Download Control & Communication Link System Master/Local Module type
Transcript
10 COMMUNICATION BETWEEN THE MASTER STATION AND THE REMOTE DEVICE STATION MELSEC-A 10. Communication Between the Master Station and the Remote Device Station How to set, program, and confirm the operation of the module is described using a system configuration example. 10.1 System Configuration A system with two remote device stations is used as an example. Master station A62P A3NCPU AX41 AY41 AJ61 AX42 AY42 BT11 X00 to Y20 X/Y40 X60 to to to YA0 to X1F Y3F X/Y5F X9F YDF Terminal resistor Occupies 2 stations Remote device station (station No.1) AJ65BT-64AD A/D conversion module Occupies 2 stations Remote device station (station No.3) AJ65BT-64DAV D/A conversion module Terminal resistor 10 10 - 1