to serve as a DCD to the PC. The operation of DCD is defined by AT&C, so these commands are
related. An AT&S1 has DSR follow the data mode.
The AT&C has priority over this command. AT&S1 can only be effective, if AT&C0 is set.
7.5.18 AT &D (DTR configuration) [AT&D2]
Understand the DTR signal of the PC. The input on the IP Modem is the DSR, which requires
a proper serial cable. Usually this signal is either ignored, or serves to disconnect from the phone
line. There are four options:
AT&D0
AT&D1
AT&D2
AT&D3
Ignore DTR from PC
Toggle DTR to enter command mode
Toggle DTR to disconnect and enter command mode
Toggle DTR to reset the IP Modem
default
perform ATZ
Table 23: IP Modem DTR Configuration
January 2012
NetCom Lite User Manual
97
7
IP Modem Function
7.5.19 AT &K (handshake) [AT&K3]
or as alternative command . . .
7.5.20 AT \Q [AT\Q3]
Configure serial Flow Control. AT&K0 and AT\Q0 disable all Flow Control. The default is AT&K3
and AT\Q3 to use RTS/CTS Hardware Flow Control between PC and IP Modem. AT&K4 and
AT\Q1 configure for XON/XOFF Software Flow Control between PC and IP Modem. Other
Options are not supported.
7.5.21 AT &V (view profile)
Show Profiles. This will display the current profile, the stored user profile, the short dial strings
and the factory profile. Parameters are accepted but ignored. AT&V is AT&V0 and is AT&V1.
7.5.22 AT &W (save profile)
Save the current configuration as user profile. AT&W is the same as AT&W0, all other parameters
report an ERROR.
7.5.23 AT &Z (save destination)
This command will save a destination in Internet syntax. It is given by <host>:<port>. The
<host> is either an IP Address in dotted octet notation, or an FQN in correct syntax. The <port>
is a string representing a decimal number. If :<port> is omitted, the target port is the local TCP
Data Port as defined in the configuration of IP Modem (see 6.2.2.2.7 above).
January 2012
NetCom Lite User Manual
98
8
Print Server Operation
8 Print Server Operation
Sometimes the Serial Device Servers are used together with serial printers. These printers are
available via a network to several stations for printing. So far there have been two operation modes
to achieve this. First the serial port can operate as a TCP Raw Server, and the station just sends
the data to print via a TCP connection. As second option a computer running Windows could
install the driver for virtual serial ports. The printer is then controlled via this Com port. In
both these solutions the buffering of data occurred on the client station. Beginning with Firmware
version 2.2 the NetCom Devices offer a true Print Server mode, using the Line Printer Daemon
protocol as of RFC1197. Here a print server (lpd) is a station with one IP Address and a single
defined port to accept commands and data for printing. Several printers may be attached to the
print server. Each printer has a separate data queue for management of print jobs. The data of
the jobs is saved in this queue, instead of the client as before.
8.1 Printer Queue
The basic function of an lpd is to accept the data for printing, store it in a spooler queue, and send
it to the printer when this is ready for printing. This is done for several queues in parallel. Each
printer is identified by the name of the queue, where it is attached to. The NetCom Device Servers
allow to configure a custom name for each queue, while the default name is »lpd« plus the number
of the serial port (lpd1, lpd2, . . . ). This name is set in the properties of the serial port. When the
lpd is running on a separate computer, the hard disk is used to save the data of the queues. The
NetCom Servers neither have a mass storage device, nor huge amounts of memory. Each queue
accepts at least one job with a size of up to 250 KB print data. If the job has more data, memory
is either assigned dynamically to save the job, or the data is spooled through a ring buffer. Data
is printed while the client still sends data. The amount of available dynamic memory depends on
the number of ports in a NetCom Device Server, and the operations active on these ports.
8.2 Printer Reset
Before a new job is sent to the printer, this printer should be in a well known state. On a parallel
printer port this is easy to achieve. There is a defined signal to send a »reset« command to the
printer.
Such a definition is not available for serial printers. Instead there is a reset command, which users
may send via the serial line. Typically this command is specific to the manufacturer or even to the
printer model. So the NetCom allows to specify this command by entering an ‘InitString’ for each
queue.
