Installation of the ADU
3.3.2
Grounding the ADU
The ADU must be grounded using the mounting bolts. If the ADU cannot or should not
be electrically connected directly to the mounting surface, you can use a separate
grounding cable to make the connection between the ADU and the common ground to
which the ACU is also connected. If grounding to the ship ground is impossible, for
example if you have a fibre glass hull, see Alternative grounding for fiberglass hulls on
page D-7.
To obtain a good ground connection, the metal underneath the head of at least one
bolt must be clean of insulating protective coating and a serrated washer should be
used. After tightening the bolts we recommend that you seal the area suitably in order
to avoid corrosion of the grounding point. Use stainless steel bolts and washers.
For further information on grounding and RF protection see Grounding and RF
protection on page D-1.
3.3.3
Alternative ADU cable
The maximum allowed RF-loss in the ADU cable must be  20 dB at 1950 MHz and
0.9 Ohm DC. This is to ensure the performance of the system. Preferably choose one of
the cable types listed in the table below.
Cable Type
Absolute maximum
length
G02232-D
6m
RG223-D
25 m
RG214/U
50 m
S 07272B-05
95 m
Table 3-7: ADU cable types and maximum lengths
Check the data sheet from the cable supplier that both the RF- attenuation and the DCresistance are kept within the maximum specified values:
• ADU cable RF-attenuation at 1950 MHz: max. 20 dB including connector.
• ADU cable modem-attenuation at 10 MHz: Max. 2 dB
ADU cable modem-attenuation at 36 and 54 MHz: Max. 4 dB
• ADU cable loop DC-resistance max: 0.9 Ohm.
Also ensure that the specified minimum bending radius is respected. If this is not the
case, the loss in the cable will increase. Check the documentation from the cable
supplier.