Download Practical Variable Speed Drives and Power Electronics Malcolm
Transcript
3-Phase AC induction motors 55 • Operation at constant mechanical load for a period of sufficient duration for thermal equilibrium to be reached. • In the absence of any indication of the rated duty type of a motor, S1 continuous running duty should be assumed. • Designation example: S1 S2: Short-time duty • Operation at constant load, for a period of time which is less than that required to reach thermal equilibrium, followed by a rest and motor deenergised period of sufficient duration for the machine to re-establish temperatures to within 2°C of the ambient or the coolant temperature. • The values 10 min, 30 min, 60 min and 90 min are recommended periods for the rated duration of the duty cycle. • Designation example: S2 – 60 min S3: Intermittent periodic duty not affected by the starting process • A sequence of identical duty cycles, each comprising a period of operation at constant load and a period of rest when the motor is de-energized.