8.2.1 Init String Definition
The Initialization of the printer typically involves ASCII control codes, ordinary ASCII characters
and some binary data. On some models it may also be necessary to provide a certain state of the
modem control signals RTS and DTR, applied with special timing. The ‘InitString’ in the NetCom
Device Serves offer all these options.
January 2012
NetCom Lite User Manual
99
8
Print Server Operation
8.2.1.1 ASCII Text Ordinary ASCII characters are entered as they are on the keyboard. The
single exception is the ’Less Than’ character ’<’, which is used for other special functions.
8.2.1.2 ASCII Control Codes ASCII control codes are entered by their standard name, enclosed
in ’Angle Brackets’, i.e. in ’<’ and ’>’ (Greater Than). Some examples of this are <ESC>, <CR>
or <TAB>.
8.2.1.3 Numeric Codes Especially binary data must be sent by means of its numeric value. Since
the ’<’ ASCII character has a special function, the only way to use this is the numeric method.
This also applies to printable characters of some Extended ASCII character sets.
The NetCom accept the decimal value, also enclosed in angle brackets. Up to three decimal digits
define the character to send to the printer. The ’<’ is used as <60>, while the <ESC> may also
sent as <027>. The ’>’ may be used directly, however for clarity <62> should be preferred.
8.2.1.4 Modem Control Signals Via the ‘InitString’ control of RTS and DTR is available. This
manual does not make statements about voltage levels on the signals, these are just set to an active
or inactive state. <RTS+> and <RTS-> activate and deactivate the RTS signal, while <DTR+>
and <DTR-> do the same for DTR.
8.2.1.5 Timing Options Especially when using Modem Control signals it will be required to hold
them in a given state for a defined amount of time. This may be done by applying a »Pause«command in the ‘InitString’. The delay is given as numeric value in milliseconds (msec), preceded
by a ‘P’. So <P50> causes the NetCom to wait 50 msec before proceeding with the next command
or start printing. Up to three digits are possible. If more than 999 msec are required, the Pausecommand must be repeated.
Please note: The delay is not executed as an exact time. NetCom guarantees to wait at least the
required amount of time. The smallest delay possible is 10 msec, due to internal handling of date
and time.
8.2.2 Reset Example
For example here is a hypothetical serial printer. The serial port operates at 1200 bps, 7 bit and
even parity and 1 stop bit. For Reset the printer requires the command "<ESC>@0" sent with
DTR and RTS off. When the data is transmitted, DTR must be on, and 50 msec later RTS must
also be on.
Each character sent is 10 bits long, including the start bit. At 1200 bps each character needs
8.3 msec for transmission. So the transmission lasts for 25 msec. To be sure the control signals are
inactive, an extra delay is applied after change of signals. The resulting string would be <RTS><DTR-><P10><ESC>@0<P35><DTR+><P50><RTS+> The delay of 35 msec after the
command string "<ESC>@0" shall ensure, all data is completely transmitted to the printer.
January 2012
NetCom Lite User Manual
100
8
Print Server Operation
8.3 Operation in Windows®
The Printer Server mode may be used to support serial printers in Windows® Operating System.
This is a short instruction how to install and use it. Experience on installing printers in Windows
is required for this instruction. First the installation of a new printer is given, the modification of
an existing printer setup is described later.
8.3.1 Add a New Printer
From »Control Panel« open the »Printers and Faxes« windows. Select the »Add a printer« option.
The usual »Add Printer« Wizard appears. Click the "Next" button to select the port, where the
printer is attached to.
Figure 88: Add a printer
Figure 89: Select Printer Port
Select the option of »Local Printer . . . «, but de-select the automatic detection of the printer type
as shown below.
Click the "Next" button to continue.
8.3.1.1 Create new printer port You need to create a new port for the printer, the required type
is a »Standard TCP/IP Port«.
January 2012
NetCom Lite User Manual
101
8
Print Server Operation
Figure 90: Create Printer Port
In the »Add Standard TCP/IP Port« Wizard just click the "Next" button, and have the NetCom
Serial Device Server properly configured for LPD-operation.
8.3.1.2 Name the new Printer Port
tered.
