TEE Transducer Descriptions Topic Notes Transducer parts Identify transducer flexible shaft and distal tip, control housing, cable and connector Topic Correct Cleaning Procedure & Disinfectants Cautions TEE Transducer Cleaning and Disinfecting Notes See Disinfectants and Gels in the ‘Getting Started Manual’ and the Transducer and System Care and Cleaning User Manual, ‘Important information for TEE transducer car’ & ‘TEE Cleaning Procedure’ Power Point. Information components / Read this first These instructions help avoid damage during cleaning, disinfection and sterilisation. Report any damage to your Philips Representative and discontinue use of the transducer. This information is to be used in conjunction with your institution’s infection control procedure. Always follow the recommendations of disinfectant manufacturer. Never sterilize the transducer with autoclave, gamma radiation, gas, steam, or heat sterilization techniques. Severe damage will result. Avoidable transducer damage is not covered by the warranty or service contract Do not use paper products or products that are abrasive when cleaning the transducer, they damage the soft lens of the transducer Do not bend the flexible shaft into a circle with a diameter of less than 0.3 m (1ft) Do not use bleach on the transducer or flexible shaft Do not use isopropyl alcohol-based products on any part of the transducer except the connector housing and the handle (see illustration below) Do not soak the transducer for extended periods of time. Limit the time that the transducers are soaked in disinfectant solution to the minimum time recommended by the disinfectant manufacturer Do not rinse or immerse the steering mechanism, handle, cable, connector or the portion of the cable near the connector Follow the recommendations of the disinfectant and AER manufacturer (where applicable) Ensure that the AER system isolates the transducer handle, cable and connector from contact with fluids during the disinfectant cycle. The transducer steering mechanism is unsealed. If disinfectant or other fluid enters the steering mechanism, it corrodes the gears and electrical connections. Avoidable transducer damage is not covered by the warranty or service contract Using non-recommended disinfectants, incorrect solution strength or immersing deeper or longer than recommended can damage or discolour the transducer Fewer agents are compatible with Mini and Micro TEE. See compatibility table on page 3. Please refer to User manual for Cautions and Warnings CD-Mktg- 0001zs TEE Transducer Care document Updated October 2013 Page 2 of 4