Capture/Compare Unit 6 (CCU6)
Field
Bits
Type Description
TRPM2
2
rw
Trap Mode Control Bit 2
This bit defines how the trap flag TRPF can be
cleared after the trap input condition (CTRAP = 0
and TRPPEN = 1) is no longer valid (either by
CTRAP = 1 or by TRPPEN = 0).
0B
Automatic Mode:
Bit TRPF is cleared by HW if the trap input
condition is no longer valid.
1B
Manual Mode:
Bit TRPF stays 0 after the trap input condition
is no longer valid. It has to be cleared by SW
by writing ISR.RTRPF = 1.
TRPEN
[13:8]
rw
Trap Enable Control
Setting a bit enables the trap functionality for the
following corresponding output signals:
TRPEN0 = TRPCTR.8 for output CC60
TRPEN1 = TRPCTR.9 for output COUT60
TRPEN2 = TRPCTR.10 for output CC61
TRPEN3 = TRPCTR.11 for output COUT61
TRPEN4 = TRPCTR.12 for output CC62
TRPEN5 = TRPCTR.13 for output COUT62
0B
The trap functionality of the corresponding
output signal is disabled. The output state is
independent from bit IS.TRPS.
1B
The trap functionality of the corresponding
output signal is enabled. The output state is
set to the passive while IS.TRPS=1.
TRPEN13
14
rw
Trap Enable Control for Timer T13
0B
The trap functionality for output COUT63 is
disabled. The output state is independent from
bit IS.TRPS.
1B
The trap functionality for output COUT63 is
enabled. The output state is set to the passive
while IS.TRPS=1.
User’s Manual
CCU6, UM_V0.5D3
18-80
V2.1, 2008-08