Then the properties of the new printer port must be en-
Figure 91: Name-Properties of Print Server Port
You need the network address of the NetCom, this may be the IP Address or a DNS name for
the device. The port name is only for internal identification in Windows. It will be listed in the
possible ports to connect printers to. The name is similar to »LPT1:« or »Com3:«, but it does not
denote any real hardware in your computer. You are free to enter any name not used so far. The
name is not related to the LPD Queue name on the NetCom. Again click the "Next" button.
January 2012
NetCom Lite User Manual
102
8
Print Server Operation
8.3.1.3 Configure the Printer Port As the last step in creating the printer port for your printer
you need to enter some additional information. As the »Device Type« select "Custom", and open
the "Settings . . . ".
Figure 92: Mode-Properties of Print Server Port
Under »Port Settings« select the "LPR" protocol instead of the "Raw" method. The Port Number
becomes unavailable, because the standard TCP Port 515 is used in this configuration. Enter the
Queue name you configured in the NetCom. Each serial port on a NetCom has a separate Queue
name to identify it. So it may be a good idea to name the queue after the printer attached to the
serial port. Be sure to enable the "Byte Counting", because this is required by the Print Server
function in the NetCom. Close these options with the "OK" button.
8.3.1.4 Install Printer Driver Now the printer port is installed, and the Printer installation Wizard continues. Select the printer from the list, or install a new type using an installation disk the
usual way.
8.3.2 Modify an Existing Printer
In several situations it is necessary to modify the configuration of a printer, which is already
installed in Windows. For example, the mode of use shall be changed to Printer Server Mode,
the printer is moved from a local serial port to a NetCom Serial Device Server, or the installation
program of the printer only accepts local serial ports to attach the printer to. In such situations it
is required to create a new lpd port, and modify the configuration of the printer.
8.3.2.1 Open the properties Again open »Printers and Faxes« in the Control Panel.
January 2012
NetCom Lite User Manual
103
8
Print Server Operation
Figure 93: Select Port for Printer
Select the installed printer, and open the properties. In the properties select the tab for »Ports«.
8.3.2.2 Add the Print Server Port
printer port types.
The button for "Add Port. . . " opens a dialog with the possible
Figure 94: Add Printer Port
Select "Standard TCP/IP Port" and click on "New Port. . . ". This will open the Add TCP Port
wizard as of section 8.3.1.1 above. Proceed as described there.
January 2012
NetCom Lite User Manual
104
9
TCP/IP Description
9 TCP/IP Description
TCP/IP is the protocol used on the Internet. Nowadays it is also used in local networks. This opens
access to any device connected somewhere to the Internet. But a simple contact like plugging in a
cable is not enough. The network has to be configured. Your network administrator is responsible
to do that. If any question during configuration, ask him. Configuration means to set certain
parameters in any device and computer.
Since IP-configuration is a frequent source of problems, a little bit of theory is provided here.
9.1 Recommended Settings
Basically every device on the LAN has a so-called IP Address. In typical small networks the
IP Address is similar to 192.168.X.Y, and there is a corresponding netmask of 255.255.255.0. The
X ranges from 0 to 255, while Y is from 1 to 254. The combination of X.Y must be unique in your
LAN, i.e. two stations must not have the same configuration.
9.1.1 Static Configuration
All stations on the network have a fixed IP Address. In small networks this is typically of the
192.168-type. To configure NetCom for your LAN, it must have the same 192.168.X as your
computer, and the same netmask. So it needs a unique Y to establish communication.
9.1.2 DHCP Configuration
Another typical configuration is the automatic configuration. This requires a dedicated server in
the LAN, which serves as a so-called DHCP server. Every device can send a request, the reply is
a special configuration for this device on the network. The NetCom Devices support DHCP by
default, so just use or activate it.
For best operation the DHCP server itself should be configured. It may identify the NetCom Device
by its MAC- or Ethernet-Address. There should be an internal database, to always provide the
same IP Address to stations with a given MAC. There are free DHCP server programs available8
for Windows Operating Systems.
If the DHCP server can not be configured to provide a reserved IP Address to the NetCom, it
may happen the NetCom will receive a changed address after some time. This will make the
driver for this NetCom inoperative. To solve such problems, driver version 1.5.6 invents the NetCom Helper Service (section 5.8 on page 55) to assist.
8
DHCP Server for Windows, TFTPD32
January 2012
NetCom Lite User Manual
105
9
TCP/IP Description
9.1.3 Automatic Configuration (APIPA)
A different type of automatic configuration is used by Windows. If a station is prepared for
automatic settings, it will search for a DHCP server (see above). But in SOHO networks this
server might not exist.
Windows detects this failure, and the computer self-assigns an IP Address. This address is from
the reserved LINKLOCAL block for such purposes. The IP Address is like 169.254.N.N, where N.N
is from 1.0 to 254.255; the corresponding netmask 255.255.0.0 is mandatory.
The IP Address is selected by random, and checked if already used.
The NetCom Devices do not support this method. However it is possible to assign a static
IP Address to the NetCom, which matches the network configuration. Try to find an unused
address in your network, starting at 169.254.0.1. Check by PING and ARP, if the address is used.
If not, assign it to the NetCom.
This is only a workaround. The better solution is to install or configure a simple DHCP server
program. Typical SOHO Internet Routers of today already have such a server. Or you may change
your network to static configuration.
9.1.4 Other Configuration
If the configuration of your computer differs from these examples, strong reasons are likely. Ask
your network administrator for proper parameters in this situation.
January 2012
NetCom Lite User Manual
106
10
Troubleshooting Guide
10 Troubleshooting Guide
The most common problems when using NetCom are caused by a failure in the configuration of
network parameters. This is a list of some symptoms, and tests to check them.
1. First examine the network configuration of your computer. Open a
console window (MSDOS command prompt), and use the command
IPCONFIG /ALL to retrieve the information. Among other information some data is displayed as this:
Ethernet adapter Local Area Connection:
Description..................:
Dhcp Enabled.................:
Autoconfiguration Enabled....:
IP Address...................:
Subnet Mask..................:
DHCP Server..................:
<Your LAN card>
Yes
Yes
192.168.1.154
255.255.255.0
192.168.1.1
If DHCP is activated, and there is a DHCP server found, the
configuration is OK. A common problem is an IP Address like
169.254.xxx.yyy, because this is an automated address of APIPA.
If no DHCP server is present in the network, a static configuration is recommended. Here we prefer the range of 192.168.1.1 up
to 192.168.1.254 for computer and NetCom. Change the computers
configuration, and select a similar address for NetCom.
2. Start the NetCom Manager program. Search for the device, the
Manager performs a discovery of available NetCom devices. Check
the properties of each device for a matching serial number. Once the
NetCom is identified, check the IP Address and the Netmask.
If all this information is displayed as Zero, the IP settings do not
match your computers settings. To correct this, you need administrative privileges for your computer. Start the NetCom Manager
as Administrator, and configure correct parameters in the NetCom.
Close the Manager program.
3. Important: The default configuration of NetCom may result in a
fixed IP Address. It will be the same for all connected devices. As a
side effect the Manager can not send a dedicated configuration to a
certain device. Therefore it is best to connect several NetCom one
by one, configure them, connect the next and search for that device.
4. Try to PING the NetCom. Open a console window and use PING
<IP-Address of NetCom> to send some data. The replies should
reach your computer in a few milliseconds. If they time out, check
the IP parameters again.
5. Telnet to the NetCom. Open a console window, and use the Telnet
<IP-Address of NetCom> command to connect. The configuration
menu appears. If not, open NetCom Manager, and check the setting
January 2012
NetCom Lite User Manual
107
10
Troubleshooting Guide
of Telnet port in the NetCom. The default is the name "telnet",
or the number 23.
6. Telnet to the serial port of NetCom. Open a console window, and
use the Telnet <IP-Address of NetCom> <data port> command to
connect. Everything you type is sent out through the serial port.
Every data received is displayed on the screen. To check the operation, place a standard loopback plug to the serial port. Then you
see your own data as an Echo while typing.
7. Check the Device Manager for error messages.
8. Run Hyper Terminal, and open the serial port of NetCom device. Use
the loopback plug to see the Echo of your typing. Use a Null Modem
cable, and connect it from COM1 to the NetCom. Open a second
Window of Hyper Terminal for COM1. Send some data between
these two windows. Transfer a file using ZMODEM protocol.
9. Often so-called Personal Firewall programs cause unspecific errors
when other software starts communicating. Check the documentation of the program to see how to allow access.
10. If some special function is not operative, check for the proper version
of the Firmware. In case of doubt install the latest version available
(http://www.vscom.de/).
11. In rare cases or on special hardware the driver for Windows
may have a problem. Please load and install the latest version
(http://www.vscom.de/) and try again. It is necessary to uninstall
the previous version.
12. Transmissions on IP-networks impose some extra delay in transmit
and receive times. These can add to between 5 and 10 milliseconds,
depending on configurations. Such delays may cause applications
to complain about non-functional hardware, in fact it is a protocol/delay problem.
13. Wireless Connections may fail if the Access Point does not broadcast the SSID. The NetCom Servers need the broadcast to get the
parameters from the Access Point. Hiding the SSID is not a security
feature anyway.
14. Many other problems occur because of a failed serial connection,
caused by wrong cabling. Here are some frequent causes.
a) The serial cable in RS 232 mode may simply be to long. This
mostly happens with higher transmission rates.
b) In RS 422 and RS 485 it is mandatory to also connect the GND
signal of all devices. It is a very frequent error not to do this.
The information is transferred (and defined) by the positive
or negative difference of the Data+ and Data- lines. However
the specification requires a common voltage range between the
connected devices. To ensure this range the connection of GND
is required.
January 2012
NetCom Lite User Manual
108
10
Troubleshooting Guide
c) A network in RS 485 requires biasing resistors (polarization).
The Data+ line requires a pull-up resistor to +5V, and the
Data- line needs a pull-down resistor to GND. The value is
about 750Ω to 1 kΩ. When no station is transmitting, the Datalines float. This will cause noise and strange errors. The biasing resistors place a differential voltage to the lines, at least
200 mV. These resistors must not exist on the network more
than once. Therefore they are not enabled in the NetCom serial ports. To enable them it is necessary to open the case, and
set the Jumpers (see section 3.3).
January 2012
NetCom Lite User Manual
109
11
Glossary of Terms
11 Glossary of Terms
AES: Advanced Encryption Standard
The successor of the now insecure DES. AES provides strong and
modern encryption, with long keys up to 256 Bit (DES used 56 Bit).
APIPA: Automatic Private IP Addressing
A scheme to self-assign an Address to a network device. The device selects an address of the LINKLOCAL range 169.254.1.0 to
169.254.254.255 by random. If this address is unused, it assigns it to
itself. Otherwise the next address is tested. It became widespread
with Windows 98. The netmask is 255.255.0.0, these addresses are
not routed on the Internet.
ART: Automatic Receive Transmit control
Special control for RS 485 modes. In RS 485 the line driver for
transmitting must be disabled (tri-stated) when the device does not
send data. In a 2-wire configuration this is known as data direction
change, with 4-wire it is called line contention.
CSV: Comma Separated Values
A format to store tabular data in compact text form. Each line
describes a new data set. Data fields are separated by a special
character. Though the name CSV suggests a comma (’,’), in reality
the delimiting character often is a semicolon or a <TAB> control
character.
DHCP: Dynamic Host Configuration Protocol
A service used to retrieve an IP-configuration and optionally much
more information from a database server.
FTP: File Transfer Protocol
A common protocol to access a file server.
HTTP: HyperText Transfer Protocol
The protocol used by web browsers to access a web server.
Internet: The net connecting networks
A set of protocols to exchange data between different networks.
These information’s are carried via a global network of fibers and
satellite links.
IP: Internet Protocol
The basic definitions for data packages. These Internet frames are
stored and transported embedded in data frames of the local network.
IP Address: Internet Address
The Internet address is noted as a group of 4 decimal numbers (IPv4).
Each station on the Internet has a unique address. Some ranges are
reserved for private networks, not connected to the Internet.
January 2012
NetCom Lite User Manual
110
11
Glossary of Terms
LINKLOCAL: Address range for private networks
This range 169.254.0.0-169.254.255.255 (Netmask of 255.255.0.0) is
reserved for private networks, i.e. not connected to the Internet.
Designed for small number of stations, using some automatic configuration scheme. Used with APIPA.
NAT: Network Address Translation
A technique to have a private LAN share one (few) public
IP Address(es). With NAT the transport information in IP-frames
is replaced by the public data of the NAT-Router.
Netmask: Groups stations to a Net
The AND-operation between the IP Address and the Mask is an important value. When to stations have the same result and the same
mask, they are "in the same net". Which means they can communicate direct, without transmitting to a Router.
PAT: Port Address Translation
A technique to share a public IP Address by many internal servers
on private addresses. The target address and port is replaced with
values stored in an internal table. Mostly used together with NAT.
Router: Transmits data over the Internet
The backbone devices of the Internet. Routers connect two networks
together. On one side they receive data frames containing IP-data.
They extract these data, and send them on another side; there also
stored in data frames of the second network. Typically they connect
more than two networks. The basic task is to decide which route the
IP-data must take now.
RS 232/V.24: common serial transmission
Characters are sent as separate bits, timing is well defined. The
medium is copper cable, using typical +/- 12 Volt. Each signal is
defined related to a common ground; one wire per signal plus GND.
RS 232 is a point-to-point connection.
RS 422/V.11: Industrial serial transmission (multidrop)
A transmission method with balanced signals. Designed for higher
speed, longer cables and is resistive against electrical noise. RS 422
allows for up to 16 receivers. The typical transmission is via twisted
pair copper cable using balanced signals. Sender and receivers must
share a common voltage range (max. +/-7Volt difference). Two
lines per signal, plus common GND. RS 422 is a point-to-multipoint
connection.
RS 485: Industrial serial transmission (multipoint)
The signals and cables are the same as RS 422. The transmitters
can go tri-state. Several stations can send data on the same lines, at
different times. RS 485 is a multipoint-to-multipoint connection.
SNMP: Simple Network Management Protocol
A general purpose configuration system.
SNMP may be configured and monitored.
January 2012
Devices understanding
NetCom Lite User Manual
111
11
Glossary of Terms
TCP/IP: Transmission Control Program/Internet Protocol
TCP establishes connections between two partners via the Internet.
The data is sent in IP-frames, each frame is acknowledged be the
recipient. Lost packages are repeated. Software using TCP has a
secured transmission; the delivery of the data is guaranteed.
TKIP: Temporal Key Integrity Protocol
An encryption scheme for Wireless LAN. It was developed from the
WEP. The key used for encryption is changed while data is transmitted. An attacker will not get enough data with the same key to
break the code.
UDP: User datagram protocol
Similar to TCP the data is sent in IP-frames. But in opposite there
is no connection or acknowledge by the recipient. The transmission
is faster for small data, but data can get lost. Software using UDP
must handle the related problems.
UPnP: Universal Plug and Play
Devices announce their presence on the network, and return their
capabilities on the network. Depending on the type of device certain
configuration is done, specific functions become available.
Specialized software can detect those devices, and offer their services
without manual configuration.
VPN: Virtual Private Network
A public network is used to transport data for a limited set of stations. Drivers on these stations generate virtual network cables between the stations. In many installations the communication through
the public network is encrypted, to avoid tampering of the lines.
WEP: Wired Equivalent Privacy
An encryption scheme used with early implementations of WLAN.
The idea was to make it as difficult to read other persons data,
as it was with cable communications. Due to weak definitions in
WEP nowadays it may cost an attacker less than a minute to get the
current encryption key.
WLAN: short for Wireless LAN
This is a general name, however today this phrase is used for the
IEEE 802.11-protocol definitions.
WPA: Wireless Protected Access
This is the successor of WEP. WPA not only includes better strong
encryption, there is also a set of functions to restrict access by means
of user authorization, or different hardware parameters (MAC address, distance).
January 2012
NetCom Lite User Manual
112
12
History
12 History
November 2008 First release of new manual
December 2008 Firmware version 2.6.0
June 2010 Firmware version 2.6.2
November 2011 Update NetCom 111 / 113 to hardware 2.0 (DB9 male)
Added DHCP recommendations
Windows 7 Support included
Firmware 2.6.3
January 2012 Add models NetCom 111 PoE, 113 PoE and 211 PoE with
Power over Ethernet option
January 2012
NetCom Lite User Manual
113